HomeMy WebLinkAboutA7.4 RCP NOTES.pdf10'-0" A.F.F. SOFFIT B/ WOOD FIELD VERIFICATION SUBMISSIONS: CONTRACTOR SHALL VERIFY ALL FIELD DIMENSIONS AND CONDITIONS WITH THE SITE AND REPORT ANY DISCREPANCIES, ERRORS OR OMITTANCES TO TRAPP ARCHITECTURE PRIOR TO CONSTRUCTION OR FABRICATION. THE INFORMATION CONTAINED IN THESE DRAWINGS IS BASED ON EXISTING DRAWINGS AND MAY NOT BE CURRENT TO THE BUILT CONDITIONS OF THE SITE. COPYRIGHT TRAPP ARCHITECTURE SHALL RETAIN ALL STATUARY, COMMON LAW AND OTHER RESERVED RIGHTS. THESE DRAWINGS AND RELATED DOCUMENTS SHALL NOT BE DUPLICATED, DISCLOSED OR OTHERWISE WITHOUT WRITTEN CONSENT OF TRAPP ARCHITECTURE. PERMIT: APRIL 15, 2011 PATIO REFLECTED CEILING PLAN NOTES & DETAILS 1. REFER TO 'AS-BUILT' ELECTRICAL DRAWINGS FOR ADDITIONAL LIGHTING INFORMATION, AND FIXTURE SCHEDULE & MOUNTING INFORMATION. 2. REFER TO BUILDING ELEVATIONS AND SECTIONS FOR EXTERIOR BUILDING MOUNTED LIGHTING, WHERE APPLICABLE. 3. REFER TO FINISH SCHEDULE FOR MISC. ITEMS TO BE FIELD PAINTED. 4. PROVIDE CEILING FINISHES AND HEIGHTS AS INDICATED ON THE FINISH SCHEDULE, UNLESS OTHERWISE NOTED ON THE RCP. 5. G.C. SHALL COORDINATE THE INSTALLATION OF THE FINISH CEILING WITH THE E.C. TO ASSURE PROPER ALIGNMENT OF LIGHT FIXTURES, MECHANICAL GRILLS, SPRINKLER HEADS, EXITS SIGNS, SPEAKERS, ETC. , VERIFY WITH RESTAURANT DESIGNER IF THERE ARE ANY DISCREPANCIES. 6. ALL LIGHTS, SPEAKERS AND OTHER CEILING MOUNTED EQUIPMENT SHALL BE CENTERED IN THE CEILING TILE UNLESS OTHERWISE NOTED. THE CENTERING OF BOOTH LIGHTS TAKES PRIORITY. 7. SPEAKER TRIMS, JUNCTION BOX PLATES, HVAC GRILLES, ETC. SHALL BE PAINTED IN SEMI-GLOSS OIL PAINT BY THE G.C. TO MATCH THE CEILING ADJACENT, UNLESS OTHERWISE NOTED. THESE ITEMS TO BE REMOVED PRIOR TO PAINT AND REINSTALLED. 8. THE AUDIO SUBCONTRACTOR IS RESPONSIBLE FOR DESIGNATING SPEAKER LOCATIONS THROUGHOUT THE FACILITY. FOR PROPER INSTALLATION OF AUDIO EQUIPMENT, THE SUB SHALL COORDINATE ANY PROVISIONS NECESSARY BY THE G.C.. 9. THE G.C. SHALL COORDINATE WITH THE E.C. TO PROVIDE PROPER SUPPORT OR BLOCKING REQUIRED FOR ALL LIGHT FIXTURES AS REQUIRED. 10. SPACING OF HANGERS FOR SUSPENDED CEILING MUST NOT BE MORE THAN 4'-8" O.C.. FOR SUPPORTING THE ACOUSTICAL CEILING GRID. 11. SUSPENDED ACOUSTICAL GRID SHALL BE CENTERED WITHIN EACH SPACE UNLESS INDICATED OTHERWISE AS A SPECIFIC DIMENSION OR INDICATED GRID STARTING POINT. 12. ALL LIGHTING FIXTURES LOCATED ABOVE FIXED TABLE TOPS ARE TO BE CENTERED IN BOTH DIRECTIONS OVER THE TABLE. CLOCK OUTLETS FOR BOOTH LIGHTING TO BE CENTERED 6" BELOW THE TABLE TOP. G.C. TO COORDINATE WITH BOOTH MANUFACTURER AND RCP FOR FINAL LOCATION PRIOR TO WORK. 13. ALIGN CEILING DROPS WITH END OF WALL, FACE OF COLUMN ENCLOSURE OR ADJOINING CEILING DROP, ETC. UNLESS OTHERWISE NOTED. 14. G.C. TO PROVIDE NECESSARY BLOCKING BEHIND BATTENS FOR ATTACHING, AT 1X WOOD CEILING (C-4). 15. ALL SPRINKLER HEADS TO REMAIN 'AS-IS' UNLESS REQUIRED BY FIELD INSPECTOR TO BE RELOCATED. 16. ALL HVAC SUPPLY/RETURNS TO REMAIN 'AS-IS' UNLESS HVAC CONTRACTOR DETERMINES A MOVE IS REQUIRED FOR BALANCE. 17. ALL EXITING SIGNAGE, LIGHTING AND STROBES TO REMAIN 'AS-IS' UNLESS CONSTRUCTION CONFLICT REQUIRES RELOCATION. NEW LOCATIONS TO BE CLOSE TO EXISTING AND PER CODE REQUIREMENTS. 18. GC AND HVAC CONTRACTOR TO COORDINATE W/ RESTAURANT OPERATIONS AND VERIFY EXISTING HEAT/COOL SOURCES AT PATIO. DETERMINE BEST MEANS OF UTILIZING RTU (IF EXISTING) AND HEATERS FOR CONSISTENT, EASILY CONTROLLED CLIMITIZATION. REMOVE HEATERS IF REQUIRED. 19. GC TO PROVIDE ALT/ADD NUMBER FOR CHANGING FLEXIBLE CONDUIT TO RIGID & PATIO HEATERS/LIGHTING THROUGHOUT. REFLECTED CEILING PLAN NOTES 1. MOUNTING HEIGHTS FOR WALL MOUNTED FIXTURES ARE TO CENTERLINE OF WALL BRACKET/WALL PLATE. AT BOOTHS, MOUNTING HEIGHT IS MEASURED FROM THE TOP OF BOOTH PLATFORM TO CENTER OF JUNCTION BOX. 2. MOUNTING HEIGHT FOR HANGING FIXTURES IS FROM FINISH FLOOR TO BOTTOM OF PENDANT SHADE. 3. DECORATIVE FIXTURES SHALL BE PROVIDED BY OWNER AND INSTALLED BY THE ELECTRICAL CONTRACTOR. SEE LIGHT FIXTURE SCHEDULE. 4. TRIM RINGS TO BE FIELD PAINTED PRIOR TO INSTALLATION. COORDINATE WITH PAINTING CONTRACTOR, SUBMIT ALL COLORS TO RESTAURANT DESIGNER FOR APPROVAL. 5. ALL LAMPS TO BE PROVIDED AND INSTALLED BY THE ELECTRICAL CONTRACTOR. SEE LIGHT FIXTURE SCHEDULE FOR SPECIFICATIONS. 6. FAN CONTROLLERS SHALL BE PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR. SUBMIT SPECIFICATION TO RESTAURANT DESIGNER PRIOR TO ORDERING. 7. DO NOT BREAK HEAT FINS ON DIMMERS. USE AT FULL CAPACITY. 8. ALL NEW DIMMERS SHALL BE FACTORY COLOR TO MATCH - EXISTING TO BE LUTRON 'NOVA' SERIES. GC TO NOTIFY TRAPP ASSOCIATES OF DISCREPANCIES. 9. CONTRACTOR SHALL PROVIDE THREE (3) MATCHING DIMMERS IN ALL CAPACITIES AS OWNER SPARES, LEAVE IN OFFICE FOLLOWING 'TURN-OVER'. 10. CONTRACTOR SHALL MOUNT PLASTIC DIMMER NAME PLATES WITH NAMES PROVIDED BY RESTAURANT DESIGNER BELOW APPLICABLE DIMMERS. 11. PLUG MOLD SHALL BE INSTALLED CONTINUOUSLY UNDER BARTOP AT BAR DIE AND BE CONTROLLED BY SWITCH LOCATED AT EXIT TO BAR. SOCKETS SHALL BE SET AT 18" O.C., 6" IN FROM TOP EDGE. 12. G.C. TO VERIFY EXIT SIGNS AND EMERGENCY LIGHTS ARE CONNECTED AHEAD OF NEW AND EXISTING SWITCHES IN CIRCUIT. FIXTURES SHALL AUTOMATICALLY LIGHT UPON LOSS OF POWER. SEE ELECTRICAL DRAWINGS FOR LOCATIONS. WHERE LOCALLY REQUIRED, CIRCUIT A MINIMUM NUMBER OF 24 HOUR EXIT AISLE LIGHTING. CONFIRM ALL LOCATIONS AND FIXTURES WITH RESTAURANT DESIGNER. LOCATE TO PROVIDE NAME. ALLOWABLE WALL AREA FOR ART, COORDINATE WITH RESTAURANT DESIGNER ON FINAL LOCATIONS PRIOR TO WORK. 13. INTERLOCK ALL TOILET ROOM LIGHT SWITCHES TO TOILET ROOM EXHAUST FANS, IF NOT CURRENTLY EXISTING. 14. THE SOUND SYSTEM EQUIPMENT AND ACCESSORIES ARE TO BE MODIFIED BY THE SOUND SYSTEM CONTRACTOR AND COORDINATED WITH THE ELECTRICAL CONTRACTOR. THE ELECTRICAL CONTRACTOR SHALL PROVIDE CONDUITS STUBBED TO THE CEILING SPACE FOR ALL CONTROLS AND SPEAKERS. VERIFY FINAL LOCATIONS AND MOUNTING HEIGHTS WITH THE SOUND SYSTEM CONTRACTOR. 15. G.C. TO PROVIDE THE OWNER WITH INSTRUCTIONS FOR THE OPERATION OF ALL ELECTRICAL SYSTEMS. 16. G.C. TO PROVIDE THE OWNER WITH THREE (3) SETS OF MAINTENANCE AND OPERATIONS MANUALS FOR ALL ELECTRICAL EQUIPMENT AS APPLICABLE. 17. THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR FINAL WIRING OF LIGHTING, POWER, PANELS, ETC. THE E.C. SHALL VERIFY THAT ELECTRICAL TO ALL FOOD SERVICE EQUIPMENT, KITCHEN HOOD FANS, CONTROL PANELS, ETC., INCLUDING INTERLOCKS, WIRING, AND HOOK-UPS IS SOUND AND TO CODE. 18. ALL RECEPTACLES, SWITCHING, ETC., USED IN PUBLIC AREAS ARE TO BE MOUNTED PER A.D.A. REQUIREMENTS. 19. G.C. TO PROVIDE OUTLET, CONDUIT, ETC., AS REQUIRED BY THE FIRE SUPPRESSION CONTRACTOR, IF REQUIRED. 20. E.C. TO PROVIDE ALT/ADD # FOR LED TRACK HEADS AT EXISTING TRACKS. 21. ALL NEW AND EXISTING UNISTRUT AND HANGING SUPPORT FOR LIGHT FIXTURES TO BE PAINTED: PT-3. LIGHTING NOTES GENERAL NOTES: 1. DIMENSIONS SHOWN ARE BETWEEN FINISH AND/OR CENTER OF FIXTURES. 2. WHEREVER POSSIBLE DIMENSIONS BETWEEN LIKE FIXTURES ARE ON DIMENSIONAL GRID. 3. FOR ADDITIONAL MOUNTING INFORMATION REFER TO LUMINAIRE SCHEDULE SHEET A7.4 4. FINISH EXPOSED HVAC DUCTWORK TO MATCH ADJACENT SURFACE. 5. ALL EXPOSED DUCTWORK TO BE MOUNTED TIGHT TO CEILING. 6. LIGHTING LOCATIONS TO TAKE PRECEDENCE OVER HVAC. 7. G.C. TO VERIFY ALL FIELD DIMENSIONS AND CONDITIONS AND REPORT ANY DISCREPANCIES TO THE ARCHITECT PRIOR TO CONSTRUCTION OF FABRICATION. SCALE: PATIO REFL. CLG. PLAN 1 1/4" = 1'-0" KEYED NOTES: INSTALL NEW SCREEN MATERIAL AT MAKE UP AIR OPENING IN PATIO WALL @ CEILING. RAISE EXISTING TV'S 12" RAISE ALL EXISTING HEATERS 12" THROUGHOUT. INSPECT EXISTING CO2 MONITORS THROUGHOUT PATIO ROOF STRUCTURE AND PROVIDE REPORT OF FUNCTIONALITY. INSTALL NEW AS REQUIRED PER MANUFACTURER'S DIRECTION ON COVERAGE AND LOCATION. BRING POWER TO LOCATIONS AS REQUIRED. EXISTING PATIO COVER AND SIGNAGE TO REMAIN 'AS IS' KEY LAMP FIXTURE DESCRIPTION MOUNTING HEIGHT MANUFACTURER VOLT FURN A1 (1) 60W FROSTED "T" LAMP PENDANT CORD HUNG 8' BOTTOM OF FIXTURE TO F.F. DFORM "PUCCIPENDANT" BIRCH 120V FBO A2 (1) 60W A GE SOFT PINK PENDANT 36" ABOVE TABLE TOP TO BOTTOM OF FIXTURE - DINING HUBBARDTON 13 9602-07 OUTSIDE SHADE #36 FINISH # -10 BLACK 120V FBO A3 (4) 60W A GE SOFT PINK PENDANT CORD HUNG GRASS/GLASS 6'-6" AFF FORCAST #F1936 - 70 120V FBO A4 (3) GE SOFT PINK PENDANT CAPIZ SHELL 36" ABOVE TABLE WEST ELM 120V FBO A5 (1) 60W "G" LAMP WAVY PLASTIC 8'-0" AFF TRAPP CUSTOM A6 (1) 60W A GE SOFT PINK PENDANT CORD HUNG W/ ALABASTER SHADE 6'-0" AFF BOTTOM FORCAST #F5167NV W/ BLACK CORD 120V FBO A7 (1) 60W GE SOFT PINK PENDANT CORD HUNG 8" BELOW BOTTOM OF CLOUD D FORM #UB96 36" DIA. IN BIRCH "BASKET SAUCER" 120V FBO A8 (3) 60W PENDANT 8'-0" AFF 120V FBO A9 (1) 100W A GE SOFT PINK BIG CUTTLE PENDANT CORD HUNG 6'-6" AFF BOTTOM LBL LIGHTING LUMENS.COM 120V FBO A10 (1) G9 HALOGEN PENDANT HUBBARDTON #13-6401-08-G218 #10 FINISH 120V FBO A11 (1) PAR 30 75W NFL PENDANT DN. CAN VARIES PRESCOLITE LITE FORMS 6" CYLINDER BLACK 130V FBO A12 (1) 60W GE SOFT PINK PENDANT 36" ABOVE TABLE HUBBARDTON #139590-36-10 #10 FINISH 120V FBO B1 (1) 20W CFL WALL MOUNT 6'-0" AFF KICHLER #9059AG2 BLACK FINISH 130V FBO B2 (2) 60W A GE SOFT PINK WALL MOUNT BOOTH SCONCE W/ RED FLAME SHADE ALUMENT LIGHTINGUNIVERSE.COM 130V FBO B3 DOUBLE WALL MOUNT SCONCE W/ PARCHMENT SHADES 6'-0" AFF TALLER UNO PALACE BJLIGHTING 130V FBO B4 (1) 50W XENON WALL MOUNT W/ SLUMPED GLASS SHADE IN BEACH AMBER VARIES ULTRALIGHTS -08154 130V FBO B5 (2) 26W QUAD WALL MOUNT IN STAINLESS STEEL W/ GLASS SHADE VARIES UNTRALIGHTS CUSTOM CHAPEL SCONCE 120V FBO B6 (2) 26W QUAD SOFFIT MOUNT ALUMINUM DOWN LIGHT SCONCE CSL SILO DOWN WALL LIGHT YLIGHTING.COM 120V FBO B8 (1) 15W CFL 2700K WALL MOUNT EXT. FIXTURE ULTRALIGHTS #9133L24-HO-IA FBO B9 (1) 60W A GE SOFT PINK WALL MOUNT INT. FIXTURE ULTRALIGHTS #9133-HO-BLK 120V FBO CC EXISTING HEATERS BASE - 12" E EXISTING TO REMAIN ER EXISTING RELOCATE ED EXISTING REMOVE, HOLD F MR16 NSP 75W TRACK FIXTURE WACLHTIVE #LHT007L 130V BEC G N/A CEILING FAN ALUM. BODY & BLADES MOTOR CONTROL F.B.O. MODERN FAN COMPANY PENSI YLIGHTING.COM K (1) 60W A GE SOFT PINK 60A/5PK BARTOP MOUNTED FIXTURE WIRE THROUGH TOP T.B.D. 130V FBO M (1) 100W PAR 38 PL GE WATTMAISER RECESSED DOWNLIGHT W/ BLACK STEP BAFFLE 61 4" LIGHTOLIER #STEP BAFFLE 1105MN 130V BEC M1 (1) 100W PAR 30 FL GE WATTMAISER 51 2" RECESSED DOWN CAN LIGHTOLIER #1102P1 W/ 1179M1 BLACK BAFFLE 130V BEC M2 (1) 50W PAR 20 GE WATTMAISER RECESSED DOWN CAN LIGHTOLIER 51 2" W/ 2005 MATTE BLACK 130V BEC M3 (1) 75W PAR 30 GE WATTMAISER 63 4" APERTURE BAFFLED EYEBALL REFLECTOR LIGHTOLIER #1122 130V BEC M4 5" APERTURE STEP BAFFLE WALL WASHER LIGHTOLIER # 1135 M5 6 3 4" APERTURE SHALLOW SLOPE CLG. REFLECTOR TRIM 14-30 ANGLE 31 2 - 7 1 2 PITCH LIGHTOLIER #1131 130V BEC T (3) F32TBSPX35 2X4 SURFACE MOUNTED FLUORSCENT #2M332-A12125-ES W/ .125 ACRYLIC DIFFUSER. ELECTRONIC BALLAST SILVERED EGGCRATE ELECTRONIC BALLAST LITHONIA 25P8G332 A12125 M VOLT Y3 FEB101S 130V FBO T2 3 F32TB SPX 35 2X4 FLUORESCENT- TOFFER CLEAR PLASTIC LENS W/ 3 4"X 3 4"X 3 4" SILVERED EGGCRATE ELECTRONIC BALLAST LITHONIA 2SP8G332 PCIS M VOLT 1/3 GEB 101S 130V FBO LUMINAIRE SCHEDULE SCALE: 'WOOD CLOUD' FRAMING SOFFIT 3 1" = 1'-0" 1X12 CVG FIR FASCIA 1/2" CDX PLYWOOD 1/4"X6" CVG FIR T&G GLUE & EDGE NAIL OVER 1/2" CDX PLY 91 2" TJI #110 3/4" REVEAL, PAINT BLACK SCALE: WOOD SOFFIT 4 1" = 1'-0" BLOCKING PLAN VIEW ALL THREAD BLOCKING AS REQ'D. 1 2 3 4 3 5 3 3 3 3 3 3 3 3 3 3 4 4 4