HomeMy WebLinkAboutTS02.91bDOOR AND HARDWARE SCHEDULE
MARK
DOOR
FRAME
ACCESSORIES
HARDWARE
REMARKS
tag
WIDTH
HEIGHT
i
YTL
TYPE
WIDTH
WTI
DUAL
CLASS
LOUVER
OTHER
L SE
T-
SE
pip_
D MZ
CLOSER
•WI ax
R
P�ULHL/
kg
OTHER
100
EKISTIN
DOO
S AND
HART
WARE
T
1 02
1
3' -O"
8' -C
3/e
SCW
A
4 3/
HM
c
2
Ell
1 03
1
3' -0'
8' -6"
1 3/4'
SCW
A
4 3/t
HM
/AR1
2
104
105a
1
1
3'
3' -0"
8'-C
8' -6"
1 3/4'
1 3/4"
SCW
SCW
A
A
4 3/4'
4 3/4"
HM
HM
HM
HM
/AR1
1
/4" TO
—lill
•J
•J
2
2
Fel
I
[i,
105b
2
S' -o"
8' -6"
13 4
HM
4 3/t
Sliding Doors vitrify w /Browning Inv.
1 06
1
3' -O"
8' -6'
1 3/4'
SCW
A
4 we
2
1
Meeting Room
102
Hang Rod
Shelf l I
4' -9 3 4'
Hall I
103
Work Room
1106
Reception
1 101
GENERAL NOTES
Manager
1 105
1 4— EXTEND PARTITION TO
UNDERSIDE OF DECk
ir)
2'-0' 8 -1 7 8'
UNWRAPPED FIBERGLASS
INSULATION 2' -0" ON
EACH SIDE OF PARTITION
PARTITION PLAN
11001
1/8" 1' -0" Partial First Floor Plan
Conferende
104
Repair wall and finishes
as required after door
is installed
:H
6. Rules and Regulations: The following codes,
regulations and standards shall govern the
character of the work, the quality, style,
type, and capacity of all materials and
equipment used, and every requirement
included in the latest revisions of these
_L
HINGE SIDE
Of DOOR
WELDED HOLLOW
METAL FRAMES
3 -0'
EXISTING CEILING
5/8" F.C. DRYWALL
2 1 2' METAL STUDS
W/ (1) LAYER 5/8'
F.C. DRYWALL EACH
SIDE
2'
JAMB DETAIL
ARC
F t I S
FC -1
FC -1
WC -1
WB -1
WELDED HOLLOW METAL
DOOR FRAME AND ANCHOR
VATERIALS LEGE \D
ALL ROOM FINISHES TO BE:
WC -1
FLOOR COVERINGS
WALLCOVERINGS
WALL BASE
WB -1
CARPET OVER PAD:
SHAW INDUSTRIES
PEBBLE BEACH II
GREY FALCON 68561
BFG KOROSEAL
MURATONE 842473
BLUE TOURMALINE
VINYL COVE BASE:
VPI SERIES 300 2 1/2"
336 SILVER SABLE
NOTES
0 PAINT ALL DOOR FRAMES
PORTER PAINT CO.
ACADEMY GRAY 17537 -1
rc*‘
L
a)
0
0
V
O rr^^
VJ
EL: —4-.
O-
1)
V
0
U
0
Z
Q
Z
0
!/1 N Z
Z
D at°
W
U C
Z
Z
f 0
n o
crm
Q
OC
0
0
J
0
W
U
Z
Z J
0
Z
Imo.
Z 0
00
1
12
0
W
J
0
W
CD
W
U
0 Q
Q o 0
Z o z
0
/I V
c
V I
(r)_
Wo
oc
w
v
Z
0
0
PROJECT: 3272
DATE 1 1 /30/90
SHEET: R 1
1. All partitions to be 2 1 /2" metal studs
with (1) layer 5/8" F.C. drywall each side.
2. New partitions are to be centered on
centerline of exterior window mullion or
align with adjacent construction unless
dimensioned otherwise.
3. All dimensions are to centerline of stud
unless noted otherwise.
4. These drawings are intended to outline the
General Scope of work. All Contractors
shall field verify all existing conditions and
dimensions.
5. The Contractor shall be responsible for taking
all steps necessary to protect the existing
property and adjacent persons and property
from injury or damage during demolition
and construction.
regulations shall be observed:
A. National Electric Code
B. Uniform Building Code
C. N.F.P.A.
D. Uniform Plumbing Code
E. Current State and Local Codes
METAL STUDS 024" C.C.
2 1/2" VINYL COVE
BASE
EXISTING CONCRETE
SLAB
TYPICAL WALL S
CTION