Loading...
HomeMy WebLinkAboutA2.2 PATIO PLAN.pdfFIELD VERIFICATION SUBMISSIONS: CONTRACTOR SHALL VERIFY ALL FIELD DIMENSIONS AND CONDITIONS WITH THE SITE AND REPORT ANY DISCREPANCIES, ERRORS OR OMITTANCES TO TRAPP ARCHITECTURE PRIOR TO CONSTRUCTION OR FABRICATION. THE INFORMATION CONTAINED IN THESE DRAWINGS IS BASED ON EXISTING DRAWINGS AND MAY NOT BE CURRENT TO THE BUILT CONDITIONS OF THE SITE. COPYRIGHT TRAPP ARCHITECTURE SHALL RETAIN ALL STATUARY, COMMON LAW AND OTHER RESERVED RIGHTS. THESE DRAWINGS AND RELATED DOCUMENTS SHALL NOT BE DUPLICATED, DISCLOSED OR OTHERWISE WITHOUT WRITTEN CONSENT OF TRAPP ARCHITECTURE. PERMIT: APRIL 15, 2011 SCALE: PATIO PLAN 1 1/4" = 1'-0" PLAN NORTH SAND, STAIN (ST-1) AND REFINISH WOOD AT EXTERIOR PATIO WALLS. GRIND INTO PATIO CONCRETE TO EXPOSE AGGREGATE, STAIN AND SEAL, (ST-3). GC TO PROVIDE ALT/ADD NUMBER FOR ROLL DOWN PATIO SHADES AT PATIO WINDOWS THROUGHOUT. TRAPP ASSOCIATES TO REVIEW SPEC. AND APPROVE PRIOR TO ORDERING. GLUE OAK TREAD W/ BULLNOSE TO TOP OF EXISTING CONCRETE CURB, STAIN: ST-2. GC PROVIDE ALT./ ADD NUMBER TO REPLACE SMOKED GLAZING WITH CLEAR, TEMP. INSULATED GLASS. NEW WEATHER STRIPPING AROUND ALL PATIO WINDOWS. NEW 8 HEAD TAP TO COORDINATE WITH OPERATIONS EQUIPMENT SUPPLIER. ADD MATCHING MAHOGANY PANELING FROM BELOW STONE SILL TO 6" WD. BASE BD. KEYED NOTES: 1 2 3 4 5 1. PROVIDE 5/8" WATER RESISTANT GYPSUM BOARD BEHIND ALL CERAMIC TILE AT WALLS IN WAIT STATIONS, KITCHEN, BAR, AND RESTROOM AREAS, WHERE APPLICABLE. PROVIDE ALT. PRICE FOR EXTERIOR GYP. BOARD AT SAME AREAS. 2. USE 5/8" GYPSUM BOARD AT ALL WALLS, PARTITIONS AND CEILINGS WHERE GYPSUM BOARD INDICATED, UNLESS OTHERWISE NOTED OR CONDITIONS REQUIRE ALTERNATIVE. 3. COORDINATE EXTENT AND LOCATION OF WALL BLOCKING, REINFORCING AND OPENINGS WITH FOOD SERVICE EQUIPMENT SUPPLIER, PREFAB ENCLOSURE CONTRACTOR AND MILLWORK CONTRACTOR IF SCOPE OF WORK REQUIRES EQUIPMENT MODIFICATION. 4. PROVIDE AND VERIFY EXISTING PLYWOOD REINFORCING AND WOOD BLOCKING BEHIND ALL WALL MOUNTED SINKS AND WALL MOUNTED TOILET ROOM ACCESSORIES, GRAB BARS, AND WOOD TRIM. 5. PROVIDE 2X10 BLOCKING AT ALL BOOTH TABLES FOR ANGLE BRACKET CANTILEVERS AND POST BASE. COORDINATE FINAL LOCATIONS WITH RESTAURANT DESIGNER (AS APPLICABLE). 6. VERIFY FINAL EQUIPMENT LOCATIONS AND DIMENSIONS WITH OWNER'S REP. AND/OR EQUIPMENT SUPPLIER PRIOR TO FABRICATING OR INSTALLING ANY MILLWORK AROUND BAR/KITCHEN EQUIPMENT (AS APPLICABLE). 7. REFER TO FINISH SCHEDULE, SHEET A7.1 FOR INDICATION OF TYPES, COLORS, ETC., OF ALL CERAMIC AND QUARRY TILE. REFER TO FINISH SCHEDULE AND ROOM ELEVATIONS FOR EXTENT OF WORK. 8. REFER TO SHEET A7.2 FOR FURNITURE LAYOUT AND SEATING DATA. 9. ALL BOOTH DIMENSIONS ARE TO FACE OF PANELING. REFER TO DETAILS #2 AND #5 / SHEET A8.2. GC TO VERIFY WITH TRAPP ASSOCIATES EXISTING BOOTHBASE DIMENSIONS PRIOR TO WORK. 10. CONTRACTOR TO REFER TO BOOTH DETAILS #2 AND #5 ON SHEET A8.2 FOR SPECIFIC DIMENSIONS ON BOOTH BASE CONSTRUCTION. 11. FIRE EXTINGUISHERS SHALL REMAIN 'AS IS' SO THAT THERE IS NO MORE THAN A 75 FOOT TRAVEL DISTANCE TO AN EXTINGUISHER FROM ANY PORTION OF THE BUILDING. THE EXTINGUISHERS SHALL HAVE A 2A:10BC RATING. IN ADDITION TO THESE EXTINGUISHERS, 40BC EXTINGUISHERS SHALL BE PROVIDED WITHIN 25 FEET OF ALL KITCHEN EQUIPMENT PROTECTED BY THE HOOD AND DUCT PROTECTION SYSTEM. 12. EMERGENCY PULLS, STROBES, SIRENS, THERMOSTAT, EMERGENCY LIGHTING SHALL REMAIN 'AS-IS'. IF RELOCATION IS REQUIRED HOWEVER, NEW LOCATIONS SHALL COMPLY WITH CODE BUT WITH CONSIDERATION FOR ART WALLS IF REQUIRED BY NEW FLOOR PLAN LAYOUT. COORDINATE WITH RESTAURANT DESIGNER ON FINAL LOCATIONS PRIOR TO WORK. 13. BOTTOM OF T.V.S AT 9'-0" A.F.F. TYPICAL, UNLESS OTHERWISE NOTED. 14. MENU BOX LOCATIONS FIELD LOCATED BY DESIGNER, MOUNTED AT 24" A.F.F. TO BOTTOM OF BOX. 15. TRAY BOX LOCATIONS FIELD LOCATED BY DESIGNER, MOUNTED AT 16" A.F.F. TO BOTTOM OF BOX AT COCKTAIL STATIONS. 16. NOTE: GC RESPONSIBLE FOR ALL DAMAGE TO TABLES, BOOTHS, LIGHT FIXTURES, SHADES, REPAIR OR REPLACE BY 'TURNOVER' DATE, COSTS TO BE DEDUCTED FROM FINAL PAYMENT. 17. DEBRIS CONTINUOUSLY TO BE REMOVED BY GC. 18. ALL WINDOW AND DOOR DIMENSIONS ARE SHOWN AS NOMINAL SIZING. REFER TO MANUFACTURER'S CLEAR FRAMING REQUIREMENTS PRIOR TO CONSTRUCTION. 19. TOP OF WALL (T.O.W.) HEIGHTS SHOWN ARE FROM FINISHED FLOOR TO TOP OF WALL FINISH. 20. G.C. TO REFER TO AS BUILT MEP SHEETS FOR LOCATIONS AND INFORMATION REGARDING ALL UTILITIES. 21. CONTRACTOR TO REFER TO SHEET A7.1 FLOOR FINISHES FOR ADDITIONAL FLOOR PLAN NOTES. 22. FOR INTERIOR FINISH MATERIALS AND COLORS REFER TO FINISH AND COLOR SCHEDULES, SHEET A7.1. THE FLAME SPREAD RATING OF INTERIOR FINISHES SHALL NOT EXCEED "75". FINISH MATERIAL SHALL BE APPROVED BY THE STATE FIRE MARSHAL OR BUILDING OFFICIAL WITH JURISDICTION PRIOR TO INSTALLATION. 23. FOR ALL WALL-MOUNTED AND SEMI- RECESSED MOUNTED EQUIPMENT ACCESSORIES, CABINETS, HANDRAILS, MECHANICAL/ELECTRICAL EQUIPMENT, ETC., PROVIDE AND INSTALL SOLID BLOCKING IN WALL BEHIND IF NOT EXISTING. 24. GC TO INSTALL FIRE BLOCKING AS REQUIRED PER CODE. BOOTH PLATFORMS TO NOT EXCEED 100 S.F. OF OPEN FRAMING WITHOUT BLOCKING. 25. UNISTRUT-CLIPS REQUIRED AT ALL INDIRECT DRAINS/PIPING/FLOOR SINKS, ETC., WHERE APPLICABLE. 26. FOR FURNITURE LAYOUT, FLOOR FINISHES, SEATING, ETC. REFER TO SHEET A7.2. 27. ALL NEW EXPOSED WOOD AT MILLWORK AND TRIM TO MATCH TYPICAL EXISTING TYPE, FINISH, DIMENSIONS AND DETAILING. 28. NO CLEAR SILICONE TO BE USED AT FRONT OF HOUSE. IF REQUIRED, USE COLORED CAULK TO MATCH SURROUNDING MATERIALS. 29. GC TO COORDINATE CONSTRUCTION STAGING WITH GENERAL MANAGER AND MALL REPRESENTATIVE. FLOOR PLAN NOTES 6 7 PATIO PLAN & DETAILS 6 6 6 6 2 2 2 2 5 1 1 1 3 3 3 3 3 3 1 4 8 5 5 5 5 5 5 5 5 8 8 2'-6" 44'-0" 4'-0" 13'-0" 2 A2.2 SCALE: RAILING ELEVATION 2 3/4" = 1'-0" SCALE: RAILING DETAIL 4 3/4" = 1'-0" 3'-6" 6'-0" 6 EQ. SPACES IN 36'-0" 4" SQ. NEWELLS, W/ 5" SQUARE CAP, PAINT SATIN OIL - PT-7 3 4" x 2" TUBE, PAINT SATIN OIL - PT-8 6" SQ. PLATE, WELDED TO NEWEL, BOLT DOWN TO SIDEWALK, PAINT SATIN OIL - PT-7 4'-0" 5'-0" SCALE: RAILING ELEVATION 3 3/4" = 1'-0" 3 A2.2 3'-6" 4'-0" 4" SQ. NEWELLS, W/ 5" SQUARE CAP, PAINT SATIN OIL - PT-7 3 4" x 2" TUBE, PAINT SATIN OIL - PT-8 EXTERIOR BOLT ON POT RING 10" DIA. PAINT SATIN OIL - PT-7