Loading...
HomeMy WebLinkAboutCN AdminRenovation Stamp Set 1-14-11.pdf1. Portions of the building shall be occupied during construction. Contractors shall comply with the following life safety issues. Failure to list all life safety issues does not relieve the contractors from complying with federal, state and local codes, the contractural agreement between the contractor and the owner,and the other governing bodies which have jursidiction on this project. The following are interim life safety code issues which are specific to this project and must be addressed. A. Insure all exits provide free and unobstructed egress. B. Smoking shall be prohibited in all areas of the building. Campus is smoke free environment. C. Develop and enforce storage, housekeeping and debris removal procedures that reduce the flammable and combustible fire load to the lowest level necessary for daily operations. D. Secure all tools and construction materials during breaks and non-construction hours. E. IOSHA requires material safety data sheets (MSDS) for all materials being used or stored on this project be made available to all workers on this jobsite. 2. The contractors shall be responsible for informing the owner in writing on a bi-weekly basis, the construction schedule for the approaching two weeks construction period. Any storage materials access or egress problems, traffic flow or normal owner operations which are to be affected must be protected and/or agreed upon by owner. All costs shall be incurred by the general contractor. 3. Any services which must be temporarily shut off must be coordinated with the owner. 4. All construction areas, removal traffic pattern areas and associated work areas shall be kept clean of debris by the contractors daily. 5. Fire rated wall and ceiling penetrations must comply with E-814. 6. The general contractor shall provide all necessary fire treated wood blocking for all trades. Continuous blocking required for all wall hung shelving, casework, grab bars and handrails. Brace walls with wall hung items to deck as by printed stud mfg. recommendations. 7. Dimensions are to face of stud or masonry, unless otherwise noted. 8. Existing surfaces shall be prepared to accept new finishes, per finish material manufacturer recommendations. This preperation of substrate shall be the responsibility of the particular finish contractor. If no preperation work is done to surfaces, the contractor accepts the conditions as they are, and is responsible for the performance of the material. 9. "Construction Limits" generally illustrate areas of new construction. Other work may be required for demolition or replacement of the other systems including the MEP. 10. Contractor to provide ten-day notice with owner-supplied forms for all system shut-downs to facilities. Minimal exceptions will be made in cases of emergency or schedule conflicts on an owner-determined basis. 1. General Contractor is responsibleto provide all design, material, and labor under seperate vender contract as required for a complete installation in compliance with all State, Local, and Health Department Building Codes. 2. Architectural Documents indicating Mechanical, Electrical, and Plumbing work are schematic concepts. Documents are for reference only. 3. Architectural Documents provide suggested fixture locations and fixture types. All sizing, circuiting, and switching to be vendor engineered by contractor. 4. HVAC Systems to be vendor engineered under seperate contract. 5. Electrical Power and Data Systems to be vendor engineered under seperate contract. 6. Lighting Systems to be vendor engineered under seperate contract. Architect: MSKTD & Associates, Inc. General Contractor: Messer Construction Mechanical & Plumbing Vendor: Leach & Russell Electrical Vendor: ERMCO Electric COMMISSION NUMBER DATE SHEET NUMBER 1715 MAGNAVOX WAY FORT WAYNE, IN 46804 voice 260.432.9337 fax 260.436.2402 930 NORTH MERIDIAN INDIANAPOLIS, IN 46204 voice 317.917.1190 fax 317.822.6236 http://www.msktd.com ARCHITECTURE ENGINEERING INTERIOR DESIGN CERTIFICATION 11700 N. Meridian Street, Carmel, IN 46032 MEDICAL OFFICE BUILDING CLARIAN NORTH MEDICAL CENTER (HOSPITAL) APPLICABLE CODES Indiana Fire Prevention and Building Safety Code IAC 675 12 Administrative Rules 13 Building Code: 2006 International Building Code with Indiana Amendments 16 Plumbing Code: 1997 Uniform Plumbing Code with Indiana Amendments 17 Electrical Code: 2008 Electrical Code with Indiana Amendments 18 Mechanical Code: 2006 International Mechanical Code with Indiana Amendments 19 The Indiana Energy Conservation Code, 2010 Edition consisting of ASHRAE 90.1, 2007 Edition with Indiana Amendments) 22 Fire Prevention Code: 2006 International Fire Code with Indiana Amendments PROPOSED USE Ambulatory Surgery Center CLASSIFICATION B - Business IBC sec. 308.3 CONSTRUCTION TYPE Type 1-A IBC Table 601 AUTOMATIC SPRINKLERS Fully-Sprinkled, Class 1 FLOOR AREA Medical Office Suite 4,130 sq. ft. HEIGHT (7) Seven Stories 106' - 8" INDIANA ADMINISTRATIVE CODE: 2010 Edition Indiana Fire Prevention and Building Safety Code IAC 675 Rule 6. Design Release 675 IAC 12-6-4 Exemptions from design release requirement Sec. 4 (b) (3) Electrical work as follow: (A) Replacement in the same location of electrical equipment or devices of a similar type and rating, including an increase in current capacity in nonhazardous areas where there is no change in voltage or phases. (D) Installation of branch circuits not exceeding the capacity of the electrical distribution system within the existing building. (4) Mechanical work as follow: (B) Replacement of mechanical appliances and equipment with a similar type and rating in the same location. (5) Miscellaneous work as follow: (D) Installation of one (1) or more nonload-bearing partitionsnot to exceed a total of one hundred (100) lineal feet in length provided it is not part of a corridor or a partition that is required to be of fire-resistive construction. COMMISSION NUMBER DATE SHEET NUMBER 1715 MAGNAVOX WAY FORT WAYNE, IN 46804 voice 260.432.9337 fax 260.436.2402 930 NORTH MERIDIAN INDIANAPOLIS, IN 46204 voice 317.917.1190 fax 317.822.6236 http://www.msktd.com ARCHITECTURE ENGINEERING INTERIOR DESIGN CERTIFICATION 11700 N. Meridian Street, Carmel, IN 46032 1/14/2011 12:42:52 PM A0.1 Administration Suite 5563 01-14-11 Clarian North Medical Center Code Review First Floor Key Plan Construction Design Release 172 SF OFFICE 171 SF K154 OFFICE K153 220 SF MEETING K151 ADMIN ASSISTANT K153A K151A 1 2 3 4 2' - 1" 5 5 HALLWAY K1C04 ADMIN ASSISTANT 1 2 3 3 3 4 4 5 6 7 8 8 8 9 9 9 9 10 10 10 8 COMMISSION NUMBER DATE SHEET NUMBER 1715 MAGNAVOX WAY FORT WAYNE, IN 46804 voice 260.432.9337 fax 260.436.2402 930 NORTH MERIDIAN INDIANAPOLIS, IN 46204 voice 317.917.1190 fax 317.822.6236 http://www.msktd.com ARCHITECTURE ENGINEERING INTERIOR DESIGN CERTIFICATION 11700 N. Meridian Street, Carmel, IN 46032 1/14/2011 12:42:52 PM A2.1 Administration Suite 5563 01-14-11 Clarian North Medical Center 1/8" = 1'-0" First Floor Plan Specific Plan Notes 1 INFILL WALL, FLOOR, AND CEILING OPENING. INFILL TO BE FLUSH AND LEVEL WITH EXISTING 1 1 2 3 FLOOR CARPET CPT-8 ATLAS. STYLE: SWIRLS (BROADLOOM). COLOR: #SW21 TROPICAL SAND. BASE RUBBER RB-1 JOHNSONITE. STYLE: 4" HIGH COVED. COLOR: #29 MOON ROCK. WALLS PAINT P-1 SHERWIN WILLIAMS. #SW6378. COLOR: CRISP LINEN. P-2 SHERWIN WILLIAMS. #SW6113. COLOR: INTERACTIVE CREAM. VINYL WALL COVERING VWC-1 MDC WALLCOVERING. STYLE: VYCON OASIS. COLOR: #Y449180A CLASSIC WHITE. VWC-2 MDC WALLCOVERING. STYLE: VYCON OASIS. COLOR: #Y449150A GRASSCLOTH. VWC-5 SYMPHONY. STYLE: SONNET. COLOR: #AZ504725SN PORT. CEILING ACOUSTICAL CEILING ACT-1 ARMSTRONG. STYLE: DUNE , FINE TEXTURE 24" x 24". COLOR: #1772 WHITE. A G B 6" 6" 3' - 6" 6" REUSE EXISTING DOOR FROM PROJECT. OWNER PROVIDED. (SCOPE PROCESSING) OWNER PROVIDED. 1 COMMISSION NUMBER DATE SHEET NUMBER 1715 MAGNAVOX WAY FORT WAYNE, IN 46804 voice 260.432.9337 fax 260.436.2402 930 NORTH MERIDIAN INDIANAPOLIS, IN 46204 voice 317.917.1190 fax 317.822.6236 http://www.msktd.com ARCHITECTURE ENGINEERING INTERIOR DESIGN CERTIFICATION 11700 N. Meridian Street, Carmel, IN 46032 1/14/2011 12:42:52 PM A9.1 Administration Suite 5563 01-14-11 Clarian North Medical Center 1/8" = 1'-0" Reflected Ceiling Plan ROOM FINISH SCHEDULE Room No. Name Floor Base Walls Ceiling N E S W Type Remarks K1C04 HALLWAY CPT-8 RB-1 VWC-1 VWC-1 VWC-1 VWC-1 ACT-1 --- 172 SF OFFICE 171 SF K154 OFFICE K153 220 SF MEETING K151 ADMIN ASSISTANT 9 9 9 7 1LNRD6 7,9 13 13 13 1LNRD6 13 (11 - NOT USED) 2 6 1LNRD6 2, 4, 6, 8 ADMIN ASSISTANT 9 9 13 7 2 9 13 11 11 13 11 SSS T T SSS T SS T TU-14038 TU-14108 TU-14108 SSS T SSS T T TU-14108 TU-14108 COMMISSION NUMBER DATE SHEET NUMBER 1715 MAGNAVOX WAY FORT WAYNE, IN 46804 voice 260.432.9337 fax 260.436.2402 930 NORTH MERIDIAN INDIANAPOLIS, IN 46204 voice 317.917.1190 fax 317.822.6236 http://www.msktd.com ARCHITECTURE ENGINEERING INTERIOR DESIGN CERTIFICATION 11700 N. Meridian Street, Carmel, IN 46032 1/14/2011 12:42:53 PM MEP 2.1 Administration Suite 5563 01-14-11 Clarian North Medical Center SCHEMATIC NOTES: GENERAL NOTES - PANEL 1LNRD6, CIRCUIT 11 IS NOT USED. REMOVE AND/OR RELOCATE (5) QUAD POWER OUTLETS AND (1) DUPLEX POWER OUTLET. REMOVE AND/OR RELOCATE (3) QUAD TELECOM PORTS. SCHEMATIC NOTES: OFFICE #K153 - RELOCATE (1) QUAD POWER OUTLET AND RECONNECT TO PANEL 1LNRD6, CIRCUIT 9. ADD (1) QUAD TELECOM PORT. MEETING #K151 - RELOCATE (2) QUAD POWER OUTLETS AND RECONNECT TO PANEL 1LNRD6, CIRCUIT 13. CORRIDOR #K1C04 - RELOCATE (1)DUPLEX POWER OUTLET AND RECONNECT TO PANEL 1LNRD6, CIRCUIT 2. Power/Systems Plan Power/Systems Demo Plan SCHEMATIC NOTES: GENERAL NOTES - REMOVE (1) THERMOSTAT AND (1) 'VAV' BOX. RELOCATE (3) THERMOSTATS. REWORK/LAY-OUT EXISTING SUPPLY DUCTWORK. REUSE EXISTING GRILLES AND DIFFUSERS. RELOCATE LIGHT SWITCHES TO NEAR DOORS. REWORK/LAY-OUT EXISTING LIGHTS. HVAC & Lighting Plan HVAC & Lighting Demo Plan Schematic Schematic Schematic Schematic REFERENCE ONLY (MEP DESIGN-BUILD) K151 MEETING CPT-8 RB-1 VWC-2 VWC-2 VWC-2 VWC-2 ACT-1 --- K153 OFFICE CPT-8 RB-1 VWC-2 VWC-2 VWC-2 VWC-2 ACT-1 --- Material Legend DOOR AND OPENING SCHEDULE Opening No. Door Frame Details Door Glass Hdw Size Mat. Ele. Mat. Ele. Head Jamb . Set Remarks First Floor Slab K151A 3'-0" x 7'-0" x 1 3/4" WD 2 HM 1 --- --- B 1 OF / CI K153A 3'-0" x 7'-0" x 1 3/4" WD 1 HM 1 --- --- --- 2 OF / CI GENERAL NOTES: 1. DOORS, FRAMES, AND ALL HARDWARE ARE FURNISHED BY OWNER AND INSTALLED BY CONTRACTOR. 2. GLAZING TYPE 'B' = 1/4" CLEAR, TEMPERED. 3. HARDWARE SET #1 = PASSAGE LOCKSET (OWNER FURNISHED). 4. HARDWARE SET #2 = OFFICE LOCKSET (REUSE EXISTING). Specific Reflected Ceiling Plan Notes 1 NEW CEILING GRID AND TILE AT 8'-10" A.F.F. 2 PATCH AND REPAIR EXISTING BULKHEAD COVE. PAINT (P-1). 3 REMOVE EXISTING PORTION OF LAY-IN CEILING FOR INSTALLATIONS. REINSTALL TILE AND GRID. PROTECT. ADJACENT CONSTRUCTION. PREPARE TO RECEIVE NEW FINISHES. 2 REPAIR AND PATCH VINYL WALL COVERING TO ENSURE CONTINUOUS VERTICAL JOINTS FROM FLOOR TO CEILING. 3 ALIGN NEW WALL TO BE FLUSH WITH EXISTING CORNER. 4 WALL TO RECEIVE VINYL WALL COVERING (VWC-5). 5 FULL-HEIGHT WINDOW (8'-2" AFF) TO RECEIVE DUAL-ROLLER FLEXSHADE WITH HOUSING. FABRICS TO BE (MS1) AND (MS2). 1/8" = 1'-0" Demo Floor Plan Specific Demolition Notes 1 (INFECTIOUS CONTROL) CONSTRUCTION AND DUST SEPARATION WALL. 6" METAL STUD w/ 5/8" VINYLE-FACES GYPSUM BOARD AND SOUND ATTENUATION BLANKET. EXTEND TO CEILING. TAPE SEAMS. REFER TO CLARIAN'S MANDATORY CONTRACTOR'S ORIENTATION REQUIREMENTS. MAINTAIN A MINIMUM OF 5'-0" AT EXISTING CORRIDORS AND OWNER OCCUPIED SPACES FOR EGRESS. CONTRACTOR IS RESPONSIBLE FOR SUPPLYING AND DETERMINING WALL LOCATIONS AND NUMBER AND SIZE OF CONSTRUCTION DOORS WITHIN SEPARATION WALL. REPAIR FLOOR AND WALLS AS NEEDED AFTER REMOVAL OF WALLS. 2 REMOVE PORTION OF WALL FOR NEW DOOR AND FRAME. 3 REMOVE WALL ASSEMBLY. 4 REMOVE DOOR AND FRAME. PROVIDE OWNER WITH DOOR LEAF AND ALL ASSOCIATED HARDWARE. 5 REMOVE DOOR AND FRAME. REUSE DOOR LEAF AND ALL ASSOCIATED HARDWARE FOR NEW DOOR LOCATION #K153A. 6 REMOVE BULKHEAD COVE ASSEMBLY AND ELECTRICAL LIGHTING AS NEEDED. PREP WALL AREA FOR NEW GYPSUM BOARD AND VINYL WALL COVERING. 7 REMOVE 'RED' VINYL WALL COVERING ON WEST FACE. PREP AREA FOR NEW VINYL WALL COVERING. 8 REMOVE ALL FLOORING AND LAY-IN CEILING. 9 SALVAGE AND REUSE ALL EXISTING LIGHTING WITHIN PROJECT AREA. 10 SALVAGE AND REUSE ALL EXISTING HVAC GRILLES AND DIFFUSERS WITHIN PROJECT AREA. 1/14/2011 12:42:53 PM T0.1 Administration Suite 5563 01-14-11 Clarian North Medical Center General Construction Notes Clarian North Medical Center 11700 North Meridian Street, Carmel, IN 46032 Administration Suite Renovation Design Build Notes