Loading...
HomeMy WebLinkAboutA7.3 RCP.pdfFIELD VERIFICATION SUBMISSIONS: CONTRACTOR SHALL VERIFY ALL FIELD DIMENSIONS AND CONDITIONS WITH THE SITE AND REPORT ANY DISCREPANCIES, ERRORS OR OMITTANCES TO TRAPP ARCHITECTURE PRIOR TO CONSTRUCTION OR FABRICATION. THE INFORMATION CONTAINED IN THESE DRAWINGS IS BASED ON EXISTING DRAWINGS AND MAY NOT BE CURRENT TO THE BUILT CONDITIONS OF THE SITE. COPYRIGHT TRAPP ARCHITECTURE SHALL RETAIN ALL STATUARY, COMMON LAW AND OTHER RESERVED RIGHTS. THESE DRAWINGS AND RELATED DOCUMENTS SHALL NOT BE DUPLICATED, DISCLOSED OR OTHERWISE WITHOUT WRITTEN CONSENT OF TRAPP ARCHITECTURE. PERMIT: APRIL 15, 2011 REFLECTED CEILING PLAN SCALE: REFLECTED CEILING PLAN 1 1/4" = 1'-0" KEYED NOTES: CEILING FINISHES: C-2 C-1 C-3 C-4 C-5 C-6 CEILING TO REMAIN AS IS, SEE SHEET A7.1 FOR FINISH NEW 2X2 'ILLUSION' ACOUSTIC TILE IN EXISTING GRID, SEE SHEET A7.1 FOR FINISH GYP. BD. AT NOTED HEIGHT, SEE SHEET A7.1 FOR FINISH FLOATING WOOD SOFFIT SEE DETAIL: 2/A7.3, 3 & 4/A7.4 EXISTING T-GRID CEILING & & TILES TO REMAIN 'AS IS' EXPOSED CEILING TO REMAIN, SEE SHEET SHEET A7.1 FOR FINISH 1 2 3 4 5 7 6 FIXTURE LEGEND: TABLE LIGHT PENDANT LIGHT CLOCK OUTLET W/ TABLE MOUNTED FIXT RECESSED CAN CEILING FAN WALL SCONCE 1x4 FLUORESCENT 2X4 FLUORESCENT SGL SURFACE SPOT DBL SURFACE SPOT RECESSED AND SCREWED INTO GRID W/ ACRYLIC DIFFUSER, REFER TO ELECT. DRAWINGS FOR FINAL LOCATION W/ ACRYLIC DIFFUSER, MOUNT TO CEILING NOTE: REFER TO LUMINAIRE SCHEDULE & NOTES ON SHEET A7.4, SPECS AND ELECTRICAL DWGS FOR MOUNTING HEIGHTS, LAMPING, AND ADDTL. INFO. TV - 9'-6" AFF TO B.O., UNO REMOVE AND SALVAGE EXISTING LIGHT FIXTURE, REPAIR SURFACES IF REQD., REUSE CIRCUIT FOR NEW ADJACENT FIXTURE AS APPLICABLE DEMO ALL EXISTING 'UMBRELLA' FIXTURES. REUSE CIRCUITS FOR NEW LIGHTING LAYOUT. HOOD LIGHTING NOTE: USE 2700K OR LOWER CFL'S CENTER FIXTURE ON CEILING IN SPACE REPAIR CEILING AS REQ'D TO MATCH ADJ. SURFACE FOLLOWING REMOVAL OF CHANNEL AND FULL HT. GLAZING. RELOCATE POWER & DATA AS REQUIRED TO NEW SIDE HOSTESS STAND. RELOCATE LIGHT TRACKS TO B.O. NEW WOOD SOFFIT IN SAME LOCATION. RELOCATED LIGHT TRACK, REUSE EXISTING CIRCUITS. OPEN REPAIR CEILING AS REQUIRED TO MATCH ADJ., FOLLOWING DEMO OF PARTITION RELOCATE DIFFUSERS TO NEW CEILING, FINISH TRIM TO MATCH, FIELD ADJUST AIR FLOW BALANCE CENTER FIXTURES ON TABLE TOP, TYPICAL FOR ALL 'A_' FIXTURES CENTER BOOTH FIXTURES ON TABLE TOP, TYPICAL FOR ALL 'B' FIXTURES, WHERE APPLICABLE. NEW GYP BD CEILING, FINISH AND HEIGHT TO MATCH ADJACENT HOST CEILING @ 9'-0" RELOCATE EXISTING EXITING FIXTURES TO NEW NOTED LOCATION, MATCH EXIST. HEIGHT, IF REQUIRED. TOP OF TV AT 8'-9" AFF EXISTING EXIT LIGHTING TO REMAIN 'AS-IS', TYPICAL. REMOVE EXISTING FIXTURE, INSTALL NEW FIXTURE @ LOCATION, SEE LUMINAIRE SCHEDULE FOR TYPE. EXISTING DIFFUSERS TO REMAIN 'AS-IS', TYPICAL FOR ALL HVAC, GC TO CONTACT ARCHITECT PRIOR TO CONSTRUCTION IF HEIGHT CONFLICT ARISES W/ NEW CONSTRUCTION, SHOP PAINT TO MATCH ADJACENT FINISH IF ALTERED. T-GRID CEILING & TILES CONTINUE OVER DROP SOFFIT. PLUG MOLD POWER INSIDE BAR DIE, CONTINUOUS BELOW TOP, SEE DETAIL 1/A8.2 BOOTH LIGHTING CENTERED ON TOPS, AT HEIGHT PER LUMINAIRE SCHEDULE, TYPICAL. DEMO FALSE (LOWER) T-GRID CEILING. UPPER T-GRID CEILING WITH ACOUSTIC TILES TO REMAIN. TOP OF TV AT 10'-0" AFF REMOVE ACOUSTICAL TILES AND PAINT GRID FLAT BLACK TO MATCH TILES THROUGHOUT UPPER GRID. RELOCATE EXISTING TRACK TO B.O. WOOD SOFFIT, CENTERED AND ABOVE LOOSE TABLES. RAISE TV'S 12" CONTINUE EXISTING HEATER NORTH TO FULL HEIGHT PARTITION NEW HEADER, NORTH OF FULL HEIGHT PARTITION, MATCH DEMO'D HEIGHT. NO WORK BACK OF HOUSE 8 9 10 11 12 3 A7.4 3 A7.4 4 A7.4 C-4 10'-0" 18'-0" 16'-0" C-4 10'-0" 21'-0" 14'-0" 13'-0" 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 3 2 2 2 2 2 2 2 2 2 SCALE: WOOD CLOUD DETAIL 2 3" = 1'-0" 1 4" x 6" CVG FIR 3 4" GAP PAINT BLACK CLOUD'S 3 4" x 12" BORDER 3 4" BLACK SPACER SET IN 3 4" WOOD CLOUD UNIT #1 WOOD CLOUD UNIT #2 2 A7.3 29 C-1 6 16 16 11 11 C-3 14 14 25 25 21 23 C-5 9'-0" 24 28 29 10 C-1 9'-0" C-1 C-1 C-1 12 19 8 8 C-6 8 26 C-1 26 26 12 19