HomeMy WebLinkAbout0935.00PROJECT TEAM:
OWNER:
PROVIDENCE HOUSING PARTNERS, L.L.C.
333 N. PENNSYLVANIA STREET 10TH FLOOR
INDIANAPOLIS, INDIANA 46204
TEL: (317) 974 -1234
FAX: (317) 974 -1238
ARCHITECT:
LOONEY RICKS KISS ARCHITECTS INC.
88 UNION AVENUE, SUITE 900
MEMPHIS, TENNESSEE 38103
TEL: (901) 521 -1440
FAX: (901) 525 -2760
CONSULTANTS DIRECT TO THE OWNER
STRUCTURAL ENGINEER:
SPENCER ENGINEERING, INC.
1652 WHITE ASH DRIVE
CARMEL, INDIANA 46033
TEL: (317) 844 -9960
FAX: (317) 844 -9960
CONTACT: BILL SPENCER
MECHANICAL ENGINEER:
R.T. MORE CO., INC.
6340 LAPAS TRAIL
INDIANAPOLIS, INDIANA 46268
TEL: (317) 291 -1052
FAX: (317) 298 -2729
CONTACT: JOHN BENNETT
ELECTRICAL ENGINEER:
JAMES FORST ASSOCIATES
1165 E. BROADWAY
LOUISVILLE, KENTUCKY 40204
TEL: (502) 584 -4033
FAX: (502) 585 -3665
CONTACT: FRANCISCO GARCIA
LANDSCAPE ARCHITECT:
MARK TIMMONS ASSOCIATES
1i614 MAIN ST.
MIDDLETOWN, KENTUCKY 40234
TEL: (502) 244 -5992
FAX: (502) 244 -5993
CONTACT: MARK TIMMONS
CIVIL ENGINEER:
MID STATES ENGINEERING CORP.
350 E. NEW YORK, SUITE 300
INDIANAPOLIS, INDIANA 46204
TEL: (317) 634 -6434
FAX: (317) 634 -3576
CONTACT: BOB TYLER
INTERIOR DESIGNER:
DESIGN ENVIRONMENTS, INC.
95 CHASTAIN RD. NW SUITE 200
KENNESAW, GA 30144
TEL: (770) 429 -3200
FAX: (770) 429 -3201
CONTACT: DONNA DELUCA
GENERAL
PROJECT TEAM:
GODES
SITE
CONTRACTOR:
METRO CONSTRUCTION CORP.
333 N. PENNSYLVANIA STREET
10TH FL.00R
INDIANAPOLIS, INDIANA 46204
TEL: >17) 974 -1234
FAX: (317) 974 -1238
GENERAL NOTES:
THIS PROJECT IS TO BE COMPLETED IN TWO PHASES.
2. ALL. MATERIAL FINISH AND COLOR SELECTIONS SHALL BE APPROVED BY THE
OWNER AND ARCHITECT PRIOR TO INSTALLATION.
3. ERRORS OR OMI 3SIONS IN ANY SCHEDULE OR DRAWINGS DO NOT RELIEVE THE
CONTRACTOR(S) FROM EXECUTING WORK INTENDED IN THE DRAWINGS OR
DESCRIBED IN THE SPECIFICATIONS.
4. THE CONTRACTOR(5) SHALL SEAR THE TOTAL. EXPENSE FOR AND SHALL
REPAIR TO EXISTING CONDITIONS, ANY DAMAGE TO EXISTING CONSTRUCTION,
EQUIPMENT OR IMPROVEMENTS NOT INDICATED IN THE DRAWINGS OR
SPECIFICATIONS TO RECEIVE ALTERATIONS, ADDITIONS OR REMOVAL.
5. THE CONTRACTOR(S) SHALL BEAR THE TOTAL. EXPENSE FOR AND SHALL
REPAIR, TO EXISTING CONDITIONS, ANY DAMAGE TO EXISTING UNDERGROUND
UTILITIES, PIPING, CONDUIT OR EQUIPMENT.
6. ALL EXTERIOR EXPOSED WORK SHALL BE INSTALLED IN SUCH MANNER AS TO
ASSURE WEATHERTIC'HT CONDITION. CONTRACTOR SHALL PROVIDE ALL CAULKING
AND WEATHER BARRIER MATERIALS REQUIRED FOR WEATHERTIGHT CONDITIONS.
ALL OCCUPIED SPACES SHALL RECEIVE AN INSULATION BARRIER THAT 15
CONTINUOUS AT ALL EXTERIOR WALL, CEILING AND FLOOR SURFACES.
7. VENEERED WALLS. SHALL PROVIDE WEATHER PROTECTION FOR THE BUILDING
AT THE WALLS.
8. FLASHING SHALL 5E PROVIDED AS NECESSARY TO PREVENT THE ENTRANCE
OF WATER AT OPENINGS IN OR PROJECTIONS THROUGH VENEERED WALLS.
Q. WEEP HOLES SHALL BE PROVIDED I N MASONRY VENEER AT A MAXIMUM
SPACING OF 24" ON BY OMITTING MORTAR IN THE HEAD JOINTS OR AS
INDICATED ON THE D;'ZAWINGS.
10. CHIMNEYS SHALL EXTEND AT LEAST SFT. ABOVE THE HIGHEST POINT WHERE
THEY PASS THROUGH THE ROOF OF THE BUILDING AND AT LEAST 2 FT. HIGHER
THAN ANY PORTION OF THE ROOF OR BUILDING LOCATED WITHIN 10 FT.
HORIZONTALLY OF SUCH CHIMNEY.
11. FACTORY BUILT CHIMNEYS SHALL BE LISTED AND SHALL BE INSTALLED IN
ACCORDANCE WITH THE CONDITIONS OF THE LISTING, AND THE MANUFACTURER'S
INSTRUCTIONS.
1. ALL WORK TO CONFORM TO GODES, ORDINANCES AND REGULATIONS OF THE
CITY OF CARMEL, INDIANA AND OTHER AGENCIES AND AUTHORITIES HAVING
JURISDICTION OVER PROJECT.
1. THE ARCHITECTURAL REFERENCE SITE PLAN GRAPHICALLY INDICATES THE
APPROXIMATE LOCATIONS OF THE IMPROVEMENTS. REFER TO CIVIL ENGINEERS
PLANS FOR ALL HORIZONTAL DIMENSIONAL CONTROL.
2. VERIFY ALL SITE DIMENSIONS ON CIVIL DRAWINGS, CONDITIONS, EXISTING
CONSTRUCTION GRACES AND UTILITIES ON PROJECT AND CONTRACT DOCUMENTS
AT PROJECT SITE PRIOR TO BEGINNING CONSTRUCTION, DISCREPANCIES TO BE
REPORTED TO OWNED; AND ARCHITECT FOR CLARIFICATION.
5. WHEN EXGAVAT! FOR BUILDINGS OR EXCAVATING ACCESSORY THERETO,
SUCH EXCAVATIONS SHALL BE MADE SAFE TO PREVENT ANY DANGER TO LIFE
AND PROPERTY.
4. EXCAVATIONS FOR ANY PURPOSE SHALL NOT EXTEND WITHIN 1 FT. OF THE
ANGLE OF REPOSE OR NATURAL SLOPE OF THE SOIL UNDER ANY FOOTING OR
FOUNDATION, UNLESS :LUCH FOOTING OR FOUNDATION 15 FIRST PROPERLY
UNDERPINNED OR PROTECTED AGAINST SETTLEMENT.
5. FOUNDATIONS SHALL BE BUILT ON UNDISTURBED SOIL OR PROPERLY
COMPACTED FILL MATERIAL.
6. THE BOTTOM OF FOUNDATIONS SHALL EXTEND BELOW THE DEPTH OF FROST
PENETRATION, BUT NO LESS THAN 12 INCHES BELOW FINISH GRADE.
7. FINISH GRADE SHALL BE SLOPED AWAY FROM THE FOUNDATION FOR
DRAINAGE.
S. FOUNDATION WALLS OR BEAMS SHALL EXTEND ABOVE THE FINISHED GRADE A
MINIMUM OF 4 INCHES WHERE MASONRY VENEER IS USED AND A MINIMUM OF 6
INCHES ELSEWHERE.
ARCHITECTURAL SYMBOLS:
DRAWING TITLES:
DRAWING NUMBER
T i �I
SECTION MARKERS:
SHEET NUMBER
DE TA IL AND FLAN MARKERS:
DETAIL NUMBER
SHEET NUMBER
ELEVATION MARKERS:
COLUMN AND C7RI D SYSTEM:
SCALE B015141
SECTION NUMBER
ELEV4sTION
NUMB R(5)
SHEET
NUMBER
AI00
FIRE RATING
1. FIRE RESISTIVE CONSTRUCTION SHALL BE MAINTAINED AT ALL PENETRATIONS
FOR MECHANICAL, ELECTRICAL AND PLUMBING SYSTEMS AS REQUIRED S r THE
JURISDICTIONAL AUTHORITIES OVER THE PROJECT.
2. ALL PARTITIONS ENCLOSING VERTICAL OPENINGS SUCH AS STAIRWAYS, UTILITY
SHAFTS AND ELEVATOR SHAFTS WHICH ARE REQUIRED TO HAVE A FIRE
RESISTANGE RATING SHALL EXTEND FROM FLOOR TO FLOOR OR FLOOR 10 ROOF.
THESE WALLS SHALL BE CONTINUOUS THROUGH ALL CONCEALED SPACES SUCH AS
THE SPACE ABOVE THE SUSPENDED CEILING. THE SUPPORTING STRUCTURE SHALL
HAVE A FIRE RESISTANCE RATING EQUAL TO OR GREATER THAT THE FIRE
RESISTANCE RATING REQUIRED FOR THE VERTICAL ENCLOSURE. WHERE T4E
OPENINGS ARE OFFSET AT INTERMEDIATE FLOORS, THE OFFSET AND FLOOR
CONSTRUCTION SHALL BE OF CONSTRUCTION HAVING A FIRE RESISTANCE 'F NOT
LESS THAN THAT REQUIRED FOR THE ENCLOSING PARTITIONS.
3. CORRIDOR PARTITIONS, SMOKESTOP PARTITIONS, HORIZONTAL EXIT
PARTITIONS, EXIT ENCLOSURES, AND FIRE RATED WALLS REQUIRED TO HAVE
PROTECTED OPENINGS SHALL BE EFFECTIVELY AND PERMANENTLY I DENTI I ED
WITH SIGNS OR STENCILING IN A MANNER ACCEPTABLE TO THE AUTHORITY HAVING
JURISDICTION. SUCH IDENTIFICATION SHALL BE ABOVE ANY DECORATIVE CEILING
AND I N CONGEALED SPACES. SUGGESTED V`iORD I NG: FIRE AND SMOKE B.'\RRI ER
PROTECT ALL OPENINGS.
FIREBLOCKING
I. WALLS AND STUD PARTITIONS SHALL BE F I REBLOCKED AT FLOORS, CEILINGS
AND ROOFS. F I REBLOCKI NG IN NONGOMSUSTI BLE PARTITIONS SHALL NOT SE
REQUIRED AT THE CEILING FOR SUSPENDED CEILING SYSTEMS. FIREBLOGKING
SHALL CONSIST OF APPROVED NONCOMBUSTIBLE MATERIALS UNLESS OTHERWISE
SPECIFIED IN THIS CODE. MATERIAL SHALL SE SECURELY FASTENED IN PLACE.
2. F I REBLOCK I NG SHALL BE PROVIDED I N ALL. WALLS AND PARTITIONS TO CUT
OFF ALL CONCEALED DRAFT OPENINGS BOTH HORIZONTAL AND VERTICAL AND
TO FORM A FIRE BARRIER BETWEEN FLOORS AND BETWEEN THE UPPER FLOOR
AND THE ROOF SPACE.
5. F I RESLOCKI NG SHALL NOT BE COVERED OR CONGEALED UNTIL INSPECTED BY
THE BUILDING OFFICIAL.
SPRINKLERS
I. APPROVED EQUIPMENT AND LAYOUT. ONLY APPROVED SPRINKLERS AND
DEVICES SHALL BE USED IN AUTOMATIC SPRINKLER SYSTEMS AND THE COMPLETE
LAYOUT OF THE SYSTEM SHALL SE SUBMITTED TO THE BUILDING OFFICIAL FOR
APPROVAL BEFORE INSTALLATION.
2. HOSE THREADS. ALL HOSE THREADS IN CONNECTIONS SHALL BE UNIFORM WITH
THAT USED BY THE FIRE DEPARTMENT OF THE APPLICABLE GOVERNING BODY.
DRAFTSTOPPI NG
I. THE INTEGRITY OF ALL DRAFTSTOPS SHALL BE MAINTAINED.
2. DRAFTSTOPPING MATERIAL SHALL BE NOT LESS THAN 1/2 INCH GYPSUM
BOARD, 15/52 INCH WOOD STRUCTURAL PANEL, 1/2 INCH PARTICLEBOARD OR
OTHER MATERIAL APPROVED BY THE BUILDING OFFICIAL OR FIRE DEPAR`MENT.
3. DRAFTSTOPPING SHALL BE PROVIDED IN FLOOR /CEILING ASSEMBLIES ABOVE
AND IN LINE WITH TENANT SEPARATION, WHEN TENANT SEPARATION WALLS DO NOT
EXTEND TO THE FLOOR SHEATHING ABOVE.
4. CONTINUOUS EXTERIOR CORNICES OF WOOD, OR OF WOOD FRAMES, SHALL BE
DRAFTSTOPPED AT INTERVALS NOT EXCEEDING 20 FT.
5. OVERHANGS TO BE DRAFTSTOPPED AT 20' -0" O.G. INTERVALS.
6. VENTILATION SHALL BE PROVIDED TO FURNISH GROSS VENTILATION OF EACH
SEPARATE ATTIC SPACE WITH WEATHER PROTECTED VENTS.
GLAZING
I. EACH UNIT OF TEMPERED GLASS SHALL SE PERMANENTLY IDENTIFIED BY THE
MANUFACTURER.
M.E.P.
1. ALL HEATING, AIR CONDITIONING, REFRIGERATION, AND VENTILATION EQUIPMENT
AND PLENUMS SHALL CONFORM TO THE REQUIREMENTS SET FORTH IN THE UNIFORM
MECHANICAL CODE.
2. ALL ELECTRICAL SYSTEMS SHALL COMPLY WITH THE PROVISIONS OF NFPA 70.
3. ALL PLUMBING FIXTURES AND PLUMBING INSTALLATIONS SHALL CONFORM TO
THE UNIFORM PLUMBING CODE.
NORTH ARROW
SYMBOLS:
DOOR MARK
WINDOW MARK
KEY NOTE
WALL TYPE MARK
F FIRE EXTINGUISHER
VERTICAL ELEVATION MARK
A REVISION MARK
251.10 EXISTING SPOT ELEVATION
251.101
NEW SPOT ELEVATION
DRAWING INDEX:
COVER SHEET
A000 GENERAL NOTES, DRAWING INDEX, ARCH. SYMBOLS
CIVIL
C101 TITLE SHEET
C102 SPEC I F I GAT I ONS
C103 SITE PLAN
C104 SITE PLAN
CI05 GRADING PLAN
C106 GRADING PLAN
G101 UTILITY FLAN
6108 UTILITY PLAN
010q EROSION CONTROL PLAN
GII0 EROSION CONTROL PLAN
G 1 1 1 SANITARY SEWER FLAN 4 PROFILE
C112 SANITARY SEWER PLAN 4 PROFILE
C113 SANITARY SEWER PLAN 4 PROFILE
G114 ENTRANCE DETAILS
C115 ENTRANCE DETAILS
GI16 CONSTRUCTION DETAILS
0111 CONSTRUCTION DETAILS
C118 CONSTRUCTION DETAILS
G I 1 CONSTRUCTION DETAILS
LI01 LANDSCAPE PLAN
L102 LANDSCAPE FLAN
L105 LANDSCAPE PLAN
L104 LANDSCAPE PLAN
LI05 LANDSCAPE FLAN
ARCHITECTURAL
03/11/00
03/11/00
03 /11 /00
03/11/00
03/11/00
03/11/00
03/11/00
03/11/00
03/11/00
03/11/00
03/17/00
03/17/00
03/11/00
03/17/00
03/11/00
03/11/00
01/05/01
03/11/00
03/11/00
03/17/00
03/11/00
03/11/00
03/11/00
03/11/00
03/11/00
01 /05/01
A001
A002
A003
A004
A101
A102
A! 03
ARCHITECTURAL SITE PLAN
PROJECT DATA AND CODE INFORMATION
UNIT TABULATION AND SPECIFICATIONS
ADDRESSING PLAN
UNIT FLOOR PLANS UNIT A2 GARAGE
UNIT FLOOR PLANS UNIT BI -1, UNIT BI -2
UNIT FLOOR PLANS UNIT B4, UNIT B4 -S
A104 UNIT FLOOR PLANS UNIT Al, UNIT 136
A105 UNIT FLOOR PLANS UNIT A5
A106 UNIT FLOOR PLANS UNIT A5 -L
A101 UNIT FLOOR PLANS UNIT ACI -I, GARAGE
A105 UNIT FLOOR PLANS UNIT GI -2, UNIT A4
A10 UNIT FLOOR PLANS UNIT B -2
A110 UNIT FLOOR PLANS UNIT A3 -2, UNIT B3
AIII UNIT FLOOR PLANS UNIT A3 -I, UNIT B3 -I
A112 UNIT FLOOR PLANS UNIT B3 -I -GAR, GARAGE
A1I3 UNIT FLOOR PLANS UNIT 5-5
A114 UNIT FLOOR PLANS UNIT G -2
A20I
A202a
A202b
A202c
A203a
A203b
A204
BUILDING TYPE 1 FLOOR PLANS, ROOF FLANS
BUILDING TYPE II FLOOR PLANS
BUILDING TYPE I I FLOOR PLANS
BUILDING TYPE II FLOOR PLANS, ROOF PLANS
BUILDING TYPE 111 FLOOR PLANS
BUILDING TYPE III FLOOR PLANS, ROOF PLANS
BUILDING TYPE IV FLOOR PLANS, ROOF PLANS
A205 BUILDING TYPE V FLOOR PLANS, ROOF PLANS
A206 BUILDING TYPE VI FLOOR PLANS, ROOF PLANS
A301 BUILDING TYPE 1 ELEVATIONS, DETAILS
A302o BUILDING TYPE IIa ELEVATIONS, DETAILS
A302b BUILDING TYPE IIb ELEVATIONS, DETAILS
A303 BUILDING TYPE III ELEVATIONS, DETAILS
A304 BUILDING TYPE IV ELEVATIONS, DETAILS
A305 BUILDING TYPE V ELEVATIONS, DETAILS, SECTIONS
A306 DETAIL ELEVATION, DETAILS
A301 BUILDING TYPE VI ELEVATIONS, DETAILS, SECTIONS
A401 SECTI DNS
A402 SECTIONS
A403 SECTIONS
A404 SECTIONS
A405 SECTIONS
A406 SECT! DNS
A501 STAIR SECTIONS BUILDING TYPE I
A502 STAIR SECTIONS BUILDING TYPE II
A503 STAIR SECTIONS BUILDING TYPE II
A504a STAIR SECTIONS BUILDING TYPE III 4 IV
A504b STAIR SECTIONS BUILDING TYPE III 4 iv
A505 STAIR SECTIONS UNIT Al/B6, UNIT A5 -L
A506 STAIR SECTIONS UNIT CI
A601 LEASING CENTER FLOOR PLANS
A602 LEASING CENTER ELEVATIONS, ROOF PLAN
A603 LEASING CENTER WALL SECTIONS
A604 LEASING CENTER WALL SECTIONS
A605 LEASING CENTER WALL SECTIONS
A606 POOL BUILDING
A6II AMENITY PACKAGE FLOOR PLANS
A612 AMENITY PACKAGE FLOOR PLANS
A64I COMPACTOR FLOOR PLAN, ELEVATIONS, DETAILS
FIRST ISSUE REVISION LAST ISSUE
DATE: NUMBER: DATE:
03/11/00
03/11/00
03/08/00
03 /08 /oo
03/08 /00
03/08/00
03/08/00
03/08/00
03/08/00
03/08/00
03/08/00
03/08/00
03/08/00
03/08/00
03/08/00
03/08/00
03 /08/00
03/08/00
03/08/00
03/08/00
03/08/00
03/08/00
03/08/00
03/08/00
03/08/00
03/08/00
03/17/00
03/11/00
03/17/00
03/11/00
03/11/00
05/17/00
03/11/00
03/11/00
01 /05/01
03/17/00
03/11/00
03/I1/00
03/17/00
03/11/00
03/17/00
03/11/00
03/17/00
03/11/00
03/17/00
03/11/00
03/11/00
03/11/00
03/17/00
03/17/00
03/11/00
03/17/00
03/11/00
03/11/00
03/11/00
03/11/00
A62I 6 GAR GARAGE FLOOR PLAN, ELEVATIONS, DETAILS 03/11/00
A622 5 GAR GARAGE FLOOR PLAN, ELEVATIONS, DETAILS 03/11/00
A63I MA I TENANCE BUILDING FLOOR PLAN, ROOF PLAN, DTLS. 03/11/00
A632 MAINTENANCE BUILDING FLOOR PLAN, ROOF PLAN, DTLS. 03/11/00
03/11/00
01/02/01
01/02/01
01/02/01
01/02/01
08/11/00
07/14/00
01/14/00
07/14/00
07/14/00
07/14/00
07/14/00
07/14/00
07/14/00
07/14/00
07/14/00
07/14/00
07/14/00
07/14/00
01/02/01
07/14/00
07/14/00
07/14/00
07/14/00
07/14/00
07 /I4 /oo
07/14/00
07/14/00
01/02/01
07/14/00
07/14/00
07/14/00
07/14/00
07/14/00
07/14/00
07/14/00
01/02/01
07/14/00
07/14/00
07/14/00
07/14/00
07/14/00
07/14/00
07/14/00
07/14/00
07/14/00
07/14/00
07/14/00
07/14/00
07/14/00
07/14/00
07/14/00
07/14/00
07/14/00
07/14/00
0
07/14/00
07/14/00
07/14/00
07/14/00
07/14/00
07/14/00
UI
U2
El
ES
E7
E8
Eq
Ell
HARDSCAPE
A101 HARDSCAPE REFERENCE SITE PLAN
A102 POOL HARDSCAPE PLAN
A103 MISC. HARDSCAPE PLANS
A104 MISC. HARDSCAPE PLANS
A105 HARDSCAPE DETAILS AND ELEVATIONS
A106 MONUMENT SIGN PLANS, ELEVATIONS, 4 DETAILS
A101 BUS KIOSK FLAN, ELEVATIONS, 4 DETAILS
A108 TRASH GOMPA::TOR AND REGYGL I NG AREA
STRUCTURAL
03/11/00
03/11/00
03/17/00
03/11/00
03/I 1/00
03/11/00
03 /I 1/00
03/11/00
03/11/00
03/11/00
03/11/00
03/I 1/00
01/02/01
5101 TITLE SHEET
5201 TYPE 1 FRAMING 4 FOUNDATION PLANS
5202o TYPE I IA 4 115 FOUNDATION FLANS
5202b TYPE I I A 4 1 I S- FRAM I NG PLANS
S202c TYPE IIA 4 115 FRAMING PLANS
5203a TYPE III FRAMING 4 FOUNDATION PLANS
S203b TYPE III FRA`4I NG PLANS
5204 TYPE IV FRAMING 4 FOUNDATION PLANS
TYPE V FRAMING FOUNDATION PLANS
5205
S206
LEASING CENTER FRAMING 4 FOUNDATION FLANS
5207 GARAGES P._ANS AND DETAILS
5208 POOL HOUSE FLANS AND DETAILS
520 TYPE VI FRA' 1 I NG 4 FOUNDATION PLANS
MECHANICAL PLUMBING
PI
P2 PLUMBING PLAN TYPE II
P3 PLUMBING PLAN TYPE I I I
P4 PLUMBING PLAN TYPE IV
P5 PLUMBING PLAN: TYPE V
P6
P1
Pq
MI
Eq
PLUMBING PLAN TYPE 1
PLUMBING PLAN LEASING CENTER
PLUMBING PLAN AMENITY PLAN
PS PLUMBING PLAN MAINTENANCE BUILDING
PLUMBING SPECIFICATIONS
HVAG PLAN UNITS
M2 HVAG PLAN UNITS
M3 HVAG PLAN LEASING CENTER
M4 HVAG PLAN MAINTENAGE BUILDING
M5 HVAG PLAN AMENTI TY BUILDING
M6 HVAG PLAN UNIT 02
LEASING CENTER LIGHTING PLAN
ELECTRICAL
UTILITY SITE PLAN
UTILITY SITE PLAN
E4 SCHEDULES 4 LEGENDS
CIRCUIT SCHEDULES
ELECTRICAL FLAN UNITS
E2 ELECTRICAL PLAN UNITS
ES ELECTRICAL FLAN UNITS
ELECTRICAL .SPECIFICATIONS 4 DETAILS
E6 ELECTRICAL PLAN BUILDING TYPE I, IV 4 V
ELECTRICAL FLANS BUILDING TYPE IIB 4 III
LEASING CENT:7 LIGHTING PLAN
E I O LEASING CENTER POWER PLAN
MAINTENANCE BUILDING 4 GARAGE PLANS
E12 AMENITY BUILDING LIGHTING 4 POWER PLAN
EIS ELECTRICAL PLAN UNIT 02
FIRST ISSUE REVISION LAST ISSUE
DATE: NUMBER: DATE:
06/01/00
06/01/00 3 0°1/11/00
06/01/00 2 08/11/00
06/01/00
06/01/00
06/01/00 2 08 /I 1/00
06/01/00 2 05/11/00
06/01/00
03/15/00
03/15/00
03/15/00
03/15/00
03/15/00
03/15/00
03/15/00
03/15/00
03/15/00
03/15/00
03/15/00
03/15/00
03/15/00
03/15/00
01/02/01
01/26/00
01/26/00
01/26/00
01/26/00
01/26/00
01/26/00
01/26/00
01/26/00
01/26/00
01/26/00
01/26/00
01/26/00
01/26/00
01/26/00
01/26/00
07/02/01
2 05/11/00
Looney Ricks Kiss
Architecture Planning Interiors Research
175 Toyota Plaza, Suite 600
Memphis, Tennessee 38103
Telephone 901 521 1440
Fax 901 525 2760
E -mail info @Irk.com
Multi Family Plan for:
Providence Housing Partners, L.L.C.
333 North Pennsylvania Street
Indianapolis, Indiana 46204
Issues and Revisions
No. Date Issues and Revisions
01 12.10.1999 Design Development Set
02 01.20.2000 Progress Set #01
03 02.24.2000 Progress Set #02
04
03.17.2000 Permit Set
Seal
Project Name:
Carmel, Indiana
Drawing Name:
Drawn By:
07.14.2000 Revision #01
08.11.00 Revision #02
09.11.00 Revision #03
07.02.2001 Revision #04
General Notes
Drawing Index
Checked By: jr
t
�,'`yo, P tntlt0 p11'4
t N4 P1940
sa,sb
41 '%RCH II"
��`��r�rtiutt�«na
Project Number: 01.98393.00
Architectural Symbols
Providence at Old Meridian
A000
2
•.•16
i
.0
2000 Looney Ricks Kiss Architects, Inc.
Drawings, written material, and design concepts shall not be used
or reproduced in whole or part in any form or format without prior
written consent of Looney Ricks Kiss Architects, Inc. Do not scale
drawings. Use given dimensions only. If not shown, verify correct
dimensions with the Architect. Contractor shall check and verify all
dimensions and conditions at job site.
INV 'wain