NEW 314' C.W.
NEW 1 /2' H.W.
NEW 6 GAL. H("
WATER HEATEP
Y
OF FICE
102
PLUMBING ISOMETRIC
N.T.S_
RECEPTION
101
JAN,
I
NEW SINK
NEW 3/4" C W
NEW 2" VENT
4, arridLl.iorl
OFFICE
103
KEY PLAN
SECOND FLOOR
NEW 112" C.W
NEW 1/2" H.W
NEW 2" WASTE
STAIRS
T
d 2 (,oCA-re.
2,901z.
TO EXIST 1 112" C.W LINE
TO EXIST 4" VENT
L
OFFICE
104
T
TO EXIST. e" WASTE
t F
I I
II OPEN AREA
107
1•
S 1
OFFICE
106
SCOPE DOCUMENTS
THE DOCUMENTS ARE INTENDED TO INDICATE THE GENERAL SCOPE OF
THE PROJECT IN TERMS OF DESIGN CONCEPT, DIMENSIONS, AND MAJOR
ARCHITECTURAL ELEMENTS. THESE DOCUMENTS DO NOT NECESSARILY
DESCRIBE OR INDICATE ALL WORK REQUIRED FOR FULL PERFORMANCE
AND COMPLETION OF THE REQUIREMENTS OF THE CONTRACT. ON THE
BASIS OF THE GENERAL SCOPE INDICATED OR DESCRIBED, EACH TRADE
CONTRACTOR SHALL FURNISH AND INSTALL ALL ITEMS REQUIRED FOR THE
PROPER EXECUTION AND COMPLETION OF THIS WORK.
1.0 THE DRAWINGS AND SPECS. ARE
AN INSTRUMENT OF SERVICE
AND ARE THE SOLE PROPERTY
OF THE ARCHITECT. ANY RE -USE
OR DUPLICATION OF THESE
DOCUMENTS IS PROHIBITED
WITHOUT THE EXPRESSED
WRITTEN CONSENT OF THE
ARCHITECT
1.1
ALL WORK SHALL BE
PERFORMED IN STRICT
COMPLIANCE WITH ALL
APPLICABLE CODES, LAWS, AND
ORDINANCES.
1.14 THE GENERAL CONTRACTOR IS
RESPONSIBLE FOR SECURING
ALL REQUIRED PERMITS AND
THE PAYING OF ALL REQUIRED
FEES.
1.16 ALL INTERIOR FINISHES SHALL
BE IN ACCORDANCE WITH
CHAPTER 42, UBC -1989
EDITION.
OFFIC
108
Ar7
ore rl CIA L4/ I t
P eLo+ GS L
Cordµ
c.,a I ri Fop. tvl I
c r G "re ib 3L ir
z
NOTE: ALL EXIST. DOORS TO REMAIN
UNLESS OTHERWISE NOTED.
EXISTING WALLS TO REMAIN.
EXISTING WALLS TO BE REMOVED.
.LLTo P)
F-t L I. ,41e -,1.
A. Pe
1.17 ALL EXIT DOOR LOCKS SHALL BE
IN ACCORDANCE WITH SECTION
3304, UBC -1989 EDITION.
1.23 ALL PLUMBING WORK SHALL BE
IN ACCORDANCE WITH THE UPC.
1.24 ELECTRICAL CONTRACTOR
SHALL CONTACT THE UTILITY
COMPANY DURING BIDDING
PROCESS. ELECTRICAL
CONTRACTOR SHALL
COORDINATE AND VERIFY
LOCATION OF ALL PAD
MOUNTED TRANSFORMERS.
ELECTRICAL CONTRACTOR
SHALL PROVIDE ALL CONDUITS
AND OTHER ITEMS AS REQUIRED
BY THE UTILITY COMPANY.
1.25 VERIFY WITH EATON LAUTH
ALL "BUILDING STANDARD"
MATERIALS AND SYSTEMS.
WALL LEGEND
NEW WALL CONSTRUCTION TENANT PARTITION: GB -350
DEMOUNTABLE SYSTEM. PREVINYLED PANEL, BOTH SIDES OR
ALTERNATE. SEE FINISH SCHEDULE.
NEW WALL CONSTRUCTION DEMISING PARTITION: STANDARD
INSULATED PARTITION WITH VINYL BOARD, FIBERGLASS BATT
INSULATION ABOVE 2' -0 "EACH DIRECTION.
ET NO
1201
FLOOR PLAN