Loading...
HomeMy WebLinkAboutA8.3 RESTROOMS.pdfRESTROOMS FIELD VERIFICATION SUBMISSIONS: CONTRACTOR SHALL VERIFY ALL FIELD DIMENSIONS AND CONDITIONS WITH THE SITE AND REPORT ANY DISCREPANCIES, ERRORS OR OMITTANCES TO TRAPP ARCHITECTURE PRIOR TO CONSTRUCTION OR FABRICATION. THE INFORMATION CONTAINED IN THESE DRAWINGS IS BASED ON EXISTING DRAWINGS AND MAY NOT BE CURRENT TO THE BUILT CONDITIONS OF THE SITE. COPYRIGHT TRAPP ARCHITECTURE SHALL RETAIN ALL STATUARY, COMMON LAW AND OTHER RESERVED RIGHTS. THESE DRAWINGS AND RELATED DOCUMENTS SHALL NOT BE DUPLICATED, DISCLOSED OR OTHERWISE WITHOUT WRITTEN CONSENT OF TRAPP ARCHITECTURE. PERMIT: APRIL 15, 2011 SCALE: WEST WOMEN'S WALL 4 3/8" = 1'-0" FULL HEIGHT TILE ROWS TO BEGIN @ CEILING, REMAINING 6" +/- CUT @ BOTTOM ROW, TYP. @ ALL WALLS BOTH RESTROOMS DEMO EXISTING MIRRORS. INSTALL NEW FBO MIRRORS DEMO EXIST. SCONCES. RELOCATE PWR. TO CEILING ABOVE LAV TOP FOR (2) NEW 'M' FIXTURES. ALL RESTROOM HDWE. INCL.: GRAB BARS, DISPENSERS TO BE REMOVED AND REINSTALLED AS REQD. FOR CONSISTENT INSTALLATION OF NEW STONE TILE, TYP. @ BOTH RESTROOMS SCALE: NORTH WOMEN'S WALL 1 3/8" = 1'-0" SCALE: EAST WOMEN'S WALL 2 3/8" = 1'-0" SCALE: SOUTH WOMEN'S WALL 3 3/8" = 1'-0" SCALE: NORTH MEN'S WALL 5 3/8" = 1'-0" SCALE: EAST MEN'S WALL 6 3/8" = 1'-0" NEW 16X16 STONE TILE (SN-3) FLOOR TO CEILING THROUGHOUT BOTH RESTROOMS, BUTT JOIN W/ MIN. GROUT TO MATCH SCALE: SOUTH MEN'S WALL 7 3/8" = 1'-0" SCALE: WEST MEN'S WALL 8 3/8" = 1'-0" SCALE: LAV TOP 10 1" = 1'-0" SCALE: LOW WALL TILE NOSE 9 1-1/2" = 1'-0" SECTION PLAN 1X3 TUBE STEEL PWDR. COATED SATIN SILVER, BELOW STONE LAV TOP, SADDLE AS REQD. TO ATTACH TO STONE 4X4X1/4" PLATE WELDED TO 1X3 BRACKET AND ANCHORED INTO 2X BLOCKING BETWEEN STUDS IN WALL, ADD 2X BLOCKING BELOW HORIZONTAL BLOCKING FOR VERTICAL SUPPORT NEW STONE TILE EXISTING STUDS EXISTING GYP. BD. BACK WALL GUEST SIDE 633 4" 21 2" 2 1 2" 24" 21 2" DEMO EXISTING MIXERS, INSTALL NEW FBO MIXERS AND SOAP DISPENSERS W/ NEW LAV. USING EXISTING PLUMBING NEW 2-5/8" STONE LAV TOP, FBO, INSTALLED BGC OVERMOUNT SINKS LOCATED AND INSTALLED BY STONE VENDOR, DIMENSIONS PROVIDED BGC PRIOR TO FABRICATION FULL CAP TILE, FOLLOW VERTICAL GROUT PATTERN, HAND EASE EDGES EXISTING OR NEW P.T. AS REQUIRED FRAMING EXISTING GYP. BD. FULL CAP TILE, FOLLOW HORIZONTAL GROUT PATTERN, HAND EASE EDGES EXISTING OR NEW P.T. AS REQUIRED FRAMING EXISTING GYP. BD. NEW STONE TILE NEW STONE TILE DEMO EXISTING MIXERS, INSTALL NEW FBO MIXERS AND SOAP DISPENSERS W/ NEW LAV. USING EXISTING PLUMBING SN-3 SN-3 SN-3 SN-3 SN-3 SN-3 NEW FULL-LITE MAHOGANY DOOR W/ PPG 'RAIN GLASS' PATTERN. REUSE EXISTING HARDWARE DEMO EXISTING MIRRORS. INSTALL NEW FBO MIRRORS DEMO EXIST. SCONCES. RELOCATE PWR. TO CEILING ABOVE LAV TOP FOR (2) NEW 'M' FIXTURES DEMO EXISTING MIXERS, INSTALL NEW FBO MIXERS AND SOAP DISPENSERS W/ NEW LAV. USING EXISTING PLUMBING 9 A8.3 9 A8.3 REMOVE MIRROR. RECUT AND RELOCATE. ALL RESTROOM HDWE. INCL.: GRAB BARS, DISPENSERS TO BE REMOVED AND REINSTALLED AS REQD. FOR CONSISTENT INSTALLATION OF NEW STONE TILE, TYP. @ BOTH RESTROOMS DEMO EXISTING WALL TILE, INCLUDING BASE, REPAIR SUBSTRATE AS REQD. TO ACCEPT NEW STONE TILE SPEC. NEW S.S. PARTITIONS TO MATCH EXISTING SIZES AND LOCATIONS TYP. OF BOTH RESTROOMS GENERAL NOTES: 1. G.C. TO FIELD VERIFY/CORRECT FAN AND VENTING AT BOTH RESTROOMS TO ENSURE MAXIMUM AMOUNT OF AIR FLOW. EXISTING PAPER TOWEL DISP. TO BE REMOVED AND REINSTALLED FOLLOWING WALL TILE INSTALLATION FULL HEIGHT TILE ROWS TO BEGIN @ CEILING, REMAINING 6" +/- CUT @ BOTTOM ROW, TYP. @ ALL WALLS BOTH RESTROOMS REMOVE MIRROR REMOVE EXISTING FIXTURE FULL HEIGHT TILE ROWS TO BEGIN @ CEILING, REMAINING 6" +/- CUT @ BOTTOM ROW, TYP. @ ALL WALLS BOTH RESTROOMS PT-2 PT-2 PT-2 PT-2 PT-2 PT-2 ALL PLUMBING INCLUDING ESCUTCHEONS TO BE SHINY CHROME. DEMO EXISTING GRANITE LAV. REPAIR SURFACES AS REQUIRED TO ACCEPT NEW FINISHES. ADJUST DRAIN TO 25" AFF 25" ALL RESTROOM HDWE. INCL.: GRAB BARS, DISPENSERS TO BE REMOVED AND REINSTALLED AS REQD. FOR CONSISTENT INSTALLATION OF NEW STONE TILE, TYP. @ BOTH RESTROOMS ALL PLUMBING INCLUDING ESCUTCHEONS TO BE SHINY CHROME. DEMO EXISTING GRANITE LAV. REPAIR SURFACES AS REQUIRED TO ACCEPT NEW FINISHES. NEW S.S. PARTITIONS TO MATCH EXISTING SIZES AND LOCATIONS TYP. OF BOTH RESTROOMS EXISTING PAPER TOWEL DISP. TO BE REMOVED AND REINSTALLED FOLLOWING WALL TILE INSTALLATION NEW S.S. PARTITIONS TO MATCH EXISTING SIZES AND LOCATIONS TYP. OF BOTH RESTROOMS FULL HEIGHT TILE ROWS TO BEGIN @ CEILING, REMAINING 6" +/- CUT @ BOTTOM ROW, TYP. @ ALL WALLS BOTH RESTROOMS DEMO EXISTING WALL TILE, INCLUDING BASE, REPAIR SUBSTRATE AS REQD. TO ACCEPT NEW STONE TILE SPEC. SN-3 PT-2 34" MAX. 27" MIN. ALL RESTROOM HDWE. INCL.: GRAB BARS, DISPENSERS TO BE REMOVED AND REINSTALLED AS REQD. FOR CONSISTENT INSTALLATION OF NEW STONE TILE, TYP. @ BOTH RESTROOMS 34" MAX. 27" MIN. 25" NEW FULL-LITE MAHOGANY DOOR W/ PPG 'RAIN GLASS' PATTERN. REUSE EXISTING HARDWARE SCALE: TOILET ROOMS PLAN 11 3/8" = 1'-0" 8 - A8.3 5 7 6 4 - A8.3 1 3 2 RECUT MIRROR AND RELOCATE, 36"x60" MOUNT OVER STONE TILE REMOVE MIRROR 26" RECUT MIRROR, MOUNT ON NEW WALL TILE (SN-3) LOW WALL TO BE DEMO'D AND REBUILT W/ P.T. REMOVE PANEL NOTE: "0" GROUT JOINTS - FILL VOIDS W/ THIN GROUT TO MATCH COLOR. COVE GROUT JOINT, TYPICAL NOTE: "0" GROUT JOINTS - FILL VOIDS W/ THIN GROUT TO MATCH COLOR. COVE GROUT JOINT, TYPICAL LOW WALL TO BE DEMO'D AND REBUILT W/ P.T. REMOVE PANEL NOTE: GC TO LOCATE REBUILT LOW WALL IN BOTH RESTROOMS TO ACCOMMODATE DIMENSIONS AS SHOWN PER NEW LAV TOP.