HomeMy WebLinkAboutA7.3 RCP.pdfFIELD VERIFICATION SUBMISSIONS:
CONTRACTOR SHALL VERIFY ALL FIELD DIMENSIONS AND
CONDITIONS WITH THE SITE AND REPORT ANY DISCREPANCIES,
ERRORS OR OMITTANCES TO TRAPP ARCHITECTURE PRIOR TO
CONSTRUCTION OR FABRICATION. THE INFORMATION CONTAINED
IN THESE DRAWINGS IS BASED ON EXISTING DRAWINGS AND MAY
NOT BE CURRENT TO THE BUILT CONDITIONS OF THE SITE.
COPYRIGHT
TRAPP ARCHITECTURE SHALL RETAIN ALL STATUARY, COMMON
LAW AND OTHER RESERVED RIGHTS. THESE DRAWINGS AND
RELATED DOCUMENTS SHALL NOT BE DUPLICATED, DISCLOSED
OR OTHERWISE WITHOUT WRITTEN CONSENT OF TRAPP
ARCHITECTURE.
PERMIT: APRIL 15, 2011
REFLECTED CEILING PLAN
SCALE:
REFLECTED CEILING PLAN
1 1/4" = 1'-0"
KEYED NOTES: CEILING FINISHES:
C-2
C-1
C-3
C-4
C-5
C-6
CEILING TO REMAIN AS IS,
SEE SHEET A7.1 FOR FINISH
NEW 2X2 'ILLUSION' ACOUSTIC
TILE IN EXISTING GRID, SEE
SHEET A7.1 FOR FINISH
GYP. BD. AT NOTED HEIGHT,
SEE SHEET A7.1 FOR FINISH
FLOATING WOOD SOFFIT SEE DETAIL:
2/A7.3, 3 & 4/A7.4
EXISTING T-GRID CEILING &
& TILES TO REMAIN 'AS IS'
EXPOSED CEILING TO REMAIN, SEE
SHEET SHEET A7.1 FOR FINISH
1
2
3
4
5
7
6
FIXTURE LEGEND:
TABLE LIGHT
PENDANT LIGHT
CLOCK OUTLET W/
TABLE MOUNTED FIXT
RECESSED CAN
CEILING FAN
WALL SCONCE
1x4 FLUORESCENT
2X4 FLUORESCENT
SGL SURFACE SPOT
DBL SURFACE SPOT
RECESSED AND SCREWED
INTO GRID W/ ACRYLIC
DIFFUSER, REFER TO
ELECT. DRAWINGS FOR
FINAL LOCATION
W/ ACRYLIC DIFFUSER,
MOUNT TO CEILING
NOTE: REFER TO LUMINAIRE SCHEDULE & NOTES ON SHEET A7.4, SPECS AND ELECTRICAL DWGS FOR MOUNTING HEIGHTS,
LAMPING, AND ADDTL. INFO.
TV - 9'-6" AFF TO
B.O., UNO
REMOVE AND SALVAGE EXISTING LIGHT FIXTURE, REPAIR
SURFACES IF REQD., REUSE CIRCUIT FOR NEW ADJACENT
FIXTURE AS APPLICABLE
DEMO ALL EXISTING 'UMBRELLA' FIXTURES. REUSE CIRCUITS
FOR NEW LIGHTING LAYOUT.
HOOD LIGHTING NOTE: USE 2700K OR LOWER CFL'S
CENTER FIXTURE ON CEILING IN SPACE
REPAIR CEILING AS REQ'D TO MATCH ADJ. SURFACE
FOLLOWING REMOVAL OF CHANNEL AND FULL HT. GLAZING.
RELOCATE POWER & DATA AS REQUIRED TO NEW SIDE
HOSTESS STAND.
RELOCATE LIGHT TRACKS TO B.O. NEW WOOD SOFFIT IN
SAME LOCATION.
RELOCATED LIGHT TRACK, REUSE EXISTING CIRCUITS.
OPEN
REPAIR CEILING AS REQUIRED TO MATCH ADJ., FOLLOWING
DEMO OF PARTITION
RELOCATE DIFFUSERS TO NEW CEILING, FINISH TRIM TO
MATCH, FIELD ADJUST AIR FLOW BALANCE
CENTER FIXTURES ON TABLE TOP, TYPICAL FOR ALL 'A_'
FIXTURES
CENTER BOOTH FIXTURES ON TABLE TOP, TYPICAL FOR ALL
'B' FIXTURES, WHERE APPLICABLE.
NEW GYP BD CEILING, FINISH AND HEIGHT TO MATCH
ADJACENT HOST CEILING @ 9'-0"
RELOCATE EXISTING EXITING FIXTURES TO NEW NOTED
LOCATION, MATCH EXIST. HEIGHT, IF REQUIRED.
TOP OF TV AT 8'-9" AFF
EXISTING EXIT LIGHTING TO REMAIN 'AS-IS', TYPICAL.
REMOVE EXISTING FIXTURE, INSTALL NEW FIXTURE @
LOCATION, SEE LUMINAIRE SCHEDULE FOR TYPE.
EXISTING DIFFUSERS TO REMAIN 'AS-IS', TYPICAL FOR ALL
HVAC, GC TO CONTACT ARCHITECT PRIOR TO CONSTRUCTION
IF HEIGHT CONFLICT ARISES W/ NEW CONSTRUCTION, SHOP
PAINT TO MATCH ADJACENT FINISH IF ALTERED.
T-GRID CEILING & TILES CONTINUE OVER DROP SOFFIT.
PLUG MOLD POWER INSIDE BAR DIE, CONTINUOUS BELOW
TOP, SEE DETAIL 1/A8.2
BOOTH LIGHTING CENTERED ON TOPS, AT HEIGHT PER
LUMINAIRE SCHEDULE, TYPICAL.
DEMO FALSE (LOWER) T-GRID CEILING. UPPER T-GRID
CEILING WITH ACOUSTIC TILES TO REMAIN.
TOP OF TV AT 10'-0" AFF
REMOVE ACOUSTICAL TILES AND PAINT GRID FLAT BLACK TO
MATCH TILES THROUGHOUT UPPER GRID.
RELOCATE EXISTING TRACK TO B.O. WOOD SOFFIT,
CENTERED AND ABOVE LOOSE TABLES.
RAISE TV'S 12"
CONTINUE EXISTING HEATER NORTH TO FULL HEIGHT
PARTITION
NEW HEADER, NORTH OF FULL HEIGHT PARTITION, MATCH
DEMO'D HEIGHT.
NO WORK BACK OF HOUSE
8
9
10
11
12
3
A7.4
3
A7.4
4
A7.4
C-4
10'-0"
18'-0"
16'-0"
C-4
10'-0"
21'-0"
14'-0"
13'-0"
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
3
2
2
2
2
2
2
2
2
2
SCALE:
WOOD CLOUD DETAIL
2 3" = 1'-0"
1
4" x 6" CVG FIR
3
4" GAP PAINT BLACK
CLOUD'S 3
4" x 12" BORDER
3
4" BLACK SPACER SET IN
3
4"
WOOD CLOUD UNIT #1
WOOD CLOUD UNIT #2
2
A7.3
29
C-1
6
16
16
11
11
C-3
14
14
25
25
21
23
C-5
9'-0"
24 28
29
10
C-1
9'-0"
C-1
C-1
C-1
12
19
8
8
C-6
8
26
C-1
26
26
12
19