HomeMy WebLinkAboutA8.3 RESTROOMS.pdfRESTROOMS
FIELD VERIFICATION SUBMISSIONS:
CONTRACTOR SHALL VERIFY ALL FIELD DIMENSIONS AND
CONDITIONS WITH THE SITE AND REPORT ANY DISCREPANCIES,
ERRORS OR OMITTANCES TO TRAPP ARCHITECTURE PRIOR TO
CONSTRUCTION OR FABRICATION. THE INFORMATION CONTAINED
IN THESE DRAWINGS IS BASED ON EXISTING DRAWINGS AND MAY
NOT BE CURRENT TO THE BUILT CONDITIONS OF THE SITE.
COPYRIGHT
TRAPP ARCHITECTURE SHALL RETAIN ALL STATUARY, COMMON
LAW AND OTHER RESERVED RIGHTS. THESE DRAWINGS AND
RELATED DOCUMENTS SHALL NOT BE DUPLICATED, DISCLOSED
OR OTHERWISE WITHOUT WRITTEN CONSENT OF TRAPP
ARCHITECTURE.
PERMIT: APRIL 15, 2011
SCALE:
WEST WOMEN'S WALL
4 3/8" = 1'-0"
FULL HEIGHT TILE ROWS TO BEGIN @
CEILING, REMAINING 6" +/- CUT @ BOTTOM
ROW, TYP. @ ALL WALLS BOTH RESTROOMS
DEMO EXISTING MIRRORS. INSTALL NEW FBO
MIRRORS
DEMO EXIST. SCONCES. RELOCATE PWR. TO
CEILING ABOVE LAV TOP FOR (2) NEW 'M'
FIXTURES.
ALL RESTROOM HDWE. INCL.: GRAB
BARS, DISPENSERS TO BE REMOVED
AND REINSTALLED AS REQD. FOR
CONSISTENT INSTALLATION OF NEW
STONE TILE, TYP. @ BOTH
RESTROOMS
SCALE:
NORTH WOMEN'S WALL
1 3/8" = 1'-0" SCALE:
EAST WOMEN'S WALL
2 3/8" = 1'-0" SCALE:
SOUTH WOMEN'S WALL
3 3/8" = 1'-0"
SCALE:
NORTH MEN'S WALL
5 3/8" = 1'-0" SCALE:
EAST MEN'S WALL
6 3/8" = 1'-0"
NEW 16X16 STONE TILE (SN-3) FLOOR
TO CEILING THROUGHOUT BOTH
RESTROOMS, BUTT JOIN W/ MIN.
GROUT TO MATCH
SCALE:
SOUTH MEN'S WALL
7 3/8" = 1'-0" SCALE:
WEST MEN'S WALL
8 3/8" = 1'-0"
SCALE:
LAV TOP
10 1" = 1'-0"
SCALE:
LOW WALL TILE NOSE
9 1-1/2" = 1'-0"
SECTION PLAN
1X3 TUBE STEEL PWDR. COATED
SATIN SILVER, BELOW STONE LAV
TOP, SADDLE AS REQD. TO
ATTACH TO STONE
4X4X1/4" PLATE WELDED TO 1X3
BRACKET AND ANCHORED INTO
2X BLOCKING BETWEEN STUDS IN
WALL, ADD 2X BLOCKING BELOW
HORIZONTAL BLOCKING FOR
VERTICAL SUPPORT
NEW STONE TILE
EXISTING STUDS
EXISTING GYP. BD.
BACK WALL
GUEST SIDE
633
4"
21
2" 2
1
2"
24"
21
2"
DEMO EXISTING MIXERS, INSTALL NEW
FBO MIXERS AND SOAP DISPENSERS W/
NEW LAV. USING EXISTING PLUMBING
NEW 2-5/8" STONE LAV TOP, FBO,
INSTALLED BGC
OVERMOUNT SINKS LOCATED
AND INSTALLED BY STONE
VENDOR, DIMENSIONS PROVIDED
BGC PRIOR TO FABRICATION
FULL CAP TILE, FOLLOW VERTICAL
GROUT PATTERN, HAND EASE EDGES
EXISTING OR NEW P.T.
AS REQUIRED FRAMING
EXISTING GYP. BD.
FULL CAP TILE, FOLLOW
HORIZONTAL GROUT
PATTERN, HAND EASE
EDGES
EXISTING OR NEW
P.T. AS REQUIRED
FRAMING
EXISTING GYP. BD.
NEW STONE TILE
NEW STONE TILE
DEMO EXISTING MIXERS, INSTALL
NEW FBO MIXERS AND SOAP
DISPENSERS W/ NEW LAV. USING
EXISTING PLUMBING
SN-3
SN-3
SN-3
SN-3 SN-3
SN-3
NEW FULL-LITE
MAHOGANY DOOR
W/ PPG 'RAIN GLASS'
PATTERN. REUSE
EXISTING
HARDWARE
DEMO EXISTING MIRRORS.
INSTALL NEW FBO MIRRORS
DEMO EXIST. SCONCES.
RELOCATE PWR. TO CEILING
ABOVE LAV TOP FOR (2) NEW
'M' FIXTURES
DEMO EXISTING MIXERS, INSTALL
NEW FBO MIXERS AND SOAP
DISPENSERS W/ NEW LAV. USING
EXISTING PLUMBING
9
A8.3
9
A8.3
REMOVE MIRROR. RECUT AND
RELOCATE.
ALL RESTROOM HDWE. INCL.: GRAB
BARS, DISPENSERS TO BE REMOVED
AND REINSTALLED AS REQD. FOR
CONSISTENT INSTALLATION OF NEW
STONE TILE, TYP. @ BOTH RESTROOMS
DEMO EXISTING WALL TILE,
INCLUDING BASE, REPAIR
SUBSTRATE AS REQD. TO
ACCEPT NEW STONE TILE SPEC.
NEW S.S. PARTITIONS TO MATCH EXISTING SIZES
AND LOCATIONS TYP. OF BOTH RESTROOMS
GENERAL NOTES:
1. G.C. TO FIELD VERIFY/CORRECT FAN AND
VENTING AT BOTH RESTROOMS TO ENSURE
MAXIMUM AMOUNT OF AIR FLOW.
EXISTING PAPER TOWEL
DISP. TO BE REMOVED AND
REINSTALLED FOLLOWING
WALL TILE INSTALLATION
FULL HEIGHT TILE ROWS TO BEGIN @
CEILING, REMAINING 6" +/- CUT @ BOTTOM
ROW, TYP. @ ALL WALLS BOTH RESTROOMS
REMOVE MIRROR
REMOVE EXISTING FIXTURE
FULL HEIGHT TILE ROWS TO BEGIN @
CEILING, REMAINING 6" +/- CUT @ BOTTOM
ROW, TYP. @ ALL WALLS BOTH RESTROOMS
PT-2 PT-2 PT-2
PT-2 PT-2
PT-2
ALL PLUMBING
INCLUDING
ESCUTCHEONS TO BE
SHINY CHROME.
DEMO EXISTING
GRANITE LAV. REPAIR
SURFACES AS
REQUIRED TO ACCEPT
NEW FINISHES.
ADJUST DRAIN TO 25"
AFF
25"
ALL RESTROOM HDWE. INCL.: GRAB
BARS, DISPENSERS TO BE REMOVED
AND REINSTALLED AS REQD. FOR
CONSISTENT INSTALLATION OF NEW
STONE TILE, TYP. @ BOTH RESTROOMS
ALL PLUMBING
INCLUDING
ESCUTCHEONS TO
BE SHINY
CHROME.
DEMO EXISTING
GRANITE LAV.
REPAIR SURFACES
AS REQUIRED TO
ACCEPT NEW
FINISHES.
NEW S.S. PARTITIONS TO MATCH EXISTING SIZES
AND LOCATIONS TYP. OF BOTH RESTROOMS
EXISTING PAPER TOWEL
DISP. TO BE REMOVED AND
REINSTALLED FOLLOWING
WALL TILE INSTALLATION
NEW S.S. PARTITIONS TO MATCH EXISTING SIZES
AND LOCATIONS TYP. OF BOTH RESTROOMS
FULL HEIGHT TILE ROWS TO BEGIN @
CEILING, REMAINING 6" +/- CUT @ BOTTOM
ROW, TYP. @ ALL WALLS BOTH RESTROOMS
DEMO EXISTING WALL TILE,
INCLUDING BASE, REPAIR
SUBSTRATE AS REQD. TO
ACCEPT NEW STONE TILE SPEC.
SN-3
PT-2
34"
MAX.
27" MIN.
ALL RESTROOM HDWE. INCL.: GRAB
BARS, DISPENSERS TO BE REMOVED
AND REINSTALLED AS REQD. FOR
CONSISTENT INSTALLATION OF NEW
STONE TILE, TYP. @ BOTH RESTROOMS
34"
MAX.
27" MIN.
25"
NEW FULL-LITE
MAHOGANY DOOR W/
PPG 'RAIN GLASS'
PATTERN. REUSE
EXISTING HARDWARE
SCALE:
TOILET ROOMS PLAN
11 3/8" = 1'-0"
8 -
A8.3
5
7
6
4 -
A8.3
1
3
2
RECUT MIRROR AND
RELOCATE, 36"x60"
MOUNT OVER STONE TILE
REMOVE MIRROR
26"
RECUT MIRROR, MOUNT ON NEW WALL
TILE (SN-3)
LOW WALL TO BE DEMO'D AND
REBUILT W/ P.T.
REMOVE PANEL
NOTE:
"0" GROUT JOINTS -
FILL VOIDS W/ THIN
GROUT TO MATCH
COLOR.
COVE GROUT JOINT,
TYPICAL
NOTE:
"0" GROUT JOINTS -
FILL VOIDS W/ THIN
GROUT TO MATCH
COLOR.
COVE GROUT JOINT,
TYPICAL
LOW WALL TO BE DEMO'D AND
REBUILT W/ P.T.
REMOVE PANEL
NOTE:
GC TO LOCATE REBUILT LOW WALL IN BOTH RESTROOMS TO
ACCOMMODATE DIMENSIONS AS SHOWN PER NEW LAV TOP.