Loading...
HomeMy WebLinkAbout0935.00PROJECT TEAM: OWNER: PROVIDENCE HOUSING PARTNERS, L.L.C. 333 N. PENNSYLVANIA STREET 10TH FLOOR INDIANAPOLIS, INDIANA 46204 TEL: (317) 974 -1234 FAX: (317) 974 -1238 ARCHITECT: LOONEY RICKS KISS ARCHITECTS INC. 88 UNION AVENUE, SUITE 900 MEMPHIS, TENNESSEE 38103 TEL: (901) 521 -1440 FAX: (901) 525 -2760 CONSULTANTS DIRECT TO THE OWNER STRUCTURAL ENGINEER: SPENCER ENGINEERING, INC. 1652 WHITE ASH DRIVE CARMEL, INDIANA 46033 TEL: (317) 844 -9960 FAX: (317) 844 -9960 CONTACT: BILL SPENCER MECHANICAL ENGINEER: R.T. MORE CO., INC. 6340 LAPAS TRAIL INDIANAPOLIS, INDIANA 46268 TEL: (317) 291 -1052 FAX: (317) 298 -2729 CONTACT: JOHN BENNETT ELECTRICAL ENGINEER: JAMES FORST ASSOCIATES 1165 E. BROADWAY LOUISVILLE, KENTUCKY 40204 TEL: (502) 584 -4033 FAX: (502) 585 -3665 CONTACT: FRANCISCO GARCIA LANDSCAPE ARCHITECT: MARK TIMMONS ASSOCIATES 1i614 MAIN ST. MIDDLETOWN, KENTUCKY 40234 TEL: (502) 244 -5992 FAX: (502) 244 -5993 CONTACT: MARK TIMMONS CIVIL ENGINEER: MID STATES ENGINEERING CORP. 350 E. NEW YORK, SUITE 300 INDIANAPOLIS, INDIANA 46204 TEL: (317) 634 -6434 FAX: (317) 634 -3576 CONTACT: BOB TYLER INTERIOR DESIGNER: DESIGN ENVIRONMENTS, INC. 95 CHASTAIN RD. NW SUITE 200 KENNESAW, GA 30144 TEL: (770) 429 -3200 FAX: (770) 429 -3201 CONTACT: DONNA DELUCA GENERAL PROJECT TEAM: GODES SITE CONTRACTOR: METRO CONSTRUCTION CORP. 333 N. PENNSYLVANIA STREET 10TH FL.00R INDIANAPOLIS, INDIANA 46204 TEL: >17) 974 -1234 FAX: (317) 974 -1238 GENERAL NOTES: THIS PROJECT IS TO BE COMPLETED IN TWO PHASES. 2. ALL. MATERIAL FINISH AND COLOR SELECTIONS SHALL BE APPROVED BY THE OWNER AND ARCHITECT PRIOR TO INSTALLATION. 3. ERRORS OR OMI 3SIONS IN ANY SCHEDULE OR DRAWINGS DO NOT RELIEVE THE CONTRACTOR(S) FROM EXECUTING WORK INTENDED IN THE DRAWINGS OR DESCRIBED IN THE SPECIFICATIONS. 4. THE CONTRACTOR(5) SHALL SEAR THE TOTAL. EXPENSE FOR AND SHALL REPAIR TO EXISTING CONDITIONS, ANY DAMAGE TO EXISTING CONSTRUCTION, EQUIPMENT OR IMPROVEMENTS NOT INDICATED IN THE DRAWINGS OR SPECIFICATIONS TO RECEIVE ALTERATIONS, ADDITIONS OR REMOVAL. 5. THE CONTRACTOR(S) SHALL BEAR THE TOTAL. EXPENSE FOR AND SHALL REPAIR, TO EXISTING CONDITIONS, ANY DAMAGE TO EXISTING UNDERGROUND UTILITIES, PIPING, CONDUIT OR EQUIPMENT. 6. ALL EXTERIOR EXPOSED WORK SHALL BE INSTALLED IN SUCH MANNER AS TO ASSURE WEATHERTIC'HT CONDITION. CONTRACTOR SHALL PROVIDE ALL CAULKING AND WEATHER BARRIER MATERIALS REQUIRED FOR WEATHERTIGHT CONDITIONS. ALL OCCUPIED SPACES SHALL RECEIVE AN INSULATION BARRIER THAT 15 CONTINUOUS AT ALL EXTERIOR WALL, CEILING AND FLOOR SURFACES. 7. VENEERED WALLS. SHALL PROVIDE WEATHER PROTECTION FOR THE BUILDING AT THE WALLS. 8. FLASHING SHALL 5E PROVIDED AS NECESSARY TO PREVENT THE ENTRANCE OF WATER AT OPENINGS IN OR PROJECTIONS THROUGH VENEERED WALLS. Q. WEEP HOLES SHALL BE PROVIDED I N MASONRY VENEER AT A MAXIMUM SPACING OF 24" ON BY OMITTING MORTAR IN THE HEAD JOINTS OR AS INDICATED ON THE D;'ZAWINGS. 10. CHIMNEYS SHALL EXTEND AT LEAST SFT. ABOVE THE HIGHEST POINT WHERE THEY PASS THROUGH THE ROOF OF THE BUILDING AND AT LEAST 2 FT. HIGHER THAN ANY PORTION OF THE ROOF OR BUILDING LOCATED WITHIN 10 FT. HORIZONTALLY OF SUCH CHIMNEY. 11. FACTORY BUILT CHIMNEYS SHALL BE LISTED AND SHALL BE INSTALLED IN ACCORDANCE WITH THE CONDITIONS OF THE LISTING, AND THE MANUFACTURER'S INSTRUCTIONS. 1. ALL WORK TO CONFORM TO GODES, ORDINANCES AND REGULATIONS OF THE CITY OF CARMEL, INDIANA AND OTHER AGENCIES AND AUTHORITIES HAVING JURISDICTION OVER PROJECT. 1. THE ARCHITECTURAL REFERENCE SITE PLAN GRAPHICALLY INDICATES THE APPROXIMATE LOCATIONS OF THE IMPROVEMENTS. REFER TO CIVIL ENGINEERS PLANS FOR ALL HORIZONTAL DIMENSIONAL CONTROL. 2. VERIFY ALL SITE DIMENSIONS ON CIVIL DRAWINGS, CONDITIONS, EXISTING CONSTRUCTION GRACES AND UTILITIES ON PROJECT AND CONTRACT DOCUMENTS AT PROJECT SITE PRIOR TO BEGINNING CONSTRUCTION, DISCREPANCIES TO BE REPORTED TO OWNED; AND ARCHITECT FOR CLARIFICATION. 5. WHEN EXGAVAT! FOR BUILDINGS OR EXCAVATING ACCESSORY THERETO, SUCH EXCAVATIONS SHALL BE MADE SAFE TO PREVENT ANY DANGER TO LIFE AND PROPERTY. 4. EXCAVATIONS FOR ANY PURPOSE SHALL NOT EXTEND WITHIN 1 FT. OF THE ANGLE OF REPOSE OR NATURAL SLOPE OF THE SOIL UNDER ANY FOOTING OR FOUNDATION, UNLESS :LUCH FOOTING OR FOUNDATION 15 FIRST PROPERLY UNDERPINNED OR PROTECTED AGAINST SETTLEMENT. 5. FOUNDATIONS SHALL BE BUILT ON UNDISTURBED SOIL OR PROPERLY COMPACTED FILL MATERIAL. 6. THE BOTTOM OF FOUNDATIONS SHALL EXTEND BELOW THE DEPTH OF FROST PENETRATION, BUT NO LESS THAN 12 INCHES BELOW FINISH GRADE. 7. FINISH GRADE SHALL BE SLOPED AWAY FROM THE FOUNDATION FOR DRAINAGE. S. FOUNDATION WALLS OR BEAMS SHALL EXTEND ABOVE THE FINISHED GRADE A MINIMUM OF 4 INCHES WHERE MASONRY VENEER IS USED AND A MINIMUM OF 6 INCHES ELSEWHERE. ARCHITECTURAL SYMBOLS: DRAWING TITLES: DRAWING NUMBER T i �I SECTION MARKERS: SHEET NUMBER DE TA IL AND FLAN MARKERS: DETAIL NUMBER SHEET NUMBER ELEVATION MARKERS: COLUMN AND C7RI D SYSTEM: SCALE B015141 SECTION NUMBER ELEV4sTION NUMB R(5) SHEET NUMBER AI00 FIRE RATING 1. FIRE RESISTIVE CONSTRUCTION SHALL BE MAINTAINED AT ALL PENETRATIONS FOR MECHANICAL, ELECTRICAL AND PLUMBING SYSTEMS AS REQUIRED S r THE JURISDICTIONAL AUTHORITIES OVER THE PROJECT. 2. ALL PARTITIONS ENCLOSING VERTICAL OPENINGS SUCH AS STAIRWAYS, UTILITY SHAFTS AND ELEVATOR SHAFTS WHICH ARE REQUIRED TO HAVE A FIRE RESISTANGE RATING SHALL EXTEND FROM FLOOR TO FLOOR OR FLOOR 10 ROOF. THESE WALLS SHALL BE CONTINUOUS THROUGH ALL CONCEALED SPACES SUCH AS THE SPACE ABOVE THE SUSPENDED CEILING. THE SUPPORTING STRUCTURE SHALL HAVE A FIRE RESISTANCE RATING EQUAL TO OR GREATER THAT THE FIRE RESISTANCE RATING REQUIRED FOR THE VERTICAL ENCLOSURE. WHERE T4E OPENINGS ARE OFFSET AT INTERMEDIATE FLOORS, THE OFFSET AND FLOOR CONSTRUCTION SHALL BE OF CONSTRUCTION HAVING A FIRE RESISTANCE 'F NOT LESS THAN THAT REQUIRED FOR THE ENCLOSING PARTITIONS. 3. CORRIDOR PARTITIONS, SMOKESTOP PARTITIONS, HORIZONTAL EXIT PARTITIONS, EXIT ENCLOSURES, AND FIRE RATED WALLS REQUIRED TO HAVE PROTECTED OPENINGS SHALL BE EFFECTIVELY AND PERMANENTLY I DENTI I ED WITH SIGNS OR STENCILING IN A MANNER ACCEPTABLE TO THE AUTHORITY HAVING JURISDICTION. SUCH IDENTIFICATION SHALL BE ABOVE ANY DECORATIVE CEILING AND I N CONGEALED SPACES. SUGGESTED V`iORD I NG: FIRE AND SMOKE B.'\RRI ER PROTECT ALL OPENINGS. FIREBLOCKING I. WALLS AND STUD PARTITIONS SHALL BE F I REBLOCKED AT FLOORS, CEILINGS AND ROOFS. F I REBLOCKI NG IN NONGOMSUSTI BLE PARTITIONS SHALL NOT SE REQUIRED AT THE CEILING FOR SUSPENDED CEILING SYSTEMS. FIREBLOGKING SHALL CONSIST OF APPROVED NONCOMBUSTIBLE MATERIALS UNLESS OTHERWISE SPECIFIED IN THIS CODE. MATERIAL SHALL SE SECURELY FASTENED IN PLACE. 2. F I REBLOCK I NG SHALL BE PROVIDED I N ALL. WALLS AND PARTITIONS TO CUT OFF ALL CONCEALED DRAFT OPENINGS BOTH HORIZONTAL AND VERTICAL AND TO FORM A FIRE BARRIER BETWEEN FLOORS AND BETWEEN THE UPPER FLOOR AND THE ROOF SPACE. 5. F I RESLOCKI NG SHALL NOT BE COVERED OR CONGEALED UNTIL INSPECTED BY THE BUILDING OFFICIAL. SPRINKLERS I. APPROVED EQUIPMENT AND LAYOUT. ONLY APPROVED SPRINKLERS AND DEVICES SHALL BE USED IN AUTOMATIC SPRINKLER SYSTEMS AND THE COMPLETE LAYOUT OF THE SYSTEM SHALL SE SUBMITTED TO THE BUILDING OFFICIAL FOR APPROVAL BEFORE INSTALLATION. 2. HOSE THREADS. ALL HOSE THREADS IN CONNECTIONS SHALL BE UNIFORM WITH THAT USED BY THE FIRE DEPARTMENT OF THE APPLICABLE GOVERNING BODY. DRAFTSTOPPI NG I. THE INTEGRITY OF ALL DRAFTSTOPS SHALL BE MAINTAINED. 2. DRAFTSTOPPING MATERIAL SHALL BE NOT LESS THAN 1/2 INCH GYPSUM BOARD, 15/52 INCH WOOD STRUCTURAL PANEL, 1/2 INCH PARTICLEBOARD OR OTHER MATERIAL APPROVED BY THE BUILDING OFFICIAL OR FIRE DEPAR`MENT. 3. DRAFTSTOPPING SHALL BE PROVIDED IN FLOOR /CEILING ASSEMBLIES ABOVE AND IN LINE WITH TENANT SEPARATION, WHEN TENANT SEPARATION WALLS DO NOT EXTEND TO THE FLOOR SHEATHING ABOVE. 4. CONTINUOUS EXTERIOR CORNICES OF WOOD, OR OF WOOD FRAMES, SHALL BE DRAFTSTOPPED AT INTERVALS NOT EXCEEDING 20 FT. 5. OVERHANGS TO BE DRAFTSTOPPED AT 20' -0" O.G. INTERVALS. 6. VENTILATION SHALL BE PROVIDED TO FURNISH GROSS VENTILATION OF EACH SEPARATE ATTIC SPACE WITH WEATHER PROTECTED VENTS. GLAZING I. EACH UNIT OF TEMPERED GLASS SHALL SE PERMANENTLY IDENTIFIED BY THE MANUFACTURER. M.E.P. 1. ALL HEATING, AIR CONDITIONING, REFRIGERATION, AND VENTILATION EQUIPMENT AND PLENUMS SHALL CONFORM TO THE REQUIREMENTS SET FORTH IN THE UNIFORM MECHANICAL CODE. 2. ALL ELECTRICAL SYSTEMS SHALL COMPLY WITH THE PROVISIONS OF NFPA 70. 3. ALL PLUMBING FIXTURES AND PLUMBING INSTALLATIONS SHALL CONFORM TO THE UNIFORM PLUMBING CODE. NORTH ARROW SYMBOLS: DOOR MARK WINDOW MARK KEY NOTE WALL TYPE MARK F FIRE EXTINGUISHER VERTICAL ELEVATION MARK A REVISION MARK 251.10 EXISTING SPOT ELEVATION 251.101 NEW SPOT ELEVATION DRAWING INDEX: COVER SHEET A000 GENERAL NOTES, DRAWING INDEX, ARCH. SYMBOLS CIVIL C101 TITLE SHEET C102 SPEC I F I GAT I ONS C103 SITE PLAN C104 SITE PLAN CI05 GRADING PLAN C106 GRADING PLAN G101 UTILITY FLAN 6108 UTILITY PLAN 010q EROSION CONTROL PLAN GII0 EROSION CONTROL PLAN G 1 1 1 SANITARY SEWER FLAN 4 PROFILE C112 SANITARY SEWER PLAN 4 PROFILE C113 SANITARY SEWER PLAN 4 PROFILE G114 ENTRANCE DETAILS C115 ENTRANCE DETAILS GI16 CONSTRUCTION DETAILS 0111 CONSTRUCTION DETAILS C118 CONSTRUCTION DETAILS G I 1 CONSTRUCTION DETAILS LI01 LANDSCAPE PLAN L102 LANDSCAPE FLAN L105 LANDSCAPE PLAN L104 LANDSCAPE PLAN LI05 LANDSCAPE FLAN ARCHITECTURAL 03/11/00 03/11/00 03 /11 /00 03/11/00 03/11/00 03/11/00 03/11/00 03/11/00 03/11/00 03/11/00 03/17/00 03/17/00 03/11/00 03/17/00 03/11/00 03/11/00 01/05/01 03/11/00 03/11/00 03/17/00 03/11/00 03/11/00 03/11/00 03/11/00 03/11/00 01 /05/01 A001 A002 A003 A004 A101 A102 A! 03 ARCHITECTURAL SITE PLAN PROJECT DATA AND CODE INFORMATION UNIT TABULATION AND SPECIFICATIONS ADDRESSING PLAN UNIT FLOOR PLANS UNIT A2 GARAGE UNIT FLOOR PLANS UNIT BI -1, UNIT BI -2 UNIT FLOOR PLANS UNIT B4, UNIT B4 -S A104 UNIT FLOOR PLANS UNIT Al, UNIT 136 A105 UNIT FLOOR PLANS UNIT A5 A106 UNIT FLOOR PLANS UNIT A5 -L A101 UNIT FLOOR PLANS UNIT ACI -I, GARAGE A105 UNIT FLOOR PLANS UNIT GI -2, UNIT A4 A10 UNIT FLOOR PLANS UNIT B -2 A110 UNIT FLOOR PLANS UNIT A3 -2, UNIT B3 AIII UNIT FLOOR PLANS UNIT A3 -I, UNIT B3 -I A112 UNIT FLOOR PLANS UNIT B3 -I -GAR, GARAGE A1I3 UNIT FLOOR PLANS UNIT 5-5 A114 UNIT FLOOR PLANS UNIT G -2 A20I A202a A202b A202c A203a A203b A204 BUILDING TYPE 1 FLOOR PLANS, ROOF FLANS BUILDING TYPE II FLOOR PLANS BUILDING TYPE I I FLOOR PLANS BUILDING TYPE II FLOOR PLANS, ROOF PLANS BUILDING TYPE 111 FLOOR PLANS BUILDING TYPE III FLOOR PLANS, ROOF PLANS BUILDING TYPE IV FLOOR PLANS, ROOF PLANS A205 BUILDING TYPE V FLOOR PLANS, ROOF PLANS A206 BUILDING TYPE VI FLOOR PLANS, ROOF PLANS A301 BUILDING TYPE 1 ELEVATIONS, DETAILS A302o BUILDING TYPE IIa ELEVATIONS, DETAILS A302b BUILDING TYPE IIb ELEVATIONS, DETAILS A303 BUILDING TYPE III ELEVATIONS, DETAILS A304 BUILDING TYPE IV ELEVATIONS, DETAILS A305 BUILDING TYPE V ELEVATIONS, DETAILS, SECTIONS A306 DETAIL ELEVATION, DETAILS A301 BUILDING TYPE VI ELEVATIONS, DETAILS, SECTIONS A401 SECTI DNS A402 SECTIONS A403 SECTIONS A404 SECTIONS A405 SECTIONS A406 SECT! DNS A501 STAIR SECTIONS BUILDING TYPE I A502 STAIR SECTIONS BUILDING TYPE II A503 STAIR SECTIONS BUILDING TYPE II A504a STAIR SECTIONS BUILDING TYPE III 4 IV A504b STAIR SECTIONS BUILDING TYPE III 4 iv A505 STAIR SECTIONS UNIT Al/B6, UNIT A5 -L A506 STAIR SECTIONS UNIT CI A601 LEASING CENTER FLOOR PLANS A602 LEASING CENTER ELEVATIONS, ROOF PLAN A603 LEASING CENTER WALL SECTIONS A604 LEASING CENTER WALL SECTIONS A605 LEASING CENTER WALL SECTIONS A606 POOL BUILDING A6II AMENITY PACKAGE FLOOR PLANS A612 AMENITY PACKAGE FLOOR PLANS A64I COMPACTOR FLOOR PLAN, ELEVATIONS, DETAILS FIRST ISSUE REVISION LAST ISSUE DATE: NUMBER: DATE: 03/11/00 03/11/00 03/08/00 03 /08 /oo 03/08 /00 03/08/00 03/08/00 03/08/00 03/08/00 03/08/00 03/08/00 03/08/00 03/08/00 03/08/00 03/08/00 03/08/00 03 /08/00 03/08/00 03/08/00 03/08/00 03/08/00 03/08/00 03/08/00 03/08/00 03/08/00 03/08/00 03/17/00 03/11/00 03/17/00 03/11/00 03/11/00 05/17/00 03/11/00 03/11/00 01 /05/01 03/17/00 03/11/00 03/I1/00 03/17/00 03/11/00 03/17/00 03/11/00 03/17/00 03/11/00 03/17/00 03/11/00 03/11/00 03/11/00 03/17/00 03/17/00 03/11/00 03/17/00 03/11/00 03/11/00 03/11/00 03/11/00 A62I 6 GAR GARAGE FLOOR PLAN, ELEVATIONS, DETAILS 03/11/00 A622 5 GAR GARAGE FLOOR PLAN, ELEVATIONS, DETAILS 03/11/00 A63I MA I TENANCE BUILDING FLOOR PLAN, ROOF PLAN, DTLS. 03/11/00 A632 MAINTENANCE BUILDING FLOOR PLAN, ROOF PLAN, DTLS. 03/11/00 03/11/00 01/02/01 01/02/01 01/02/01 01/02/01 08/11/00 07/14/00 01/14/00 07/14/00 07/14/00 07/14/00 07/14/00 07/14/00 07/14/00 07/14/00 07/14/00 07/14/00 07/14/00 07/14/00 01/02/01 07/14/00 07/14/00 07/14/00 07/14/00 07/14/00 07 /I4 /oo 07/14/00 07/14/00 01/02/01 07/14/00 07/14/00 07/14/00 07/14/00 07/14/00 07/14/00 07/14/00 01/02/01 07/14/00 07/14/00 07/14/00 07/14/00 07/14/00 07/14/00 07/14/00 07/14/00 07/14/00 07/14/00 07/14/00 07/14/00 07/14/00 07/14/00 07/14/00 07/14/00 07/14/00 07/14/00 0 07/14/00 07/14/00 07/14/00 07/14/00 07/14/00 07/14/00 UI U2 El ES E7 E8 Eq Ell HARDSCAPE A101 HARDSCAPE REFERENCE SITE PLAN A102 POOL HARDSCAPE PLAN A103 MISC. HARDSCAPE PLANS A104 MISC. HARDSCAPE PLANS A105 HARDSCAPE DETAILS AND ELEVATIONS A106 MONUMENT SIGN PLANS, ELEVATIONS, 4 DETAILS A101 BUS KIOSK FLAN, ELEVATIONS, 4 DETAILS A108 TRASH GOMPA::TOR AND REGYGL I NG AREA STRUCTURAL 03/11/00 03/11/00 03/17/00 03/11/00 03/I 1/00 03/11/00 03 /I 1/00 03/11/00 03/11/00 03/11/00 03/11/00 03/I 1/00 01/02/01 5101 TITLE SHEET 5201 TYPE 1 FRAMING 4 FOUNDATION PLANS 5202o TYPE I IA 4 115 FOUNDATION FLANS 5202b TYPE I I A 4 1 I S- FRAM I NG PLANS S202c TYPE IIA 4 115 FRAMING PLANS 5203a TYPE III FRAMING 4 FOUNDATION PLANS S203b TYPE III FRA`4I NG PLANS 5204 TYPE IV FRAMING 4 FOUNDATION PLANS TYPE V FRAMING FOUNDATION PLANS 5205 S206 LEASING CENTER FRAMING 4 FOUNDATION FLANS 5207 GARAGES P._ANS AND DETAILS 5208 POOL HOUSE FLANS AND DETAILS 520 TYPE VI FRA' 1 I NG 4 FOUNDATION PLANS MECHANICAL PLUMBING PI P2 PLUMBING PLAN TYPE II P3 PLUMBING PLAN TYPE I I I P4 PLUMBING PLAN TYPE IV P5 PLUMBING PLAN: TYPE V P6 P1 Pq MI Eq PLUMBING PLAN TYPE 1 PLUMBING PLAN LEASING CENTER PLUMBING PLAN AMENITY PLAN PS PLUMBING PLAN MAINTENANCE BUILDING PLUMBING SPECIFICATIONS HVAG PLAN UNITS M2 HVAG PLAN UNITS M3 HVAG PLAN LEASING CENTER M4 HVAG PLAN MAINTENAGE BUILDING M5 HVAG PLAN AMENTI TY BUILDING M6 HVAG PLAN UNIT 02 LEASING CENTER LIGHTING PLAN ELECTRICAL UTILITY SITE PLAN UTILITY SITE PLAN E4 SCHEDULES 4 LEGENDS CIRCUIT SCHEDULES ELECTRICAL FLAN UNITS E2 ELECTRICAL PLAN UNITS ES ELECTRICAL FLAN UNITS ELECTRICAL .SPECIFICATIONS 4 DETAILS E6 ELECTRICAL PLAN BUILDING TYPE I, IV 4 V ELECTRICAL FLANS BUILDING TYPE IIB 4 III LEASING CENT:7 LIGHTING PLAN E I O LEASING CENTER POWER PLAN MAINTENANCE BUILDING 4 GARAGE PLANS E12 AMENITY BUILDING LIGHTING 4 POWER PLAN EIS ELECTRICAL PLAN UNIT 02 FIRST ISSUE REVISION LAST ISSUE DATE: NUMBER: DATE: 06/01/00 06/01/00 3 0°1/11/00 06/01/00 2 08/11/00 06/01/00 06/01/00 06/01/00 2 08 /I 1/00 06/01/00 2 05/11/00 06/01/00 03/15/00 03/15/00 03/15/00 03/15/00 03/15/00 03/15/00 03/15/00 03/15/00 03/15/00 03/15/00 03/15/00 03/15/00 03/15/00 03/15/00 01/02/01 01/26/00 01/26/00 01/26/00 01/26/00 01/26/00 01/26/00 01/26/00 01/26/00 01/26/00 01/26/00 01/26/00 01/26/00 01/26/00 01/26/00 01/26/00 07/02/01 2 05/11/00 Looney Ricks Kiss Architecture Planning Interiors Research 175 Toyota Plaza, Suite 600 Memphis, Tennessee 38103 Telephone 901 521 1440 Fax 901 525 2760 E -mail info @Irk.com Multi Family Plan for: Providence Housing Partners, L.L.C. 333 North Pennsylvania Street Indianapolis, Indiana 46204 Issues and Revisions No. Date Issues and Revisions 01 12.10.1999 Design Development Set 02 01.20.2000 Progress Set #01 03 02.24.2000 Progress Set #02 04 03.17.2000 Permit Set Seal Project Name: Carmel, Indiana Drawing Name: Drawn By: 07.14.2000 Revision #01 08.11.00 Revision #02 09.11.00 Revision #03 07.02.2001 Revision #04 General Notes Drawing Index Checked By: jr t �,'`yo, P tntlt0 p11'4 t N4 P1940 sa,sb 41 '%RCH II" ��`��r�rtiutt�«na Project Number: 01.98393.00 Architectural Symbols Providence at Old Meridian A000 2 •.•16 i .0 2000 Looney Ricks Kiss Architects, Inc. Drawings, written material, and design concepts shall not be used or reproduced in whole or part in any form or format without prior written consent of Looney Ricks Kiss Architects, Inc. Do not scale drawings. Use given dimensions only. If not shown, verify correct dimensions with the Architect. Contractor shall check and verify all dimensions and conditions at job site. INV 'wain