HomeMy WebLinkAbout0935.00iBEARING WALL FRAMING SCHEDULE MARK STUD SPACING SPECIES "A" 2x4 16" O.C. SPF, STUD GRADE OR BETTER "B" 2x4 12" O.C. SPF, STUD GRADE OR BETTER "C" 2x4 12" O.C. SPF, #1/#2 GRADE OR BETTER "D" DBL. 2x4 16" O.C. SPF, STUD GRADE OR BETTER "E" DBL. 2x4 12" O.C. SPF, STUD GRADE OR BETTER "F" TRPL. 2x4 16" O.C. SPF, STUD GRADE OR BETTER "G" 2x6 16" O.C. SPF, STUD GRADE OR BETTER DOOR /WINDOW HEADER SCHEDULE MARK MATERIALS H1 (2) 2x10 WITH 1/2" PLYWOOD (SP NO. 1 OR NO. 2) H2 (2) 2x12 WITH 1/2" PLYWOOD (SP NO. 1 OR NO. 2) H3 3-1/2"x9 -1/4" PSL OR LVL LUMBER (2.OE) H4 3 -1/2 "x11 -1/4" PSL OR LVL LUMBER (2.OE) H5 3- 1/2 "x14" PSL OR LVL LUMBER (2.OE) F6.0 6' -0" x 6' -0" x 16" SPREAD FOOTING SCHEDULE MARK FTG. SIZE REINFORCEMENT F3.0 3' -0" x 3' -0" x 12" (3) #5 E.W. F4.0 4' -0" x 4' -0" x 12" (4) #5 E.W. F5.0 5-0" x 5' -0" x 12" (6) #5 E.W. F6.0 6' -0" x 6' -0" x 16" (7) #5 E.W. (4) 3/4 "0 A307 BRICK LINTEL SCHEDULE MARK CLEAR OPENING STEEL ANGLE BL1 UP TO 5-0" L 3 1/2 x 3 1/2 x 5/16 BL2 5-1" TO 7-0" L 5 x 3 1/2 x 5/16 (LLV) BL3 7' -1" TO 10'-0" L 6 x 3 1/2 x 3/8 (LLV) TS5 TS5x5x 1 /4 3/4 "x 11 "x 11 (4) 3/4 "0 A307 COLUMN SCHEDULE MARK SIZE BASEPLATE ANCHOR BOLTS TS3 TS3x3x5/16 3/4 "x9 "x9" (4) 3/4 "0 A307 TS4 TS4x4x 1 /4 3/4 "x 10 "x 10" (4) 3/4 "0 A307 TS5 TS5x5x 1 /4 3/4 "x 11 "x 11 (4) 3/4 "0 A307 CONCRETE PIER SCHEDULE MARK PLAN DIMENSIONS REINFORCEMENT P12 12" x 12" (4) #6 VERT., #3 TIES WF24 2' -0 "x30" (2) #5 CONT. TRENCH FOOTING SCHEDULE MARK FTG. WIDTH THK. REINFORCEMENT WF16 1' -4 "x30" (2) #5 CONT. WF24 2' -0 "x30" (2) #5 CONT. STRUCTURAL GENERAL NOTES; 1. GENERAL CONDITIONS: A. IT IS THE CONTRACTOR'S RESPONSIBILITY TO COMPLY WITH ALL APPUCABLE CODES, ORDINANCES, RULES, REGULATIONS,STANDARDS AND SAFETY PRECAUTIONS. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK AND SHALL. BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, PROCEDURES AND SEQUENCE. B. THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AS MAY BE SHOWN OR REFERENCED IN THE DRAWINGS AND SPECIFICATIONS AND BEFORE PROCEEDING WITH THE WORK SHALL REPORT TO THE ENGINEER ANY VARIATIONS RELATIVE TO EXISTING CONDITIONS THAT MAY MATERIALLY AFFECT THE WORK. C. THE STRUCTURE HAS BEEN DESIGNED FOR IN- SERVICE LOADS ONLY AND THE STRUCTURAL DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED STRUCTURE. LOADING APPLIED TO THE STRUCTURE DURING THE PROCESS OF CONSTRUCTION SHALL NOT EXCEED THE SAFE LOAD- CARRYING CAPACITY OF THE STRUCTURAL MEMBERS AND SHALL NOT BE APPLIED UNTIL STRUCTURAL COMPONENTS ARE PROPERLY CONNECTED TOGETHER AND UNTIL ALL TEMPORARY BRACING IS IN PLACE. D. THE CONTRACTOR SHALL PROVIDE ALL TEMPORARY GUYING AND BRACING REQUIRED TO ERECT AND HOLD THE STRUCTURE IN PROPER ALIGNMENT UNTIL ALL STRUCTURAL WORK AND CONNECTIONS HAVE BEEN COMPLETED. THE INVESTIGATION, DESIGN, SAFETY, ADEQUACY AND INSPECTION OF ERECTION BRACING, SHORING, TEMPORARY SUPPORTS, ETC. IS THE SOLE RESPONSIBIUTY OF THE CONTRACTOR. E. THE CONTRACTOR SHALL PROVIDE TEMPORARY SHORING AND RELATED PROTECTION AS NECESSARY TO PREVENT DAMAGE TO EXISTING MATERIALS, SURFACES, AND SYSTEMS THAT ARE TO REMAIN. F. THE STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH THE DRAWINGS OF ALL OTHER DISCIPUNES AND THE SPECIFICATIONS. THE CONTRACTOR SHALL VERIFY THE REQUIREMENTS OF OTHER TRADES AS TO SLEEVES, CHASES, HANGERS, INSERTS, ANCHORS, HOLES AND OTHER ITEMS TO BE PLACED OR SET IN THE STRUCTURAL WORK AND SHALL COORDINATE SAME. G. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT SPECIFICALLY SHOWN, SIMILAR DETAILS OF CONSTRUCTION SHALL BE USED, SUBJECT TO APPROVAL BY THE ENGINEER. REFER TO THE PROJECT SPECIFICATIONS FOR DETAILED MATERIAL AND INSTALLATION REQUIREMENTS. 2. SHOP DRAWINGS AND SUBMITTALS: A. SHOP DRAWINGS AND RELATED ITEMS SHALL BE SUBMITTED TO THE ENGINEER FOR REVIEW PRIOR TO FABRICATION. ALL SHOP DRAWINGS SHALL BE REVIEWED BY THE GENERAL CONTRACTOR BEFORE SUBMITTAL. 8. THE ENGINEER'S REVIEW IS TO BE FOR CONFORMANCE WCTH THE DESIGN CONCEPT AND GENERAL COMPLIANCE WITH THE RELEVANT CONTRACT DOCUMENTS. C. THE ENGINEER'S REVIEW DOES NOT RELIEVE THE CONTRACTOR OF SOLE RESPONSIBILITY TO REVIEW, CHECK AND COORDINATE THE SHOP DRAWINGS PRIOR TO SUBMISSION. THE CONTRACTOR REMAINS SOLELY RESPONSIBLE FOR ERRORS AND OMMISStONS ASSOCIATED WITH THE PREPARATION OF SHOP DRAWINGS AS THEY PERTAIN TO MEMBER SIZES, DETAILS, DIMENSIONS, MATERIAL QUALITY, QUANTITY, ETC. D. SUBMIT SHOP DRAWINGS IN THE FORM OF TWO BLUELINE PRINTS AND ONE REPRODUCIBLE. 3. CODE SPECIFICATION REFERENCES: UBC UNIFORM BUILDING CODE ACI AMERICAN CONCRETE INSTITUTE AISC AMERICAN INSTITUTE OF STEEL CONSTRUCTION AISI AMERICAN IRON AND STEEL INSTITUTE AWS AMERICAN WELDING SOCIETY CRSI CONCRETE REINFORCING STEEL INSTITUTE PCA PORTLAND CEMENT ASSOCIATION 4. BUILDING CODE: 1997 UBC WITH 1998 INDIANA AMENDMENTS 5. DESIGN LOADS: DEAD LOADS FLOOR UVE LOAD: FLOOR UVE LOAD: FLOOR LIVE LOAD: CORRIDOR LIVE LOAD: ROOF SNOW LOAD: WIND LOAD: SEISMIC LOAD: 10. MINIMUM COVER FOR STEEL REINFORCEMENT: FOOTINGS 3 INCHES PIERS 2 INCHES SLAB -ON -GRADE MID -DEPTH OF SLAB MATERIAL WEIGHTS 40 PSF (DWELLING UNITS) 60 PSF (EXTERIOR BALCONIES)) 125 PSF (STORAGE MECH. ROOMS) 100 PSF 20 PSF DRIFTING 75 MPH, EXPOSURE B ZONE 1, OCCUPANCY i{I GEOTECHNICAL NOTES; 1. PRIOR TO BEGINNING EARTHWORK, REVIEW THE SUBSURFACE INVESTIGATION AND FOUNDATION RECOMMENDATIONS PREPARED BY ALT WITZIG, INC., A&W PROJECT NO. S0119- S -IN29, DATED FEBRUARY 28, 2000. 2. ALLOWABLE SOIL BEARING PRESSURES: A. BUILDINGS #14 THROUGH #23: SPREAD COLUMN FOOTINGS 1,500 PSF CONTINUOUS WALL FOOTINGS 1,500 PSF B. ALL OTHER BUILDINGS SPREAD COLUMN FOOTINGS 3,000 PSF CONTINUOUS WALL FOOTINGS 2,400 PSF 3. PLACE ALL FOUNDATIONS AND GRANULAR FILL FOR SLABS -ON- GRADE ON FIRM UNDISTURBED SOIL OR ENGINEERED FILL IN ACCORDANCE WITH THE SOILS REPORT. 4. RETAIN THE SERVICES OF THE SOILS ENGINEER TO MONITOR EXCAVATION AND BACKFILLING OPERATIONS AND TO TEST BEARING CONDITIONS PRIOR TO PLACEMENT OF CONCRETE. 5. FURNISH TO THE ENGINEER A REPORT, CERTIFIED BY THE SOILS ENGINEER, VERFIFYING THAT ALL FOUNDATIONS WERE PLACED ON MATERIAL CAPABLE OF SUSTAINING THE DESIGN BEARING PRESSURE. CAST -IN -PLACE CONCRETE NOTES; 1. CONCRETE 28 DAY COMPRESSIVE STRENGTH AND AIR ENTRAINMENT REQUIREMENTS: A. WALL FOOTINGS, SPREAD FOOTINGS, ALL CONCRETE BELOW FROST LINE NORMAL WEIGHT, 3,000 PSI, 2% AIR. B. EXTERIOR SLABS, PIERS, ALL CONCRETE EXPOSED TO FREEZE/THAW CONDITIONS NORMAL WEIGHT, 4,000 PSI, 6% AIR. C. INTERIOR SLABS ON GRADE NORMAL WEIGHT, 4,000 PSI, 2% AIR. D. INTERIOR SUPPORTED SLABS STRUCTURAL LIGHT WEIGHT, 4,000 PSI, 2% AIR. 2. STEEL REINFORCEMENT: A. DEFORMED BARS: ASTM A -615, Fy =60000 PSI B. WELDED WIRE FABRIC: ASTM A -185, Fy =65000 PSI C. ALL REINFORCING STEEL SHALL BE DETAILED IN IN ACCORDANCE WITH ACI 315 AND SHALL BE SHOP FABRICATED. 3. KEEP THE ARCHITECT INFORMED OF CONCRETE PLACEMENT SCHEDULES SO THAT ARCHITECT CAN INSPECT REINFORCEMENT INSTALLATION PRIOR TO CONCRETE POURS, IF ARCHITECT SO CHOOSES. 4. FURNISH AND RETAIN THE SERVICES OF A QUALIFIED TESTING LABORATORY AND PROVIDE FOUR TEST CYLINDERS FOR EACH 50 CUBIC YARDS OF CONCRETE POURED EACH DAY. 5. TEST ONE CYUNDER AT 7 DAYS, TWO AT 28 DAYS, AND RETAIN ONE AS A SPARE. FURNISH TO THE ARCHITECT A REPORT OF TEST RESULTS, CERTIFIED BY THE TESTING LABORATORY. 6. UNLESS NOTED OTHERWISE, CHAMFER EDGES OF ALL EXPOSED CONCRETE 3/4 7. SAW SLAB CONTROL JOINTS WITH SOFT CUT SAW AS SOON AS CONCRETE WILL SUPPORT FOOT TRAFFIC AND CUTTING MACHINE. 8. ALL STEEL REINFORCING FOR FLOOR SLABS SHALL BE SUPPORTED AT MID DEPTH OF THE SLAB UNLESS NOTED OTHERWISE. 9. SUPPORTS SHALL CONSIST OF CONCRETE BRICKS OR STEEL CHAIRS WITH SAND FEET FOR SLABS -ON -GRADE AND STEEL CHAIRS FOR ELEVATED SLABS. STRUCTURAL STEEL NOTES; 1. ALL STEEL WORK SHALL COMPLY WITH ALL APPLICABLE PROVISIONS OF THE FOLLOWING STANDARDS: AISC SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS, ALLOWABLE STRESS DESIGN AND PLASTIC DESIGN, 1989 AISC SPECIFICATION FOR STRUCTURAL JOINTS USING ASTM A325 OR A490 BOLTS AISC CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES, 1992 SDI SPECIFICATIONS AND COMMENTARIES FOR STEEL DECKS AND CODE OF RECOMMENDED PRACTICE FOR COMPOSITE DECK, FORM DECK, AND ROOF DECK CONSTRUCTION, 1992 AWS D1.1 STRUCTURAL WELDING CODE 2. STRUCTURAL STEEL GENERAL REQUIREMENTS: WIDE FLANGE SHAPES ASTM A572 (FY =50 KSI) ANGLES, CHANNELS, PLATES ASTM A36 (FY =36 KSI) STRUCTURAL TUBES ASTM A500 (FY =46 KSI) 3. ALL BOLTED CONNECTIONS SHALL BE MADE WITH 3/4" DIAMETER A325 BOLTS, UNLESS NOTED OTHERWISE. 4. ALL SHOP AND FIELD WELDS SHALL BE MADE WITH E70 ELECTRODES. 5. PROVIDE AND INSTALL ALL DECK IN A MINIMUM OF 3 -SPAN LENGTHS WHERE POSSIBLE. 6. PROVIDE AND INSTALL 3" X 3" X 1/4" ANGLE DECK SUPPORT AT ALL COLUMNS, OPENINGS, AND OTHER UNSUPPORTED EDGES OF DECK, UNLESS NOTED OTHERWISE. 7. CONNECTIONS NOT SHOWN SHALL BE DESIGNED BY THE STEEL FABRICATOR IN ACCORDANCE WITH THE AISC "MANUAL OF STEEL CONSTRUCTION" AND SHALL BE DESIGNED FOR ONE -HALF THE BEAM'S TOTAL UNIFORM LOAD CAPACITY OR THE END REACTION SHOWN ON THE PLANS, WHICHEVER IS GREATER. WOOD NOTES; 1. ALL WOOD FRAMING, CONNECTIONS, AND ERECTION SHALL CONFORM TO THE NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION. A. 2X STUDS FOR BEARING WALL FRAMING SHALL BE AS SHOWN THE WALL FRAMING SCHEDULE. 8. ALL OTHER WOOD FRAMING SHALL BE SOUTHERN PINE, NO. 2 GRADE OR BETTER. C. EXTERIOR WALL SHEATHING SHALL BE 7/16" APA RATED SHEATHING, 32/16, EXPOSURE 1, WITH 10D NAILS AT 4" 0.C. AT ALL EDGES AND 12" O.C. AT INTERMEDIATE SUPPORTS OR STRUCTURAL GRADE THERMO -PLY (OR EQUAL) WITH NO. 16 GAUGE STAPLES (1" CROWN, 1-1/4" LEGS) AT 3" O.C. AT ALL EDGES AND 6" O.C. AT INTERMEDIATE SUPPORTS D. ROOF DECK SHALL BE 7/16" APA RATED SHEATHING, 32/16, EXPOSURE 1, WITH 10D NAILS AT 6" 0.C. AT EDGES AND 12" O.C. AT INTERMEDIATE SUPPORTS. USE PANEL CUPS BETWEEN PANELS. E. SILL PLATES BEARING ON CONCRETE OR MASONRY SHALL BE TREATED NO. 2 SOUTHERN PINE. F. NAILERS ON STEEL BEAM TOP FLANGES SHALL BE NO. 2 SOUTHERN PINE. 2. ALL MANUFACTURED CONNECTORS SHALL BE SIMPSON STRONG -TIE OR EQUAL. 3. ALL WOOD TRUSSES SHALL BE DESIGNED AND SUPPUED BY THE TRUSS MANUFACTURER. TRUSS DESIGN SHALL BE IN ACCORDANCE WITH THE APPUCABLE PROVISIONS OF THE LATEST EDMON OF "THE NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION" AND "THE DESIGN SPECIFICATION FOR METAL PLATE CONNECTED WOOD TRUSSES" OF THE TRUSS PLATE INSTITUTE. A. ROOF TRUSSES SHALL BE DESIGNED FOR THE FOLLOWING LOADS: TOP CHORD DEAD TOP CHORD LIVE BOTTOM CHORD DEAD BOTTOM CHORD LIVE B. FLOOR TRUSSES SHALL TOP CHORD DEAD TOP CHORD LIVE BOTTOM CHORD DEAD 10 PSF 20 PSF SNOW DRIFTING 10 PSF 10 PSF IN BE DESIGNED FOR 'HE FOLLOWING LOADS: 17 PSF (SEE GENERAL NOTE 4, DESIGN LOADS) 10 PSF C. PRIOR TO FABRICATION, TRUSS MANUFACTURER SHALL PROVIDE SHOP DRAWINGS SHOWING TRUSS ERECTION PLAN, TRUSS CONFIGURATIONS, MEMBER SIZES, TYPE AND GRADE OF LUMBER, ANC BRACING REQUIREMENTS. D. TRUSS MANUFACTURER SHALL VERIFY ALL DIMENSIONS GIVEN ON TRUSS DIAGRAMS PRIOR TO SUBMITTAL OF SHOP DRAWINGS E. SHOP DRAWINGS SHALL BE CERTIFIED BY AN ENGINEER REGISTERED IN THE STATE WHERE THE PROJECT IS LOCATED. 4. PROVIDE A MINIMUM OF 2 CRIPPLE STUDS FOR BEARING AT EACH END OF DOOR AND WINDOW HEADERS. 5. BOLT 2X NAILERS TO STEEL FRAMING WITH 3/8" DIA. A307 BOLTS 0 48" 0.C. STAGGERED, UNLESS NOTED OTHERWISE 6. FOR MULTIPLE MEMBER BEAMS AND HEADERS NAIL PLYS TOGETHER WITH TWO ROWS OF NAILS. USE 10D 0 12" 0.C. FOR CONVENTIONAL LUMBER AND 16D NAILS FOR LVL MEMBERS U.N.O. 7. WOOD FRAMING CONTRACTOR SHALL PROVIDE A COMPLETE INSTALLATION WITH ALL BLOCKING, HEADERS, TRIM SUPPORTS, HAILERS, ETC. TO CONSTRUCT A FINISHED STRUCTURE. NOTES: 1. PROVIDE MINIMUM OF 3" COVER FOR ALL BARS 2. SUPPORT BARS AT INTERVALS OF 3' -0" MAXIMUM. NOTES; 1. PROVIDE MINIMUM OF 3" COVER FOR ALL BARS 2. SUPPORT BARS AT INTERVALS OF 3' -0" MAXIMUM. NOTES; 1 SEE DETAIL X /SXXX AND X /SXXX FOR TYPICAL BAR PLACEMENT. NOTES: 1. SPF SPRUCE- PINE -FIR 2. UNLESS OTHERWISE NOTED, ALL BEARING WALL FRAMING IS TYPE "A" 3. STUDS ARE LISTED IN TABLE FROM LOWEST LOAD CAPACITY (MARK "A TO HIGHEST LOAD CAPACITY (MARK "E STUDS WITH A HIGHER MARK MAY BE SUBSTITUTED FOR THOSE WITH A LOWER MARK. FOR EXAMPLE MARK "0" STUDS MAY BE SUBSTITUTED FOR MARK "C" STUDS. NOTES; 1. PSL PARALLEL STRAND LUMBER. (PARALAM OR EQUAL) 2. LVL LAMINATED VENEER LUMBER (MICROLAM OR EQUAL) 3. UNLESS OTHERWISE NOTED, APPLY HEADERS AS FOLLOWS: H1 H2 H3 H4 H5 OPNGS UP TO 3' -0" OPNGS GREATER THAN OPNGS GREATER THAN OPNGS GREATER THAN OPNGS GREATER THAN NOTES: 1. PROVIDE 8" BEARING EACH END. 2. ALL LINTELS EXPOSED TO WEATHER SHALL BE GALVANIZED. t GRANULAR FILL 3' -0" UP TO 4' -0" 4' -0" UP TO 8' -0" 8' -0" UP TO 10' -0" 10' -0" UP TO 12' -0" EXTERIOR S W/ W.W.F. 0 0 #5 CONT. SEE PLAN_I I POST BEYOND TYP. EXTERIOR SLAB EDGE SCALE: 3/4 =1' -0" GRADE 1' -6" #4 x ol 0 1' -4" O.C. 1" NON- SHRINK GROUT 3/4 "0 ANCHOR BOLT NOTE: COORDINATE LOCATION AND DIMENSIONS OF STEPS WITH MASON 1" NON- SHRINK GROUT 1"0 ANCHOR BOLT W/DBL. NUTS HEAVY WASHER 10 (0' -0 (O' -7 AT DOOR SCALE: 1/2"= 1 -0" 0 2 #5 TYP. STEPPED TRENCH FTG. TS COLUMN 11111 SECTION 1.1 411 1 \I 1/4" LEVELING PLATE 0 N z VAPOR BARRIER GRANULAR FILL RIGID INSU SECTION CONTROL OR CONST. JT. No- BASE PLATE 1/4 LEVELING (SEE COL. SCHEDULE) PLATE TS COLUMN BASE PLATE (SEE COL. SCHEDULE) a0 3 oo 1 SCALE: 3/4 =1' -0" TYP. COL. BASE #5 CONT. SCALE: 3/4 =1' -0" 0 J 0 Z 0 0 -J O tY Z O 0 Z 0 Z O 0 2 "X" 1/2" EXP. JT. TS8 COL. X CONTROL OR CONST. JT, TYP. COL. ISOLA11ON JT. SCALE: 3/4" 1' -0" FLOOR (BEYOND) SLOPED INTERIOR SLAB W/ W.W.F. SCALE: 3/4 =1' -0" 2 -PLY 2X NAILER TYP. NAILER CONN. SEE PLAN PLAN PLAN 3/8"0 BOLTS 0 48" 0.C. EA. SIDE (STAGGER SIDES 24 WALL BEYOND /2" EXP. JOINT EXTERIOR SLAB W/ W.W.F. SLOPE 0 1/8" PER FT. 0 0 2 #5 #4x3' 0 1' -4" 0.C. 1' -6" #4 x 0 1' -4" 0.C. NOTE: STEP TOP OF FTG. DOWN AT GARAGE ENTRANCES. SEE ARCH. DWGS. FOR FLOOR DEPRESSION AND SLOPE DETAILS. TYP. GARAGE ENTRY •=1N rn 1/2" EXP. JOINT 4" SLAB VAPOR BARRIER GRANULAR FILL RIGID INSULATION 1"x 20 GA. ANCHOR STRAPS 0 48" 0.C. 1/2" EXP. JOINT VAPOR BARRIER GRANULAR FILL 5/8" GYP. BD. 2x4 STUDS #5 CONT. TYPICAL TRENCHED FTG. SCALE: 3/4 =1' -0" INTERIOR SLAB TS (SEE PLAN) 0 0 SCALE: 3/4"= 1 -0" 3 #5 CONT. t SEE PLAN SEE PLAN SCALE: 3/4"=1' -0" 5 /8" GYP. BOARD SCALE: 3/4"=1' -0" 6" SCALE: 3/4 =1 -0" 4" FACE BRICK SHEATHING (EXTEND AND ATTACH TO MUD SILL) SIMPSON MAB15 OR EQUAL 0 4' -0" 0.C. (LOCATE IN MASONRY JOINT) POWDER ACTUATED FASTENER (TYP.) (0 EA. MAB15 MUD SILL ANCHOR) GRADE c0 Z_ WALL BEYOND 1 /2" EXP. JQINT EXTERIOR SLAB SLOPE_ 0 1/8" PER F7. TYP. ENTRY SEC11ON 1' -6" 6" #4x3' -0" c0 #4 x 1,-6 "Iw #5 CONT. TYP. INTERIOR SPREAD FTG. 2x STUD 5/8" GYP. BOARD SOLE PLATE 1 W.W.F. TYP. THICKENED SLAB 6x6 -W 1.4xW 1.4 WWF AIIIIMMECSIZZEW O_ 1/2" EXP. JOINT FORMED CONSTRUCTION JOINT VAPOR BARRIER 4" COMPACTED GRANULAR FILL TYP. CONSTRUC11ON JOINT 6x6- W1.4xW1.4 WWF SCALE: 3/4 =1' -0" 1" DEEP SAWED CONTROL JOINT W/ LIQUID SEALER FILL 4" COMPACTED GRANULAR FILL TYP. CONTROL JOINT Z 0 rn m 0 N Pf) m 0 Emp r .)w otb cG ar c4 Val 11 4 I C s b e° .T .f.3 SCALE AS NOTED SHEET S401 4" COMPACTED GRANULAR FILL 1' -4" 0.C. 0 1' -4" 0.C. 1 6 MIL VAPOR BARRIER VAPOR BARRIER