Loading...
HomeMy WebLinkAbout15 BRK A51.pdf 12/21/10 Issues: Sheet No.: Sheet Contents: Plotted: Checked By: Drawn By: Commission No. SLS JJI Copyright © 2010 RWA Architects, Inc. All rights reserved. RWA Architects, Inc. 2771 Observatory Avenue Cincinnati, Ohio 45208 Office: 513-321-9506 Fax: 513-321-9507 Burks Residence 2011 Burning Tree Lane Carmel, IN 46032 10-0708 J.ITECT HCRA STATE OF IDN I ANA TERED SIGER NHOJ ISCH No. 9400134 Details A5.1 T/First Floor Plate Elev. 109'-1 1/8" T/First Floor Plate Elev. 109'-1 1/8" T/Masonry Chimney Elev. 127'-6" T/First Floor Plate Elev. 109'-1 1/8" Eave Detail • Front PorchScale: 1 1/2"=1'-0" 2A5.1 Eave Detail • Living RoomScale: 1 1/2"=1'-0" 1A5.1 Eave Detail • Kitchen /Breakfast BayScale: 1 1/2"=1'-0" 3A5.1 Plan Detail • Dining Room.Scale: 1 1/2"=1'-0" 5A5.1 Typ. Rake DetailScale: 1 1/2"=1'-0" 4A5.1 2 6 2 12 2 12 Plan Detail • Master BedroomScale: 1 1/2"=1'-0" 7A5.1 x x x x x x Fireplace SectionScale: 1/2"=1'-0" 6A5.1 T/First Floor Elev. 100'-0" T/First Floor Plate Elev. 109'-1 1/8" T/Slab Elev. 90'-0" Section Detail • Master BedroomScale: 1 1/2"=1'-0" 8A5.1 2 6 2 6 24 24 24 22 4 4 24 7 7/8" Provide 1/2" space w/compressible filler to allow for wood shrinkage. 26 26 2 6 2 6 2 6 2 6 Permit Set: 10/25/10 Pricing Set: 11/12/10 Koetter, 2244-B-Cap, ptd. Silicone rubber sealant with backer rod around flue U.L. listed spark arrestor Metal flashing thru wall 12 x 16 Modular clay tile liningsee specs. Install in accordance with ASTM C1283. Smoke shelf -parge smooth. Parge interior of smoke chamber smooth. 2'-0" 8 1/2" 2'-0" 1'-8" Stone hearth 1'-0" 1'-0" 4" min. 2" clear 2" clear 2" clear Step flashing and counter flashing 8 12 60° 2" clear 6" 1'-8" 6" 1'-0" 1'-0" 8" 1'-6 1/2" 4" min conc slab w/#5 bar @10" o.c. each way @mid-depth 3'-4" Master Bedroom 107 Wall finish -refer to schedule A6.0. 1/2" 'Quiet Rock' gypsum board Sound batt insulation Master Bath 108 2x4s @16"o.c. both sides. Provide min. 1" air space between 2x4s. 2x6 sill and top plates Wall finish -refer to schedule A6.0. 8A5.1 Master Bedroom 107 Master Bath 108 Wall finish -refer to schedule A6.0. 1/2" 'Quiet Rock' gypsum board Sound batt insulation 2x6 sill plate Wall finish -refer to schedule A6.0. 2x6 top plate 7A5.1 Wall finish -refer to schedule Roof construction -see Building Section 2/A5.0. 2x blocking as req'd. 1'-3 1/4" 7 7/8" 1/2" 12 8 Koetter, 2244-B-Cap, ptd. 1x8 gutter board, ptd. 1x6 trim, ptd. 1/2" hardi-panel soffit, ptd. Stone veneer beyond. Refer to Exterior Elevations A3.0 and A3.1. 6" copper K-style gutter Metal drip edge Casing -refer to schedule Apply jamb extensions in field to align with door head beyond. Stone veneer. Refer to Exterior Elevations A3.0 and A3.1. 1x10 trim, ptd. Koetter 2244-B-Cap, ptd. 5/4x6 trim, ptd. 1'-4" 1/2" Roof construction -see Building Section 2/A5.0. 6" copper K-style gutter Metal drip edge 2x4 ladder blocking 1x8 gutter board, ptd. 5/4x trim, ptd. 1/2" hardi-panel soffit, ptd. 1/2" Koetter, 2244-B-Cap, ptd. 1x6 trim, ptd. 1x6 T&G plank ceiling Koetter 1644-KW-Stop 1x trim, ptd. 1/4" Koetter 1857-CR Copper standing seam roof -see specifications. 6" copper K-style ogee gutter Metal drip edge Wall finish -refer to schedules Casing -refer to schedules 2x4 framing 1x8 gutter board, ptd. 5/4x trim, ptd. 1/2" hardi-panel soffit, ptd. 11 1/4" 5 1/4" 7 7/8" Blocking as req'd Refer to S2.1 for header sizes 1/2" Refer to S2.1 for beam sizes Blocking as req'd. Metal drip edge 2x4s @16"o.c. both sides. Provide min. 1" air space between 2x4s. 12 4 Corbel chimney as req'd. Face of chimney shall align w/ridge line of roof. Copper chimney cap over slope cement wash Metal studs @16" o.c. max. (in front of chimney mass only). Steel lintel 2" clear 3" 1'-0" 1'-0" Dowel foundation to footing with 24" #5 bars @18" o.c. 1'-0" 4" min. 4" 8" 4" 8" 3/4" 3/4" Stone corbels to match veneer Grout cavity solid CMU chimney Koetter 2244-B-Cap, ptd. Ash dump door, beyond. Combustion air grille. Ash dump -see specs. CMU fireplace foundation, fully grouted. See A2.0 Concrete foundation. See A2.0 1'-4" Gas starter Re-use wood mantle /surround (by Owner) 1/2" hardi-panel soffit, ptd. Refer to S2.1 for post sizes. Wall finish -refer to schedule Wood wainscot -refer to schedule Casing -refer to schedule Line of sill below 2x6 stud wall Stone veneer w/adjustable wall ties -refer to specs. Line of brick sill below Exterior plywood sheathing 1" min. airspace Low expansion spray foam insulation Hardipanel trim -refer to Ext. Elev. Blocking as req'd. 1 Rev. 1 Set: 12/20/10 1