VALUE
CALCULATIONS FOR
WALLS,
CEILINGS & FLOORS
MODEL CONCORDE A, B
FILENAM& 5M302
OPTIONS 5302A2P
FRAME WALL_
FOUNDATION WALL_
_Component_
_R-Value_
_Component_
R-Value_
(Frame) (Cavity)
Inside Air Film
.68
Inside Air Film
.68 .68
Drywall or Paneling
Neg.
Drywall
.45 .45
Insulation
11.00
Insulation
13.00
8 In. Concrete
1.10
2 x 4 Stud
4.35
Outside Air Film
.17
Sheathing
3.00 3.00
Total R-Value
12.95
Siding
Neg. Neg,.
U-Value (1/R)
.077
Outside Air Film
.17 .17
Total R-Value
8.650 17.300
U-Value (1/R)
0.116 0.058
Average U-Value
80"s Cavity + 20% Frame = .069
_RING JOIST AREA_
Component
_CEILING
Component
Inside Air Film
.68
Inside Air Film
.61
Insulation
13.00
Drywall
.45
Ring Joist
1.89
Insulation
38.00
Siding
Neg.
Still Air Film
.61
Outside Air Film
.17
Total R=Value
39.67
Total R-Value
15.74
U-Value (1/,R)
.025
U-Value (1/R)
.064
_FLOORS_
GLASS --U-Value
Component_
Fer Mfg Test Data--
.48
Inside Air Film
.68
Plywood
.62
6 In. Insulation
19.00
Still Air Film
.92
_DOORS -U-Value
R-13 Foam Core
.19
Total R-Value
21.22
U-Value (1/R)
.047
AVERAGE Uo CALCULATION-
NET WALLS
117.,1 Sq.. Ft. Ring Joist
@ .064= 7.44
1664.5 Sq. Ft. Frame Wall
@ .069= 115.45
1781.5 =Area Total - U Total=
122.89
Ut / At=Uo or 122.89/
1781.52 = .069
AVERAGE'Uo CALCULATION-
CEILINGS
900.0 Net Ceiling, Area @
.025= 22.69
0.0 Sq. Ft. Skylite Area
.480= 0.00
900.0 =Area Total - U Total=
22.69
Ut / At=Uo or 22.69/
900.00 = .025
DEC-13-1995 11:24 FROM RYLAND MIDWEST REGION TO INDIANAPOLIS P.003i007
Uo VALUE CALCULATION FOR CODE FOR ENERGY CONSERVATION IN
NEW BUILDING CONSTRUCTION & CABO MODEL ENERGY CONSERVATION CODE
MODEL: CONCORDE A, B OPTIONS: 5302A2P
DEGREE DAYS: 0 CLG TEMP.DIF.- 0
FILENAME 5M302
1.
Ring joist area.
117.1
2.
Ring joist U-Value
0.064
3.
Line'l x Line 2
7.44
4.
Gross frame wall area.
1906.0
5.
Window area
241.6.
6.
Window U-Value (See Window Data)
0.48
7.
Line 5 x Line 6
115.94
8.
Door panel area
0.0
9.
Door U-Value
0.190
(Door glass included w/windows)
10.
Line 8 x Line 9
0.00
11.
Net frame wall area.(4'-(5+8))
1664.5
12.,Frame
wall U-Value
0.069
13.
Line it x Line 12
115.45
(Lines) 3+7+10+13238_83
-
AVERAGE WALL U=VALUE=------------
---------------- -= .118
(Lines) 1+4 2023.07
Maximum U-Value allowed for 0 Degree Days ------------------- 0
OTVV •(COOLING) CALCULATIONS
1,.
Frame Wall U-Total
115.45
2.
Frame Wall TDeq
44.0
3.
Doors U-Total
0.00
4.
Doors TDeq
44.0
S.
Windows -Total Area
241.6
6,.
Window Solar Factor
126.0
7.
Window Shading Coefficient
0.00
8.
Window U-Total
115.94
9.
Cooling Temperature Dif.
0.0
(Lines)(1*2)+(3*4)+(5*6*7)+(8*9) 31863.00
OTTV=--------------------
(Lines -From Htg)1+4 2023.07
MAXIMUM OTTV ALLOWED---------------------- 33.2
DEC-13-1995 11:24 FROM RYLRND MIDWEST REGION TO INDIANAPOLIS P.002i007
RYLAND HOMES - Wald Assembly Calculations
House Model CONCORDE A, B Filename: 5M302
.Description. 5302A2P
Date 12-13-1995
WALL SUMMARY
,Length
Height
Total
First Floor Frame Walls
118
8.0
946
Second Floor Frame Walls
120
8.0
960
Ring Joists (Area)
117
Total Gross Frame Wall
2023
WINDOW SUMMARY
Windows & Glass Doors
----------------------
Description
Area
Quantity
Total
-----
20..0
---------
1
-----
20.0
15.8
9
142.5
9.0
1
9.0
9.5
2
19.0
11.1
1
11.1
40..0
1
40.0
Total Glass Area (Frame Walls) 241.55