1. These demolition notes shall serve to aid the contractor in the evaluation of the extent of demolition; but shall not be held to be all inclusive. 2. Contractors shall be responsible
for all demolition required for the installation of new construction, whether or not it is specifically shown or noted in these documents. 3. Remove all damaged gypsum board, or concrete
from existing surfaces an repair to match adjacent construction. 4. Selective electrical, mechanical, and fireprotection demolition will result in various wall/floor/ceiling openings.
Contractor to repair these areas as necessary in accordance with specifications. 5. "Construction Limits" generally illustrate areas of demolition. Other work may be required for demolition
or replacement of the other systems including MEP above ceiling items. 6. All demolition material becomes the property of the contractor and is to be removed from hospital property,
in a legal manner. The owner reserves the right to claim items whether or not those items were specifically noted "to be relocated" or "to be returned to owner." 7. The contractor is
responsible for salvaging all items in good condition for owners re-use: lights, ceiling tiles, doors, windows, plumbing fixtures, toilet accessories, etc. 8. Refer to Clarian's "Mandatory
Contractor's Orientation Requirements" (MCOR) for additional requirements. 9. Contractor to provide ten-day notice with owner-supplied forms for all system shut-downs to facilities.
Minimal exceptions will be amde in cases of emergency or schedule conflicts on an owner determined basis. 10. All mobilization and deliveries shall use only Lower Level's Loading Dock.
All deliveries shall be before 7:00 A.M. or after 4:00 P.M. ROOM NAME 101 1 A101 SIM 1t 1 A 101A A101 1 SIM DETAIL NUMBER SHEET NUMBER DETAIL NUMBER SHEET NUMBER XX XX.X X SHEET NUMBER
DETAIL NUMBER NEW DOOR AND FRAME SPECIFIC CONSTRUCTION NOTES ROOM NAME AND NUMBER INTERIOR ELEVATION SYMBOL PLAN DETAIL NEW COLUMN LINE EXISTING COLUMN LINE SECTION EXTERIOR ELEVATION
SYMBOL PARTITION TYPE WINDOW ELEVATION SYMBOL TOILET ACCESSORY 1 SPECIFIC DEMOLITION NOTES 3.15iA XX.X X SHEET NUMBER DETAIL NUMBER 1. Portions of the building shall be occupied during
construction. Contractors shall comply with the following life safety issues. Failure to list all life safety issues does not relieve the contractors from complying with federal, state
and local codes, the contractural agreement between the contractor and the owner,and the other governing bodies which have jursidiction on this project. The following are interim life
safety code issues which are specific to this project and must be addressed. A. Insure all exits provide free and unobstructed egress. B. Smoking shall be prohibited in all areas of
the building. Campus is smoke free environment. C. Develop and enforce storage, housekeeping and debris removal procedures that reduce the flammable and combustible fire load to the
lowest level necessary for daily operations. D. Secure all tools and construction materials during breaks and non-non-construction hours. E. IOSHA requires material safety data sheets
(MSDS) for all materials being used or stored on this project be made available to all workers on this jobsite. 2. The contractors shall be responsible for informing the owner in writing
on a bi-weekly basis, the construction schedule for the approaching two weeks construction period. Any storage materials access or egress problems, traffic flow or normal owner operations
which are to be affected must be protected and/or agreed upon by owner. All costs shall be incurred by the general contractor. 3. Any services which must be temporarily shut off must
be coordinated with the owner. 4. All construction areas, removal traffic pattern areas and associated work areas shall be kept clean of debris by the contractors daily. 5. Fire rated
wall and ceiling penetrations must comply with E-814. 6. The general contractor shall provide all necessary fire treated wood blocking for all trades. Continuous blocking required for
all wall hung shelving, casework, grab bars and handrails. Brace walls with wall hung items to deck as by printed stud mfg. recommendations. 7. Dimensions are to face of stud or masonry,
unless otherwise noted. 8. Existing surfaces shall be prepared to accept new finishes, per finish material manufacturer recommendations. This preperation of substrate shall be the responsibility
of the particular finish contractor. If no preperation work is done to surfaces, the contractor accepts the conditions as they are, and is responsible for the performance of the material.
9. "Construction Limits" generally illustrate areas of new construction. Other work may be required for demolition or replacement of the other systems including the MEP. 10. Contractor
to provide ten-day notice with owner-supplied forms for all system shut-downs to facilities. Minimal exceptions will be made in cases of emergency or schedule conflicts on an owner-determined
basis. 1. All work located outside of construction separation walls shall be coordinated with the owner/architect. 2. All deliveries shall be delivered at the Lower Level Load Dock.
All deliveres to be prior to 7:00 a.m. or after 4:00 p.m. 3. Use Elevator No. 10 ONLY. 4. General Contractor to hold Clawson Communication's contract to perform telecommunication work.
Architectural: Nick Slater, RA MSKTD & Associates 317.917.1190 Kyle Hardie MSKTD & Associates 317.917.1190 Engineering: Joyce Jones-Myers Loftus Engineering, Inc. 317.352.5822 Kristina
Ehlers, LC Loftus Engineering, Inc. 317.352.5822 1.5B EXTEND TO DECK ABOVE 5/8" GYPSUM BOARD (BOTH SIDES) 3 1/2" SOUND ATTENUATION BLANKET 3 5/8" 20 GA. METAL STUD FRAMING (@16" o.c.)
5/8" GYPSUM BOARD 3 5/8" 20 GA. METAL STUD FRAMING (@16" o.c.) 1-HR FIRE RESISTANT ASSEMBLY 1.5E EXTEND TO 8" A.F.C. EXTEND TO DECK ABOVE 1.5C 5/8" TYPE X GYPSUM BOARD (BOTH SIDES) SOUND
ATTENUATION BLANKET 3 5/8" 20 GA. METAL STUD FRAMING (@16" o.c.) 1-HR FIRE RESISTANT SHAFT WALL ASSEMBLY U415, System A 1.4B 4" USG C-H STUDS, 20GA., 24"o.c. (DESIGNATION 400CH-34) 5/8"
TYPE X GYPSUM BOARD 1" GYPSUM LINER PANEL 4". HIGHER PRIORITY PARTITION LOWER PRIORITY PARTITION GYPSUM BOARD CONTINUES THROUGH STUD CAVITY OF LOWER PRIORITY WALL. RATING 3 HOUR WALL
2 HOUR WALL 1 HOUR WALL SMOKE PARTITION NON RATED PARTITION PRIORITY 12345 (LOWER NUMBER, HIGHER PRIORI TY) NOTE: CONTRACTOR IS RESPONSIBLE FOR ALL DEMOLITION AND CONSTRUCTION TO MEET
PRIORITY LEVEL AT CONTINUOUS WALL RUNS AND CORNERS. THIS RESPONSIBILITY IS FOR NEW AND EXISTING CONSTRUCTION. COMMISSION NUMBER DATE SHEET NUMBER SHEET TITLE CERTIFICATION The concepts,
ideas, designs, plans, and details as shown on this document are the sole property of MSKTD & Associates, Inc., and were created, developed and presented for use on this specific project.
None of the concepts, ideas, designs, plans, and details shall be used by any person, firm, or corporation for any purpose whatsoever, without the expressed written consent of MSKTD
& Associates, Inc. The Owner shall be permitted to retain copies for information and reference in connection with this project. 1715 MAGNAVOX WAY FORT WAYNE, IN 46804 voice 260.432.9337
fax 260.436.2402 930 NORTH MERIDIAN INDIANAPOLIS, IN 46204 voice 317.917.1190 fax 317.822.6236 http://www.msktd.com ARCHITECTURE ENGINEERING INTERIOR DESIGN LOFTUS NGINEERING, NC. 233
McCREA STREET SUITE 700 INDIANAPOLIS, IN 46225 E I TEL: (317) 352-5822 FAX: (317) 352-5821 12/15/2010 1:15:03 PM 11700 N. Meridian Street, Carmel, Indiana 46032 T0.1 5685 10-25-10Patient
Registration Renovation Title Sheet Clarian North Medical Center Consultants Partition Types General Demolition Notes Drawing Index General Construction Notes Specific Notes Graphic
Symbols Rated Wall Priority Clarian North Medical Center Patient Registration Renovation 11700 North Meridian Street, Carmel, Indiana 46032 M1.0 Mechanical Notes, Legends, Abbreviations
M2.0 First Floor Mechanical Plans, Details and Schedules E1.0 Electrical Symbols and Details E2.0 First Floor Electrical Demo and Lighting Plans E2.1 First Floor Power, Telecom and Signal
Plans T0.1 Title Sheet A2.1 Floor Plans A2.2 Schedules and Details A2.3 Casework Elevations Architectural: Revisions: Date: By: Mechanical: Electrical:
REF. TUBE 11.3 12 GFE 1 2 2 2 1 2 3 3 7 11 12 11 12 44 6 11 12 8 4 5 9 9 8 6 6 6 6 6 5 5 10 10 5 --TUBE FINANCE OFFICE OFFICE B111 OFFICE B114A OFFICE B114B STAFF WORK AREA B112 WHEEL
CHAIR ALCOVE C1C18A REGISTRATION B110A 106A 7' -7" 4' -0" 9" 9" 1.5C 1.5B 1.5E 104A 1.4B 1.5C A2.3 7 1.5B A2.3 6 5" A2.1 5 A2.1 4 EQ EQ 19' -1" 9' -9 1/2" 10 101A 101B 101C 101D ALIGN
(CG) (CG) (CG) (CG) (CG) x4 EXT. TZ EXT. CPT EXT. TZ CPT-1 11.3 12 GF 4' -4" 4" 11' -2" 6' -5 1/2" E 1.4B 1.4B 1.5C 1.5C 1 226 4 6 2 2 1 4 22 6 6 3 5' -9" BAY 5 B110G BAY 4 B110F BAY
3 B110E BAY 2 B110D BAY 1 B110C WORK B110B REF. 6 10 10 10 10 2' -0" 2' -0" 4" 1' -2" 11.3 12 GFE OFFICE B111 OFFICE B114A OFFICE B114B STAFF WORK AREA B112 WHEEL CHAIR ALCOVE C1C18A
REGISTRATION B110A FINANCE OFFICE 1 1 1 224 24 24 24 3 3 2 5 5 5 5 5 6 6 7 8 8 8 REROUTED 1-HOUR SMOKE BARRIER REROUTED 1-HOUR SMOKE BARRIER A2.2 elev 2 A2.3 2A2.3 1 6' -3" 2' -4" (CG)
(CG) (CG)12 F 7' -0" 2' -1 1/2" 1' -1" 1' -7" 5 7 7 8 9 BAY 5 B110G 2 1/2" FURRING w/WOOD VENEER FOR POWER /DATA BOXES +/-4' -0 1/2" 5 A2.3 3 A2.3 4 11 A2.3 +/-6' -3" 6' -2" 6' -2" 6'
-2" 4 7/8" +/-4' -11" 4 7/8" 4 7/8" 4 7/8" 4" 11' -2" +/-105.00° TYPICAL TYPICAL 1.5B 1.5B 1.5B 1.5B A2.2 3 TYPICAL 101A 101B 101C 101D A2.2 elev 3+/-4' -0" 29' -3" TYPICAL (CG) (CG)
(CG) (CG) (CG) (CG) (CG) (CG) 11.3 12 5 5 5 5 5 5 5 5 8 5 9 9 9 9 BAY 1 B110C BAY 2 B110D BAY 3 B110E BAY 4 B110F WORK B110B COMMISSION NUMBER DATE SHEET NUMBER SHEET TITLE CERTIFICATION
The concepts, ideas, designs, plans, and details as shown on this document are the sole property of MSKTD & Associates, Inc., and were created, developed and presented for use on this
specific project. None of the concepts, ideas, designs, plans, and details shall be used by any person, firm, or corporation for any purpose whatsoever, without the expressed written
consent of MSKTD & Associates, Inc. The Owner shall be permitted to retain copies for information and reference in connection with this project. 1715 MAGNAVOX WAY FORT WAYNE, IN 46804
voice 260.432.9337 fax 260.436.2402 930 NORTH MERIDIAN INDIANAPOLIS, IN 46204 voice 317.917.1190 fax 317.822.6236 http://www.msktd.com ARCHITECTURE ENGINEERING INTERIOR DESIGN LOFTUS
NGINEERING, NC. 233 McCREA STREET SUITE 700 INDIANAPOLIS, IN 46225 E I TEL: (317) 352-5822 FAX: (317) 352-5821 12/15/2010 1:15:00 PM 11700 N. Meridian Street, Carmel, Indiana 46032 A2.1
5685 10-25-10Patient Registration Renovation Floor Plans Clarian North Medical Center 1/8" = 1'-0" First Floor Demo Plan 1/8" = 1'-0" First Floor Plan 1/8" = 1'-0" First Floor Reflected
Ceiling Plan Specific Demolition Notes 1 (INFECTIOUS CONTROL.) CONSTRUCTION AND DUST SEPARATION WALL. 6" METAL STUD w/5/8" VINYL FACED GYPSUM BOARD AND SOUND ATTENUATION BLANKET. EXTEND
TO CEILING. TAPE SEAMS. REFER TO CLARIAN MANADATORY CONTRACTOR'S ORIENTATION REQUIREMENTS AND SPECIFICATION SECTION. MAINTAIN A MINIMUM OF 5'-0" AT EXISTING CORRIDORS AND OWNER OCCUPIED
SPACES FOR EGRESS. CONTRACTOR IS RESPONSIBLE FOR SUPPLYING AND DETERMINING WALL LOCATIONS AND NUMBER AND SIZE OF CONSTRUCTION DOORS WITHIN SEPARATION WALL. REFER FLOOR AND WALLS AS NEEDED
AFTER REMOVAL OF WALLS. 2 REMOVE EXISTING DOOR AND FRAME WITH ALL ASSOCIATED HARDWARE. RETURN TO OWNER. 3 REMOVE PORTION OF EXISTING WALL FOR NEW FINISHED OPENING OR DOOR AND FRAME ASSEMBLY.
4 REMOVE EXISTING WALL ASSEMBLY IN ITS ENTIRETY. 5 REMOVE EXISTING WALL ASSEMBLY. WALL ASSEMBLY CONSISTS OF WOOD VENEER PLYWOOD, ARCHITECTURAL GLASS AND METAL FRAMING. 6 REMOVE EXISTING
CASEWORK AND COUNTERTOP IN ITS ENTIRETY. RETURN TO OWNER. 7 REMOVE EXISTING HOLLOW METAL WINDOW SYSTEM IN ITS ENTIRETY. PREP WALL FOR INFILL. 8 EXISTING TERRAZO/CARPET LINE. TERRAZO
TO REMAIN. PROTECT. 9 REMOVE EXISTING CARPET TILE. PROTECT AND REUSE WITHIN STAFF WORK AREA #A104. 10 REMOVE PORTIONS OF EXISTING HARD AND LAY-IN CEILING. COORDINATE WITH NEW CONSTRUCTION.
AREA INDICATED IN HATCH -NOT EXCLUSIVE. 11 EXISTING CARPET TILE TO REMAIN. MODIFY AND PROTECT PER NEW WALL LOCATIONS WITHIN STAFF WORK AREA #B112. 12 REMOVE EXISTING CEILING TILE AND
GRID. Revisions: Date: By: 1 Value Engineering 12-15-10 KFH Specific Reflected Ceiling Plan Notes 1 GYPSUM BOARD BULKHEAD AT 7'-2" A.F.F. ABOVE OVERHEAD CASEWORK. REFER TO DETAIL 9/A2.3.
2 GYPSUM BOARD BULKHEAD/CEILING AT 8'-2" A.F.F. COORDINATE WITH EXISTING HARD CEILING. 3 CONTROL JOINT -CONTINUOUS ON VERTICAL FACE. 4 24" x 24" ACOUSTICAL CEILING TILE (ACT-3) AT REGISTRATION
BOOTHS ONLY. CEILING HEIGHT AT 8'-10" A.F.F. 5 NEW CEILING TILE AND GRID. REFER TO FINISH SCHEDULE. 6 EXISTING EDGE OF BULKHEAD/CEILING. REFINISH AS NEEDED. 7 GYPSUM BOARD BULKHEAD AT
8'-0" A.F.F. 8 CEILING MOUNTED SECURITY CAMERA (BY OWNER). REFER TO ELECTRICAL DWGS FOR ROUGH-INS. Specific Plan Notes 1 EXISTING TERRAZO/CARPET LINE. MAINTAIN EXISTING TERRAZO. PREP
FOR NEW CARPET TILE OVER EXISTING TERRAZO. PROVIDE A THIN COAT UP TO TERRAZO LINE FOR EVEN, SMOOTH, CONTINUOUS TRANSITION OVER EXISTING TRANSITION LINE. 2 PATCH AND INFILL WALL. INFILL
TO BE SMOOTH WITH ALIKE ADJACENT FINISHES. 3 BUMP AND GUARDRAIL WITH WALL PROTECTION (WP-1). REFER TO SECTION DETAIL 4/A2.2. 4 PROTECT EXISTING WOOD PANELING AND VENEER. 5 SOLID SURFACE
BULLNOSE. REFER TO ELEVATION 5/A2.3. 6 ENSURE 1-HOUR SMOKE BARRIER IS CONTINUOUS WITH EXISTING CONSTRUCTION. REFER TO WALL PRIORITY. 7 WALL TO RECEIVE VINYL WALLCOVERING (VWC-1) FULL
HEIGHT AND 12" TALL TERRAZZO BASE. 8 WALL TO RECEIVE 12" TALL TERRAZZO BASE. 9 INSTALL (2) WALL MOUNTED ROBE HOOKS, 'BOBRICK' B-76717 -PROVIDE CONTINUOUS BLOCKING AT 4'-0" A.F.F. 10
WALL TO RECEIVE VINYL WALLCOVERING (VWC-1) FULL HEIGHT. 1/4" = 1'-0" Enlarged Plan -Private Bay 1/4" = 1'-0" Enlarged Plan -Registration Bays NOTE: UNLESS NOTED OTHERWISE, CEILING HEIGHT
IS 8'-10" A.F.F. SIM. SIM.
REFER TO PARTITION TYPE FOR WALL CONSTRUCTION DOUBLE 3 5/8" METAL STUD FRAMING CONTINUOUS SEALANT (BOTH SIDES) HOLLOW MTL. DOOR FRAME SEE SCHEDULE 2" REFER TO PARTITION TYPE FOR WALL
CONSTRUCTION DOUBLE 3 5/8" MTL. STUD FRAMING CONTINUOUS SEALANT (BOTH SIDES) HOLLOW MTL. DOOR FRAME A BA 6" 6" 1' -0" 6" 2' -8 1/4" 1/2" 3' -4 1/2" 1/2" 1/2" FACE APPLIED MUTTIN (BOTH
SIDES) 7' -10" 1 DOOR HEIGHT 2" -INDICATES NEW BUMP AND GUARD RAIL w/WALL PROTECTION (WP-1). (REFER TO SECTION DETAIL 4/A2.2). -INDICATES NEW SOLID SURFACE BULLNOSE. (REFER TO SPECIFIC
PLAN NOTE No. 6 ON SHEET A2.1). -INDICATES NEW VINYL WALLCOVERING (VWC-1). 1. ALL BULKHEADS AND DRYWALL CEILINGS SHALL BE PAINTED (P-1) UNLESS OTHERWISE NOTED. 2. ALL METAL DOOR FRAMES
SHALL BE (P-2). 3. ALL FLOORING MATERIAL TRANSITIONS SHALL BE CENTERED UNDER THE DOOR JAMB. 4. ALL CARPET TILE TO BE INSTALLED AT 45 DEGREE ANGLE. QUARTER TURN AS RECOMMENDED MY MANFACTURER.
5. 2" w. CORNER GUARD (CG): 12 ga. STAINLESS STEEL w/RADIUSED CORNER AND EDGES. HEIGHT TO BE 6'-8". SILICONE APPLIED. FLOORS CARPET TILE CPT-1 -LEES CARPETS. DESIGN CONNECT #328 FLINT
STONE. CPT-2 -ATLAS. SWIRLS (BROODLOOM). #SW22 WHISPER VOILET. BASETERRAZZO BASE TRZ-1 -CUSTOM COLOR. PRECAST 12" HEIGHT. DARK CHARCOAL w/6% MOTHER OF PEARL. RUBBER BASE RB-1 -JOHNSONITE
-4" HIGH. COLOR: COVED #29 MOON ROCK. WALLS PAINTP-1 -SHERWIN WILLIAMS. COLOR: #6378 CRISP LINEN. P-2 -SHERWIN WILLIAMS. COLOR: #6191 CONTENTED. VINYL WALL COVERING VWC-1 -SYMPHONY.
STYLE: SONNECT #AZ504725SN. COLOR: PORT. VWC-2 -MDC WALLCOVERING -STYLE: VYCON OASIS #Y449150A. COLOR: GRASSCLOTH. WALL PROTECTION WP-1 -KOROGARD WALL PROTECTION SYSTEM. COLOR: PORCELIAN.
GLASS TILE GT-1 -THE ENSEMBLE. 1" x 1" MOSAIC. STYLE: RIALTO. COLOR: RED #A10111T. (ARCHITECTURAL BRICK AND TILE) CEILING ACOUSTICAL TILE ACT-1 -ARMSTRONG. 'DUNE FINE-TEXTURED.' 24x24.
COLOR: #1772 WHITE. ACT-2 -ARMSTRONG. 'DUNE FINE-TEXTURES.' 24x48. COLOR: #1772 WHITE. ACT-3 -ARMSTRONG. 'OPTIMA OPEN PLAN.' 24x24. COLOR: #3253 WHITE. GYPSUM BOARD GYB-1 -PAINT GYPSUM
BOARD CEILING P-1 CASEWORK SOLID SURFACE SS-1 -CORIAN -COUNTERTOPS, 3/4" THICK MATERIAL. COLOR: FOSSIL WOODWD-1 -ARCHITECTURAL GRADE CHERRY -CUT: QUARTER SLICED COLOR TO MATCH ARCHITECTURAL
GRADE CHERRY (LIGHT) PLASTIC LAMINATE PL-1 -PIONITE -SUEDE #WC431-S-MILLWORK CHERRY (VERTICAL) PL-2 -FORMICA 7698-58, ASHEN CERAMIC, MATTE FINISH (COUNTERTOPS) MISCELLANEOUS TS-1 -MAHARAM
-MEGA NANO POINT #901500, COLOR: 001 CREAM. NOT IN PROJECT 3 101D 101C 101B 101A 2' -2" 3' -6" 5' -11 1/4" 5' -10" +/-4' -8" 2' -3 1/4" 3' -6" 3' -6" +/-1' -4" 3' -0" CL CL AAB AAB AAB
AAB AAB 3/A2.2 (O.H.) JAMB 5' -10" +/-4' -1 1/2" 29' -3" 2' -2" 8 7/8" 8 7/8" 8 7/8" 8 7/8" 1' -2" 2' -8 1/2"6' -1 1/2" 8' -0" 5 A2.2 28' -9" EQ EQ 8' -0" 6' -1 1/2" 2' -8 1/2" 1' -2"
CL CL A AA AB B 5/8" GYPSUM BOARD (BOTH SIDES) 3 5/8" METAL STUD FRAMING w/SOUND ATTENUATION BLANKET (@16" o.c.) 1/2" REVEAL LINE OF TERRAZZO BASE BELOW 4 7/8" 1/2" REVEAL 1x CHERRY
HARDWOOD LINE OF WALL BEYOND CHERRY HARDWOOD BUMP RAIL w/CLEAR FINISH AND 1/4" RADIUS EDGES. ANCHOR AT 4'-0" o.c. MAX. COUNTERSINK FASTNERS w/PLASTIC PLUGS TO MATCH RAIL. RUBBER BASE
2x6 FIRE TREATED WOOD BLOCKING BETWEEN STUDS OR 16 ga. 6" WIDE ANCHOR STRIPS. 1' -0" 1' -10" 8" 2" 4" 2" 6" 2" 2" 2" CHERRY HARDWOOD BUMP RAIL w/CLEAR FINISH AND 1/4" RADIUS EDGES. ANCHOR
AT 4'-0" o.c. MAX. COUNTERSINK FASTNERS w/PLASTIC PLUGS TO MATCH RAIL. 2x6 FIRE TREATED WOOD BLOCKING BETWEEN STUDS OR 16 ga. 6" WIDE ANCHOR STRIPS. TERRAZO BASE (TZ-1) (REGISTRATION
ENTRY SIDE ONLY) WINDOW ENTRY SYSTEM (WOOD) TO MATCH EXISTING WINDOW ASSEMBLY SEE REFLECTED CEILING PLAN FOR CONSTRUCTION NOTES 2x WOOD FRAMING w/1x CHERRY WOOD (WD-1) 3 5/8" METAL STUDS
w/5/8" GYPSUM BOARD (BOOTH SIDE) AT WAITING/REGISTRATION SIDE (#B110A 8' -2" AT REGISTRATION BOOTH SIDE 8' -10" 1. REPAINT ALL WALLS TO MATCH EXISTING COLOR. 2. REUSE EXISTING CEILING
TILE AND GRID. PROTECT EXISTING. REWORK GRID LAYOUT AS INDICATED ON REFLECTED CEILING PLAN. 3. AT NEW CARPET AND TERRAZZO LINE, PROVIDE JOHNSONITE TRANSITION STRIP #CTA-XX-J. 4. PATCH
AND REPAIR VINYL WALLCOVERING. INSTALL NEW VINYL WALLCOVERING AT NEW WALL LOCATIONS. 5. REWORK AND REUSE EXISTING CARPET (BROODLOOM). PROTECT. COMMISSION NUMBER DATE SHEET NUMBER SHEET
TITLE CERTIFICATION The concepts, ideas, designs, plans, and details as shown on this document are the sole property of MSKTD & Associates, Inc., and were created, developed and presented
for use on this specific project. None of the concepts, ideas, designs, plans, and details shall be used by any person, firm, or corporation for any purpose whatsoever, without the expressed
written consent of MSKTD & Associates, Inc. The Owner shall be permitted to retain copies for information and reference in connection with this project. 1715 MAGNAVOX WAY FORT WAYNE,
IN 46804 voice 260.432.9337 fax 260.436.2402 930 NORTH MERIDIAN INDIANAPOLIS, IN 46204 voice 317.917.1190 fax 317.822.6236 http://www.msktd.com ARCHITECTURE ENGINEERING INTERIOR DESIGN
LOFTUS NGINEERING, NC. 233 McCREA STREET SUITE 700 INDIANAPOLIS, IN 46225 E I TEL: (317) 352-5822 FAX: (317) 352-5821 12/15/2010 1:15:01 PM 11700 N. Meridian Street, Carmel, Indiana
46032 A2.2 5685 10-25-10Patient Registration Renovation Schedules and Details Clarian North Medical Center Door and Opening Schedule Opening No. Door Frame Details Label Door Glass Hdw
Size Mat. Ele. Mat. Ele. Head Jamb Sill . Set Remarks 101A 3'-6" x 8'-0" x 1 3/4" WD B WD ------3/A2.2 ------A 1 101B 3'-0" x 8'-0" x 1 3/4" WD B WD ------3/A2.2 ------A 1 101C 3'-6"
x 8'-0" x 1 3/4" WD B WD ------3/A2.2 ------A 1 101D 3'-6" x 8'-0" x 1 3/4" WD B WD ------3/A2.2 ------A 1 104A 3'-0" x 7'-0" x 1 3/4" WD A WD 1 1/A2.2 2/A2.2 ---45 MIN. ---2 106A 3'-0"
x 7'-0" x 1 3/4" WD A HM 1 1/A2.2 2/A2.2 ---------2 1 1/2" = 1'-0" 1 Head Detail 1 1/2" = 1'-0" 2 Jamb Detail Room Finish Schedule Room No. Name Floor Base Walls Ceiling Type (see RCP
for N E S W heights) Remarks B110A REGISTRATION CPT-1 TRZ-1 P-1 P-1 P-1 P-1 GB-1 3 B110B WORK CPT-1 RB-1 ---VWC-1 VWC-1 VWC-1 ACT-1 B110C BAY 1 CPT-1 RB-1 P-1 ---VWC-1 ---ACT-3/GB-1
B110D BAY 2 CPT-1 RB-1 P-1 1 ---P-1 ---ACT-3/GB-1 B110E BAY 3 CPT-1 RB-1 P-1 ---P-1 ---ACT-3/GB-1 B110F BAY 4 CPT-1 RB-1 VWC-1 ---P-1 ---ACT-3/GB-1 B110G BAY 5 CPT-1 RB-1 VWC-1 ---P-1
P-1 ACT-3/GB-1 B111 OFFICE CPT-2 (EXT) RB-1 VWC-2 VWC-2 VWC-2 VWC-2 ACT-2 2,4,5 B112 STAFF WORK AREA CPT-2 (EXT) RB-1 VWC-2 VWC-2 VWC-2 VWC-2 ACT-2 2,4,5 B114A OFFICE CPT-2 (EXT) RB-1
P-2 P-2 P-2 P-2 ACT-2 1,2,5 B114B OFFICE CPT-2 (EXT) RB-1 P-2 P-2 P-2 P-2 ACT-2 1,2,5 C1C18A WHEEL CHAIR ALCOVE CPT-1 RB-1 P-1 /WP-1 P-1 /WP-1 P-1 /WP-1 P-1 /WP-1 ACT-1 1,3 GLAZING TYPE
A = 1/4" CLEAR, TEMPERED Door and Frame Elevations Color Legend General Finish Remarks Window Entry System Elevations Revisions: Date: By: 1 Value Engineering 12-15-10 KFH 1 1/2" = 1'-0"
3 Jamb Detail GLAZING TYPE B = 1/4" CLEAR, TEMPERED w/FROSTED VINYL FILM (MATCH EXISTING RECENT PATTERNS). NOTE: FROST FILM TO BE DUSTED CRYSTAL. NOTE: INSTALLER TO BE SOLAR CONCEPTS,
INC. ATTN: BILL SWHEAR. 12111 E. 79TH STREET, INDIANAPOLIS, IN 46236. (317) 335-3100 NOTE: NEW WINDOW ENTRY SYSTEM TO MATCH EXISTING WINDOW AND DOOR ASSEMBLY NOTE: NEW WINDOW ENTRY SYSTEM
TO MATCH EXISTING WINDOW AND DOOR ASSEMBLY NOTE: NEW WINDOW ENTRY SYSTEM TO MATCH EXISTING WINDOW AND DOOR ASSEMBLY. 1 1/2" = 1'-0" 4 Bump Rail Detail 3/4" = 1'-0" 5 Window System Section
Specific Finish Remarks NOTE: NEW WINDOW ENTRY SYSTEM TO MATCH EXISTING WINDOW AND DOOR ASSEMBLY.
11 A2.3 (WD-1) (SS-1) (RB-1) 2' -0" 2' -0" 1 1/2" 6' -4 1/2"1 1/2" 2' -0" 2' -6" 1' -0" EQ. 1/4" 4" EQ. FINISHED END PANEL (WD-1) (WD-1) 11 A2.3 (RB-1) (WD-1) 1x WOOD TRIM (SS-1) T G
L PRINTER SHELF w/HEAVY DUTY HAFELE GLIDES 2' -6" 1' -0" 2' -1 1/2" 4' -9 1/2" 1' -6" 2 1/2" 6' -6" FINISHED END PANEL (WD-1) 2 1/2" METAL STUD FRAMING w/WOOD VENEER PANELING FOR POWER/DATA
OUTLETS K F 11 A2.3 2' -6" 4" EQ. 1/4" EQ. 2' -0" 2' -0" STANDARD 6' -2" (WD-1) (SS-1) (RB-1) (WD-1) 2' -0" 1 1/2" 2' -9" 2' -9" 1 1/2" 5' -0" 2' -0" 2" 9 A2.3 SHREDDER (N.I.C.) PRINTER
(N.I.C.) (WD-1) 2" REVEAL (TYP.) BULKHEAD SAFE (N.I.C.) REFRIGERATOR (N.I.C.) (PL-1) (PL-2) 9 A2.3 FINISHED END PANEL (PL-1) (PL-1) 2" REVEAL (TYP.) FINISHED END PANEL (PL-1) 106A 7'
-7" 3' -0" 3' -0" 3' -0" 2' -10" 1' -8" 2' -6" 2" 7' -2" BULKHEAD (RB-1) (WD-1) 1x WOOD TRIM (SS-1) 2' -6" T 1' -6" 4' -8" STANDARD 6' -2" G 1' -4" L PRINTER SHELF w/HEAVY DUTY HAFELE
GLIDES K F 104A 2' -6" 2' -6" 1" 5' -1" 2' -10" 1' -8" 2' -6" 2" 7' -2" 9 A2.3 (PL-1) 2" REVEAL BULKHEAD (TYP.) (PL-2) FINISHED END PANEL (PL-1) FINISHED END PANEL (PL-1) A2.3 12 4 1/2"
1' -11 1/2" 1' -0" 1 1/2" EQUAL 1/4" 4" EQUAL 2' -6" 2' -4" SOLID SURFACE COUNTER (SS-1) RUBBER BASE (RB-1) CHERRY WOOD VENEER (WD-1 QUARTER SAWN) ON 3/4" PLYWOOD (DOUBLE LAYER) 9 1/2"
1 1/2" 2' -1" 1 1/2" A2.3 1 1/2" 1 1/2" 8 4 1/2" 1/2" HOMOSITE WRAPPED w/(TS-1) 9 1/2" 1 1/2" CHERRY WOOD VENEER (WD-1 QUARTER SAWN) ON 3/4" PLYWOOD (DOUBLE LAYER) 1' -0" 1 1/2" 1x CHERRY
HARDWOOD R 1/4" 1/4" 105.00° 1 1/4" 1/8" 1" 2" GYP. BD. FURRDOWN SCRIBE TO WALL CABINET DOOR 7'-2" A.F.F. 1. CONTRACTOR SHALL PROVIDE WOOD BLOCKING AS REQUIRED FOR INSTALLATION OF ALL
UPPER AND LOWER UNITS 2. EDGE OF COUNTERTOP TO BE 1 1/2" THICK UNLESS NOTED OTHERWISE. 3. CABINET MFG. SHALL COORDINATE WITH OWNER ALL LOCATIONS FOR " GROMMETS" QUANTITY WILL BE IDENTIFIED
PER ELEVATION. ALL GROMMETS TO BE 3 1/2" DIA.WITH BLACK PLASTIC TRIM RING -LOCATE AT REAR OF COUNTER. OR AS DIRECTED BY OWNER. 4. ALL EXPOSED ENDS AND BACKS OF CASEWORK TO BE FINISHED
SAME AS BALANCE OF EXPOSED SURFACE, SEE FINISH SCHEDULE. 5. APPLY 1" RAD. ON ALL OUTER CORNERS OF COUNTER TOPS, U.N.O. 6. ALL END PANEL SUPPORT SHALL BE CONSTRUCTED W/1 1/2" LAMINATED
PARTICLE BD. 7. ALL COUNTER TOPS SHALL EXTEND 1" BEYOND FRONT OF CABINET DRAWER FACE. 8. ALL DRAWERS AND DOOR HANDLES SHALL BE TYPE " STANLEY, MODEL No. 4484 -CHROME VS26D 9. ALL BASE
CABINET DEPTH SHALL BE 24" UNLESS NOTED OTHERWISE 10. ALL UPPER CABINET DEPTH SHALL BE 14" UNLESS NOTED OTHERWISE 11. APPLY A 4" BACKSPLASH AT PERIMETER OF ALL COUNTER TOPS 12. APPLY
(1) ADJUSTABLE SHELF IN ALL BASE UNITS, AND (2) ADJUSTABLE SHELVES IN ALL. UPPER UNITS W/EXCEPTION OF SINK BASE UNITS. (UNLESS NOTED OTHERWISE). ALL SHELVES IN CASEWORK TO BE ADJUSTABLE
ON 1" CENTERS VERTICALLY. 13. ALL BASE UNITS SHALL HAVE A 4" H. x 3" D. TOE SPACE WITH RUBBER BASE BY FLOORING CONTRACTOR. BASE TO EXTEND TO ALL EXPOSED SIDES OF CASEWORK. " L " = DOOR/DRAWER
TO BE LOCKED WITH KEY CYLINDER. COORDINATE WITH OWNER ON KEYING REQUIREMENTS " P " = PAPER TOWEL DISPENSER LOCATED AT EVERY SINK. SUPPLIED BY OWNER, INSTALLED BY CONTRACTOR. " UL " =
UNDER UPPER CABINET LIGHT, REFER TO ELECTRICAL DRAWINGS, APPLY 2" LAMINATED APRON. " S " = STRUCTURAL SUPPORT FOR COUNTER AND/OR RECEPTION DESK -PROVIDE SUPPORT AT MAXIMUM 40" O.C. SUPPORT
TO BE SIMILAR TO 'RAKKS' SUPPORT BRACKET. MOUNT BRACKET ON 3/4" PLAIN COVER BACKING w/IN-WALL 18 GA. METAL RUNNER. " AP " = REMOVABLE ACCESS PANEL. PROVIDE COUNTERSUNK ANCHORS. " K "
= KEYBOARD TRAYS PROVIDED BY OWNER -30" WIDE " G " = GROMMETS, VERIFY LOCATION WITH OWNER " T " = FABRIC WRAPPED TACKBOARD PANEL. EQUAL TO CONWED, "RESPOND" " F " = FILE DRAWER, INTERIOR
DIMENSIONS SHALL MEET STANDARD FILE DRAWER DIMENSIONS. INSTALL AND PROVIDE HANGING FILE HARDWARE. CABINET MFG. SHALL FIELD VERIFY ALL WALL DIMENSIONS PRIOR TO FABRICATION. ALL GENERAL
CASEWORK NOTES APPLY TO ALL CASEWORK THROUGH OUT SET 14. REFER TO FLOOR PLAN FOR WALL PARTITION TYPES. 15. PAPER TOWEL DISPENSER LOCATED AT EVERY SINK. SUPPLIED BY OWNER, INSTALLED BY
G.C. 16. INSTALL CLEAR SEALANT CONTINUOUS BETWEEN TOP OF BACKSPLASH AND WALL. 17. ALL HARDWARE FOR ANCHORING/SUPPORTING CASEWORK SHALL BE CONCEALED. 18. PROVIDE 2X2 WOOD BLOCKING CONTINUOUS
AT PERIMETER FOR COUNTERTOP/SHELF SUPPORT -PAINT TO MATCH WALL. 19. COUNTERTOPS INDICATED WITHOUT BACKSPLASH SHALL BE SCRIBED TO ADJACENT WALLS/CASEWORK. 20. FILLERS PANELS BY CABINET
MANUFACTURER TO MATCH CABINETS. PROVIDE AND INSTALL. (SS-1) BULLNOSE (RB-1) (PT-1) CORNER GUARD 4" 2' -0 1/2" 1 1/2" 2' -6" 8' -11 1/2" +/-8' -11" (PT-1) COMMISSION NUMBER DATE SHEET
NUMBER SHEET TITLE CERTIFICATION The concepts, ideas, designs, plans, and details as shown on this document are the sole property of MSKTD & Associates, Inc., and were created, developed
and presented for use on this specific project. None of the concepts, ideas, designs, plans, and details shall be used by any person, firm, or corporation for any purpose whatsoever,
without the expressed written consent of MSKTD & Associates, Inc. The Owner shall be permitted to retain copies for information and reference in connection with this project. 1715 MAGNAVOX
WAY FORT WAYNE, IN 46804 voice 260.432.9337 fax 260.436.2402 930 NORTH MERIDIAN INDIANAPOLIS, IN 46204 voice 317.917.1190 fax 317.822.6236 http://www.msktd.com ARCHITECTURE ENGINEERING
INTERIOR DESIGN LOFTUS NGINEERING, NC. 233 McCREA STREET SUITE 700 INDIANAPOLIS, IN 46225 E I TEL: (317) 352-5822 FAX: (317) 352-5821 12/15/2010 1:15:02 PM 11700 N. Meridian Street,
Carmel, Indiana 46032 A2.3 5685 10-25-10Patient Registration Renovation Casework Elevations Clarian North Medical Center Revisions: Date: By: 1 Value Engineering 12-15-10 KFH 1/2" =
1'-0" 1 Casework Elevation 1/2" = 1'-0" 2 Casework Elevation 1/2" = 1'-0" 3 Casework Elevation 1/2" = 1'-0" 6 Casework Elevation 1/2" = 1'-0" 7 Casework Elevation 1/2" = 1'-0" 4 Casework
Elevations 1/2" = 1'-0" 10 Casework Elevation 1" = 1'-0" 11 Casework Detail 3" = 1'-0" 12 Casework Detail 12" = 1'-0" 8 Edge Profile 3" = 1'-0" 9 Cabinet /Soffit General Casework Notes
1/2" = 1'-0" 5 Wall Wall Elevation Elevation Typical Typical Typical
GENERAL MECHANICAL NOTES: NOTE: ALL SYMBOL DESCRIPTIONS ARE SUBJECT TO MODIFICATION ON THE DRAWINGS. ALL SYMBOLS ARE NOT NECESSARILY USED ON THIS PROJECT DUCTWORK: SUPPLY DIFFUSER: RETURN
/EXHAUST GRILLE: FITTINGS & MISCELLANEOUS ACCESSORIES: GENERAL SYMBOLS: MECHANICAL ABBREVIATIONS: M1.0 MECHANICAL NOTES, LEGENDS, ABBREVIATIONS COMMISSION NUMBER DATE SHEET NUMBER SHEET
TITLE CERTIFICATION The concepts, ideas, designs, plans, and details as shown on this document are the sole property of MSKTD & Associates, Inc., and were created, developed and presented
for use on this specific project. None of the concepts, ideas, designs, plans, and details shall be used by any person, firm, or corporation for any purpose whatsoever, without the expressed
written consent of MSKTD & Associates, Inc. The Owner shall be permitted to retain copies for information and reference in connection with this project. 1715 MAGNAVOX WAY FORT WAYNE,
IN 46804 voice 260.432.9337 fax 260.436.2402
930 NORTH MERIDIAN INDIANAPOLIS, IN 46204 46204 voice 317.917.1190 fax 317.822.6236 http://www.msktd.com ARCHITECTURE ENGINEERING INTERIOR DESIGN 233 McCREA STREET SUITE 700 INDIANAPOLIS,
IN 46225 TEL: (317) 352-5822 FAX: (317) 352-5821 11700 North Meridian Street, Carmel, IN 46032 5686 10-25-10 Patient Registration Renovation Clarian North Medical Center Revisions: Date:
By:
11.3 12 GFE GRILLE/REGISTER AND DIFFUSER SCHEDULE SUPPLY DIFFUSER DETAIL 2 RETURN/EXHAUST GRILLE DETAIL 4 LOW PRESSURE ROUND DUCT TAKE-OFF DETAIL 3 LOW PRESSURE BRANCH DUCT TAKE-OFF
DETAIL 1 FIRST FLOOR MECHANICAL DEMO PLAN M2.0 FIRST FLOOR MECH. PLANS, DETAILS & SCHEDULE FIRST FLOOR MECHANICAL PLAN COMMISSION NUMBER DATE SHEET NUMBER SHEET TITLE CERTIFICATION The
concepts, ideas, designs, plans, and details as shown on this document are the sole property of MSKTD & Associates, Inc., and were created, developed and presented for use on this specific
project. None of the concepts, ideas, designs, plans, and details shall be used by any person, firm, or corporation for any purpose whatsoever, without the expressed written consent
of MSKTD & Associates, Inc. The Owner shall be permitted to retain copies for information and reference in connection with this project. 1715 MAGNAVOX WAY FORT WAYNE, IN 46804 voice
260.432.9337 fax 260.436.2402 930 NORTH MERIDIAN INDIANAPOLIS, IN 46204 voice 317.917.1190 fax 317.822.6236 http://www.msktd.com ARCHITECTURE ENGINEERING INTERIOR DESIGN 233 McCREA STREET
SUITE 700 INDIANAPOLIS, IN 46225 TEL: (317) 352-5822 FAX: (317) 352-5821 11700 North Meridian Street, Carmel, IN 46032 5686 10-25-10 Patient Registration Renovation Clarian North Medical
Center Revisions: Date: By: MECHANICAL NOTES: DEMO NOTES:
LIGHTING: ELECTRICAL SYMBOLS LEGEND POWER SYMBOLS: SIGNAL/COMMUNICATIONS: GENERAL SYMBOLS: WIRING: B VOICE ROUGH-IN D DURESS ROUGH-IN TYPICAL CEILING MOUNTED OCCUPANCY SENSOR WIRING
DIAGRAM A CONTROL AND OPERATION NOTES: C VOICE ROUGH-IN E1.0 ELECTRICAL SYMBOLS AND DETAILS COMMISSION NUMBER DATE SHEET NUMBER SHEET TITLE CERTIFICATION The concepts, ideas, designs,
plans, and details as shown on this document are the sole property of MSKTD & Associates, Inc., and were created, developed and presented for use on this specific project. None of the
concepts, ideas, designs, plans, and details shall be used by any person, firm, or corporation for any purpose whatsoever, without the expressed written consent of MSKTD & Associates,
Inc. The Owner shall be permitted to retain copies for information and reference in connection with this project. 1715 MAGNAVOX WAY FORT WAYNE, IN 46804 voice 260.432.9337 fax 260.436.2402
930 NORTH MERIDIAN INDIANAPOLIS, IN 46204 voice 317.917.1190 fax 317.822.6236 http://www.msktd.com ARCHITECTURE ENGINEERING INTERIOR DESIGN 233 McCREA STREET SUITE 700 INDIANAPOLIS,
IN 46225 TEL: (317) 352-5822 FAX: (317) 352-5821 11700 North Meridian Street, Carmel, IN 46032 5686 10-25-10 Patient Registration Renovation Clarian North Medical Center Revisions: Date:
By:
11.3 12 GFE FIRST FLOOR ELECTRICAL DEMO PLAN E2.0 FIRST FLOOR ELECTRICAL DEMO AND LIGHTING PLANS FIRST FLOOR LIGHTING PLAN COMMISSION NUMBER DATE SHEET NUMBER SHEET TITLE CERTIFICATION
The concepts, ideas, designs, plans, and details as shown on this document are the sole property of MSKTD & Associates, Inc., and were created, developed and presented for use on this
specific project. None of the concepts, ideas, designs, plans, and details shall be used by any person, firm, or corporation for any purpose whatsoever, without the expressed written
consent of MSKTD & Associates, Inc. The Owner shall be permitted to retain copies for information and reference in connection with this project. 1715 MAGNAVOX WAY FORT WAYNE, IN 46804
voice 260.432.9337 fax 260.436.2402 930 NORTH MERIDIAN INDIANAPOLIS, IN 46204 voice 317.917.1190 fax 317.822.6236 http://www.msktd.com ARCHITECTURE ENGINEERING INTERIOR DESIGN 233 McCREA
STREET SUITE 700 INDIANAPOLIS, IN 46225 TEL: (317) 352-5822 FAX: (317) 352-5821 11700 North Meridian Street, Carmel, IN 46032 5686 10-25-10 Patient Registration Renovation Clarian North
Medical Center Revisions: Date: By: PLAN NOTES:
11.3 12 GFE 1 1 1 1 1 1 11.3 12 GFE FIRST FLOOR POWER PLAN E2.1 FIRST FLOOR POWER, SYSTEMS AND TELECOM PLANS FIRST FLOOR TELECOMMUNICATIONS AND SIGNAL PLAN COMMISSION NUMBER DATE SHEET
NUMBER SHEET TITLE CERTIFICATION The concepts, ideas, designs, plans, and details as shown on this document are the sole property of MSKTD & Associates, Inc., and were created, developed
and presented for use on this specific project. None of the concepts, ideas, designs, plans, and details shall be used by any person, firm, or corporation for any purpose whatsoever,
without the expressed written consent of MSKTD & Associates, Inc. The Owner shall be permitted to retain copies for information and reference in connection with this project. 1715 MAGNAVOX
WAY FORT WAYNE, IN 46804 voice 260.432.9337 fax 260.436.2402 930 NORTH MERIDIAN INDIANAPOLIS, IN 46204 voice 317.917.1190 fax 317.822.6236 http://www.msktd.com ARCHITECTURE ENGINEERING
INTERIOR DESIGN 233 McCREA STREET SUITE 700 INDIANAPOLIS, IN 46225 TEL: (317) 352-5822 FAX: (317) 352-5821 11700 North Meridian Street, Carmel, IN 46032 5686 10-25-10 Patient Registration
Renovation Clarian North Medical Center Revisions: Date: By: PLAN NOTES: 1 Value Engineering 12/15/10 KJE