HomeMy WebLinkAboutA7.4 RCP NOTES.pdf10'-0" A.F.F.
SOFFIT
B/ WOOD
FIELD VERIFICATION SUBMISSIONS:
CONTRACTOR SHALL VERIFY ALL FIELD DIMENSIONS AND
CONDITIONS WITH THE SITE AND REPORT ANY DISCREPANCIES,
ERRORS OR OMITTANCES TO TRAPP ARCHITECTURE PRIOR TO
CONSTRUCTION OR FABRICATION. THE INFORMATION CONTAINED
IN THESE DRAWINGS IS BASED ON EXISTING DRAWINGS AND MAY
NOT BE CURRENT TO THE BUILT CONDITIONS OF THE SITE.
COPYRIGHT
TRAPP ARCHITECTURE SHALL RETAIN ALL STATUARY, COMMON
LAW AND OTHER RESERVED RIGHTS. THESE DRAWINGS AND
RELATED DOCUMENTS SHALL NOT BE DUPLICATED, DISCLOSED
OR OTHERWISE WITHOUT WRITTEN CONSENT OF TRAPP
ARCHITECTURE.
PERMIT: APRIL 15, 2011
PATIO REFLECTED CEILING PLAN NOTES & DETAILS
1. REFER TO 'AS-BUILT' ELECTRICAL DRAWINGS FOR ADDITIONAL LIGHTING INFORMATION, AND FIXTURE SCHEDULE &
MOUNTING INFORMATION.
2. REFER TO BUILDING ELEVATIONS AND SECTIONS FOR EXTERIOR BUILDING MOUNTED LIGHTING, WHERE APPLICABLE.
3. REFER TO FINISH SCHEDULE FOR MISC. ITEMS TO BE FIELD PAINTED.
4. PROVIDE CEILING FINISHES AND HEIGHTS AS INDICATED ON THE FINISH SCHEDULE, UNLESS OTHERWISE NOTED ON THE
RCP.
5. G.C. SHALL COORDINATE THE INSTALLATION OF THE FINISH CEILING WITH THE E.C. TO ASSURE PROPER ALIGNMENT OF
LIGHT FIXTURES, MECHANICAL GRILLS, SPRINKLER HEADS, EXITS SIGNS, SPEAKERS, ETC. , VERIFY WITH RESTAURANT
DESIGNER IF THERE ARE ANY DISCREPANCIES.
6. ALL LIGHTS, SPEAKERS AND OTHER CEILING MOUNTED EQUIPMENT SHALL BE CENTERED IN THE CEILING TILE UNLESS
OTHERWISE NOTED. THE CENTERING OF BOOTH LIGHTS TAKES PRIORITY.
7. SPEAKER TRIMS, JUNCTION BOX PLATES, HVAC GRILLES, ETC. SHALL BE PAINTED IN SEMI-GLOSS OIL PAINT BY THE G.C. TO
MATCH THE CEILING ADJACENT, UNLESS OTHERWISE NOTED. THESE ITEMS TO BE REMOVED PRIOR TO PAINT AND
REINSTALLED.
8. THE AUDIO SUBCONTRACTOR IS RESPONSIBLE FOR DESIGNATING SPEAKER LOCATIONS THROUGHOUT THE FACILITY. FOR
PROPER INSTALLATION OF AUDIO EQUIPMENT, THE SUB SHALL COORDINATE ANY PROVISIONS NECESSARY BY THE G.C..
9. THE G.C. SHALL COORDINATE WITH THE E.C. TO PROVIDE PROPER SUPPORT OR BLOCKING REQUIRED FOR ALL LIGHT
FIXTURES AS REQUIRED.
10. SPACING OF HANGERS FOR SUSPENDED CEILING MUST NOT BE MORE THAN 4'-8" O.C.. FOR SUPPORTING THE ACOUSTICAL
CEILING GRID.
11. SUSPENDED ACOUSTICAL GRID SHALL BE CENTERED WITHIN EACH SPACE UNLESS INDICATED OTHERWISE AS A SPECIFIC
DIMENSION OR INDICATED GRID STARTING POINT.
12. ALL LIGHTING FIXTURES LOCATED ABOVE FIXED TABLE TOPS ARE TO BE CENTERED IN BOTH DIRECTIONS OVER THE TABLE.
CLOCK OUTLETS FOR BOOTH LIGHTING TO BE CENTERED 6" BELOW THE TABLE TOP. G.C. TO COORDINATE WITH BOOTH
MANUFACTURER AND RCP FOR FINAL LOCATION PRIOR TO WORK.
13. ALIGN CEILING DROPS WITH END OF WALL, FACE OF COLUMN ENCLOSURE OR ADJOINING CEILING DROP, ETC. UNLESS
OTHERWISE NOTED.
14. G.C. TO PROVIDE NECESSARY BLOCKING BEHIND BATTENS FOR ATTACHING, AT 1X WOOD CEILING (C-4).
15. ALL SPRINKLER HEADS TO REMAIN 'AS-IS' UNLESS REQUIRED BY FIELD INSPECTOR TO BE RELOCATED.
16. ALL HVAC SUPPLY/RETURNS TO REMAIN 'AS-IS' UNLESS HVAC CONTRACTOR DETERMINES A MOVE IS REQUIRED FOR
BALANCE.
17. ALL EXITING SIGNAGE, LIGHTING AND STROBES TO REMAIN 'AS-IS' UNLESS CONSTRUCTION CONFLICT REQUIRES
RELOCATION. NEW LOCATIONS TO BE CLOSE TO EXISTING AND PER CODE REQUIREMENTS.
18. GC AND HVAC CONTRACTOR TO COORDINATE W/ RESTAURANT OPERATIONS AND VERIFY EXISTING HEAT/COOL SOURCES
AT PATIO. DETERMINE BEST MEANS OF UTILIZING RTU (IF EXISTING) AND HEATERS FOR CONSISTENT, EASILY CONTROLLED
CLIMITIZATION. REMOVE HEATERS IF REQUIRED.
19. GC TO PROVIDE ALT/ADD NUMBER FOR CHANGING FLEXIBLE CONDUIT TO RIGID & PATIO HEATERS/LIGHTING THROUGHOUT.
REFLECTED CEILING PLAN NOTES
1. MOUNTING HEIGHTS FOR WALL MOUNTED FIXTURES ARE TO CENTERLINE OF WALL BRACKET/WALL PLATE. AT BOOTHS,
MOUNTING HEIGHT IS MEASURED FROM THE TOP OF BOOTH PLATFORM TO CENTER OF JUNCTION BOX.
2. MOUNTING HEIGHT FOR HANGING FIXTURES IS FROM FINISH FLOOR TO BOTTOM OF PENDANT SHADE.
3. DECORATIVE FIXTURES SHALL BE PROVIDED BY OWNER AND INSTALLED BY THE ELECTRICAL CONTRACTOR. SEE LIGHT
FIXTURE SCHEDULE.
4. TRIM RINGS TO BE FIELD PAINTED PRIOR TO INSTALLATION. COORDINATE WITH PAINTING CONTRACTOR, SUBMIT ALL
COLORS TO RESTAURANT DESIGNER FOR APPROVAL.
5. ALL LAMPS TO BE PROVIDED AND INSTALLED BY THE ELECTRICAL CONTRACTOR. SEE LIGHT FIXTURE SCHEDULE FOR
SPECIFICATIONS.
6. FAN CONTROLLERS SHALL BE PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR. SUBMIT SPECIFICATION TO
RESTAURANT DESIGNER PRIOR TO ORDERING.
7. DO NOT BREAK HEAT FINS ON DIMMERS. USE AT FULL CAPACITY.
8. ALL NEW DIMMERS SHALL BE FACTORY COLOR TO MATCH - EXISTING TO BE LUTRON 'NOVA' SERIES. GC TO NOTIFY TRAPP
ASSOCIATES OF DISCREPANCIES.
9. CONTRACTOR SHALL PROVIDE THREE (3) MATCHING DIMMERS IN ALL CAPACITIES AS OWNER SPARES, LEAVE IN OFFICE
FOLLOWING 'TURN-OVER'.
10. CONTRACTOR SHALL MOUNT PLASTIC DIMMER NAME PLATES WITH NAMES PROVIDED BY RESTAURANT DESIGNER BELOW
APPLICABLE DIMMERS.
11. PLUG MOLD SHALL BE INSTALLED CONTINUOUSLY UNDER BARTOP AT BAR DIE AND BE CONTROLLED BY SWITCH LOCATED
AT EXIT TO BAR. SOCKETS SHALL BE SET AT 18" O.C., 6" IN FROM TOP EDGE.
12. G.C. TO VERIFY EXIT SIGNS AND EMERGENCY LIGHTS ARE CONNECTED AHEAD OF NEW AND EXISTING SWITCHES IN
CIRCUIT. FIXTURES SHALL AUTOMATICALLY LIGHT UPON LOSS OF POWER. SEE ELECTRICAL DRAWINGS FOR LOCATIONS.
WHERE LOCALLY REQUIRED, CIRCUIT A MINIMUM NUMBER OF 24 HOUR EXIT AISLE LIGHTING. CONFIRM ALL LOCATIONS
AND FIXTURES WITH RESTAURANT DESIGNER. LOCATE TO PROVIDE NAME. ALLOWABLE WALL AREA FOR ART,
COORDINATE WITH RESTAURANT DESIGNER ON FINAL LOCATIONS PRIOR TO WORK.
13. INTERLOCK ALL TOILET ROOM LIGHT SWITCHES TO TOILET ROOM EXHAUST FANS, IF NOT CURRENTLY EXISTING.
14. THE SOUND SYSTEM EQUIPMENT AND ACCESSORIES ARE TO BE MODIFIED BY THE SOUND SYSTEM CONTRACTOR AND
COORDINATED WITH THE ELECTRICAL CONTRACTOR. THE ELECTRICAL CONTRACTOR SHALL PROVIDE CONDUITS
STUBBED TO THE CEILING SPACE FOR ALL CONTROLS AND SPEAKERS. VERIFY FINAL LOCATIONS AND MOUNTING
HEIGHTS WITH THE SOUND SYSTEM CONTRACTOR.
15. G.C. TO PROVIDE THE OWNER WITH INSTRUCTIONS FOR THE OPERATION OF ALL ELECTRICAL SYSTEMS.
16. G.C. TO PROVIDE THE OWNER WITH THREE (3) SETS OF MAINTENANCE AND OPERATIONS MANUALS FOR ALL ELECTRICAL
EQUIPMENT AS APPLICABLE.
17. THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR FINAL WIRING OF LIGHTING, POWER, PANELS, ETC. THE E.C. SHALL
VERIFY THAT ELECTRICAL TO ALL FOOD SERVICE EQUIPMENT, KITCHEN HOOD FANS, CONTROL PANELS, ETC., INCLUDING
INTERLOCKS, WIRING, AND HOOK-UPS IS SOUND AND TO CODE.
18. ALL RECEPTACLES, SWITCHING, ETC., USED IN PUBLIC AREAS ARE TO BE MOUNTED PER A.D.A. REQUIREMENTS.
19. G.C. TO PROVIDE OUTLET, CONDUIT, ETC., AS REQUIRED BY THE FIRE SUPPRESSION CONTRACTOR, IF REQUIRED.
20. E.C. TO PROVIDE ALT/ADD # FOR LED TRACK HEADS AT EXISTING TRACKS.
21. ALL NEW AND EXISTING UNISTRUT AND HANGING SUPPORT FOR LIGHT FIXTURES TO BE PAINTED: PT-3.
LIGHTING NOTES
GENERAL NOTES:
1. DIMENSIONS SHOWN ARE BETWEEN FINISH AND/OR CENTER OF FIXTURES.
2. WHEREVER POSSIBLE DIMENSIONS BETWEEN LIKE FIXTURES ARE ON
DIMENSIONAL GRID.
3. FOR ADDITIONAL MOUNTING INFORMATION REFER TO LUMINAIRE SCHEDULE
SHEET A7.4
4. FINISH EXPOSED HVAC DUCTWORK TO MATCH ADJACENT SURFACE.
5. ALL EXPOSED DUCTWORK TO BE MOUNTED TIGHT TO CEILING.
6. LIGHTING LOCATIONS TO TAKE PRECEDENCE OVER HVAC.
7. G.C. TO VERIFY ALL FIELD DIMENSIONS AND CONDITIONS AND REPORT ANY
DISCREPANCIES TO THE ARCHITECT PRIOR TO CONSTRUCTION OF
FABRICATION.
SCALE:
PATIO REFL. CLG. PLAN
1 1/4" = 1'-0"
KEYED NOTES:
INSTALL NEW SCREEN MATERIAL AT MAKE UP AIR OPENING
IN PATIO WALL @ CEILING.
RAISE EXISTING TV'S 12"
RAISE ALL EXISTING HEATERS 12" THROUGHOUT.
INSPECT EXISTING CO2 MONITORS THROUGHOUT PATIO
ROOF STRUCTURE AND PROVIDE REPORT OF
FUNCTIONALITY. INSTALL NEW AS REQUIRED PER
MANUFACTURER'S DIRECTION ON COVERAGE AND
LOCATION. BRING POWER TO LOCATIONS AS REQUIRED.
EXISTING PATIO COVER AND SIGNAGE TO REMAIN 'AS IS'
KEY LAMP FIXTURE
DESCRIPTION MOUNTING HEIGHT MANUFACTURER VOLT FURN
A1 (1) 60W
FROSTED "T"
LAMP
PENDANT CORD HUNG 8' BOTTOM OF FIXTURE TO F.F. DFORM
"PUCCIPENDANT" BIRCH
120V FBO
A2 (1) 60W A GE
SOFT PINK
PENDANT 36" ABOVE TABLE TOP TO BOTTOM
OF FIXTURE - DINING
HUBBARDTON 13 9602-07
OUTSIDE SHADE #36
FINISH # -10 BLACK
120V FBO
A3 (4) 60W A GE
SOFT PINK
PENDANT CORD HUNG
GRASS/GLASS
6'-6" AFF FORCAST #F1936 - 70 120V FBO
A4 (3) GE SOFT
PINK
PENDANT CAPIZ SHELL 36" ABOVE TABLE WEST ELM 120V FBO
A5 (1) 60W "G"
LAMP
WAVY PLASTIC 8'-0" AFF TRAPP CUSTOM
A6 (1) 60W A GE
SOFT PINK
PENDANT CORD HUNG
W/ ALABASTER SHADE
6'-0" AFF BOTTOM FORCAST #F5167NV W/
BLACK CORD
120V FBO
A7 (1) 60W GE
SOFT PINK
PENDANT CORD HUNG 8" BELOW BOTTOM OF CLOUD D FORM #UB96 36" DIA. IN
BIRCH "BASKET SAUCER"
120V FBO
A8 (3) 60W PENDANT 8'-0" AFF 120V FBO
A9 (1) 100W A GE
SOFT PINK
BIG CUTTLE PENDANT
CORD HUNG
6'-6" AFF BOTTOM LBL LIGHTING
LUMENS.COM
120V FBO
A10 (1) G9
HALOGEN
PENDANT HUBBARDTON
#13-6401-08-G218
#10 FINISH
120V FBO
A11 (1) PAR 30
75W NFL
PENDANT DN. CAN VARIES PRESCOLITE LITE
FORMS 6" CYLINDER
BLACK
130V FBO
A12 (1) 60W GE
SOFT PINK
PENDANT 36" ABOVE TABLE HUBBARDTON
#139590-36-10
#10 FINISH
120V FBO
B1 (1) 20W CFL WALL MOUNT 6'-0" AFF KICHLER #9059AG2
BLACK FINISH
130V FBO
B2 (2) 60W A GE
SOFT PINK
WALL MOUNT BOOTH
SCONCE W/ RED FLAME
SHADE
ALUMENT
LIGHTINGUNIVERSE.COM
130V FBO
B3 DOUBLE WALL MOUNT
SCONCE W/ PARCHMENT
SHADES
6'-0" AFF TALLER UNO PALACE
BJLIGHTING
130V FBO
B4 (1) 50W
XENON
WALL MOUNT W/
SLUMPED GLASS SHADE
IN BEACH AMBER
VARIES ULTRALIGHTS
-08154
130V FBO
B5 (2) 26W QUAD WALL MOUNT IN
STAINLESS STEEL W/
GLASS SHADE
VARIES UNTRALIGHTS
CUSTOM CHAPEL
SCONCE
120V FBO
B6 (2) 26W QUAD SOFFIT MOUNT
ALUMINUM DOWN LIGHT
SCONCE
CSL SILO DOWN WALL
LIGHT
YLIGHTING.COM
120V FBO
B8 (1) 15W CFL
2700K
WALL MOUNT EXT.
FIXTURE
ULTRALIGHTS
#9133L24-HO-IA
FBO
B9 (1) 60W A GE
SOFT PINK
WALL MOUNT INT.
FIXTURE
ULTRALIGHTS
#9133-HO-BLK
120V FBO
CC EXISTING HEATERS BASE - 12"
E EXISTING TO REMAIN
ER EXISTING RELOCATE
ED EXISTING REMOVE,
HOLD
F MR16 NSP
75W
TRACK FIXTURE WACLHTIVE
#LHT007L
130V BEC
G N/A CEILING FAN ALUM.
BODY & BLADES
MOTOR CONTROL F.B.O. MODERN FAN COMPANY
PENSI
YLIGHTING.COM
K (1) 60W A GE
SOFT PINK
60A/5PK
BARTOP MOUNTED
FIXTURE WIRE
THROUGH TOP
T.B.D. 130V FBO
M (1) 100W PAR
38 PL GE
WATTMAISER
RECESSED DOWNLIGHT
W/ BLACK STEP BAFFLE
61
4"
LIGHTOLIER #STEP
BAFFLE 1105MN
130V BEC
M1 (1) 100W PAR
30 FL GE
WATTMAISER
51
2" RECESSED DOWN
CAN
LIGHTOLIER
#1102P1 W/ 1179M1
BLACK BAFFLE
130V BEC
M2 (1) 50W PAR
20 GE
WATTMAISER
RECESSED DOWN CAN LIGHTOLIER
51
2" W/ 2005 MATTE
BLACK
130V BEC
M3 (1) 75W PAR
30 GE
WATTMAISER
63
4" APERTURE BAFFLED
EYEBALL REFLECTOR
LIGHTOLIER #1122 130V BEC
M4 5" APERTURE STEP
BAFFLE WALL WASHER
LIGHTOLIER # 1135
M5 6
3
4" APERTURE
SHALLOW SLOPE CLG.
REFLECTOR TRIM 14-30
ANGLE 31
2 - 7
1
2 PITCH
LIGHTOLIER #1131 130V BEC
T (3)
F32TBSPX35
2X4 SURFACE MOUNTED
FLUORSCENT
#2M332-A12125-ES W/
.125 ACRYLIC DIFFUSER.
ELECTRONIC BALLAST
SILVERED EGGCRATE
ELECTRONIC BALLAST
LITHONIA 25P8G332
A12125 M VOLT Y3
FEB101S
130V FBO
T2 3 F32TB SPX
35
2X4 FLUORESCENT-
TOFFER CLEAR PLASTIC
LENS W/ 3
4"X
3
4"X
3
4"
SILVERED EGGCRATE
ELECTRONIC BALLAST
LITHONIA 2SP8G332 PCIS
M VOLT 1/3 GEB 101S
130V FBO
LUMINAIRE SCHEDULE
SCALE:
'WOOD CLOUD' FRAMING SOFFIT
3 1" = 1'-0"
1X12 CVG FIR FASCIA 1/2" CDX PLYWOOD
1/4"X6" CVG FIR T&G GLUE &
EDGE NAIL OVER 1/2" CDX PLY
91
2" TJI #110
3/4" REVEAL, PAINT BLACK
SCALE:
WOOD SOFFIT
4 1" = 1'-0"
BLOCKING
PLAN VIEW
ALL THREAD
BLOCKING AS REQ'D.
1
2
3
4
3 5
3
3
3
3
3
3
3
3
3
3
4
4
4