HomeMy WebLinkAbout0935.00cBUS KIOSK
OCCUPANCY U
CONSTRUCTION TYPE V -N
SPR I NKLERED NO
ALLOWABLE HE I GHT 1-STORY 20' -0"
ACTUAL HE I GHT I -STORY
ALLOWABLE AREA 1,000 S.F. /FLOOR
ACTUAL AREA 140 S.F.
BUILDING TYPE
BUILDING NO. 3, 4, 6, 7, 8, 10, 11, 26, 27
OCCUPANCY R-I TYPE V -I -HR
FIRE SPRINKLER SYSTEM YES, NFIPA I3R
ALLOWABLE HEIGHT
ACTUAL HE I GHT
HEIGHT TO EAVE
ALLOWABLE AREA 10,500 S.F./FLOOR
TOTAL ALLOWABLE AREA 21,000 S.F.
ACTUAL AREA
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
TOTAL AREA
54
THIRD FLOOR
1
E34
SECOND FLOOR
B4
FIRST FLOOR
0
A2
A2
BI
BI
BI
0
3 -STORY
3 -STORY
5,540 S.F
5,430 S.F.
5,430 S.F.
16,400 S.F.
A2
A2
0
54
B4
B4
50' 0"
38' -10"
31' -10"
DETAGHED GARAGES
OCCUPANCY U, PRIVATE GARAGE
CONSTRUCTION TYPE V -N
FIRE SPRINKLER SYSTEM NO
ALLOWABLE HE 1 GHT I -STORY 20' 0"
ACTUAL HE I GHT 1-STORY 13' -8"
ALLOWABLE AREA 3,000 5.F ./FLOOR
ACTUAL AREA
6 -GAR GARAGE
5 -GAR GARAGE
BUILDING TYPE Ila
BUILDING NO. 2
OCCUPANCY :R-1
CONSTRUCTION TYPE V-1 -HR
FIRE SPRINKLER SYSTEM YES, NFIPAI3R AT 2nd AND 5rd FLOOR
NFi PA 13 AT 1st FLOOR
ALLOWABLE HEIGHT 5 -STORY 50' -0"
ACTUAL HEIGHT 3 -STORY 40' -10"
HEIGHT TO SAYE 32' -10"
ALLOWABLE AREA 10,500 S.F./FLOOR
OPEN 3 SIDES INCREASE (51 I/2 6,0515.F /FLOOR
ALLOWABLE AREA FLOOR 16,537 S.F./FLOOR
TOTAL ALLOWABLE AREA 53,014 S.F.
4 MIN. SIDE YARD 43' (23' OVER 20' MIN)
INCREASE 23 X 2 -1/2" 51 I/2% INCREASE
ACTUAL AREA
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR (INC. MEZ.)
TOTAL AREA
A5 -L
A5 •L
THIRD FLOOR
A5
A5
SECOND FLOOR
FIRST FLOOR
E36
E36
E36
A5 -L
A5
5,ci 1 S.F.
5,103 S.F.
10,052 S.F.
25,554 S.F.
1,564 S.F.
1,305 S.F.
A5 -L
AS
B6
B6
B6
B6
56 56
A5 -L
AS
A5 -L
A5
ASSEMBLY /BUSINESS SPACES
8,282 S.F.
B6
B6
E36
A5 -L
AS
A5 -L
AS
AS
MAINTENANCE BUILDI
OCCUPANCY 5 -3,U -I
CONSTRUCTION TYPE V -N
FIRE SPRINKLER SYSTEM: NO
ALLOWABLE HEIGHT
ACTUAL HEIGHT
ALLOWABLE AREA
ACTUAL AREA
PER 504.2.2 SPRINKER SYSTEM NOT RE0'2 WHEN
AT LEAST 20 5.F. OPENING PER 50 LINEAR FEET
ON AT LEAST ONE SIDE
BUILDING TYPE I
BUILDING NO. 1, 5, 2g
OCCUPANCY R -I
CONSTRUCTION TYPE V- I -HR
FIRE SPRINKLER SYSTEM YES, NF IPA I3R
ALLOWABLE HEIGHT
ACTUAL HEIGHT
HEIGHT TO EAVE
ALLOWABLE AREA
OPEN 3 SIDES INCREASE (51 I/2%)
ALLOWABLE AREA FLOOR
TOTAL ALLOWABLE AREA 35,074 S.F.
1E MIN. SIDE YARD 43' (23' OVER 20' MIN.)
INCREASE 23 X 2 -1/2" 51 I/2% INCREASE
ACTUAL AREA
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR (INC. MEZ.)
TOTAL AREA
A5 -L
A5 -L
THIRD FLOOR
AS
AS
SECOND FLOOR
A5
A5
FIRST FLOOR
56
56
Al
56
A5 -L
AS
A5
2 -STORY 40' -0"
I -STORY 14' -3"
8,000 S.F./FLOOR
1,564 S.F. U -I
1,428 S.F. S -3
2,5x2 S.F. TOTAL
3 -STORY
5 -STORY
5,775 S.F.
5,503 S.F.
10,052 S.F.
25,730 S.F.
A5 -L
A5
AS
B6
50' 0"
40' -10"
32' -10"
10,500 S.F. /FLOOR
6,0515.F ./FLOOR
16,551 S.F. /FLOOR
E36
56
Al
56
56
Al
56
A5 -L
AS
A5
A5 -L
AS
AS
56
B6
56
Al
A5 -L
AS
A5
A5 -L
AS
A5
CLUBHOUSE
OCCUPANCY A -3, ASSEMBLY
GONSTRUGTION TYPE V -N
FIRE SPRINKLER SYSTEM NOT REQUIRED PER 504.2.2
ALLOWABLE HEIGHT 1 -STORY 40' 0"
ACTUAL HEIGHT 1-STORY 25
HEIGHT TO EAVE 22
ALLOWABLE AREA
ACTUAL AREA
BUILDING TYPE
BUILDING NO. 12,13, 14, 16, IS, 20, 21, 23
OCCUPANCY R -I
CONSTRUCTION TYPE V -I -HR
FIRE SPRINKLER SYSTEM YES, NFIPA I SR
ALLOWABLE HE I GHT
ACTUAL HEIGHT
HEIGHT TO EAVE
ALLOWABLE AREA 10,500 S.F./FLOOR
TOTAL ALLOWABLE AREA 21,000 S.F.
ACTUAL AREA
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR (INC. MEZ)
TOTAL AREA
ALLOWABLE AREA AT BLDG #14 10,500 S.F./FLOOR
OPEN 3 SIDES INCREASE (45 4,725 S.F./FLOOR
ALLOWABLE AREA FLOOR AT BLDG #I4 15,225 S.F./FLOOR
TOTAL ALLOWABLE AREA AT BLDG #I4 50,450 S.F.
MIN. SIDE YARD 58' (18' OVER 20' MIN.) NOTE: 2 -HR FIRE SEP. ASSEMBLY
INCREASE 18 X 2 -1/2" 45% INCREASE NOT REQUIRED AT BLDG #I4
THIRD FLOOR
B3
83
E35
A3
SECOND FLOOR
AS
FIRST FLOOR
AREA A
2 -HOUR F IRE
SEPARATION
ASSEMBLY
A4
52
52
2 -HOUR FIRE
SEPARATION
ASSEMBLY
GI
6,000 S.F.
2,4I1 S.F.
3 -STORY
3 -STORY
5, ?40 S.F.
5,534 S.F.
5,112 S.F.
28,386 S.F.
2 -HOUR FIRE
SEPARATION
ASSEMBLY
G
50' 0"
55
51' -6"
82
52
GI
GI
A4
AREA A
4,870 S.F.
4,767 S.F.
4,556 S.F.
14,153 S.F. 14,1 53 S.F.
AREA B
A3
A3
A3
AREA B
4,870 S.F.
4,767 S.F.
4,556 S.F.
B3
53
55
CONSTRUCTION SUMMARY
ELEMENT OF CONSTRUCTION (TYPE V -I HOUR) FIRE RATING
EXTERIOR LOAD BEARING WALLS
EXT. NON -LOAD BEARING WALLS
AREA SEPARATION WALL
WALL AT EXIT
OPENINGS AT EXIT ENCLOSURE
OPENINGS AT R-I UNIT /GARAGE
OPENINGS AT R -3 UNIT /GARAGE
ENCLOSURE AT SHAFTS
MIXED USE OCCUPANCY SEPARATION
WALL AT TENANT SEPARATION
WALL AT UNIT SEPARATION
OTHER NON -LOAD BEARING PARTITIONS
INT. NON -LOAD BEARING PARTITIONS
STRUGT. MEMBERS SUPPORTING WALLS
FLOOR CEILING ASSEMBLY AT UNITS
FLOOR -GE I L I NG ASSEMBLY AT BREEZEWAY
ROOF -GE IL I NG ASSEMBLY
FLOOR CEILING ASSEMBLE AT DECKS
GARAGE UNIT SEPARATION I -HR
BUSINESS UNIT SEPARATION IHR
ASSEMBLY UNIT SEPARATION IHR
BUILDING TYPE I Y
5UILDING NO. CI, 15, 17, I 'I, 22, 24, 25, 28
OCCUPANCY R -1
CONSTRUCTION TYPE V -I
FIRE SPRINKLER SYSTEM
ALLOWABLE HE I GHT
ACTUAL HEIGHT
HEIGHT TO EAVE
ALLOWABLE AREA
TOTAL ALLOWABLE AREA
ACTUAL AREA
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
TOTAL AREA
155
THIRD FLOOR
83
B3
0
FIRST FLOOR
A3
A3
SECOND FLOOR
0
-HR
YES, NFIPA 13R
3 -STORY
3 -STORY
10,500 S.F. /FLOOR
21,000 S.F.
4,402 S.F.
4,428 S.F.
4,226 S.F.
13,056 S.F.
A3
A3
B3
53
53
50' O"
3 'I' -3"
31' -10"
I -HR
I-HR
2 -HR
-HR
-HR
I-HR
20 MIN.
I-HR
I-HR
I -HR
0
0
I-HR
I -HR
I-HR
I-HR
I -HR
GODS I N FORGE
Ig18 INDIANA BUILD INS CODE
1 "7 I ND I ANA ONE it TWO FAMILY DWELLING CODE
I ota I ND I ANA MECHANICAL CODE
Ig 11 INDIANA PLUMBING CODE
1 580 CARMEL /CLAY ZONING ORDINANCE
AMERICANS WITH DISABILITIES ACT ACCESSIBILITY
GUIDELINES, 28GFR, PART 36, APPENDIX A
FAI RHOUS I NG ACCESS I B I LTY GUI DEL I NES,
24 CFR, CHAPTER I
1581 INDIANA SWIMMING FOOL CODE
1553 INDIANA ENERGY GONSERVATI ON CODE
BUILDING TYPE V
BUILDING NO. 001, 502, W5, 0l0
OCCUPANCY R -3
CONSTRUCTION TYPE V -N
FIRE SPRINKLER SYSTEM
ALLOWABLE HEIGHT
ACTUAL HEIGHT
HE I GHT TO EAVE
ALLOWABLE AREA
TOTAL ALLOWABLE AREA UNLIMITED
ACTUAL AREA
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
TOTAL AREA
FIRST FLOOR
E35
THIRD FLOOR
SECOND FLOOR
v v v
NO
155
3 -STORY
3 -STORY
UNLIMITED
1,808 S.F.
1,7g6 S.F.
738 S.F.
4,342 S.F.
B5
B5
40' 0"
30' -5"
BUILDING TYPE VI
BUILDING NO. CO5, 004, 006
OCCUPANCY R -3
CONSTRUCTION TYPE V -N
FIRE SPRINKLER SYSTEM NO
ALLOWABLE HEIGHT
ACTUAL HE I GHT
HEIGHT TO EAVE
ALLOWABLE AREA
TOTAL ALLOWABLE AREA UNLIMITED
ACTUAL AREA
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
TOTAL AREA
3 -STORY
3 -STORY
UNLIMITED
1,808 S.F.
1,756 S.F.
1,182 S.F.
4,706 S.F.
40' -0''
30 -S
23' -ci"
THIRD FLOOR
SECOND FLOOR
G2
G2
G2
G2
FIRST FLOOR
Looney Ricks Kiss
Architecture Planning Interiors Research
175 Toyota Plaza, Suite 600
Memphis, Tennessee 38103
Telephone 901 521 1440
Fax 901 525 2760
E -mail info @lrk.com
Multi Family Plan for:
Providence Housing Partners, L.L.C.
333 North Pennsylvania Street
Indianapolis, Indiana 46204
Issues and Revisions
No. Date Issues and Revisions
01 12.10.1999 Design Development Set
02 01.20.2000 Progress Set #O1
03 02.24.2000 Progress Set #02
04 03.17.2000 Permit Set
A 07.14.2000 Revision #01
n 07.02.2001 Revision #04
2000 Looney Ricks Kiss Architects, Inc.
Drawings, written material, and design concepts shall not be used
or reproduced in whole or part in any form or format without prior
written consent of Looney Ricks Kiss Architects, Inc. Do not scale
drawings. Use given dimensions only. If not shown, verify correct
dimensions with the Architect. Contractor shall check and verify all
dimensions and conditions at job site.
Seal
Project Name:
Carmel, Indiana
Drawing Name:
Code Summary
Drawn By: sa,jr
Checked By: jr
a
(NQ 8194 361
E OF 1
14
S. +4� cHITES
Project Number: 01.98393.00
Providence at Old Meridian
A002