HomeMy WebLinkAbout0935.00fVENTILATION
TOTAL REQUIRED: 868 SQ.IN. MIN. RECD.
RIDGE VENTS =16' 16 SQ.I N. /FT. 256
SOFFIT VENT= 105' 24 SQ.I N. /FT. 2520
TOTAL SHOWN 2776 SQ.IN.
1
TYPICAL ROOF
SYSTEM
20 GAUGE METAL EDGE
FLASHING W/ DRIP
PROFILE, TYP.
1x4 FASCIA
UNIT G -2
15CD1R00`/1 #5
GYPSUM BD.
23/32 O.S.B. DECKING
ON WOOD TRUSSES
R -I3 WALL INSULATION
Atv AVM AvAvAv 1111
1/2" GYPSUM BD.
23/32 O.S.B. DECKING
ON WOOD FLOOR TRUSSES
UNIT G -2
L I �l I NG R0 0N(
R -33 ATTIC INSULATION
ABOVE CONDITIONED
SPACE
SLOPE PER FOOT
2x8 TRIM
GEMENTI TI OUS
PANEL SIDING
NO JOINTS ALLOWED
26 GAUGE
METAL FLASHING
1x4 /2x10 TRIM
SCHEDULED WINDOW
2x6 TRIM
26 GAUGE GALV.
METAL FLASHING
TYPICAL ROOF SYSTEM
SCHEDULED WINDOW
ROWLOCK COURSE
SLOPE 1/4"
BRICK VENEER
METAL FLASHING
6" UP WALL MIN.
TYP. ROOF
2 X 6 FASCIA
2 X 6 RAFTERS
4 -0" O.G.
KING SIZE
BRICK SOLDIER COURSE
PROJECT 3 /8"
WEEP HOLES AT 24" O.G.
20 MIL MEMBRANE
FLASHING. TYP.
R -Ici INSULATION
ABOVE GARAGE
I LAYER 5/8" TYPE X
GYPSUM BD. AT WALLS
IN GARAGE
12
12
I LAYER 5 /8"
GYPSUM BD. TYPE X
ON CHANNELS
AT CEILING
I N GARAGE
12
12
R -33 INSULATION
12
12
qii
J
TYPICAL ROOF SYSTEM:
COMPOSITE SHINGLES ON
I5# FELT ON DECKING PER
STRUCTURAL ENGINEER
26 GAUGE METAL. EDGE
FLASHING W/ DRIP
PROFILE, TYP.
2 X 6 FASCIA
—B.C. PLYWOOD SOFFIT
1x4 TRIM ON IxlO TRIM,
3/4" OVERLAP
CONTINUOUS PANEL MOULD
1x8 TRIM
1/2" SHEATHING
IX W0017 TRIM GUT TO
FIT, 3/4" DRIP
3/8" GDX PLYWOOD SOFFIT
8" ALUMINUM
LOAD BEARING COLUMN
1x6 CORNER TRIM
BEYOND
SIDING ON SHEATHING,
RE: ELEV. FOR SIZE O
42" HIGH VINYL
GUARDRAIL
MINIMUM 11/2"
LIGHTWEIGHT CONCRETE,
SLOPE TO DRAIN, OVER
BI TUTHENE FLASHING
GALV. METAL EDGE TOP OF 'I
FLASHING BALCOr
DEGKINt._
1x4 TRIM ON Ix8 TRIM,
3/4" OVERLAP
ONTINUOUS PANEL MOULD
1x6 TRIM
3/8" GDX PLYWOOD SOFFIT
HEEL AT
BALCONY
w
w
2
(Y TOP OF
1- SUBFLOOR
O
9
TOP OF
PLATE
O
O
TOP OF
SUBFLOOR
TOP OF
PLATE
i
SCALE 1 4" 1' -0"
BUILDING TYPE VI ROOF PLAN
II II
L-- --�J
UNIT
rev
0
L
-DRAFT STOPPING
BUILDING TYPE VI -THIRD FLOOR PLAN
SCALE 1 4 r_o..
1
NOTE: ALL SOFFIT VENTS SHOWN ARE BASED ON A 2"
CONTINUOUS SOFFIT
ALL RIDGE VENTS SHO ARE BASED ON AMPCOR
UNIVERSAL ALUMINUM RIDGE VENT -16 SQ.IN. /LIN.FT.
ALL GABLE VENTS ARE DECORATIVE.
PAINT ALL ROOF ACCESSORIES TO MATCH ROOF
COLOR A.
-r
II II
TI II—
11 -4
UNI
G2
r
b6- rp.dwg
b6 -f p3.dwg
R
Looney Ricks Kiss
Architecture Planning Interiors Research
175 Toyota Plaza, Suite 600
Memphis, Tennessee 38103
Telephone 901 521 1440
Fax 901 525 2760
E -mail info@Irk.com
Multi Family Plan for:
Providence Housing Partners, L.L.C.
333 North Pennsylvania Street
Indianapolis, Indiana 46204
Issues and Revisions
No. Date Issues and Revisions
07.02.2001 Revision #04