Loading...
HomeMy WebLinkAbout0006.96 MiscellaneousDEC=13-1995 11:24 FROM RYLAND MIDWEST REGION TO INDIANAPOLIS P.004i007 'U VALUE CALCULATIONS FOR WALLS, CEILINGS & FLOORS MODEL CONCORDE A, B FILENAM& 5M302 OPTIONS 5302A2P FRAME WALL_ FOUNDATION WALL_ _Component_ _R-Value_ _Component_ R-Value_ (Frame) (Cavity) Inside Air Film .68 Inside Air Film .68 .68 Drywall or Paneling Neg. Drywall .45 .45 Insulation 11.00 Insulation 13.00 8 In. Concrete 1.10 2 x 4 Stud 4.35 Outside Air Film .17 Sheathing 3.00 3.00 Total R-Value 12.95 Siding Neg. Neg,. U-Value (1/R) .077 Outside Air Film .17 .17 Total R-Value 8.650 17.300 U-Value (1/R) 0.116 0.058 Average U-Value 80"s Cavity + 20% Frame = .069 _RING JOIST AREA_ Component _CEILING Component Inside Air Film .68 Inside Air Film .61 Insulation 13.00 Drywall .45 Ring Joist 1.89 Insulation 38.00 Siding Neg. Still Air Film .61 Outside Air Film .17 Total R=Value 39.67 Total R-Value 15.74 U-Value (1/,R) .025 U-Value (1/R) .064 _FLOORS_ GLASS --U-Value Component_ Fer Mfg Test Data-- .48 Inside Air Film .68 Plywood .62 6 In. Insulation 19.00 Still Air Film .92 _DOORS -U-Value R-13 Foam Core .19 Total R-Value 21.22 U-Value (1/R) .047 AVERAGE Uo CALCULATION- NET WALLS 117.,1 Sq.. Ft. Ring Joist @ .064= 7.44 1664.5 Sq. Ft. Frame Wall @ .069= 115.45 1781.5 =Area Total - U Total= 122.89 Ut / At=Uo or 122.89/ 1781.52 = .069 AVERAGE'Uo CALCULATION- CEILINGS 900.0 Net Ceiling, Area @ .025= 22.69 0.0 Sq. Ft. Skylite Area .480= 0.00 900.0 =Area Total - U Total= 22.69 Ut / At=Uo or 22.69/ 900.00 = .025 DEC-13-1995 11:24 FROM RYLAND MIDWEST REGION TO INDIANAPOLIS P.003i007 Uo VALUE CALCULATION FOR CODE FOR ENERGY CONSERVATION IN NEW BUILDING CONSTRUCTION & CABO MODEL ENERGY CONSERVATION CODE MODEL: CONCORDE A, B OPTIONS: 5302A2P DEGREE DAYS: 0 CLG TEMP.DIF.- 0 FILENAME 5M302 1. Ring joist area. 117.1 2. Ring joist U-Value 0.064 3. Line'l x Line 2 7.44 4. Gross frame wall area. 1906.0 5. Window area 241.6. 6. Window U-Value (See Window Data) 0.48 7. Line 5 x Line 6 115.94 8. Door panel area 0.0 9. Door U-Value 0.190 (Door glass included w/windows) 10. Line 8 x Line 9 0.00 11. Net frame wall area.(4'-(5+8)) 1664.5 12.,Frame wall U-Value 0.069 13. Line it x Line 12 115.45 (Lines) 3+7+10+13238_83 - AVERAGE WALL U=VALUE=------------ ---------------- -= .118 (Lines) 1+4 2023.07 Maximum U-Value allowed for 0 Degree Days ------------------- 0 OTVV •(COOLING) CALCULATIONS 1,. Frame Wall U-Total 115.45 2. Frame Wall TDeq 44.0 3. Doors U-Total 0.00 4. Doors TDeq 44.0 S. Windows -Total Area 241.6 6,. Window Solar Factor 126.0 7. Window Shading Coefficient 0.00 8. Window U-Total 115.94 9. Cooling Temperature Dif. 0.0 (Lines)(1*2)+(3*4)+(5*6*7)+(8*9) 31863.00 OTTV=-------------------- (Lines -From Htg)1+4 2023.07 MAXIMUM OTTV ALLOWED---------------------- 33.2 DEC-13-1995 11:24 FROM RYLRND MIDWEST REGION TO INDIANAPOLIS P.002i007 RYLAND HOMES - Wald Assembly Calculations House Model CONCORDE A, B Filename: 5M302 .Description. 5302A2P Date 12-13-1995 WALL SUMMARY ,Length Height Total First Floor Frame Walls 118 8.0 946 Second Floor Frame Walls 120 8.0 960 Ring Joists (Area) 117 Total Gross Frame Wall 2023 WINDOW SUMMARY Windows & Glass Doors ---------------------- Description Area Quantity Total ----- 20..0 --------- 1 ----- 20.0 15.8 9 142.5 9.0 1 9.0 9.5 2 19.0 11.1 1 11.1 40..0 1 40.0 Total Glass Area (Frame Walls) 241.55