Loading...
HomeMy WebLinkAboutI4797720.b11112048(7).PDFb11112048 ProBuild(Mooresville). My license renewal date for the state of Indiana is July 31, 2012. Pages or sheets covered by this seal: The truss drawing(s) referenced below have been prepared by DrJ Consulting, LLC under my direct supervision based on the parameters provided by The seal on these Truss Design Drawings indicates acceptance of professional engineering responsibility for the design assumptions as defined on this truss design drawing, solely for the truss component(s) depicted. The design assumptions, loading conditions, suitability and use of this component for any particular building is the responsibility of the building designer or owner of the trusses, per ANSI/ITPI 1. The responsibilities and duties of the truss designer, truss design engineer and truss manufacturer shall be in accord with the latest edition of ANSI/TPI 1 Chapter 2 unless otherwise defined by a contract agreed upon by the parties involved. Re: I4797722thruI4797786 MiTek 20/20 7.2 Important Notice: The accuracy of the Truss Design Drawings relies upon: 1. Accurate metal plate connector design values as published by MiTek. 2. Accurate design values for solid sawn lumber. Design values (E, Emin, Fb, Fc, Fcperp, Ft, and Fv) for solid sawn lumber and approved, grade stamped, finger jointed lumber shall be as defined by the grade stamp prior to cross cutting and in accordance with the published values of lumber rules writing agencies approved by the Board of Review of the American Lumber Standards Committee in accordance with the latest edition of ANSI/TPI 1 Section 6.3. Ryan J. Dexter, P.E. DrJ Consulting, LLC 6300 Enterprise Lane Madison, Wisconsin, 53719 June 24,2011 Job B11112048 Truss CG01 Truss Type Diagonal Hip Girder Qty 3 Ply 1 Job Reference (optional) I4797722 PROBUILD, MOORESVILLE, IN 46158 7.250 s Apr 21 2011 MiTek Industries, Inc. Thu Jun 23 18:34:30 2011 Page 1 ID:IvJazOcGaW7oP7FTFIz4YgzLu67-vx6DoB4HgUQT9eW_hD?Qx5scCvSItof4UR?zFMz3Jft Scale = 1:14.4 W1 T1 W3 B1 W2 1 2 3 5 4 5x6 1.5x4 3x4 2-2-7 2-2-7 2-2-15 0-0-8 10-1-2 10-1-2 -2-1-7 2-1-7 2-2-15 2-2-15 10-1-2 10-1-2 0-8-7 2-0-9 7.20 12 Plate Offsets (X,Y): [5:Edge,0-4-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING Plates Increase Lumber Increase Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 Job B11112048 Truss CG02 Truss Type Diagonal Hip Girder Qty 2 Ply 1 Job Reference (optional) I4797723 PROBUILD, MOORESVILLE, IN 46158 7.250 s Apr 21 2011 MiTek Industries, Inc. Thu Jun 23 18:34:30 2011 Page 1 ID:IvJazOcGaW7oP7FTFIz4YgzLu67-vx6DoB4HgUQT9eW_hD?Qx5scCvRstoy4UR?zFMz3Jft Scale = 1:20.4 W1 T1 W2 B1 1 2 3 5 4 6 7 8 9 3x6 1.5x4 1.5x4 1-0-14 1-0-6 1-11-0 0-10-2 4-4-10 2-5-10 10-1-2 10-1-2 -2-1-7 2-1-7 1-0-14 1-0-14 1-11-0 0-10-2 4-4-10 2-5-10 10-1-2 10-1-2 0-8-7 3-4-0 7.20 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 Job B11112048 Truss CP Truss Type GABLE Qty 1 Ply 1 Job Reference (optional) I4797724 PROBUILD, MOORESVILLE, IN 46158 7.250 s Apr 21 2011 MiTek Industries, Inc. Thu Jun 23 18:34:31 2011 Page 1 ID:IvJazOcGaW7oP7FTFIz4YgzLu67-N8gc0X4wRoZKno5AFxWfTIProInucFTEj5kXnoz3Jfs Scale = 1:28.4 T1 T1 T2 B1 W1 ST1 ST1 ST1 W1 1 2 3 7 8 9 4 5 6 14 13 12 11 10 4x6 4x6 3x4 1.5x4 1.5x4 1.5x4 3x4 1.5x4 1.5x4 1.5x4 1.5x4 1.5x4 2-9-4 2-9-4 13-2-15 10-5-11 16-0-3 2-9-4 22-6-13 2-8-0 2-8-0 13-4-3 10-8-3 16-0-3 2-8-0 22-6-13 0-4-6 2-0-0 0-1-8 0-4-6 0-1-8 1-10-8 9.00 12 Plate Offsets (X,Y): [3:0-4-0,0-2-0], [7:0-4-0,0-2-0] LOADING (psf) TCLL TCDL BCLL BASE TRUSS Refer to actual truss design drawing for additional base truss information. PIGGYBACK TRUSS Refer to actual truss design drawing for additional piggyback truss information. For wind speed 101 - 146 MPH and mean roof height up to 60 feet, attach MiTek 3x8 20 GA. Nail-On plates to each face of truss at 72"o.c. w/ 8d x 1 1/2" common wire nails (.131"x1.5"). Do not use holes within 1/2"of the edge of member. Apply 4 nails from each face in each member. Nails should be staggered and equally divided between front and back. 2 x ___ x 6’-0" SIZE TO MATCH TOP CHORD OF PIGGYBACK TRUSS. ATTACHED TO ONE FACE OF TOP CHORD WITH 2 R0WS OF 10d (0.131" X 3") NAILS SPACED 6" O.C. 1) VERTICAL WEBS OF PIGGYBACK AND BASE TRUSS MUST MATCH IN SIZE, GRADE, AND MUST LINE UP AS SHOWN IN DETAIL. 2) VERTICAL WEBS OF PIGGYBACK MUST RUN THROUGH BOTTOM CHORD SO THAT THERE IS FULL WOOD TO WOOD CONTACT BETWEEN WEB OF PIGGYBACK AND THE TOP CHORD OF THE BASE TRUSS. 3) CONCENTRATED LOAD MUST BE APPLIED TO BOTH THE PIGGYBACK AND THE BASE TRUSS. 4) ATTACH 2 x ___ x 6’-0" SCAB TO EACH FACE OF TRUSS ASSEMBLY WITH 2 ROWS OF 10d (0.131" X 3") NAILS SPACED 6" O.C. FROM EACH FACE. (SIZE AND GRADE TO MATCH VERTICAL WEBS OF PIGGYBACK AND BASE TRUSS.) (MINIMUM 2X4) 5) THIS CONNECTION IS ONLY VALID FOR A MAXIMUM CONCENTRATED LOAD OF 4000 LBS (@1.15). REVIEW BY A QUALIFIED ENGINEER IS REQUIRED FOR LOADS GREATER THAN 4000 LBS. 6) FOR PIGGYBACK TRUSSES CARRYING GIRDER LOADS, NUMBER OF PLYS OF PIGGYBACK TRUSS TO MATCH BASE TRUSS. STANDARD PIGGYBACK TRUSS CONNECTION DETAIL VERTICAL WEB TO EXTEND THROUGH BOTTOM CHORD OF PIGGYBACK ST-PIGGY SPACE PURLINS ACCORDING TO THE MAXIMUM SPACING ON THE TOP CHORD OF THE BASE TRUSS (SPACING NOT TO EXCEED 24" O.C.).A PURLIN TO BE LOCATED AT EACH BASE TRUSS JOINT. ATTACH EACH PURLIN TO TOP CHORD OF BASE TRUSS WITH 2 - 16d (0.131" X 3.5") NAILS. ATTACH PIGGYBACK TRUSS TO EACH PURLIN WITH 2 - 16d (0.131" X 3.5") NAILS TOENAILED. FOR PIGGY BACK TRUSSES WITH SPANS < 12’ SCAB MAY BE OMMITED PROVIDED THAT: ROOF SHEATHING TO BE CONTINUOUS OVER JOINT (SHEATHING TO OVERLAP MINIMUM 12" OVER JOINT) IF NO GAP EXISTS BETWEEN CAP TRUSS AND BASE TRUSS: FOR LARGE CONCENTRATED LOADS APPLIED TO CAP TRUSS REQUIRING A VERTICAL WEB: REPLACE TOE NAILING OF CAP TRUSS TO PURLINS WITH GUSSETS AS SHOWN, AND APPLY PURLINS TO LOWER EDGE OF BASE Job B11112048 Truss CP1 Truss Type HIP CAP Qty 2 Ply 1 Job Reference (optional) I4797725 PROBUILD, MOORESVILLE, IN 46158 7.250 s Apr 21 2011 MiTek Industries, Inc. Thu Jun 23 18:34:32 2011 Page 1 ID:IvJazOcGaW7oP7FTFIz4YgzLu67-rKE_Dt5YC6hBPyfNpe2u0Wx_ri6wLhuNxlU4KFz3Jfr Scale = 1:28.4 T1 T1 T2 B1 W1 W1 1 2 3 4 5 6 8 7 4x6 4x6 3x4 1.5x4 1.5x4 3x4 5-5-4 5-5-4 10-6-15 5-1-11 16-0-3 5-5-4 22-6-13 5-4-0 5-4-0 10-8-3 5-4-3 16-0-3 5-4-0 22-6-13 0-4-6 4-0-0 0-1-8 0-4-6 0-1-8 3-10-8 9.00 12 Plate Offsets (X,Y): [3:0-3-8,0-2-0], [4:0-3-8,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING Plates Increase Job B11112048 Truss CP2 Truss Type GABLE Qty 6 Ply 1 Job Reference (optional) I4797726 PROBUILD, MOORESVILLE, IN 46158 7.250 s Apr 21 2011 MiTek Industries, Inc. Thu Jun 23 18:34:33 2011 Page 1 ID:IvJazOcGaW7oP7FTFIz4YgzLu67-JWoMQD6AzPp206EZNMZ7ZjUBc6SH47iXAPDeshz3Jfq Scale = 1:30.9 T1 T1 B1 W1 ST1 ST1 1 2 3 4 5 67 10 9 8 4x6 3x4 1.5x4 1.5x4 3x4 1.5x4 1.5x4 1.5x4 8-0-2 8-0-2 16-0-3 8-0-1 22-6-13 8-0-2 8-0-2 16-0-3 8-0-1 22-6-13 0-4-6 6-0-1 0-1-8 0-4-6 0-1-8 9.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING Plates Increase Lumber Increase 3x4 = Trusses @ 24" o.c. End Wall Roof Sheathing 1’-3" Max. 12 Varies to Common Truss A A * * - Diagonal Bracing * Refer to Section A-A 24" Max Vertical Stud SECTION A-A 2x6 Stud or 2x4 No.2 of better 2x4 Stud DIAGONAL BRACE Typical Horizontal Brace Nailed To 2x_ Verticals w/(4)-10d Common Nails DIAGONAL BRACE 4’-0" O.C. MAX MAXIMUM WIND SPEED = 90 MPH MAX MEAN ROOF HEIGHT = 30 FEET CATEGORY II BUILDING EXPOSURE B or C ASCE 7-98, ASCE 7-02, ASCE 7-05 DURATION OF LOAD INCREASE : 1.60 (4) - 8d NAILS MINIMUM, PLYWOOD SHEATHING TO 2x4 STD SPF BLOCK HORIZONTAL BRACE (SEE SECTION A-A) (2) - 10d (2) - 10d NAILS June 16, 2011 Standard Gable End Detail ST-GE90-2x3-001 Page 1 OF 1 SEE INDIVIDUAL TRUSS DESIGN DRAWINGS FOR DESIGN CRITERIA Minimum Stud Size Species and Grade Stud Spacing Without Brace 1x4 L-Brace 2x4 L-Brace Maximum Stud Length 2x3 SPF No.3 12" O.C. 4-7-5 8-8-6 16" O.C. 4-2-4 7-6-6 24" O.C. 3-7-14 6-1-13 NOTE: 1. MINIMUM GRADE OF #2 MATERIAL IN THE TOP AND BOTTOM CHORDS. Standard Gable End Detail SHEET 2 Trusses @ 24" o.c. Roof Sheathing 1’-3" Max. 2x6 DIAGONAL BRACE SPACED 48" O.C. ATTACHED TO VERTICAL WITH (4) -16d COMMON WIRE NAILS AND ATTACHED TO BLOCKING WITH (5) - 10d COMMONS. PROVIDE 2x4 BLOCKING BETWEEN THE TRUSSES SUPPORTING THE BRACE AND THE TWO TRUSSES ON EITHER SIDE AS NOTED. TOENAIL BLOCKING TO TRUSSES WITH (2) - 10d NAILS AT EACH END. ATTACH DIAGONAL BRACE TO BLOCKING WITH (5) - 10d COMMON WIRE NAILS. End Wall Diag. Brace at 1/3 points if needed 2X 4 PURLIN FASTENED TO FOUR TRUSSES WITH TWO 16d NAILS EACH. FASTEN PURLIN TO BLOCKING W/ TWO 16d NAILS (MIN) CEILING SHEATHING IT IS THE RESPONSIBILITY OF THE BLDG DESIGNER OR THE PROJECT ENGINEER/ARCHTECT TO DESIGN THE CEILING DIAPHRAGM AND ITS ATTACHMENT TO THE TRUSSES TO RESIST ALL OUT OF PLANE LOADS THAT MAY RESULT FROM THE BRACING OF THE GABLE ENDS NAIL DIAGONAL BRACE TO PURLIN WITH TWO 16d NAILS ALTERNATE DIAGONAL BRACING TO THE BOTTOM CHORD BRACING REQUIREMENTS FOR STRUCTURAL GABLE TRUSSES STRUCTURAL GABLE TRUSSES MAY BE BRACED AS NOTED: METHOD 1 : ATTACH A MATCHING GABLE TRUSS TO THE INSIDE FACE OF THE STRUCTURAL GABLE AND FASTEN PER THE FOLLOWING NAILING SCHEDULE. METHOD 2 : ATTACH 2X _ SCABS TO THE FACE OF EACH VERTICAL MEMBER ON THE STRUCTURAL GABLE PER THE FOLLOWING NAILING SCHEDULE. SCABS ARE TO BE OF THE SAME SIZE, GRADE AND SPECIES AS THE TRUSS VERTICALS NAILING SCHEDULE: - FOR WIND SPEEDS 120 MPH OR LESS, NAIL ALL MEMBERS WITH ONE ROW OF 10d (.131" X 3") NAILS SPACED 6" O.C. - FOR WIND SPEEDS GREATER 120 MPH NAIL ALL MEMBERS WITH TWO ROWS OF 10d (.131" X 3") NAILS SPACED 6" O.C. (2X 4 STUDS MINIMUM) STRUCTURAL GABLE TRUSS SCAB ALONG VERTICAL MAXIMUM STUD LENGTHS ARE LISTED ON PAGE 1. ALL BRACING METHODS SHOWN ON PAGE 1 ARE VALID AND ARE TO BE FASTENED TO THE SCABS OR VERTICAL STUDS OF THE STANDARD GABLE TRUSS ON THE INTERIOR SIDE OF THE STRUCTURE. INLAYED STUD NOTE : THIS DETAIL IS TO BE USED ONLY FOR STRUCTURAL GABLES WITH INLAYED STUDS. TRUSSES WITHOUT INLAYED STUDS ARE NOT ADDRESSED HERE. STRUCTURAL Job B11112048 Truss CP3 Truss Type GABLE Qty 1 Ply 1 Job Reference (optional) I4797727 PROBUILD, MOORESVILLE, IN 46158 7.250 s Apr 21 2011 MiTek Industries, Inc. Thu Jun 23 18:34:34 2011 Page 1 ID:IvJazOcGaW7oP7FTFIz4YgzLu67-njMkeZ7okjxueGplw34M5x1M1WobpcCgP3zBO7z3Jfp Scale = 1:28.4 T1 T1 T2 B1 W1 ST1 ST1 ST1 W1 1 2 3 7 8 9 4 5 6 14 13 12 11 10 4x6 4x6 3x4 1.5x4 1.5x4 1.5x4 3x4 1.5x4 1.5x4 1.5x4 1.5x4 1.5x4 2-9-4 2-9-4 13-2-15 10-5-11 16-0-3 2-9-4 22-6-13 2-8-0 2-8-0 13-4-3 10-8-3 16-0-3 2-8-0 22-6-13 0-4-6 2-0-0 0-1-8 0-4-6 0-1-8 1-10-8 9.00 12 Plate Offsets (X,Y): [3:0-4-0,0-2-0], [7:0-4-0,0-2-0] LOADING (psf) TCLL TCDL BCLL Job B11112048 Truss CP4 Truss Type PIGGYBACK Qty 6 Ply 1 Job Reference (optional) I4797728 PROBUILD, MOORESVILLE, IN 46158 7.250 s Apr 21 2011 MiTek Industries, Inc. Thu Jun 23 18:34:34 2011 Page 1 ID:IvJazOcGaW7oP7FTFIz4YgzLu67-njMkeZ7okjxueGplw34M5x1N4WlmpcxgP3zBO7z3Jfp Scale = 1:13.9 T1 T1 B1 1 2 3 4 5 3x4 2x4 2x4 6-0-3 6-0-3 22-6-13 3-0-2 3-0-2 6-0-3 3-0-1 22-6-13 0-4-6 2-3-1 0-1-8 0-4-6 0-1-8 9.00 12 Plate Offsets (X,Y): [3:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING Plates Increase Lumber Increase Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI TC Job B11112048 Truss CP5 Truss Type HIP CAP Qty 1 Ply 1 Job Reference (optional) I4797729 PROBUILD, MOORESVILLE, IN 46158 7.250 s Apr 21 2011 MiTek Industries, Inc. Thu Jun 23 18:34:35 2011 Page 1 ID:IvJazOcGaW7oP7FTFIz4YgzLu67-Fvw6rv8QV13lGPOyUmbbe8ZZDw9bY3?pejikwZz3Jfo Scale = 1:12.5 T1 T1 T2 B1 W1 W1 1 2 3 4 5 6 8 7 4x6 4x6 2x4 1.5x4 1.5x4 2x4 2-9-4 2-9-4 3-2-15 0-5-11 6-0-3 2-9-4 22-6-13 2-8-0 2-8-0 3-4-3 0-8-3 6-0-3 2-8-0 22-6-13 0-4-6 2-0-0 0-1-8 0-4-6 0-1-8 1-10-8 9.00 12 Plate Offsets (X,Y): [3:0-4-0,0-2-0], [4:0-4-0,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING Plates Increase Job B11112048 Truss GE01 Truss Type GABLE Qty 1 Ply 1 Job Reference (optional) I4797730 PROBUILD, MOORESVILLE, IN 46158 7.250 s Apr 21 2011 MiTek Industries, Inc. Thu Jun 23 18:34:37 2011 Page 1 ID:IvJazOcGaW7oP7FTFIz4YgzLu67-CI1tGa9g1eJTVjYKcBd3jZfurjru0x5651Br?Sz3Jfm Scale = 1:62.0 T2 T2 B1 ST8 ST7 ST6 ST5 ST4 ST3 ST2 ST1 HW1 HW1 ST7 ST6 ST5 ST4 ST3 ST2 T1 ST1 T1 B2 O3 O2 O1 O4 O5 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Job B11112048 Truss GE03 Truss Type GABLE Qty 1 Ply 1 Job Reference (optional) I4797731 PROBUILD, MOORESVILLE, IN 46158 7.250 s Apr 21 2011 MiTek Industries, Inc. Thu Jun 23 18:34:38 2011 Page 1 ID:IvJazOcGaW7oP7FTFIz4YgzLu67-gUbFUwAJoyRK7t7X9v9IGnB3b7BElQFGKhxPXuz3Jfl Scale: 3/8"=1’ T1 T1 B1 ST3 ST2 HW1 HW1 ST1 ST2 ST1 1 2 3 4 5 6 7 8 9 14 13 12 11 10 4x6 3x6 1.5x4 1.5x4 3x6 1.5x4 1.5x4 1.5x4 1.5x4 1.5x4 1.5x4 1.5x4 9-4-0 9-4-0 10-1-2 -1-3-4 1-3-4 4-8-0 4-8-0 9-4-0 4-8-0 10-7-4 1-3-4 10-1-2 0-8-7 5-4-7 0-8-7 12.00 12 LOADING (psf) TCLL 3x4 = Trusses @ 24" o.c. End Wall Roof Sheathing 1’-3" Max. 12 Varies to Common Truss A A * * - Diagonal Bracing * Refer to Section A-A 24" Max Vertical Stud SECTION A-A 2x6 Stud or 2x4 No.2 of better 2x4 Stud DIAGONAL BRACE Typical Horizontal Brace Nailed To 2x_ Verticals w/(4)-10d Common Nails DIAGONAL BRACE 4’-0" O.C. MAX MAXIMUM WIND SPEED = 90 MPH MAX MEAN ROOF HEIGHT = 30 FEET CATEGORY II BUILDING EXPOSURE B or C ASCE 7-98, ASCE 7-02, ASCE 7-05 DURATION OF LOAD INCREASE : 1.60 (4) - 8d NAILS MINIMUM, PLYWOOD SHEATHING TO 2x4 STD SPF BLOCK HORIZONTAL BRACE (SEE SECTION A-A) (2) - 10d (2) - 10d NAILS June 16, 2011 Standard Gable End Detail ST-GE90-2x3-001 Page 1 OF 1 SEE INDIVIDUAL TRUSS DESIGN DRAWINGS FOR DESIGN CRITERIA Minimum Stud Size Species and Grade Stud Spacing Without Brace 1x4 L-Brace 2x4 L-Brace Maximum Stud Length 2x3 SPF No.3 12" O.C. 4-7-5 8-8-6 16" O.C. 4-2-4 7-6-6 24" O.C. 3-7-14 6-1-13 NOTE: 1. MINIMUM GRADE OF #2 MATERIAL IN THE TOP AND BOTTOM CHORDS. Job B11112048 Truss GR01 Truss Type Hip Truss Qty 1 Ply 1 Job Reference (optional) I4797732 PROBUILD, MOORESVILLE, IN 46158 7.250 s Apr 21 2011 MiTek Industries, Inc. Thu Jun 23 18:34:40 2011 Page 1 ID:IvJazOcGaW7oP7FTFIz4YgzLu67-csj?ucBZKZh2MBHvHKBmLCGD?xh2D58Yn?QVcnz3Jfj Scale = 1:70.7 T1 T2 T1 B1 W1 W2 W3 W4 W5 W4 W5 W4 W5 W4 W5 W4 W3 W2 W1 T3 B2 B1 HW1 HW2 1 2 3 4 5 6 7 8 9 10 11 12 13 23 22 21 20 19 18 17 24 25 26 27 16 15 14 28 29 30 31 32 33 34 35 3x6 6x10 6x8 3x6 2x4 4x6 8x8 5x10 MT18H 1.5x4 3x8 2x4 1.5x4 5x8 4x6 6x6 5x10 MT18H 4x6 3x6 2x4 6x8 6x10 2-4-3 2-4-3 4-4-3 2-0-0 4-5-3 0-1-0 6-4-3 Job B11112048 Truss GR01 Truss Type Hip Truss Qty 1 Ply 1 Job Reference (optional) I4797732 PROBUILD, MOORESVILLE, IN 46158 7.250 s Apr 21 2011 MiTek Industries, Inc. Thu Jun 23 18:34:40 2011 Page 2 ID:IvJazOcGaW7oP7FTFIz4YgzLu67-csj?ucBZKZh2MBHvHKBmLCGD?xh2D58Yn?QVcnz3Jfj LOAD CASE(S) Standard 1) Regular: Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-4=-60, 4-10=-60, 10-13=-60, 2-12=-20 Concentrated Loads (lb) Vert: 23=-203(B) 22=-202(B) 21=-202(B) 15=-202(B) 14=-203(B) 17=-202(B) 24=-146(B) 25=-203(B) 26=-202(B) 27=-202(B) 28=-202(B) 29=-202(B) 30=-202(B) 31=-202(B) 32=-202(B) 33=-202(B) 34=-203(B) 35=-146(B) WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/ diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage, delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from SBCA at www.sbcindustry.com. Job B11112048 Truss GR02 Truss Type Half Hip Truss Qty 1 Ply 2 Job Reference (optional) I4797733 PROBUILD, MOORESVILLE, IN 46158 7.250 s Apr 21 2011 MiTek Industries, Inc. Thu Jun 23 18:34:42 2011 Page 1 ID:IvJazOcGaW7oP7FTFIz4YgzLu67-YFrmJIDpsAxmcUQIOlDEQdMaYkLkh0grFJvcgfz3Jfh Scale = 1:87.5 T1 T2 W5 B1 W1 W2 W3 W4 W5 W4 W5 W4 W5 W4 W5 W4 W5 W4 W5 W4 W5 W4 T2 T3 B2 B3 B4 1 2 3 4 5 6 7 8 9 10 11 12 13 14 27 26 25 24 23 22 21 20 19 18 17 16 15 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 3x6 6x6 3x4 5x8 5x6 3x6 2x4 4x6 5x8 5x6 2x4 3x8 2x4 4x8 2x4 2x4 3x8 2x4 5x8 2x4 5x8 2x4 8x8 3x6 5x6 5x6 2-4-3 2-4-3 4-4-3 2-0-0 4-5-3 0-1-0 6-4-3 1-11-0 8-3-7 1-11-4 Job B11112048 Truss GR02 Truss Type Half Hip Truss Qty 1 Ply 2 Job Reference (optional) I4797733 PROBUILD, MOORESVILLE, IN 46158 7.250 s Apr 21 2011 MiTek Industries, Inc. Thu Jun 23 18:34:42 2011 Page 2 ID:IvJazOcGaW7oP7FTFIz4YgzLu67-YFrmJIDpsAxmcUQIOlDEQdMaYkLkh0grFJvcgfz3Jfh NOTES 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 167 lb down and 20 lb up at 2-4-3, 203 lb down and 50 lb up at 4-4-3, 203 lb down and 69 lb up at 6-4-3, 202 lb down and 90 lb up at 8-4-3, 202 lb down and 90 lb up at 10-4-3, 202 lb down and 90 lb up at 12-4-3, 202 lb down and 90 lb up at 14-4-3, 202 lb down and 90 lb up at 16-4-3, 202 lb down and 90 lb up at 18-4-3, 202 lb down and 90 lb up at 20-4-3, 202 lb down and 90 lb up at 22-4-3, 202 lb down and 90 lb up at 24-4-3, 202 lb down and 90 lb up at 26-4-3, 202 lb down and 90 lb up at 28-4-3, 202 lb down and 90 lb up at 30-4-3, 202 lb down and 90 lb up at 32-4-3, 202 lb down and 90 lb up at 34-4-3, 202 lb down and 90 lb up at 36-4-3, 202 lb down and 90 lb up at 38-4-3, 202 lb down and 90 lb up at 40-4-3, 202 lb down and 90 lb up at 42-4-3, 202 lb down and 90 lb up at 44-4-3, and 202 lb down and 90 lb up at 46-4-3, and 202 lb down and 90 lb up at 47-4-3 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 10) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required. LOAD CASE(S) Standard 1) Regular: Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-4=-60, 4-14=-60, 2-15=-20 Concentrated Loads (lb) Vert: 27=-203(F) 26=-202(F) 23=-202(F) 21=-202(F) 17=-202(F) 19=-202(F) 28=-146(F) 29=-203(F) 30=-202(F) 31=-202(F) 32=-202(F) 33=-202(F) 34=-202(F) 35=-202(F) 36=-202(F) 37=-202(F) 38=-202(F) 39=-202(F) 40=-202(F) 41=-202(F) 42=-202(F) 43=-202(F) 44=-202(F) 45=-202(F) WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/ diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage, delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from SBCA at www.sbcindustry.com. Job B11112048 Truss GR03 Truss Type Half Hip Truss Qty 3 Ply 1 Job Reference (optional) I4797734 PROBUILD, MOORESVILLE, IN 46158 7.250 s Apr 21 2011 MiTek Industries, Inc. Thu Jun 23 18:34:43 2011 Page 1 ID:IvJazOcGaW7oP7FTFIz4YgzLu67-0RP8XeERcU3dDe?UySkTzquts8s_Qgr?Tze9D6z3Jfg Scale = 1:15.8 T1 T2 W1 B1 W1 W2 HW1 1 2 3 4 6 5 7 8 9 10 4x6 1.5x4 3x4 4x6 3x8 2x4 1-4-12 1-4-12 5-10-12 4-6-0 10-1-2 10-1-2 -1-3-4 1-3-4 1-4-12 1-4-12 3-5-8 2-0-12 5-5-8 2-0-0 5-10-12 0-5-4 10-1-2 10-1-2 0-8-7 2-1-3 12.00 12 Plate Offsets (X,Y): [2:0-1-0,0-4-3], [2:0-0-0,0-0-8], [3:0-4-8,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 Job B11112048 Truss GR04 Truss Type Hip Truss Qty 1 Ply 1 Job Reference (optional) I4797735 PROBUILD, MOORESVILLE, IN 46158 7.250 s Apr 21 2011 MiTek Industries, Inc. Thu Jun 23 18:34:44 2011 Page 1 ID:IvJazOcGaW7oP7FTFIz4YgzLu67-VezWk_F3NoBUroagW9FiV2R2FYAg94C8idOjlYz3Jff Scale: 3/8"=1’ T1 T2 T1 B1 W1 W2 W1 W2 W1 HW1 HW1 1 2 3 4 5 6 7 10 9 8 11 12 13 14 15 4x6 4x6 4x8 4x8 2x4 3x8 1.5x4 2x4 2-8-3 2-8-3 8-0-0 5-3-13 13-3-1 5-3-1 13-3-13 0-0-12 16-0-0 2-8-3 10-1-2 10-1-2 -1-3-4 1-3-4 2-8-3 2-8-3 8-0-0 5-3-13 13-3-13 5-3-13 16-0-0 2-8-3 17-3-4 1-3-4 Job B11112048 Truss J01 Truss Type Jack-Open Truss Qty 9 Ply 1 Job Reference (optional) I4797736 PROBUILD, MOORESVILLE, IN 46158 7.250 s Apr 21 2011 MiTek Industries, Inc. Thu Jun 23 18:34:44 2011 Page 1 ID:IvJazOcGaW7oP7FTFIz4YgzLu67-VezWk_F3NoBUroagW9FiV2R4PYEi98Q8idOjlYz3Jff Scale = 1:14.8 T1 B1 1 2 3 4 2x4 2-2-11 2-2-11 2-3-7 0-0-12 10-1-2 11-8-13 10-1-2 -1-3-4 1-3-4 2-3-7 2-3-7 10-1-2 11-8-13 10-1-2 0-4-10 2-1-3 1-7-11 9.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING Plates Increase Lumber Increase Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI TC BC Job B11112048 Truss J02 Truss Type Jack-Open Truss Qty 1 Ply 1 Job Reference (optional) I4797737 PROBUILD, MOORESVILLE, IN 46158 7.250 s Apr 21 2011 MiTek Industries, Inc. Thu Jun 23 18:34:45 2011 Page 1 ID:IvJazOcGaW7oP7FTFIz4YgzLu67-zqWuyJFi85JLTy9t4tnx2F_GkyaMubgIxH7GH_z3Jfe Scale = 1:11.6 T1 B1 1 2 4 5 3 6 2x4 1-4-12 1-4-12 10-1-2 11-0-1 10-1-2 -1-3-4 1-3-4 1-4-12 1-4-12 10-1-2 11-0-1 10-1-2 0-4-10 1-5-3 1-4-7 0-10-15 9.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING Plates Increase Lumber Increase Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI TC Job B11112048 Truss J03 Truss Type Jack-Open Truss Qty 1 Ply 1 Job Reference (optional) I4797738 PROBUILD, MOORESVILLE, IN 46158 7.250 s Apr 21 2011 MiTek Industries, Inc. Thu Jun 23 18:34:45 2011 Page 1 ID:IvJazOcGaW7oP7FTFIz4YgzLu67-zqWuyJFi85JLTy9t4tnx2F_GpyaMubgIxH7GH_z3Jfe Scale = 1:14.2 T1 B1 HW1 1 2 4 3 3x6 5 1-2-6 1-2-6 10-1-2 11-4-15 10-1-2 -1-3-4 1-3-4 1-2-6 1-2-6 10-1-2 11-4-15 10-1-2 0-8-7 1-10-13 12.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING Plates Increase Lumber Increase Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI TC BC WB (Matrix) Job B11112048 Truss J04 Truss Type Jack-Open Truss Qty 1 Ply 1 Job Reference (optional) I4797739 PROBUILD, MOORESVILLE, IN 46158 7.250 s Apr 21 2011 MiTek Industries, Inc. Thu Jun 23 18:34:45 2011 Page 1 ID:IvJazOcGaW7oP7FTFIz4YgzLu67-zqWuyJFi85JLTy9t4tnx2F_GkyaMubgIxH7GH_z3Jfe Scale = 1:11.6 T1 B1 1 2 4 5 3 6 2x4 1-4-12 1-4-12 10-1-2 11-0-1 10-1-2 -1-3-4 1-3-4 1-4-12 1-4-12 10-1-2 11-0-1 10-1-2 0-4-10 1-5-3 1-4-7 0-10-15 9.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING Plates Increase Lumber Increase Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI TC Job B11112048 Truss J05 Truss Type Jack-Open Truss Qty 1 Ply 1 Job Reference (optional) I4797740 PROBUILD, MOORESVILLE, IN 46158 7.250 s Apr 21 2011 MiTek Industries, Inc. Thu Jun 23 18:34:46 2011 Page 1 ID:IvJazOcGaW7oP7FTFIz4YgzLu67-R04H9fGKvPRB46k3daIAaTWQZLved2vRAxtqpRz3Jfd Scale = 1:14.2 T1 B1 HW1 1 2 4 5 3 6 3x6 1-2-6 1-2-6 10-1-2 11-4-15 10-1-2 -1-3-4 1-3-4 1-2-6 1-2-6 10-1-2 11-4-15 10-1-2 0-8-7 1-10-13 12.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING Plates Increase Lumber Increase Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI TC BC Job B11112048 Truss M01 Truss Type Monopitch Truss Qty 33 Ply 1 Job Reference (optional) I4797741 PROBUILD, MOORESVILLE, IN 46158 7.250 s Apr 21 2011 MiTek Industries, Inc. Thu Jun 23 18:34:46 2011 Page 1 ID:IvJazOcGaW7oP7FTFIz4YgzLu67-R04H9fGKvPRB46k3daIAaTWKWLqSd2vRAxtqpRz3Jfd Scale = 1:36.1 T1 W1 B1 HW1 1 2 3 4 1.5x4 3x6 1.5x4 5-10-12 5-10-12 10-1-2 10-1-2 -1-3-4 1-3-4 5-10-12 5-10-12 10-1-2 10-1-2 0-8-7 6-7-3 12.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING Plates Increase Lumber Increase Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI TC BC WB (Matrix) Job B11112048 Truss M02 Truss Type Monopitch Truss Qty 1 Ply 1 Job Reference (optional) I4797742 PROBUILD, MOORESVILLE, IN 46158 7.250 s Apr 21 2011 MiTek Industries, Inc. Thu Jun 23 18:34:47 2011 Page 1 ID:IvJazOcGaW7oP7FTFIz4YgzLu67-vDefN?Hygja2iFJFBIpP7g3VGlAhMV9aObcNMtz3Jfc Scale = 1:36.1 T1 W1 B1 HW1 1 2 3 4 1.5x4 3x6 1.5x4 5-10-12 5-10-12 10-1-2 -1-3-4 1-3-4 5-10-12 5-10-12 10-1-2 0-8-7 6-7-3 12.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING Plates Increase Lumber Increase Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI TC BC WB (Matrix) Job B11112048 Truss M03 Truss Type Monopitch Truss Qty 7 Ply 1 Job Reference (optional) I4797743 PROBUILD, MOORESVILLE, IN 46158 7.250 s Apr 21 2011 MiTek Industries, Inc. Thu Jun 23 18:34:47 2011 Page 1 ID:IvJazOcGaW7oP7FTFIz4YgzLu67-vDefN?Hygja2iFJFBIpP7g3aRlDmMV9aObcNMtz3Jfc Scale = 1:20.8 T1 W1 B1 1 2 3 4 1.5x4 2x4 1.5x4 4-0-0 4-0-0 10-1-2 10-1-2 -1-3-4 1-3-4 4-0-0 4-0-0 10-1-2 10-1-2 0-4-10 3-4-10 9.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING Plates Increase Lumber Increase Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI TC BC WB (Matrix) 0.18 Job B11112048 Truss T01 Truss Type Hip Truss Qty 1 Ply 1 Job Reference (optional) I4797744 PROBUILD, MOORESVILLE, IN 46158 7.250 s Apr 21 2011 MiTek Industries, Inc. Thu Jun 23 18:34:48 2011 Page 1 ID:IvJazOcGaW7oP7FTFIz4YgzLu67-NPC1aLIaR0ivKPuSl?KegucYr9NM5ixkdEMwuJz3Jfb Scale = 1:87.9 T2 T3 T2 B1 W1 W2 W3 W4 W3 W4 W3 W5 W6 T1 T4 T1 B2 B3 B1 O3 O3 1 2 3 4 5 6 7 8 9 10 11 12 20 19 18 17 16 15 14 13 3x6 5x10 MT18H 3x8 7x16 MT18H 3x6 5x8 3x6 3x6 2x4 3x6 4x8 2x4 3x6 3x6 3x6 3x4 5x8 3x6 8-3-14 8-3-14 16-3-7 7-11-9 24-3-8 Job B11112048 Truss T01A Truss Type HIP TRUSS Qty 3 Ply 1 Job Reference (optional) I4797745 PROBUILD, MOORESVILLE, IN 46158 7.250 s Apr 21 2011 MiTek Industries, Inc. Thu Jun 23 18:34:49 2011 Page 1 ID:IvJazOcGaW7oP7FTFIz4YgzLu67-rbmPnhICCKqmxZTeJjrtC58oHZjaq9Itsu5UQlz3Jfa Scale = 1:86.6 T2 T3 T2 B1 W1 W2 W3 W4 W3 W4 W3 W5 W6 T1 T4 T5 B2 B3 B1 O3 O3 1 2 3 4 5 6 7 8 9 10 11 19 18 17 16 15 14 13 12 3x6 5x10 MT18H 3x8 7x16 MT18H 3x6 4x8 3x6 3x6 2x4 3x6 4x8 2x4 3x6 3x6 3x6 3x4 5x8 3x6 8-3-14 8-3-14 16-3-7 7-11-9 24-3-8 8-0-1 Job B11112048 Truss T01B Truss Type Hip Truss Qty 1 Ply 1 Job Reference (optional) I4797746 PROBUILD, MOORESVILLE, IN 46158 7.250 s Apr 21 2011 MiTek Industries, Inc. Thu Jun 23 18:34:51 2011 Page 1 ID:IvJazOcGaW7oP7FTFIz4YgzLu67-o_u9CNKSkx4UBtc0Q8tLHWE7JMQaIAnAJCabVez3JfY Scale = 1:86.7 T2 T3 T2 B1 W1 W2 W3 W4 W3 W4 W3 W2 W1 T1 T4 T5 B2 B3 B1 O3 1 2 3 4 5 6 7 8 9 10 11 19 18 17 16 15 14 13 12 3x6 8x14 MT18H 3x8 8x14 MT18H 3x6 4x10 3x6 3x6 2x4 3x6 3x8 2x4 3x6 3x6 3x6 2x4 4x10 3x6 8-3-14 8-3-14 16-3-7 Job B11112048 Truss T01C Truss Type HIP TRUSS Qty 5 Ply 1 Job Reference (optional) I4797747 PROBUILD, MOORESVILLE, IN 46158 7.250 s Apr 21 2011 MiTek Industries, Inc. Thu Jun 23 18:34:52 2011 Page 1 ID:IvJazOcGaW7oP7FTFIz4YgzLu67-GARYQjL5VFCLo1BD_rPaqkmI1mlo1d0KYsK814z3JfX Scale = 1:85.3 T2 T3 T2 B1 W1 W2 W3 W4 W3 W4 W3 W2 W1 T1 T4 T1 B2 B3 B1 1 2 3 4 5 6 7 8 9 10 18 17 16 15 14 13 12 11 3x6 8x14 MT18H 3x8 8x14 MT18H 3x6 4x10 3x6 3x6 2x4 3x6 3x8 2x4 3x6 3x6 2x4 4x10 3x6 3x6 8-3-14 8-3-14 16-3-7 Job B11112048 Truss T01D Truss Type Hip Truss Qty 1 Ply 1 Job Reference (optional) I4797748 PROBUILD, MOORESVILLE, IN 46158 7.250 s Apr 21 2011 MiTek Industries, Inc. Thu Jun 23 18:34:53 2011 Page 1 ID:IvJazOcGaW7oP7FTFIz4YgzLu67-kN?wd2MjGZKCQAmPYYwpMxJTpA52m4FTnW3hZXz3JfW Scale = 1:86.6 T2 T3 T2 B1 W1 W2 W3 W4 W3 W4 W3 W2 W1 T1 T4 T5 B2 B3 B1 O3 1 2 3 4 5 6 7 8 9 10 11 19 18 17 16 15 14 13 12 3x6 8x14 MT18H 3x8 8x14 MT18H 3x6 4x10 3x6 3x6 2x4 3x6 3x8 2x4 3x6 3x6 2x4 4x10 3x6 3x6 8-3-14 8-3-14 Job B11112048 Truss T02 Truss Type HIP TRUSS Qty 1 Ply 1 Job Reference (optional) I4797749 PROBUILD, MOORESVILLE, IN 46158 7.250 s Apr 21 2011 MiTek Industries, Inc. Thu Jun 23 18:34:55 2011 Page 1 ID:IvJazOcGaW7oP7FTFIz4YgzLu67-gl7g2kNzoAawfUwofzyISMOne_ltEuhmEqYoePz3JfU Scale = 1:87.4 T2 T3 T5 B1 B2 B3 B5 B6 W7 W7 W9 W10 W8 W6 W3 W4 W5 W1 W2 T1 T4 T6 B4 B7 O1 HW2 O3 O4 O4 1 2 23 3 4 5 6 7 8 9 10 11 12 21 20 19 18 17 16 15 14 13 8x8 5x8 3x6 8x8 3x6 3x8 2x4 5x8 3x6 3x6 3x4 Job B11112048 Truss T03 Truss Type HIP TRUSS Qty 1 Ply 1 Job Reference (optional) I4797750 PROBUILD, MOORESVILLE, IN 46158 7.250 s Apr 21 2011 MiTek Industries, Inc. Thu Jun 23 18:34:56 2011 Page 1 ID:IvJazOcGaW7oP7FTFIz4YgzLu67-8xh2F4ObZUinHeV_DhTX_axzZN6PzKvvTUILAsz3JfT Scale = 1:86.9 T2 T3 T4 T5 T6 B1 B2 B3 B5 B6 W1 W3 W2 W4 W8 W7 W6 W5 W3 W10 W11 W3 W9 W9 T1 O1 T7 B4 B7 O4 O5 O7 1 2 24 3 4 5 6 7 8 9 10 11 22 21 12 20 19 18 17 16 15 14 13 8x8 Job B11112048 Truss T04 Truss Type Hip Truss Qty 1 Ply 1 Job Reference (optional) I4797751 PROBUILD, MOORESVILLE, IN 46158 7.250 s Apr 21 2011 MiTek Industries, Inc. Thu Jun 23 18:34:57 2011 Page 1 ID:IvJazOcGaW7oP7FTFIz4YgzLu67-c8FRTQPDJnqevo4AnO_mXnU83nVDiu43h81viIz3JfS Scale = 1:70.7 T2 T3 T2 B1 W1 W2 W3 W4 W3 W2 W1 T1 T1 B2 B1 1 2 3 4 5 6 7 8 9 10 16 15 14 13 12 11 3x6 6x8 5x8 3x6 4x8 3x6 3x6 1.5x4 3x4 3x8 3x6 1.5x4 3x6 4x8 8-3-14 8-3-14 16-3-7 7-11-9 22-3-9 6-0-3 30-3-2 7-11-9 38-7-0 8-3-14 10-1-2 10-1-2 -1-3-4 1-3-4 8-3-14 Job B11112048 Truss T04A Truss Type Hip Truss Qty 2 Ply 1 Job Reference (optional) I4797752 PROBUILD, MOORESVILLE, IN 46158 7.250 s Apr 21 2011 MiTek Industries, Inc. Thu Jun 23 18:34:58 2011 Page 1 ID:IvJazOcGaW7oP7FTFIz4YgzLu67-4KppgmPr45yUWyfNK6V?3?0IABrdRLACwonSEkz3JfR Scale = 1:68.8 T2 T3 T2 B1 W1 W2 W3 W4 W3 W2 W1 T1 T4 B2 B1 1 2 3 4 5 6 7 8 9 15 14 13 12 11 10 3x6 6x8 5x8 3x6 4x8 3x6 3x6 1.5x4 3x4 3x8 3x6 1.5x4 3x6 5x8 8-3-14 8-3-14 16-3-7 7-11-9 22-3-9 6-0-3 30-3-2 7-11-9 38-7-0 8-3-14 10-1-2 10-1-2 -1-3-4 1-3-4 8-3-14 8-3-14 Job B11112048 Truss T04B Truss Type Hip Truss Qty 1 Ply 1 Job Reference (optional) I4797753 PROBUILD, MOORESVILLE, IN 46158 7.250 s Apr 21 2011 MiTek Industries, Inc. Thu Jun 23 18:35:00 2011 Page 1 ID:IvJazOcGaW7oP7FTFIz4YgzLu67-1jwZ5SR6ciCCmFolSXYT9Q6kz?TBvJnVO6GZJdz3JfP Scale = 1:70.7 T2 T3 T2 B1 W1 W2 W3 W4 W4 W3 W2 W1 T1 T1 B2 B1 1 2 3 4 5 6 7 8 9 10 11 17 16 15 14 13 12 3x6 5x6 5x6 3x6 4x8 3x6 3x6 1.5x4 3x8 3x4 3x8 3x6 3x6 1.5x4 4x8 6-11-14 6-11-14 13-7-7 6-7-9 24-11-9 11-4-3 31-7-2 6-7-9 38-7-0 6-11-14 10-1-2 10-1-2 Job B11112048 Truss T04C Truss Type Hip Truss Qty 1 Ply 1 Job Reference (optional) I4797754 PROBUILD, MOORESVILLE, IN 46158 7.250 s Apr 21 2011 MiTek Industries, Inc. Thu Jun 23 18:35:01 2011 Page 1 ID:IvJazOcGaW7oP7FTFIz4YgzLu67-VvUxJoSkN0K3NPNx0E3ihderWOoiekoecm?6r3z3JfO Scale = 1:70.7 T1 T2 T1 B1 W1 W2 W3 W2 W3 W2 W1 T3 B2 B1 O1 1 2 3 4 5 6 7 8 9 10 15 14 13 12 11 5x8 3x8 5x8 6x10 3x4 3x6 1.5x4 3x8 1.5x4 3x4 1.5x4 3x6 6x10 10-11-7 10-11-7 19-3-8 8-4-1 27-7-9 8-4-1 38-7-0 10-11-7 10-1-2 10-1-2 -1-3-4 1-3-4 5-7-14 5-7-14 Job B11112048 Truss T05 Truss Type HIP TRUSS Qty 1 Ply 1 Job Reference (optional) I4797755 PROBUILD, MOORESVILLE, IN 46158 7.250 s Apr 21 2011 MiTek Industries, Inc. Thu Jun 23 18:35:02 2011 Page 1 ID:IvJazOcGaW7oP7FTFIz4YgzLu67-z52KW7TM8KTw?Zy8ZxaxErB3boBNN4ForQlgNVz3JfN Scale = 1:69.1 T2 T3 T4 T5 T6 B1 B2 B3 B5 B6 W1 W3 W4 W2 W9 W7 W6 W5 W8 W10 W9 W11 W13 W12 T1O1 B4 B4 O4 O7 O5 O7 1 22 2 23 3 4 5 6 7 8 9 10 21 20 19 18 17 16 15 14 13 12 11 8x8 6x8 5x8 5x6 6x6 3x6 Job B11112048 Truss T06 Truss Type HIP TRUSS Qty 2 Ply 1 Job Reference (optional) I4797756 PROBUILD, MOORESVILLE, IN 46158 7.250 s Apr 21 2011 MiTek Industries, Inc. Thu Jun 23 18:35:03 2011 Page 1 ID:IvJazOcGaW7oP7FTFIz4YgzLu67-RIcijTT_vdbndjXK7f5Am2j8sCWF6XUx44UDwyz3JfM Scale = 1:67.3 T2 T3 T4 B1 B2 B3 B5 B6 W7 W9 W6 W5 W8 W3 W4 W1 W2 T1 O1 T5 B4 B7 O4 O5 1 2 19 3 4 5 6 7 8 9 17 16 15 14 13 12 11 10 8x8 6x8 8x8 3x6 3x8 1.5x4 4x8 3x6 3x6 3x4 2x4 3x6 8x8 3x6 Job B11112048 Truss T07 Truss Type Common Truss Qty 15 Ply 1 Job Reference (optional) I4797757 PROBUILD, MOORESVILLE, IN 46158 7.250 s Apr 21 2011 MiTek Industries, Inc. Thu Jun 23 18:35:04 2011 Page 1 ID:IvJazOcGaW7oP7FTFIz4YgzLu67-vUA4xpUcgxjeEt6WhMcPJGGPAcsPr725IkEnSOz3JfL Scale = 1:61.7 T2 T2 B1 W2 W1 W1 HW1 HW1 T1 T1 B1 1 2 3 4 5 6 7 8 9 10 3x6 4x6 3x6 6x10 5x12 1.5x4 1.5x4 6x10 11-3-8 11-3-8 22-7-0 11-3-8 10-1-2 10-1-2 -1-3-4 1-3-4 5-7-12 5-7-12 11-3-8 5-7-12 16-11-4 5-7-12 22-7-0 5-7-12 23-10-4 1-3-4 10-1-2 10-1-2 0-8-7 11-11-15 Job B11112048 Truss T08 Truss Type Half Hip Truss Qty 1 Ply 1 Job Reference (optional) I4797758 PROBUILD, MOORESVILLE, IN 46158 7.250 s Apr 21 2011 MiTek Industries, Inc. Thu Jun 23 18:35:05 2011 Page 1 ID:IvJazOcGaW7oP7FTFIz4YgzLu67-NgkS89VERFrVs0hjF48esTpUn0DmaTbEXOzK_qz3JfK Scale = 1:87.3 T2 T3 W6 B1 W1 W2 W3 W4 W3 W5 W3 W5 W3 W4 T1 T4 T5 B2 B3 B4 O3 O3 O6 1 2 3 4 5 6 7 8 9 10 11 20 19 18 17 16 15 14 13 12 3x6 8x14 MT18H 3x6 5x8 3x6 5x8 3x6 3x6 2x4 3x6 3x8 2x4 2x4 3x8 2x4 6x10 3x8 3x6 3x6 6-11-14 6-11-14 13-7-7 6-7-9 Job B11112048 Truss T10 Truss Type Half Hip Truss Qty 1 Ply 1 Job Reference (optional) I4797759 PROBUILD, MOORESVILLE, IN 46158 7.250 s Apr 21 2011 MiTek Industries, Inc. Thu Jun 23 18:35:06 2011 Page 1 ID:IvJazOcGaW7oP7FTFIz4YgzLu67-rtIqMVWtCYzMUAGvonftOhLiCPY7JsdNm2jtXGz3JfJ Scale = 1:87.5 T1 T2 W5 B1 W1 W2 W3 W2 W3 W2 W3 W2 W3 W2 W4 T3 T4 B2 B3 B4 1 2 3 4 5 6 7 8 9 10 11 20 19 18 17 16 15 14 13 12 5x8 3x6 5x8 3x4 5x12 3x6 4x8 2x4 3x8 2x4 2x4 3x8 2x4 3x8 2x4 6x8 3x6 3x6 3x6 10-11-7 10-11-7 18-6-8 7-7-1 26-0-5 7-5-13 33-6-2 7-5-13 40-11-15 7-5-13 48-7-0 7-7-1 Job B11112048 Truss T11 Truss Type Half Hip Truss Qty 1 Ply 1 Job Reference (optional) I4797760 PROBUILD, MOORESVILLE, IN 46158 7.250 s Apr 21 2011 MiTek Industries, Inc. Thu Jun 23 18:35:07 2011 Page 1 ID:IvJazOcGaW7oP7FTFIz4YgzLu67-K3rDZrWVzs5D5Kr5MVA6xuuwap?J2UAX?iSR3jz3JfI Scale = 1:38.5 W1 T1 T2 B1 W2 W1 HW2 1 2 3 4 6 5 3x6 5x6 4x6 3x4 4x8 2-8-5 2-8-5 9-1-8 6-5-3 10-1-2 10-1-2 2-8-5 2-8-5 9-1-8 6-5-3 10-4-12 1-3-4 10-1-2 10-1-2 7-1-10 0-8-7 7-1-10 12.00 12 Plate Offsets (X,Y): [3:Edge,0-0-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING Plates Increase Lumber Increase Rep Stress Incr Job B11112048 Truss T12 Truss Type Half Hip Truss Qty 1 Ply 1 Job Reference (optional) I4797761 PROBUILD, MOORESVILLE, IN 46158 7.250 s Apr 21 2011 MiTek Industries, Inc. Thu Jun 23 18:35:07 2011 Page 1 ID:IvJazOcGaW7oP7FTFIz4YgzLu67-K3rDZrWVzs5D5Kr5MVA6xuu_cp1f2WZX?iSR3jz3JfI Scale: 3/8"=1’ W1 T1 T2 B1 W2 W1 HW2 1 2 3 4 6 5 2x4 3x6 4x6 3x8 3x4 4-2-5 4-2-5 9-1-8 4-11-3 10-1-2 10-1-2 4-2-5 4-2-5 9-1-8 4-11-3 10-4-12 1-3-4 10-1-2 10-1-2 5-7-10 0-8-7 5-7-10 12.00 12 Plate Offsets (X,Y): [2:0-4-8,0-2-0], [3:Edge,0-0-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING Plates Increase Lumber Increase Job B11112048 Truss T13 Truss Type Common Truss Qty 1 Ply 1 Job Reference (optional) I4797762 PROBUILD, MOORESVILLE, IN 46158 7.250 s Apr 21 2011 MiTek Industries, Inc. Thu Jun 23 18:35:08 2011 Page 1 ID:IvJazOcGaW7oP7FTFIz4YgzLu67-oFPbnBX7kAD4jUQIwChLT6R9XDNtnzGgDMC_b9z3JfH Scale: 3/8"=1’ T1 T2 B1 W1 HW1 HW1 1 2 3 4 5 3x8 4x6 3x8 1.5x4 4-8-0 4-8-0 9-4-0 4-8-0 10-1-2 10-1-2 4-8-0 4-8-0 9-4-0 4-8-0 10-7-4 1-3-4 10-1-2 10-1-2 0-8-7 5-4-7 0-8-7 12.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING Plates Increase Lumber Increase Rep Stress Incr Code 2-0-0 Job B11112048 Truss T14 Truss Type Special Truss Qty 1 Ply 1 Job Reference (optional) I4797763 PROBUILD, MOORESVILLE, IN 46158 7.250 s Apr 21 2011 MiTek Industries, Inc. Thu Jun 23 18:35:09 2011 Page 1 ID:IvJazOcGaW7oP7FTFIz4YgzLu67-GSzz_XYlVTLxLe?UUvCa0JzK5dkLWQEqS0xX7bz3JfG Scale: 3/8"=1’ W1 T1 T2 T3 B1 W2 W3 W4 HW2 1 2 3 4 5 7 6 3x4 1.5x4 4x6 4x6 3x8 3x4 4-8-0 4-8-0 9-4-0 4-8-0 10-1-2 10-1-2 1-11-3 1-11-3 4-8-0 2-8-13 9-4-0 4-8-0 10-7-4 1-3-4 10-1-2 10-1-2 2-7-10 5-4-7 0-8-7 2-7-10 12.00 12 Plate Offsets (X,Y): [4:Edge,0-0-0] LOADING (psf) TCLL TCDL BCLL Job B11112048 Truss T15 Truss Type Special Truss Qty 1 Ply 1 Job Reference (optional) I4797764 PROBUILD, MOORESVILLE, IN 46158 7.250 s Apr 21 2011 MiTek Industries, Inc. Thu Jun 23 18:35:09 2011 Page 1 ID:IvJazOcGaW7oP7FTFIz4YgzLu67-GSzz_XYlVTLxLe?UUvCa0JzK0dkKWPrqS0xX7bz3JfG Scale: 3/8"=1’ W1 T1 T2 T3 B1 W2 W3 W4 HW2 1 2 3 4 5 7 6 3x4 1.5x4 5x6 4x6 3x8 3x4 4-5-8 4-5-8 9-1-8 4-8-0 10-1-2 10-1-2 3-2-11 3-2-11 4-5-8 1-2-13 9-1-8 4-8-0 10-4-12 1-3-4 10-1-2 10-1-2 4-1-10 5-4-7 0-8-7 4-1-10 12.00 12 Plate Offsets (X,Y): [4:Edge,0-0-0] LOADING (psf) TCLL TCDL BCLL Job B11112048 Truss T16 Truss Type Half Hip Truss Qty 3 Ply 1 Job Reference (optional) I4797765 PROBUILD, MOORESVILLE, IN 46158 7.250 s Apr 21 2011 MiTek Industries, Inc. Thu Jun 23 18:35:10 2011 Page 1 ID:IvJazOcGaW7oP7FTFIz4YgzLu67-keXLBsZNGnToyoZg1djpZXWT714SFtyzhgh5g2z3JfF Scale = 1:29.3 T1 T2 W1 B1 W1 W2 HW1 1 2 3 4 6 5 1.5x4 3x6 3x4 1.5x4 4x6 4-4-12 4-4-12 5-10-12 1-6-0 10-1-2 10-1-2 -1-3-4 1-3-4 4-4-12 4-4-12 5-10-12 1-6-0 10-1-2 10-1-2 0-8-7 5-1-3 12.00 12 Plate Offsets (X,Y): [3:0-4-8,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING Plates Increase Lumber Increase Rep Stress Incr Code 2-0-0 Job B11112048 Truss T17 Truss Type Half Hip Truss Qty 3 Ply 1 Job Reference (optional) I4797766 PROBUILD, MOORESVILLE, IN 46158 7.250 s Apr 21 2011 MiTek Industries, Inc. Thu Jun 23 18:35:10 2011 Page 1 ID:IvJazOcGaW7oP7FTFIz4YgzLu67-keXLBsZNGnToyoZg1djpZXWWk15xFtmzhgh5g2z3JfF Scale = 1:22.2 T1 T2 W1 B1 W1 W2 HW1 1 2 3 4 6 5 1.5x4 3x6 3x4 1.5x4 4x6 2-10-12 2-10-12 5-10-12 3-0-0 10-1-2 10-1-2 -1-3-4 1-3-4 2-10-12 2-10-12 5-10-12 3-0-0 10-1-2 10-1-2 0-8-7 3-7-3 12.00 12 Plate Offsets (X,Y): [3:0-4-8,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING Plates Increase Lumber Increase Rep Stress Incr Code 2-0-0 Job B11112048 Truss T18 Truss Type Hip Truss Qty 1 Ply 1 Job Reference (optional) I4797767 PROBUILD, MOORESVILLE, IN 46158 7.250 s Apr 21 2011 MiTek Industries, Inc. Thu Jun 23 18:35:11 2011 Page 1 ID:IvJazOcGaW7oP7FTFIz4YgzLu67-Cq5jPCZ?05beax8sbKE25k3aCQKC_GW7vJQeCUz3JfE Scale = 1:39.1 T1 T2 T1 B1 W1 W2 W1 HW1 HW1 1 2 3 4 5 6 8 7 5x8 4x8 4x10 1.5x4 3x4 4x10 7-2-3 7-2-3 8-9-13 1-7-10 16-0-0 7-2-3 10-1-2 10-1-2 -1-3-4 1-3-4 7-2-3 7-2-3 8-9-13 1-7-10 16-0-0 7-2-3 17-3-4 1-3-4 10-1-2 10-1-2 0-8-7 7-10-10 0-8-7 7-10-10 12.00 12 Plate Offsets (X,Y): [2:0-3-8,Edge], [3:0-4-8,0-1-4], [4:0-4-8,0-1-4], [5:0-3-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 Job B11112048 Truss T18A Truss Type Hip Truss Qty 1 Ply 1 Job Reference (optional) I4797768 PROBUILD, MOORESVILLE, IN 46158 7.250 s Apr 21 2011 MiTek Industries, Inc. Thu Jun 23 18:35:12 2011 Page 1 ID:IvJazOcGaW7oP7FTFIz4YgzLu67-g0f6cYadnOjVC5j392mHeyboZqjUjmAG8zACkwz3JfD Scale = 1:32.8 T1 T2 T1 B1 W1 W2 W1 HW1 HW1 1 2 3 4 5 6 8 7 4x6 4x6 3x8 3x8 1.5x4 3x4 5-8-3 5-8-3 10-3-13 4-7-10 16-0-0 5-8-3 10-1-2 10-1-2 -1-3-4 1-3-4 5-8-3 5-8-3 10-3-13 4-7-10 16-0-0 5-8-3 17-3-4 1-3-4 10-1-2 10-1-2 0-8-7 6-4-10 0-8-7 6-4-10 12.00 12 Plate Offsets (X,Y): [3:0-4-4,0-1-12], [4:0-4-4,0-1-12], [5:Edge,0-0-0] LOADING (psf) TCLL TCDL BCLL BCDL Job B11112048 Truss T18B Truss Type Hip Truss Qty 1 Ply 1 Job Reference (optional) I4797769 PROBUILD, MOORESVILLE, IN 46158 7.250 s Apr 21 2011 MiTek Industries, Inc. Thu Jun 23 18:35:12 2011 Page 1 ID:IvJazOcGaW7oP7FTFIz4YgzLu67-g0f6cYadnOjVC5j392mHeybmRqhkjn1G8zACkwz3JfD Scale: 3/8"=1’ T1 T2 T1 B1 W1 W2 W1 HW1 HW1 1 2 3 4 5 6 8 7 5x8 4x6 3x8 3x8 1.5x4 3x4 4-2-3 4-2-3 11-9-13 7-7-10 16-0-0 4-2-3 10-1-2 10-1-2 -1-3-4 1-3-4 4-2-3 4-2-3 11-9-13 7-7-10 16-0-0 4-2-3 17-3-4 1-3-4 10-1-2 10-1-2 0-8-7 4-10-10 0-8-7 4-10-10 12.00 12 Plate Offsets (X,Y): [3:0-4-12,0-1-8], [5:Edge,0-0-0] LOADING (psf) TCLL TCDL BCLL Job B11112048 Truss V01 Truss Type GABLE Qty 1 Ply 1 Job Reference (optional) I4797770 PROBUILD, MOORESVILLE, IN 46158 7.250 s Apr 21 2011 MiTek Industries, Inc. Thu Jun 23 18:35:13 2011 Page 1 ID:IvJazOcGaW7oP7FTFIz4YgzLu67-8DDUqubGYirMqFIFjlHWA98zHE1XSBhPNdvlGMz3JfC Scale = 1:55.3 T1 W1 B1 ST2 ST1 O1 1 2 3 4 3x4 7 6 5 4x6 3x6 1.5x4 1.5x4 1.5x4 1.5x4 11-5-9 11-5-9 10-4-0 11-5-9 11-5-9 10-4-0 0-0-4 11-5-9 12.00 12 Plate Offsets (X,Y): [4:0-4-7,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING Plates Increase Lumber Increase Rep Stress Incr Code 2-0-0 1.15 1.15 YES Job B11112048 Truss V02 Truss Type Valley Truss Qty 1 Ply 1 Job Reference (optional) I4797771 PROBUILD, MOORESVILLE, IN 46158 7.250 s Apr 21 2011 MiTek Industries, Inc. Thu Jun 23 18:35:13 2011 Page 1 ID:IvJazOcGaW7oP7FTFIz4YgzLu67-8DDUqubGYirMqFIFjlHWA98wWE2WSBZPNdvlGMz3JfC Scale = 1:49.3 T1 W1 B1 ST1 O1 1 2 3 3x8 5 4 3x6 3x8 1.5x4 1.5x4 9-11-9 9-11-9 11-10-0 9-11-9 9-11-9 11-10-0 9-11-9 12.00 12 Plate Offsets (X,Y): [1:0-6-1,Edge], [4:0-3-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING Plates Increase Lumber Increase Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI TC BC WB Job B11112048 Truss V03 Truss Type Valley Truss Qty 1 Ply 1 Job Reference (optional) I4797772 PROBUILD, MOORESVILLE, IN 46158 7.250 s Apr 21 2011 MiTek Industries, Inc. Thu Jun 23 18:35:14 2011 Page 1 ID:IvJazOcGaW7oP7FTFIz4YgzLu67-cPns1EcuJ?zDRPtRGToljNh2QeRnAhuZcHfIppz3JfB Scale = 1:42.0 T1 W1 B1 ST1 1 2 3 2x4 5 4 1.5x4 1.5x4 1.5x4 1.5x4 8-5-9 8-5-9 13-4-0 8-5-9 8-5-9 13-4-0 8-5-9 12.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING Plates Increase Lumber Increase Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI TC BC WB (Matrix) 0.83 0.17 Job B11112048 Truss V04 Truss Type Valley Truss Qty 1 Ply 1 Job Reference (optional) I4797773 PROBUILD, MOORESVILLE, IN 46158 7.250 s Apr 21 2011 MiTek Industries, Inc. Thu Jun 23 18:35:14 2011 Page 1 ID:IvJazOcGaW7oP7FTFIz4YgzLu67-cPns1EcuJ?zDRPtRGToljNh6qeQ1AizZcHfIppz3JfB Scale = 1:35.3 T1 W1 B1 ST1 1 2 3 5 4 2x4 1.5x4 1.5x4 1.5x4 1.5x4 6-11-9 6-11-9 14-10-0 6-11-9 6-11-9 14-10-0 6-11-9 12.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING Plates Increase Lumber Increase Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI TC BC WB (Matrix) 0.55 Job B11112048 Truss V05 Truss Type Valley Truss Qty 1 Ply 1 Job Reference (optional) I4797774 PROBUILD, MOORESVILLE, IN 46158 7.250 s Apr 21 2011 MiTek Industries, Inc. Thu Jun 23 18:35:14 2011 Page 1 ID:IvJazOcGaW7oP7FTFIz4YgzLu67-cPns1EcuJ?zDRPtRGToljNh3eeMAAirZcHfIppz3JfB Scale = 1:28.5 T1 W1 B1 1 2 3 2x4 1.5x4 1.5x4 5-5-9 5-5-9 16-4-0 5-5-9 5-5-9 16-4-0 5-5-9 12.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING Plates Increase Lumber Increase Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI TC BC WB (Matrix) 0.75 0.46 0.00 DEFL Job B11112048 Truss V06 Truss Type Valley Truss Qty 1 Ply 1 Job Reference (optional) I4797775 PROBUILD, MOORESVILLE, IN 46158 7.250 s Apr 21 2011 MiTek Industries, Inc. Thu Jun 23 18:35:15 2011 Page 1 ID:IvJazOcGaW7oP7FTFIz4YgzLu67-5bKEFadW4J543ZSeqAJ_GaDKM2m4v95iqxOsLFz3JfA Scale = 1:21.6 T1 W1 B1 1 2 3 2x4 1.5x4 1.5x4 3-11-9 3-11-9 17-10-0 3-11-9 3-11-9 17-10-0 3-11-9 12.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING Plates Increase Lumber Increase Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI TC BC WB (Matrix) 0.37 0.23 0.00 DEFL Job B11112048 Truss V07 Truss Type Valley Truss Qty 1 Ply 1 Job Reference (optional) I4797776 PROBUILD, MOORESVILLE, IN 46158 7.250 s Apr 21 2011 MiTek Industries, Inc. Thu Jun 23 18:35:15 2011 Page 1 ID:IvJazOcGaW7oP7FTFIz4YgzLu67-5bKEFadW4J543ZSeqAJ_GaDOE2oRv95iqxOsLFz3JfA Scale = 1:14.5 T1 W1 B1 1 2 3 2x4 1.5x4 1.5x4 2-5-9 2-5-9 19-4-0 2-5-9 2-5-9 19-4-0 2-5-9 12.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING Plates Increase Lumber Increase Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI TC BC WB (Matrix) 0.12 0.07 0.00 DEFL Job B11112048 Truss V08 Truss Type Valley Truss Qty 1 Ply 1 Job Reference (optional) I4797777 PROBUILD, MOORESVILLE, IN 46158 7.250 s Apr 21 2011 MiTek Industries, Inc. Thu Jun 23 18:43:01 2011 Page 1 ID:IvJazOcGaW7oP7FTFIz4YgzLu67-RFUP2wGpLVpyzA4C72gG8rW1Rusa5vSI_RHWhEz3JXu Scale = 1:7.2 T1 W1 B1 1 2 3 4x6 0-11-9 0-11-9 20-10-0 0-11-9 0-11-9 20-10-0 0-11-9 12.00 12 Plate Offsets (X,Y): [1:0-2-0,0-2-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING Plates Increase Lumber Increase Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI TC BC WB (Matrix) 0.00 0.00 0.00 DEFL Vert(LL) Job B11112048 Truss V14 Truss Type Valley Truss Qty 1 Ply 1 Job Reference (optional) I4797778 PROBUILD, MOORESVILLE, IN 46158 7.250 s Apr 21 2011 MiTek Industries, Inc. Thu Jun 23 18:35:16 2011 Page 1 ID:IvJazOcGaW7oP7FTFIz4YgzLu67-ZoucSwd8rdDxhj1qOuqDoomRcR6NecMs3b8Pthz3Jf9 Scale = 1:36.6 T1 W1 B1 ST1 1 2 3 5 4 2x4 1.5x4 1.5x4 1.5x4 1.5x4 7-2-13 7-2-13 11-1-0 7-2-13 7-2-13 11-1-0 7-2-13 12.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING Plates Increase Lumber Increase Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI TC BC WB (Matrix) 0.59 Job B11112048 Truss V15 Truss Type Valley Truss Qty 1 Ply 1 Job Reference (optional) I4797779 PROBUILD, MOORESVILLE, IN 46158 7.250 s Apr 21 2011 MiTek Industries, Inc. Thu Jun 23 18:35:16 2011 Page 1 ID:IvJazOcGaW7oP7FTFIz4YgzLu67-ZoucSwd8rdDxhj1qOuqDoomNqR2recLs3b8Pthz3Jf9 Scale = 1:29.8 T1 W1 B1 1 2 3 2x4 1.5x4 1.5x4 5-8-13 5-8-13 12-7-0 5-8-13 5-8-13 12-7-0 5-8-13 12.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING Plates Increase Lumber Increase Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI TC BC WB (Matrix) 0.83 0.51 0.00 DEFL Job B11112048 Truss V16 Truss Type Valley Truss Qty 1 Ply 1 Job Reference (optional) I4797780 PROBUILD, MOORESVILLE, IN 46158 7.250 s Apr 21 2011 MiTek Industries, Inc. Thu Jun 23 18:35:17 2011 Page 1 ID:IvJazOcGaW7oP7FTFIz4YgzLu67-1_S?fGemcwLoIsc0ybLSL?JfxrRzN3b?IFtzP8z3Jf8 Scale = 1:22.8 T1 W1 B1 1 2 3 2x4 1.5x4 1.5x4 4-2-13 4-2-13 14-1-0 4-2-13 4-2-13 14-1-0 4-2-13 12.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING Plates Increase Lumber Increase Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI TC BC WB (Matrix) 0.43 0.26 0.00 DEFL Job B11112048 Truss V17 Truss Type Valley Truss Qty 1 Ply 1 Job Reference (optional) I4797781 PROBUILD, MOORESVILLE, IN 46158 7.250 s Apr 21 2011 MiTek Industries, Inc. Thu Jun 23 18:35:17 2011 Page 1 ID:IvJazOcGaW7oP7FTFIz4YgzLu67-1_S?fGemcwLoIsc0ybLSL?JjBrUaN3b?IFtzP8z3Jf8 Scale = 1:15.7 T1 W1 B1 1 2 3 2x4 1.5x4 1.5x4 2-8-13 2-8-13 15-7-0 2-8-13 2-8-13 15-7-0 2-8-13 12.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING Plates Increase Lumber Increase Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI TC BC WB (Matrix) 0.16 0.10 0.00 DEFL Job B11112048 Truss V18 Truss Type Valley Truss Qty 1 Ply 1 Job Reference (optional) I4797782 PROBUILD, MOORESVILLE, IN 46158 7.250 s Apr 21 2011 MiTek Industries, Inc. Thu Jun 23 18:35:18 2011 Page 1 ID:IvJazOcGaW7oP7FTFIz4YgzLu67-VA0NtcfONEUfw0BDVIshtDrv3Fq76Wr8WvdWyaz3Jf7 Scale = 1:8.5 T1 W1 B1 1 2 3 2x4 1.5x4 1.5x4 1-2-13 1-2-13 17-1-0 1-2-13 1-2-13 17-1-0 1-2-13 12.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING Plates Increase Lumber Increase Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI TC BC WB (Matrix) 0.02 0.01 0.00 DEFL Job B11112048 Truss V19 Truss Type Valley Truss Qty 1 Ply 1 Job Reference (optional) I4797783 PROBUILD, MOORESVILLE, IN 46158 7.250 s Apr 21 2011 MiTek Industries, Inc. Thu Jun 23 18:35:18 2011 Page 1 ID:IvJazOcGaW7oP7FTFIz4YgzLu67-VA0NtcfONEUfw0BDVIshtDrtoFpq6UY8WvdWyaz3Jf7 Scale = 1:36.1 T1 T1 B1 ST2 ST1 ST1 1 2 3 4 5 8 7 6 3x4 4x6 1.5x4 1.5x4 3x4 1.5x4 1.5x4 1.5x4 13-10-2 13-10-2 11-7-0 6-11-1 6-11-1 13-10-2 6-11-1 11-7-0 6-11-1 12.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING Plates Increase Lumber Increase Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 Job B11112048 Truss V20 Truss Type Valley Truss Qty 1 Ply 1 Job Reference (optional) I4797784 PROBUILD, MOORESVILLE, IN 46158 7.250 s Apr 21 2011 MiTek Industries, Inc. Thu Jun 23 18:35:19 2011 Page 1 ID:IvJazOcGaW7oP7FTFIz4YgzLu67-zNal4xg18YcWYAlP30OwQQOzzf7ury9IlZM3U0z3Jf6 Scale = 1:28.9 T1 T1 B1 ST1 1 2 3 4 3x6 4x6 3x6 1.5x4 10-10-2 10-10-2 13-1-0 5-5-1 5-5-1 10-10-2 5-5-1 13-1-0 5-5-1 12.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING Plates Increase Lumber Increase Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI TC BC WB (Matrix) Job B11112048 Truss V21 Truss Type Valley Truss Qty 1 Ply 1 Job Reference (optional) I4797785 PROBUILD, MOORESVILLE, IN 46158 7.250 s Apr 21 2011 MiTek Industries, Inc. Thu Jun 23 18:35:19 2011 Page 1 ID:IvJazOcGaW7oP7FTFIz4YgzLu67-zNal4xg18YcWYAlP30OwQQO?7f7orzPIlZM3U0z3Jf6 Scale = 1:22.6 T1 T1 B1 ST1 1 2 3 4 2x4 4x6 1.5x4 2x4 7-10-2 7-10-2 14-7-0 3-11-1 3-11-1 7-10-2 3-11-1 14-7-0 3-11-1 12.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING Plates Increase Lumber Increase Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI TC BC WB (Matrix) 0.38 Job B11112048 Truss V22 Truss Type Valley Truss Qty 1 Ply 1 Job Reference (optional) I4797786 PROBUILD, MOORESVILLE, IN 46158 7.250 s Apr 21 2011 MiTek Industries, Inc. Thu Jun 23 18:35:20 2011 Page 1 ID:IvJazOcGaW7oP7FTFIz4YgzLu67-RZ87IHgfvrkN9KKbdjv9zexDr3VVaQ5R_D6d0Sz3Jf5 Scale = 1:14.0 T1 T1 B1 ST1 1 2 3 4 2x4 4x6 1.5x4 2x4 4-10-2 4-10-2 16-1-0 2-5-1 2-5-1 4-10-2 2-5-1 16-1-0 2-5-1 12.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING Plates Increase Lumber Increase Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI TC BC WB (Matrix) 0.13 edge of truss. / 16 " from outside 1 0 - PRODUCT CODE APPROVALS JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. W4-6 W3-6 W3-7 W2-7 W1-7 C1-8 C7-8 C6-7 C5-6 C4-5 C3-4 C1-2 C2-3 TOP CHORD TOP CHORD 8 7 6 5 4 1 2 3 BOTTOM CHORDS TOP CHORDS BEARING LATERAL BRACING LOCATION Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or proprietay bracing (e.g. eliminator) if indicated. The first dimension is the plate width measured perpendicular to slots. Second dimension is the length parallel to slots. 4 x 4 PLATE SIZE This symbol indicates the required direction of slots in connector plates. / 16 " 1 For 4 x 2 orientation, locate plates 0- Center plate on joint unless x, y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and fully embed teeth. 1 " / 4 3 PLATE LOCATION AND ORIENTATION Symbols Numbering System 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative T, I, or Eliminator bracing should be considered. 3. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. 5. Cut members to bear tightly against each other. 6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1. 7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1. 8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber. 10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements. 12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 13. Top chords must be sheathed or purlins provided at spacing indicated on design. 14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 15. Connections not shown are the responsibility of others. 16. Do not cut or alter truss member or plate without prior approval of an engineer. 17. Install and load vertically unless indicated otherwise. 18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use. 19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient. 20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria. 21. Unless information is otherwise provided to DrJ in writing, the use of these designs presumes approval, through the building designer or owner of the trusses, of the loads and related design assumptions (e.g. spans, profiles, deflection, etc.) found on each of the individ 22. These trusses are designed using MiTek Sapphire standard analysis methods in accordance with ANSI/TPI 1 and related proprietary information. 23. It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 24. Sheathing applied in the plane of the truss is not considered in the design of th components unles specifically noted. 25. Graphical purlin representation, if shown, does not depict the size or orientatio of the purlin along the top and/or bottom chord. Purlins must be designed by others for size, and positioned in such a way as to support the imposed load along the clearspan of the purlin. Failure to Follow Could Cause Property Damage or Personal Injury General Safety Notes * Plate location details available in MiTek 20/20 software or upon request. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. 6-4-8 dimensions shown in ft-in-sixteenths (Drawings not to scale) ' 2011 DrJ Consulting, LLC All Rights Reserved WEBS edge of truss. / 16 " from outside 1 0 - ICC-ES Reports: ESR-1311, ESR-1352, ER-5243, 9604B, 9730, 95-43, 96-31, 9667A NER-487, NER-561 95110, 84-32, 96-67, ER-3907, 9432A JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. W4-6 W3-6 W3-7 W2-7 W1-7 C1-8 C7-8 C6-7 C5-6 C4-5 C3-4 C1-2 C2-3 TOP CHORD TOP CHORD 8 7 6 5 4 1 2 3 BOTTOM CHORDS TOP CHORDS BEARING Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. 4 x 4 PLATE SIZE This symbol indicates the required direction of slots in connector plates. / 16 " 1 For 4 x 2 orientation, locate plates 0- 1 " / 4 3 PLATE LOCATION AND ORIENTATION Symbols Numbering System General Safety Notes * Plate location details available in MiTek 20/20 software or upon request. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. 6-4-8 dimensions shown in ft-in-sixteenths WEBS DrJ Consulting, LLC 6300 Enterprise Lane Madison, WI 53719 0.08 0.02 DEFL Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 14 lb FT = 20% GRIP 197/144 LUMBER TOP CHORD 2 X 4 SPF Stud BOT CHORD 2 X 4 SPF Stud OTHERS 2 X 3 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 4-10-2 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 1=102/4-10-2 (min. 0-1-8), 3=102/4-10-2 (min. 0-1-8), 4=128/4-10-2 (min. 0-1-8) Max Horz 1=-48(LC 4) Max Uplift 1=-17(LC 7), 3=-17(LC 7) Max Grav 1=102(LC 1), 3=102(LC 1), 4=129(LC 2) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/ diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage, delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from SBCA at www.sbcindustry.com. June 24,2011 0.24 0.04 DEFL Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 23 lb FT = 20% GRIP 197/144 LUMBER TOP CHORD 2 X 4 SPF Stud BOT CHORD 2 X 4 SPF Stud OTHERS 2 X 3 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 1=175/7-10-2 (min. 0-1-8), 3=175/7-10-2 (min. 0-1-8), 4=221/7-10-2 (min. 0-1-8) Max Horz 1=-83(LC 4) Max Uplift 1=-29(LC 7), 3=-29(LC 7) Max Grav 1=175(LC 1), 3=175(LC 1), 4=222(LC 2) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/ diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage, delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from SBCA at www.sbcindustry.com. June 24,2011 0.46 0.23 0.12 DEFL Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 33 lb FT = 20% GRIP 197/144 LUMBER TOP CHORD 2 X 4 SPF Stud BOT CHORD 2 X 4 SPF No.2 OTHERS 2 X 3 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 1=224/10-10-2 (min. 0-1-8), 3=224/10-10-2 (min. 0-1-8), 4=363/10-10-2 (min. 0-1-8) Max Horz 1=-118(LC 4) Max Uplift 1=-19(LC 7), 3=-19(LC 7) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/ diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage, delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from SBCA at www.sbcindustry.com. June 24,2011 CSI TC BC WB (Matrix) 0.16 0.09 0.15 DEFL Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 46 lb FT = 20% GRIP 197/144 LUMBER TOP CHORD 2 X 4 SPF No.2 BOT CHORD 2 X 4 SPF No.2 OTHERS 2 X 3 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS All bearings 13-10-2. (lb) - Max Horz 1=-153(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 1, 5 except 8=-141(LC 6), 6=-141(LC 7) Max Grav All reactions 250 lb or less at joint(s) 1, 5, 7 except 8=302(LC 10), 6=302(LC 11) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5 except (jt=lb) 8=141, 6=141. 6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/ diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage, delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from SBCA at www.sbcindustry.com. June 24,2011 Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 3 lb FT = 20% GRIP 197/144 LUMBER TOP CHORD 2 X 4 SPF Stud BOT CHORD 2 X 4 SPF Stud WEBS 2 X 3 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 1-2-13 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 1=31/1-2-13 (min. 0-1-8), 3=31/1-2-13 (min. 0-1-8) Max Horz 1=23(LC 5) Max Uplift 3=-9(LC 5) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 5) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/ diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage, delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from SBCA at www.sbcindustry.com. June 24,2011 Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 9 lb FT = 20% GRIP 197/144 LUMBER TOP CHORD 2 X 4 SPF Stud BOT CHORD 2 X 4 SPF Stud WEBS 2 X 3 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 2-8-13 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 1=91/2-8-13 (min. 0-1-8), 3=91/2-8-13 (min. 0-1-8) Max Horz 1=69(LC 5) Max Uplift 3=-27(LC 5) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 5) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/ diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage, delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from SBCA at www.sbcindustry.com. June 24,2011 Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 14 lb FT = 20% GRIP 197/144 LUMBER TOP CHORD 2 X 4 SPF Stud BOT CHORD 2 X 4 SPF Stud WEBS 2 X 3 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 4-2-13 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 1=151/4-2-13 (min. 0-1-8), 3=151/4-2-13 (min. 0-1-8) Max Horz 1=114(LC 5) Max Uplift 3=-45(LC 5) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 5) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/ diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage, delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from SBCA at www.sbcindustry.com. June 24,2011 Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 19 lb FT = 20% GRIP 197/144 LUMBER TOP CHORD 2 X 4 SPF Stud BOT CHORD 2 X 4 SPF Stud WEBS 2 X 3 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 5-8-13 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 1=211/5-8-13 (min. 0-1-8), 3=211/5-8-13 (min. 0-1-8) Max Horz 1=159(LC 5) Max Uplift 3=-62(LC 5) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 5) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/ diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage, delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from SBCA at www.sbcindustry.com. June 24,2011 0.22 0.06 DEFL Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 29 lb FT = 20% GRIP 197/144 LUMBER TOP CHORD 2 X 4 SPF No.2 BOT CHORD 2 X 4 SPF Stud WEBS 2 X 4 SPF Stud OTHERS 2 X 3 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 1=74/7-2-13 (min. 0-1-8), 4=123/7-2-13 (min. 0-1-8), 5=342/7-2-13 (min. 0-1-8) Max Horz 1=203(LC 5) Max Uplift 1=-55(LC 4), 4=-60(LC 5), 5=-161(LC 6) Max Grav 1=150(LC 5), 4=123(LC 1), 5=342(LC 1) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-5=-256/229 NOTES 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 4 except (jt=lb) 5=161. 5) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/ diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage, delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from SBCA at www.sbcindustry.com. June 24,2011 Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 2 lb FT = 20% GRIP 197/144 LUMBER TOP CHORD 2 X 4 SPF Stud BOT CHORD 2 X 4 SPF Stud WEBS 2 X 3 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 0-11-9 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 1=15/0-11-9 (min. 0-1-8), 3=15/0-11-9 (min. 0-1-8) Max Horz 1=15(LC 5) Max Uplift 1=-2(LC 4), 3=-9(LC 5) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 5) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/ diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage, delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from SBCA at www.sbcindustry.com. June 24,2011 Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 8 lb FT = 20% GRIP 197/144 LUMBER TOP CHORD 2 X 4 SPF Stud BOT CHORD 2 X 4 SPF Stud WEBS 2 X 3 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 2-5-9 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 1=80/2-5-9 (min. 0-1-8), 3=80/2-5-9 (min. 0-1-8) Max Horz 1=60(LC 5) Max Uplift 3=-24(LC 5) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 5) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/ diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage, delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from SBCA at www.sbcindustry.com. June 24,2011 Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 13 lb FT = 20% GRIP 197/144 LUMBER TOP CHORD 2 X 4 SPF Stud BOT CHORD 2 X 4 SPF Stud WEBS 2 X 3 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 3-11-9 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 1=140/3-11-9 (min. 0-1-8), 3=140/3-11-9 (min. 0-1-8) Max Horz 1=106(LC 5) Max Uplift 3=-41(LC 5) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 5) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/ diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage, delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from SBCA at www.sbcindustry.com. June 24,2011 Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 18 lb FT = 20% GRIP 197/144 LUMBER TOP CHORD 2 X 4 SPF Stud BOT CHORD 2 X 4 SPF Stud WEBS 2 X 3 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 5-5-9 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 1=200/5-5-9 (min. 0-1-8), 3=200/5-5-9 (min. 0-1-8) Max Horz 1=151(LC 5) Max Uplift 3=-59(LC 5) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 5) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/ diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage, delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from SBCA at www.sbcindustry.com. June 24,2011 0.21 0.06 DEFL Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 28 lb FT = 20% GRIP 197/144 LUMBER TOP CHORD 2 X 4 SPF No.2 BOT CHORD 2 X 4 SPF Stud WEBS 2 X 4 SPF Stud OTHERS 2 X 3 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 1=60/6-11-9 (min. 0-1-8), 4=124/6-11-9 (min. 0-1-8), 5=333/6-11-9 (min. 0-1-8) Max Horz 1=195(LC 5) Max Uplift 1=-57(LC 4), 4=-58(LC 5), 5=-156(LC 6) Max Grav 1=146(LC 5), 4=124(LC 1), 5=333(LC 1) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 4 except (jt=lb) 5=156. 5) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/ diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage, delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from SBCA at www.sbcindustry.com. June 24,2011 0.13 DEFL Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 35 lb FT = 20% GRIP 197/144 LUMBER TOP CHORD 2 X 4 SPF No.2 BOT CHORD 2 X 4 SPF No.2 WEBS 2 X 4 SPF Stud OTHERS 2 X 3 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 1=126/8-5-9 (min. 0-1-8), 4=113/8-5-9 (min. 0-1-8), 5=398/8-5-9 (min. 0-1-8) Max Horz 1=240(LC 5) Max Uplift 1=-51(LC 4), 4=-66(LC 5), 5=-187(LC 6) Max Grav 1=172(LC 5), 4=118(LC 4), 5=398(LC 1) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-5=-298/260 NOTES 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 4 except (jt=lb) 5=187. 5) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/ diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage, delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from SBCA at www.sbcindustry.com. June 24,2011 (Matrix) 0.58 0.36 0.26 DEFL Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 39 lb FT = 20% GRIP 197/144 LUMBER TOP CHORD 2 X 4 SPF No.2 BOT CHORD 2 X 4 SPF No.2 WEBS 2 X 3 SPF No.2 OTHERS 2 X 3 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS T-Brace: 2 X 4 SPF Stud - 3-4 Fasten (2X) T and I braces to narrow edge of web with 10d (0.131"x3") nails, 6in o.c.,with 3in minimum end distance. Brace must cover 90% of web length. REACTIONS (lb/size) 1=182/9-11-9 (min. 0-1-8), 4=95/9-11-9 (min. 0-1-8), 5=484/9-11-9 (min. 0-1-8) Max Horz 1=286(LC 5) Max Uplift 1=-48(LC 4), 4=-75(LC 5), 5=-230(LC 6) Max Grav 1=200(LC 5), 4=128(LC 4), 5=484(LC 1) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-277/185 WEBS 2-5=-339/232 NOTES 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 4 except (jt=lb) 5=230. 5) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 6) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required. LOAD CASE(S) Standard WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/ diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage, delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from SBCA at www.sbcindustry.com. June 24,2011 IRC2006/TPI2002 CSI TC BC WB (Matrix) 0.41 0.42 0.31 DEFL Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 51 lb FT = 20% GRIP 197/144 LUMBER TOP CHORD 2 X 4 SPF No.2 BOT CHORD 2 X 4 SPF No.2 WEBS 2 X 4 SPF No.2 OTHERS 2 X 3 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS T-Brace: 2 X 4 SPF Stud - 4-5 Fasten (2X) T and I braces to narrow edge of web with 10d (0.131"x3") nails, 6in o.c.,with 3in minimum end distance. Brace must cover 90% of web length. REACTIONS All bearings 11-5-9. (lb) - Max Horz 1=330(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 1, 5 except 6=-164(LC 6), 7=-146(LC 6) Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 6=337(LC 1), 7=312(LC 1) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-341/191, 2-3=-264/192 WEBS 3-6=-256/166 NOTES 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5 except (jt=lb) 6=164, 7=146. 5) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 6) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required. LOAD CASE(S) Standard WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/ diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage, delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from SBCA at www.sbcindustry.com. June 24,2011 BCDL 20.0 10.0 0.0 10.0 SPACING Plates Increase Lumber Increase Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI TC BC WB (Matrix) 0.54 0.39 0.08 DEFL Vert(LL) Vert(TL) Horz(TL) in -0.07 -0.18 0.02 (loc) 7-8 7-8 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 61 lb FT = 20% GRIP 197/144 LUMBER TOP CHORD 2 X 4 SPF No.2 BOT CHORD 2 X 4 SPF No.2 WEBS 2 X 3 SPF No.2 WEDGE Left: 2 X 6 SPF No.2, Right: 2 X 6 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 5-9-9 oc purlins, except 2-0-0 oc purlins (6-0-0 max.): 3-4. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS T-Brace: 2 X 4 SPF Stud - 3-7 Fasten (2X) T and I braces to narrow edge of web with 10d (0.131"x3") nails, 6in o.c.,with 3in minimum end distance. Brace must cover 90% of web length. REACTIONS (lb/size) 2=716/0-3-8 (min. 0-1-8), 5=716/0-3-8 (min. 0-1-8) Max Horz 2=-109(LC 4) Max Uplift 2=-50(LC 6), 5=-50(LC 7) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-777/76, 3-4=-490/108, 4-5=-778/76 BOT CHORD 2-8=-73/487, 7-8=-71/490, 5-7=-13/487 WEBS 3-8=0/266, 4-7=0/267 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 5. 6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Design assumes 4x2 (flat orientation) purlins at oc spacing indicated, fastened to truss TC w/ 2-10d nails. 8) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required. LOAD CASE(S) Standard WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/ diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage, delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from SBCA at www.sbcindustry.com. June 24,2011 20.0 10.0 0.0 10.0 SPACING Plates Increase Lumber Increase Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI TC BC WB (Matrix) 0.40 0.28 0.14 DEFL Vert(LL) Vert(TL) Horz(TL) in 0.04 -0.10 0.01 (loc) 2-8 2-8 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 64 lb FT = 20% GRIP 197/144 LUMBER TOP CHORD 2 X 4 SPF No.2 BOT CHORD 2 X 4 SPF No.2 WEBS 2 X 3 SPF No.2 WEDGE Left: 2 X 6 SPF No.2, Right: 2 X 6 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except 2-0-0 oc purlins (6-0-0 max.): 3-4. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 2=716/0-3-8 (min. 0-1-8), 5=716/0-3-8 (min. 0-1-8) Max Horz 2=-144(LC 4) Max Uplift 2=-55(LC 6), 5=-55(LC 7) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-721/88, 3-4=-415/128, 4-5=-721/88 BOT CHORD 2-8=-50/413, 7-8=-49/415, 5-7=0/413 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 5. 6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Design assumes 4x2 (flat orientation) purlins at oc spacing indicated, fastened to truss TC w/ 2-10d nails. LOAD CASE(S) Standard WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/ diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage, delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from SBCA at www.sbcindustry.com. June 24,2011 10.0 0.0 10.0 SPACING Plates Increase Lumber Increase Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI TC BC WB (Matrix) 0.64 0.48 0.36 DEFL Vert(LL) Vert(TL) Horz(TL) in -0.08 -0.23 0.01 (loc) 5-7 5-7 5 l/defl >999 >844 n/a L/d 240 180 n/a PLATES MT20 Weight: 68 lb FT = 20% GRIP 197/144 LUMBER TOP CHORD 2 X 4 SPF No.2 BOT CHORD 2 X 4 SPF No.2 WEBS 2 X 3 SPF No.2 WEDGE Left: 2 X 6 SPF No.2, Right: 2 X 6 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except 2-0-0 oc purlins (6-0-0 max.): 3-4. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 2=716/0-3-8 (min. 0-1-8), 5=716/0-3-8 (min. 0-1-8) Max Horz 2=-180(LC 4) Max Uplift 2=-57(LC 6), 5=-57(LC 7) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-695/95, 3-4=-383/155, 4-5=-695/94 BOT CHORD 2-8=-23/377, 7-8=-23/379, 5-7=0/379 WEBS 3-7=-249/258, 4-7=-151/264 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 5. 6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Design assumes 4x2 (flat orientation) purlins at oc spacing indicated, fastened to truss TC w/ 2-10d nails. LOAD CASE(S) Standard WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/ diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage, delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from SBCA at www.sbcindustry.com. June 24,2011 1.15 1.15 YES IRC2006/TPI2002 CSI TC BC WB (Matrix) 0.17 0.10 0.07 DEFL Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.01 0.00 (loc) 2-6 2-6 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 27 lb FT = 20% GRIP 197/144 LUMBER TOP CHORD 2 X 4 SPF No.2 BOT CHORD 2 X 4 SPF No.2 WEBS 2 X 3 SPF No.2 WEDGE Left: 2 X 8 SYP 2400F 2.0E BRACING TOP CHORD Structural wood sheathing directly applied or 5-10-12 oc purlins, except end verticals, and 2-0-0 oc purlins: 3-4. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. JOINTS 1 Brace at Jt(s): 4 REACTIONS (lb/size) 5=223/Mechanical, 2=316/0-5-8 (min. 0-1-8) Max Horz 2=112(LC 5) Max Uplift 5=-38(LC 5), 2=-46(LC 6) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 2. 6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Design assumes 4x2 (flat orientation) purlins at oc spacing indicated, fastened to truss TC w/ 2-10d nails. LOAD CASE(S) Standard WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/ diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage, delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from SBCA at www.sbcindustry.com. June 24,2011 1.15 1.15 YES IRC2006/TPI2002 CSI TC BC WB (Matrix) 0.34 0.19 0.12 DEFL Vert(LL) Vert(TL) Horz(TL) in -0.02 -0.04 0.00 (loc) 2-6 2-6 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 31 lb FT = 20% GRIP 197/144 LUMBER TOP CHORD 2 X 4 SPF No.2 BOT CHORD 2 X 4 SPF No.2 WEBS 2 X 3 SPF No.2 WEDGE Left: 2 X 8 SYP 2400F 2.0E BRACING TOP CHORD Structural wood sheathing directly applied or 5-10-12 oc purlins, except end verticals, and 2-0-0 oc purlins: 3-4. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. JOINTS 1 Brace at Jt(s): 4 REACTIONS (lb/size) 5=223/Mechanical, 2=316/0-5-8 (min. 0-1-8) Max Horz 2=157(LC 5) Max Uplift 5=-57(LC 5), 2=-35(LC 6) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 2. 6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Design assumes 4x2 (flat orientation) purlins at oc spacing indicated, fastened to truss TC w/ 2-10d nails. LOAD CASE(S) Standard WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/ diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage, delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from SBCA at www.sbcindustry.com. June 24,2011 BCDL 20.0 10.0 0.0 10.0 SPACING Plates Increase Lumber Increase Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI TC BC WB (Matrix) 0.23 0.18 0.18 DEFL Vert(LL) Vert(TL) Horz(TL) in -0.01 -0.03 0.00 (loc) 4-6 4-6 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 41 lb FT = 20% GRIP 197/144 LUMBER TOP CHORD 2 X 4 SPF No.2 BOT CHORD 2 X 4 SPF No.2 WEBS 2 X 3 SPF No.2 WEDGE Right: 2 X 6 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 1-2. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. JOINTS 1 Brace at Jt(s): 1 REACTIONS (lb/size) 7=355/0-5-8 (min. 0-1-8), 4=442/0-3-8 (min. 0-1-8) Max Horz 7=-179(LC 4) Max Uplift 7=-50(LC 4), 4=-48(LC 7) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 3-4=-373/65 WEBS 2-7=-291/52 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7, 4. 6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Design assumes 4x2 (flat orientation) purlins at oc spacing indicated, fastened to truss TC w/ 2-10d nails. LOAD CASE(S) Standard WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/ diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage, delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from SBCA at www.sbcindustry.com. June 24,2011 BCDL 20.0 10.0 0.0 10.0 SPACING Plates Increase Lumber Increase Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI TC BC WB (Matrix) 0.23 0.18 0.09 DEFL Vert(LL) Vert(TL) Horz(TL) in -0.01 -0.03 0.00 (loc) 4-6 4-6 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 39 lb FT = 20% GRIP 197/144 LUMBER TOP CHORD 2 X 4 SPF No.2 BOT CHORD 2 X 4 SPF No.2 WEBS 2 X 3 SPF No.2 WEDGE Right: 2 X 6 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 1-2. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. JOINTS 1 Brace at Jt(s): 1 REACTIONS (lb/size) 7=364/0-3-8 (min. 0-1-8), 4=451/0-3-8 (min. 0-1-8) Max Horz 7=-161(LC 4) Max Uplift 7=-9(LC 7), 4=-51(LC 7) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-296/80, 3-4=-385/61 WEBS 2-7=-339/58 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7, 4. 6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Design assumes 4x2 (flat orientation) purlins at oc spacing indicated, fastened to truss TC w/ 2-10d nails. LOAD CASE(S) Standard WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/ diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage, delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from SBCA at www.sbcindustry.com. June 24,2011 1.15 1.15 YES IRC2006/TPI2002 CSI TC BC WB (Matrix) 0.21 0.20 0.07 DEFL Vert(LL) Vert(TL) Horz(TL) in -0.02 -0.04 0.00 (loc) 1-5 1-5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 34 lb FT = 20% GRIP 197/144 LUMBER TOP CHORD 2 X 4 SPF No.2 BOT CHORD 2 X 4 SPF No.2 WEBS 2 X 3 SPF No.2 WEDGE Left: 2 X 6 SPF No.2, Right: 2 X 6 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 1=368/0-3-8 (min. 0-1-8), 3=455/0-3-8 (min. 0-1-8) Max Horz 1=-131(LC 4) Max Uplift 1=-7(LC 6), 3=-53(LC 7) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-395/63, 2-3=-398/66 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 5) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/ diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage, delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from SBCA at www.sbcindustry.com. June 24,2011 Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI TC BC WB (Matrix) 0.23 0.20 0.10 DEFL Vert(LL) Vert(TL) Horz(TL) in -0.02 -0.05 0.00 (loc) 3-5 3-5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 40 lb FT = 20% GRIP 197/144 LUMBER TOP CHORD 2 X 4 SPF No.2 BOT CHORD 2 X 4 SPF No.2 WEBS 2 X 3 SPF No.2 WEDGE Right: 2 X 6 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 1-2. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. JOINTS 1 Brace at Jt(s): 1 REACTIONS (lb/size) 6=355/0-5-8 (min. 0-1-8), 3=442/0-3-8 (min. 0-1-8) Max Horz 6=-173(LC 4) Max Uplift 6=-60(LC 4), 3=-43(LC 7) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-6=-326/103, 2-3=-366/72 WEBS 1-5=-64/289 NOTES 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6, 3. 5) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 6) Design assumes 4x2 (flat orientation) purlins at oc spacing indicated, fastened to truss TC w/ 2-10d nails. LOAD CASE(S) Standard WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/ diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage, delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from SBCA at www.sbcindustry.com. June 24,2011 Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI TC BC WB (Matrix) 0.48 0.35 0.25 DEFL Vert(LL) Vert(TL) Horz(TL) in -0.05 -0.15 0.00 (loc) 3-5 3-5 3 l/defl >999 >738 n/a L/d 240 180 n/a PLATES MT20 Weight: 43 lb FT = 20% GRIP 197/144 LUMBER TOP CHORD 2 X 4 SPF No.2 BOT CHORD 2 X 4 SPF No.2 WEBS 2 X 3 SPF No.2 WEDGE Right: 2 X 6 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 1-2. BOT CHORD Structural wood sheathing directly applied or 6-0-0 oc bracing. JOINTS 1 Brace at Jt(s): 1 REACTIONS (lb/size) 6=355/0-5-8 (min. 0-1-8), 3=442/0-3-8 (min. 0-1-8) Max Horz 6=-219(LC 4) Max Uplift 6=-78(LC 4), 3=-32(LC 7) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-6=-372/120, 2-3=-333/73 WEBS 1-5=-120/400 NOTES 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6, 3. 5) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 6) Design assumes 4x2 (flat orientation) purlins at oc spacing indicated, fastened to truss TC w/ 2-10d nails. LOAD CASE(S) Standard WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/ diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage, delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from SBCA at www.sbcindustry.com. June 24,2011 10-1-2 10-1-2 -1-3-4 1-3-4 5-7-14 5-7-14 10-11-7 5-3-9 18-6-8 7-7-1 26-0-5 7-5-13 33-6-2 7-5-13 40-11-15 7-5-13 48-7-0 7-7-1 10-1-2 10-1-2 0-4-10 8-7-3 9.00 12 Plate Offsets (X,Y): [2:0-1-10,Edge], [4:0-5-4,0-2-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING Plates Increase Lumber Increase Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI TC BC WB (Matrix) 0.65 0.79 0.98 DEFL Vert(LL) Vert(TL) Horz(TL) in -0.30 -0.83 0.18 (loc) 2-20 2-20 12 l/defl >999 >700 n/a L/d 240 180 n/a PLATES MT20 Weight: 236 lb FT = 20% GRIP 197/144 LUMBER TOP CHORD 2 X 4 SPF No.2 BOT CHORD 2 X 4 SPF No.2 *Except* B1,B2: 2 X 4 SYP No.1 WEBS 2 X 4 SPF No.2 *Except* W1,W2: 2 X 3 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 2-9-5 oc purlins, except end verticals, and 2-0-0 oc purlins (2-11-7 max.): 4-11. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS T-Brace: 2 X 4 SPF No.2 - 8-13 2 X 4 SPF Stud - 5-20, 7-17, 10-13 2 X 6 SPF No.2 - 11-12 Fasten (2X) T and I braces to narrow edge of web with 10d (0.131"x3") nails, 6in o.c.,with 3in minimum end distance. Brace must cover 90% of web length. JOINTS 1 Brace at Jt(s): 11 REACTIONS (lb/size) 12=1927/0-5-8 (min. 0-3-0), 2=2020/0-5-8 (min. 0-2-6) Max Horz 2=262(LC 5) Max Uplift 12=-235(LC 4), 2=-66(LC 6) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2798/287, 3-4=-2567/293, 4-5=-1994/282, 5-6=-2823/367, 6-7=-2823/367, 7-8=-2823/367, 8-9=-1506/256, 9-10=-1506/256, 10-11=-1506/256, 11-12=-1851/284 BOT CHORD 2-20=-277/2144, 19-20=-305/2674, 18-19=-305/2674, 17-18=-305/2674, 16-17=-272/2432, 15-16=-272/2432, 14-15=-272/2432, 13-14=-272/2432 WEBS 4-20=-40/1090, 5-20=-1017/271, 5-18=0/261, 7-17=-445/177, 8-17=-56/584, 8-15=0/291, 8-13=-1383/133, 10-13=-471/179, 11-13=-257/2212 NOTES 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2 except (jt=lb) 12=235. 5) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 6) Design assumes 4x2 (flat orientation) purlins at oc spacing indicated, fastened to truss TC w/ 2-10d nails. 7) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required. LOAD CASE(S) Standard WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/ diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage, delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from SBCA at www.sbcindustry.com. June 24,2011 22-4-15 8-9-8 31-1-3 8-8-4 39-9-8 8-8-4 48-7-0 8-9-8 10-1-2 10-1-2 -1-3-4 1-3-4 6-11-14 6-11-14 13-7-7 6-7-9 22-4-15 8-9-8 31-1-3 8-8-4 39-9-8 8-8-4 48-7-0 8-9-8 10-1-2 10-1-2 0-4-10 10-7-3 9.00 12 Plate Offsets (X,Y): [2:0-1-4,Edge], [5:0-10-8,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING Plates Increase Lumber Increase Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI TC BC WB (Matrix) 0.89 0.74 0.71 DEFL Vert(LL) Vert(TL) Horz(TL) in -0.16 -0.51 0.17 (loc) 17-19 17-19 12 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 MT18H Weight: 248 lb FT = 20% GRIP 197/144 197/144 LUMBER TOP CHORD 2 X 4 SPF No.2 BOT CHORD 2 X 4 SPF No.2 WEBS 2 X 4 SPF No.2 *Except* W6: 2 X 4 SYP No.1, W1,W2: 2 X 3 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 2-7-14 oc purlins, except end verticals, and 2-0-0 oc purlins (2-8-12 max.): 5-11. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS T-Brace: 2 X 4 SPF Stud - 3-19, 5-17, 6-17, 8-17, 9-13, 11-13 2 X 6 SPF No.2 - 11-12, 8-13 Fasten (2X) T and I braces to narrow edge of web with 10d (0.131"x3") nails, 6in o.c.,with 3in minimum end distance. Brace must cover 90% of web length. JOINTS 1 Brace at Jt(s): 11 REACTIONS (lb/size) 12=1927/0-5-8 (min. 0-3-0), 2=2020/0-5-8 (min. 0-3-3) Max Horz 2=323(LC 5) Max Uplift 12=-201(LC 4), 2=-79(LC 6) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2863/249, 3-4=-2417/267, 4-5=-2202/311, 5-6=-2288/341, 6-7=-2288/342, 7-8=-2288/342, 8-9=-1378/256, 9-10=-1378/256, 10-11=-1378/256, 11-12=-1840/259 BOT CHORD 2-20=-266/2161, 19-20=-266/2161, 18-19=-251/1848, 17-18=-251/1848, 16-17=-261/2121, 15-16=-261/2121, 14-15=-261/2121, 13-14=-261/2121 WEBS 3-20=0/280, 3-19=-404/154, 5-19=0/500, 5-17=-245/677, 6-17=-535/230, 8-17=-34/259, 8-15=0/341, 8-13=-1153/110, 9-13=-549/207, 11-13=-198/2093 NOTES 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2 except (jt=lb) 12=201. 6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Design assumes 4x2 (flat orientation) purlins at oc spacing indicated, fastened to truss TC w/ 2-10d nails. 8) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required. LOAD CASE(S) Standard WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/ diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage, delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from SBCA at www.sbcindustry.com. June 24,2011 0-8-7 12.00 12 Plate Offsets (X,Y): [2:0-5-0,Edge], [8:0-5-0,Edge], [10:0-6-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING Plates Increase Lumber Increase Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI TC BC WB (Matrix) 0.49 0.87 0.28 DEFL Vert(LL) Vert(TL) Horz(TL) in -0.30 -0.78 0.03 (loc) 2-10 2-10 8 l/defl >915 >349 n/a L/d 240 180 n/a PLATES MT20 Weight: 94 lb FT = 20% GRIP 197/144 LUMBER TOP CHORD 2 X 4 SPF No.2 BOT CHORD 2 X 4 SPF No.2 WEBS 2 X 3 SPF No.2 *Except* W2: 2 X 4 SPF No.2 WEDGE Left: 2 X 6 SPF No.2, Right: 2 X 6 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 5-0-13 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 7-10, 3-10 REACTIONS (lb/size) 2=980/0-3-8 (min. 0-1-9), 8=980/0-3-8 (min. 0-1-9) Max Horz 2=-274(LC 4) Max Uplift 2=-64(LC 6), 8=-64(LC 7) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1005/124, 3-4=-794/134, 4-5=-666/178, 5-6=-666/178, 6-7=-794/134, 7-8=-1005/124 BOT CHORD 2-10=-70/642, 8-10=0/642 WEBS 5-10=-116/666, 7-10=-261/202, 3-10=-261/201 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 8. 5) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/ diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage, delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from SBCA at www.sbcindustry.com. June 24,2011 1.5x4 6x16 1.5x4 3x6 5x8 3-1-15 3-1-15 9-8-11 6-6-12 16-3-7 6-6-12 20-5-15 4-2-8 22-3-9 1-9-10 30-3-2 7-11-9 38-7-0 8-3-14 10-1-2 10-1-2 9-8-11 9-8-11 16-3-7 6-6-12 22-3-9 6-0-3 30-3-2 7-11-9 38-7-0 8-3-14 10-1-2 10-1-2 0-4-10 12-7-3 0-4-10 2-0-0 12-7-3 9.00 12 Plate Offsets (X,Y): [1:0-1-4,0-1-8], [2:0-2-11,0-0-12], [4:0-4-8,0-1-12], [6:0-4-8,0-1-12], [9:0-1-4,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING Plates Increase Lumber Increase Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI TC BC WB (Matrix) 0.85 0.87 0.87 DEFL Vert(LL) Vert(TL) Horz(TL) in -0.31 -0.80 0.63 (loc) 2-17 2-17 9 l/defl >999 >572 n/a L/d 240 180 n/a PLATES MT20 Weight: 249 lb FT = 20% GRIP 197/144 LUMBER TOP CHORD 2 X 4 SPF No.2 *Except* T1: 2 X 8 SYP 2400F 2.0E BOT CHORD 2 X 4 SPF No.2 *Except* B2: 2 X 3 SPF No.2 WEBS 2 X 3 SPF No.2 *Except* W7,W5,W3,W4: 2 X 4 SPF No.2 OTHERS 2 X 8 SYP 2400F 2.0E LBR SCAB 1-3 2 X 8 SYP 2400F 2.0E one side BRACING TOP CHORD Structural wood sheathing directly applied, except 2-0-0 oc purlins (3-11-15 max.): 4-6. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 13-14. T-Brace: 2 X 4 SPF Stud - 5-14 WEBS T-Brace: 2 X 4 SPF Stud - 6-12, 8-12, 4-14, 3-16 Fasten (2X) T and I braces to narrow edge of web with 10d (0.131"x3") nails, 6in o.c.,with 3in minimum end distance. Brace must cover 90% of web length. REACTIONS (lb/size) 1=1537/0-5-8 (min. 0-2-11), 9=1525/0-5-8 (min. 0-2-6) Max Horz 1=286(LC 5) Max Uplift 1=-46(LC 6), 9=-52(LC 7) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-842/137, 2-19=-2482/159, 3-19=-2269/193, 3-4=-1887/248, 4-5=-1399/245, 5-6=-1387/245, 6-7=-1475/260, 7-8=-1626/208, 8-9=-2195/193 BOT CHORD 2-17=-71/2166, 16-17=-69/2170, 15-16=-12/1402, 14-15=-12/1402, 11-12=-42/1629, 10-11=-42/1629, 9-10=-42/1629 WEBS 6-12=-963/123, 8-10=0/360, 12-14=0/1807, 6-14=-145/1398, 8-12=-579/191, 4-16=-41/716, 3-17=0/308, 3-16=-978/192 NOTES 1) Attached 12-3-1 scab 1 to 3, front face(s) 2 X 8 SYP 2400F 2.0E with 2 row(s) of 10d (0.131"x3") nails spaced 9" o.c.except : starting at 2-9-12 from end at joint 1, nail 2 row(s) at 7" o.c. for 2-0-0; starting at 10-1-0 from end at joint 1, nail 2 row(s) at 7" o.c. for 2-0-0. 2) Unbalanced roof live loads have been considered for this design. 3) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Bearing at joint(s) 1 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 9. 8) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Design assumes 4x2 (flat orientation) purlins at oc spacing indicated, fastened to truss TC w/ 2-10d nails. 10) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required. LOAD CASE(S) Standard WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/ diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage, delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from SBCA at www.sbcindustry.com. June 24,2011 4x8 1.5x4 4x8 3x6 3x6 2x4 2x4 3x6 1.5x4 3x4 8x8 4x6 6x16 4x6 5x6 3x8 3-1-15 3-1-15 9-8-11 6-6-12 16-3-7 6-6-12 20-5-15 4-2-8 22-3-9 1-9-10 27-7-9 5-4-0 32-7-9 5-0-0 38-7-0 5-11-7 10-1-2 10-1-2 9-8-11 9-8-11 16-3-7 6-6-12 22-3-9 6-0-3 27-7-9 5-4-0 32-7-9 5-0-0 37-7-9 5-0-0 38-7-0 0-11-7 10-1-2 10-1-2 0-4-10 8-7-3 12-7-3 7-10-10 2-0-0 12-7-3 9.00 12 Plate Offsets (X,Y): [2:0-2-11,0-0-12], [4:0-4-8,0-1-12], [6:0-5-12,0-1-12], [8:0-2-8,0-2-0], [9:0-4-0,0-2-0], [13:0-2-8,0-2-8], [14:0-2-8,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING Plates Increase Lumber Increase Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI TC BC WB (Matrix) 0.50 0.78 0.87 DEFL Vert(LL) Vert(TL) Horz(TL) in -0.24 -0.63 0.53 (loc) 2-20 2-20 11 l/defl >999 >722 n/a L/d 240 180 n/a PLATES MT20 Weight: 285 lb FT = 20% GRIP 197/144 LUMBER TOP CHORD 2 X 4 SPF No.2 *Except* T1: 2 X 8 SYP 2400F 2.0E BOT CHORD 2 X 4 SPF No.2 *Except* B2: 2 X 3 SPF No.2 WEBS 2 X 3 SPF No.2 *Except* W3,W4,W7,W5: 2 X 4 SPF No.2, W13: 2 X 4 SPF Stud OTHERS 2 X 8 SYP 2400F 2.0E LBR SCAB 1-3 2 X 8 SYP 2400F 2.0E one side BRACING TOP CHORD Structural wood sheathing directly applied or 3-9-13 oc purlins, except end verticals, and 2-0-0 oc purlins (4-7-7 max.): 4-6, 7-9. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 16-17. T-Brace: 2 X 4 SPF Stud - 5-17 WEBS T-Brace: 2 X 4 SPF Stud - 4-17, 3-19, 7-14, 6-15, 7-15, 8-13, 9-11 Fasten (2X) T and I braces to narrow edge of web with 10d (0.131"x3") nails, 6in o.c.,with 3in minimum end distance. Brace must cover 90% of web length. REACTIONS (lb/size) 1=1509/0-5-8 (min. 0-2-10), 11=1509/0-5-8 (min. 0-2-6) Max Horz 1=381(LC 5) Max Uplift 1=-45(LC 6), 11=-74(LC 5) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-22=-917/73, 2-22=-843/86, 2-23=-2406/166, 3-23=-2193/201, 3-4=-1839/255, 4-5=-1372/252, 5-6=-1361/252, 6-7=-1527/276, 7-8=-1410/223, 8-9=-915/183 BOT CHORD 2-20=-302/2056, 19-20=-301/2059, 18-19=-205/1364, 17-18=-205/1364, 14-15=-107/1419, 13-14=-111/915 WEBS 3-20=0/302, 4-19=-47/663, 3-19=-885/201, 7-14=-754/137, 6-15=-876/233, 15-17=-173/1758, 6-17=-301/1427, 7-15=-503/140, 8-13=-1157/160, 8-14=-80/975, 9-13=-133/1481, 9-11=-1395/262 NOTES 1) Attached 12-3-1 scab 1 to 3, front face(s) 2 X 8 SYP 2400F 2.0E with 2 row(s) of 10d (0.131"x3") nails spaced 9" o.c.except : starting at 0-7-15 from end at joint 1, nail 2 row(s) at 2" o.c. for 2-0-0; starting at 2-9-12 from end at joint 1, nail 2 row(s) at 7" o.c. for 2-0-0; starting at 10-1-0 from end at joint 1, nail 2 row(s) at 7" o.c. for 2-0-0. 2) Unbalanced roof live loads have been considered for this design. 3) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Bearing at joint(s) 1 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 11. 8) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Design assumes 4x2 (flat orientation) purlins at oc spacing indicated, fastened to truss TC w/ 2-10d nails. 10) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required. LOAD CASE(S) Standard WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/ diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage, delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from SBCA at www.sbcindustry.com. June 24,2011 10-11-7 5-3-9 19-3-8 8-4-1 27-7-9 8-4-1 32-11-2 5-3-9 38-7-0 5-7-14 39-10-4 1-3-4 10-1-2 10-1-2 0-4-10 8-7-3 0-4-10 8-7-3 9.00 12 Plate Offsets (X,Y): [2:0-3-0,Edge], [4:0-4-8,0-1-12], [7:0-4-8,0-1-12], [9:0-3-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING Plates Increase Lumber Increase Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI TC BC WB (Matrix) 0.71 1.00 0.44 DEFL Vert(LL) Vert(TL) Horz(TL) in -0.32 -0.85 0.12 (loc) 2-15 2-15 9 l/defl >999 >536 n/a L/d 240 180 n/a PLATES MT20 Weight: 155 lb FT = 20% GRIP 197/144 LUMBER TOP CHORD 2 X 4 SPF No.2 BOT CHORD 2 X 4 SPF No.2 WEBS 2 X 3 SPF No.2 *Except* W3: 2 X 4 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 3-3-8 oc purlins, except 2-0-0 oc purlins (3-7-2 max.): 4-7. BOT CHORD Structural wood sheathing directly applied. WEBS T-Brace: 2 X 4 SPF Stud - 5-13 Fasten (2X) T and I braces to narrow edge of web with 10d (0.131"x3") nails, 6in o.c.,with 3in minimum end distance. Brace must cover 90% of web length. REACTIONS (lb/size) 2=1615/0-5-8 (min. 0-2-9), 9=1615/0-5-8 (min. 0-2-9) Max Horz 2=196(LC 5) Max Uplift 2=-78(LC 6), 9=-78(LC 7) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2149/224, 3-4=-1914/230, 4-5=-1797/272, 5-6=-1796/272, 6-7=-1797/272, 7-8=-1913/230, 8-9=-2149/224 BOT CHORD 2-15=-184/1637, 14-15=-131/1464, 13-14=-131/1464, 12-13=-13/1463, 11-12=-13/1463, 9-11=-51/1638 WEBS 4-15=0/483, 4-13=-181/563, 5-13=-535/223, 7-13=-182/564, 7-11=0/484 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 9. 6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Design assumes 4x2 (flat orientation) purlins at oc spacing indicated, fastened to truss TC w/ 2-10d nails. 8) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required. LOAD CASE(S) Standard WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/ diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage, delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from SBCA at www.sbcindustry.com. June 24,2011 -1-3-4 1-3-4 6-11-14 6-11-14 13-7-7 6-7-9 19-3-8 5-8-1 24-11-9 5-8-1 31-7-2 6-7-9 38-7-0 6-11-14 39-10-4 1-3-4 10-1-2 10-1-2 0-4-10 10-7-3 0-4-10 10-7-3 9.00 12 Plate Offsets (X,Y): [2:0-8-7,0-0-10], [5:0-3-4,0-2-4], [7:0-3-4,0-2-4], [10:0-8-7,0-0-10] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING Plates Increase Lumber Increase Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI TC BC WB (Matrix) 0.51 0.95 0.29 DEFL Vert(LL) Vert(TL) Horz(TL) in -0.35 -0.94 0.12 (loc) 13-16 13-16 10 l/defl >999 >488 n/a L/d 240 180 n/a PLATES MT20 Weight: 170 lb FT = 20% GRIP 197/144 LUMBER TOP CHORD 2 X 4 SPF No.2 BOT CHORD 2 X 4 SPF No.2 WEBS 2 X 4 SPF No.2 *Except* W1,W2: 2 X 3 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 3-4-2 oc purlins, except 2-0-0 oc purlins (4-10-5 max.): 5-7. BOT CHORD Structural wood sheathing directly applied or 2-2-0 oc bracing. WEBS T-Brace: 2 X 4 SPF Stud - 3-16, 6-16, 6-13, 9-13 Fasten (2X) T and I braces to narrow edge of web with 10d (0.131"x3") nails, 6in o.c.,with 3in minimum end distance. Brace must cover 90% of web length. REACTIONS (lb/size) 2=1615/0-5-8 (min. 0-2-9), 10=1615/0-5-8 (min. 0-2-9) Max Horz 2=242(LC 5) Max Uplift 2=-91(LC 6), 10=-91(LC 7) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2206/190, 3-4=-1765/199, 4-5=-1642/243, 5-6=-1321/245, 6-7=-1321/245, 7-8=-1642/243, 8-9=-1765/199, 9-10=-2206/190 BOT CHORD 2-17=-118/1648, 16-17=-118/1648, 15-16=-57/1403, 14-15=-57/1403, 13-14=-57/1403, 12-13=-14/1648, 10-12=-14/1648 WEBS 3-16=-432/162, 5-16=-11/625, 6-16=-303/194, 6-13=-303/194, 7-13=-11/625, 9-13=-432/162 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 10. 6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Design assumes 4x2 (flat orientation) purlins at oc spacing indicated, fastened to truss TC w/ 2-10d nails. 8) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required. LOAD CASE(S) Standard WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/ diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage, delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from SBCA at www.sbcindustry.com. June 24,2011 16-3-7 7-11-9 22-3-9 6-0-3 30-3-2 7-11-9 38-7-0 8-3-14 10-1-2 10-1-2 0-4-10 12-7-3 0-4-10 12-7-3 9.00 12 Plate Offsets (X,Y): [2:0-8-7,0-0-10], [5:0-4-8,0-1-12], [6:0-4-8,0-1-12], [9:0-1-4,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING Plates Increase Lumber Increase Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI TC BC WB (Matrix) 0.85 0.77 0.56 DEFL Vert(LL) Vert(TL) Horz(TL) in -0.13 -0.39 0.12 (loc) 9-10 9-10 9 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 168 lb FT = 20% GRIP 197/144 LUMBER TOP CHORD 2 X 4 SPF No.2 BOT CHORD 2 X 4 SPF No.2 WEBS 2 X 3 SPF No.2 *Except* W3,W4: 2 X 4 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied, except 2-0-0 oc purlins (4-9-9 max.): 5-6. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS T-Brace: 2 X 4 SPF Stud - 3-13, 5-12, 8-12 Fasten (2X) T and I braces to narrow edge of web with 10d (0.131"x3") nails, 6in o.c.,with 3in minimum end distance. Brace must cover 90% of web length. REACTIONS (lb/size) 2=1617/0-5-8 (min. 0-2-9), 9=1523/0-5-8 (min. 0-2-6) Max Horz 2=299(LC 5) Max Uplift 2=-101(LC 6), 9=-52(LC 7) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2185/184, 3-4=-1618/206, 4-5=-1464/258, 5-6=-1177/265, 6-7=-1466/259, 7-8=-1619/207, 8-9=-2193/191 BOT CHORD 2-15=-70/1619, 14-15=-70/1619, 13-14=-70/1619, 12-13=-13/1176, 11-12=-41/1628, 10-11=-41/1628, 9-10=-41/1628 WEBS 3-15=0/366, 3-13=-570/185, 5-13=-31/527, 6-12=-25/529, 8-12=-580/194, 8-10=0/368 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9 except (jt=lb) 2=101. 6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Design assumes 4x2 (flat orientation) purlins at oc spacing indicated, fastened to truss TC w/ 2-10d nails. 8) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required. LOAD CASE(S) Standard WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/ diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage, delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from SBCA at www.sbcindustry.com. June 24,2011 8-3-14 16-3-7 7-11-9 22-3-9 6-0-3 30-3-2 7-11-9 38-7-0 8-3-14 39-10-4 1-3-4 10-1-2 10-1-2 0-4-10 12-7-3 0-4-10 12-7-3 9.00 12 Plate Offsets (X,Y): [2:0-8-7,0-0-10], [5:0-4-8,0-1-12], [6:0-4-8,0-1-12], [9:0-8-7,0-0-10] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING Plates Increase Lumber Increase Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI TC BC WB (Matrix) 0.81 0.71 0.55 DEFL Vert(LL) Vert(TL) Horz(TL) in -0.11 -0.36 0.12 (loc) 2-16 2-16 9 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 170 lb FT = 20% GRIP 197/144 LUMBER TOP CHORD 2 X 4 SPF No.2 BOT CHORD 2 X 4 SPF No.2 WEBS 2 X 3 SPF No.2 *Except* W3,W4: 2 X 4 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied, except 2-0-0 oc purlins (4-9-8 max.): 5-6. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS T-Brace: 2 X 4 SPF Stud - 3-14, 5-13, 8-13 Fasten (2X) T and I braces to narrow edge of web with 10d (0.131"x3") nails, 6in o.c.,with 3in minimum end distance. Brace must cover 90% of web length. REACTIONS (lb/size) 2=1615/0-5-8 (min. 0-2-9), 9=1615/0-5-8 (min. 0-2-9) Max Horz 2=-289(LC 4) Max Uplift 2=-100(LC 6), 9=-100(LC 7) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2182/182, 3-4=-1615/204, 4-5=-1461/256, 5-6=-1174/263, 6-7=-1462/256, 7-8=-1615/204, 8-9=-2182/182 BOT CHORD 2-16=-54/1617, 15-16=-54/1617, 14-15=-54/1617, 13-14=-2/1173, 12-13=0/1617, 11-12=0/1617, 9-11=0/1617 WEBS 3-16=0/366, 3-14=-570/185, 5-14=-31/527, 6-13=-25/527, 8-13=-569/185, 8-11=0/365 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 2=100, 9=100. 6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Design assumes 4x2 (flat orientation) purlins at oc spacing indicated, fastened to truss TC w/ 2-10d nails. 8) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required. LOAD CASE(S) Standard WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/ diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage, delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from SBCA at www.sbcindustry.com. June 24,2011 6x8 5x8 5x6 5x6 3x6 3x8 2x4 5x8 3x6 3x6 3x4 3x4 3x6 2x4 3x6 5x12 8x8 4x10 5x6 3x6 3x6 3x6 5x8 3-1-15 3-1-15 9-8-11 6-6-12 16-3-7 6-6-12 20-5-15 4-2-8 22-3-9 1-9-10 24-11-9 2-8-0 34-11-9 10-0-0 43-8-4 8-8-11 48-7-0 4-10-12 10-1-2 10-1-2 10-1-2 9-8-11 9-8-11 16-3-7 6-6-12 22-3-9 6-0-3 24-11-9 2-8-0 29-11-9 5-0-0 34-11-9 5-0-0 41-7-2 6-7-9 48-7-0 6-11-14 10-1-2 10-1-2 10-1-2 0-4-10 10-7-3 12-7-3 0-4-10 2-0-0 12-7-3 9.00 12 Plate Offsets (X,Y): [1:0-1-4,0-1-8], [2:0-2-11,0-0-12], [4:0-4-8,0-1-12], [6:0-6-0,0-2-0], [9:0-3-0,0-2-2], [12:0-1-4,Edge], [19:0-2-12,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING Plates Increase Lumber Increase Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI TC BC WB (Matrix) 0.79 0.94 0.99 DEFL Vert(LL) Vert(TL) Horz(TL) in -0.34 -0.88 0.66 (loc) 2-22 2-22 13 l/defl >999 >590 n/a L/d 240 180 n/a PLATES MT20 Weight: 330 lb FT = 20% GRIP 197/144 LUMBER TOP CHORD 2 X 4 SPF No.2 *Except* T1: 2 X 8 SYP 2400F 2.0E BOT CHORD 2 X 4 SPF No.2 *Except* B2: 2 X 3 SPF No.2 WEBS 2 X 4 SPF No.2 *Except* W1,W2,W6,W10,W11: 2 X 3 SPF No.2 OTHERS 2 X 8 SYP 2400F 2.0E LBR SCAB 1-3 2 X 8 SYP 2400F 2.0E one side BRACING TOP CHORD Structural wood sheathing directly applied or 3-5-2 oc purlins, except 2-0-0 oc purlins (4-3-1 max.): 4-6, 7-9. BOT CHORD Structural wood sheathing directly applied or 2-2-0 oc bracing. Except: T-Brace: 2 X 4 SPF Stud - 5-19 WEBS T-Brace: 2 X 4 SPF Stud - 3-21, 4-19, 7-17, 6-17, 11-13, 7-16, 8-15 Fasten (2X) T and I braces to narrow edge of web with 10d (0.131"x3") nails, 6in o.c.,with 3in minimum end distance. Brace must cover 90% of web length. REACTIONS (lb/size) 1=1652/0-5-8 (min. 0-2-14), 13=2963/0-5-8 (min. 0-4-10), 12=-746/0-3-8 (min. 0-1-8) Max Horz 1=286(LC 5) Max Uplift 1=-41(LC 6), 13=-56(LC 7), 12=-746(LC 1) Max Grav 1=1652(LC 1), 13=2963(LC 1), 12=117(LC 5) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-907/144, 2-24=-2721/192, 3-24=-2508/228, 3-4=-2114/281, 4-5=-1628/280, 5-6=-1617/281, 6-7=-1754/342, 7-8=-1577/277, 8-9=-892/225, 9-10=-1111/220, 10-11=-1238/177, 11-12=-129/1629 BOT CHORD 2-22=-209/2377, 21-22=-207/2381, 20-21=-130/1581, 19-20=-130/1581, 16-17=-76/1583, 15-16=-71/1303, 12-13=-1182/146 WEBS 3-22=0/310, 4-21=-40/742, 3-21=-1017/191, 4-19=-182/306, 7-17=-883/183, 6-17=-831/108, 17-19=-123/2083, 6-19=-178/1697, 9-15=-7/382, 11-15=-99/1203, 11-13=-2976/293, 7-16=-433/114, 8-16=-13/643, 8-15=-964/174 NOTES 1) Attached 12-3-1 scab 1 to 3, front face(s) 2 X 8 SYP 2400F 2.0E with 2 row(s) of 10d (0.131"x3") nails spaced 9" o.c.except : starting at 2-9-12 from end at joint 1, nail 2 row(s) at 7" o.c. for 2-0-0; starting at 10-1-0 from end at joint 1, nail 2 row(s) at 7" o.c. for 2-0-0. 2) Unbalanced roof live loads have been considered for this design. 3) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Bearing at joint(s) 1 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 13 except (jt=lb) 12=746. 8) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Design assumes 4x2 (flat orientation) purlins at oc spacing indicated, fastened to truss TC w/ 2-10d nails. 10) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required. LOAD CASE(S) Standard WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/ diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage, delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from SBCA at www.sbcindustry.com. June 24,2011 3x6 3x8 3x6 4x10 3x6 4x8 3x6 3x6 5x8 2x4 6x6 3-1-15 3-1-15 9-8-11 6-6-12 16-3-7 6-6-12 20-5-15 4-2-8 26-4-12 5-10-13 32-3-9 5-10-13 43-8-4 11-4-11 48-7-0 4-10-12 10-1-2 10-1-2 10-1-2 9-8-11 9-8-11 16-3-7 6-6-12 26-4-12 10-1-5 32-3-9 5-10-13 40-3-2 7-11-9 48-7-0 8-3-14 49-10-4 1-3-4 10-1-2 10-1-2 10-1-2 0-4-10 12-7-3 0-4-10 2-0-0 12-7-3 9.00 12 Plate Offsets (X,Y): [1:0-1-4,0-1-8], [2:0-3-12,0-2-8], [2:0-3-11,0-1-0], [4:0-6-0,0-2-0], [8:0-4-8,0-1-12], [11:0-1-6,Edge], [18:0-2-12,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING Plates Increase Lumber Increase Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI TC BC WB (Matrix) 0.87 0.96 0.93 DEFL Vert(LL) Vert(TL) Horz(TL) in -0.39 -0.99 0.59 (loc) 13-15 13-15 13 l/defl >999 >527 n/a L/d 240 180 n/a PLATES MT20 Weight: 313 lb FT = 20% GRIP 197/144 LUMBER TOP CHORD 2 X 4 SPF No.2 *Except* T2: 2 X 4 SYP 2400F 2.0E, T1: 2 X 8 SYP 2400F 2.0E BOT CHORD 2 X 4 SPF No.2 *Except* B2: 2 X 3 SPF No.2 WEBS 2 X 4 SPF No.2 *Except* W9,W6,W1,W2: 2 X 3 SPF No.2, W10: 2 X 4 SPF Stud OTHERS 2 X 8 SYP 2400F 2.0E LBR SCAB 1-3 2 X 8 SYP 2400F 2.0E one side WEDGE Right: 2 X 4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 4-1-9 oc purlins, except 2-0-0 oc purlins (4-3-0 max.): 4-8. BOT CHORD Structural wood sheathing directly applied or 2-2-0 oc bracing. Except: T-Brace: 2 X 4 SPF Stud - 5-18 WEBS T-Brace: 2 X 4 SPF Stud - 6-16, 8-15, 8-16, 3-20 2 X 6 SPF No.2 - 10-13 Fasten (2X) T and I braces to narrow edge of web with 10d (0.131"x3") nails, 6in o.c.,with 3in minimum end distance. Brace must cover 90% of web length. REACTIONS (lb/size) 1=1679/0-5-8 (min. 0-2-15), 13=2687/0-5-8 (min. 0-4-3), 11=-412/0-3-8 (min. 0-1-8) Max Horz 1=-299(LC 4) Max Uplift 1=-44(LC 6), 11=-571(LC 10) Max Grav 1=1679(LC 1), 13=2687(LC 1), 11=91(LC 5) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-921/173, 2-23=-2782/197, 3-23=-2569/231, 3-4=-2168/286, 4-5=-1694/289, 5-6=-1693/291, 6-7=-1333/303, 7-8=-1334/303, 8-9=-1303/272, 9-10=-1454/220, 10-11=-108/1270 BOT CHORD 2-21=-243/2434, 20-21=-241/2437, 19-20=-158/1619, 18-19=-158/1619, 5-18=-313/140, 15-16=-11/1038, 14-15=-52/529, 13-14=-52/529, 11-13=-882/151 WEBS 6-16=-1021/272, 8-15=-297/187, 10-15=-112/803, 10-13=-2769/270, 8-16=-203/777, 16-18=-117/1349, 6-18=-116/749, 4-20=-41/747, 4-18=-236/364, 3-21=0/311, 3-20=-1041/191 NOTES 1) Attached 12-3-1 scab 1 to 3, front face(s) 2 X 8 SYP 2400F 2.0E with 2 row(s) of 10d (0.131"x3") nails spaced 9" o.c.except : starting at 2-9-12 from end at joint 1, nail 2 row(s) at 4" o.c. for 2-0-0; starting at 10-1-0 from end at joint 1, nail 2 row(s) at 7" o.c. for 2-0-0. 2) Unbalanced roof live loads have been considered for this design. 3) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Bearing at joint(s) 1 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1 except (jt=lb) 11=571. 8) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Design assumes 4x2 (flat orientation) purlins at oc spacing indicated, fastened to truss TC w/ 2-10d nails. 10) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required. LOAD CASE(S) Standard WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/ diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage, delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from SBCA at www.sbcindustry.com. June 24,2011 16-3-7 7-11-9 24-3-8 8-0-1 32-3-9 8-0-1 40-3-2 7-11-9 48-7-0 8-3-14 10-1-2 10-1-2 -1-3-4 1-3-4 8-3-14 8-3-14 16-3-7 7-11-9 24-3-8 8-0-1 32-3-9 8-0-1 40-3-2 7-11-9 48-7-0 8-3-14 10-1-2 10-1-2 0-4-10 12-7-3 0-4-10 12-7-3 9.00 12 Plate Offsets (X,Y): [2:0-10-11,0-0-14], [5:0-10-8,0-1-12], [8:0-10-8,0-1-12], [11:0-10-11,0-0-14] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING Plates Increase Lumber Increase Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI TC BC WB (Matrix) 0.76 0.86 0.54 DEFL Vert(LL) Vert(TL) Horz(TL) in -0.14 -0.42 0.20 (loc) 16 11-12 11 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 MT18H Weight: 231 lb FT = 20% GRIP 197/144 197/144 LUMBER TOP CHORD 2 X 4 SPF No.2 *Except* T1,T5: 2 X 4 SYP No.1 BOT CHORD 2 X 4 SPF No.2 WEBS 2 X 4 SPF No.2 *Except* W1,W2: 2 X 3 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied, except 2-0-0 oc purlins (3-8-2 max.): 5-8. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS T-Brace: 2 X 4 SPF Stud - 3-17, 5-16, 6-16, 8-16, 10-14 Fasten (2X) T and I braces to narrow edge of web with 10d (0.131"x3") nails, 6in o.c.,with 3in minimum end distance. Brace must cover 90% of web length. REACTIONS (lb/size) 2=2016/0-5-8 (min. 0-3-3), 11=1924/0-5-8 (min. 0-3-0) Max Horz 2=299(LC 5) Max Uplift 2=-98(LC 6), 11=-50(LC 7) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2830/246, 3-4=-2275/267, 4-5=-2017/319, 5-6=-1914/332, 6-7=-1913/332, 7-8=-1914/332, 8-9=-2129/321, 9-10=-2278/269, 10-11=-2840/254 BOT CHORD 2-19=-176/2129, 18-19=-176/2129, 17-18=-176/2129, 16-17=-126/1706, 15-16=0/1707, 14-15=0/1707, 13-14=-90/2139, 12-13=-90/2139, 11-12=-90/2139 WEBS 3-19=0/352, 3-17=-547/187, 5-17=-17/566, 5-16=-198/526, 6-16=-496/219, 8-16=-198/525, 8-14=-21/569, 10-14=-559/196, 10-12=0/355 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 11. 7) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Design assumes 4x2 (flat orientation) purlins at oc spacing indicated, fastened to truss TC w/ 2-10d nails. 9) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required. LOAD CASE(S) Standard WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/ diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage, delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from SBCA at www.sbcindustry.com. June 24,2011 7-11-9 24-3-8 8-0-1 32-3-9 8-0-1 40-3-2 7-11-9 48-7-0 8-3-14 10-1-2 10-1-2 8-3-14 8-3-14 16-3-7 7-11-9 24-3-8 8-0-1 32-3-9 8-0-1 40-3-2 7-11-9 48-7-0 8-3-14 10-1-2 10-1-2 0-4-10 12-7-3 0-4-10 12-7-3 9.00 12 Plate Offsets (X,Y): [1:0-10-11,0-0-14], [4:0-10-8,0-1-12], [7:0-10-8,0-1-12], [10:0-10-11,0-0-14] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING Plates Increase Lumber Increase Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI TC BC WB (Matrix) 0.76 0.86 0.54 DEFL Vert(LL) Vert(TL) Horz(TL) in -0.14 -0.42 0.20 (loc) 15 1-18 10 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 MT18H Weight: 229 lb FT = 20% GRIP 197/144 197/144 LUMBER TOP CHORD 2 X 4 SPF No.2 *Except* T1: 2 X 4 SYP No.1 BOT CHORD 2 X 4 SPF No.2 WEBS 2 X 4 SPF No.2 *Except* W1,W2: 2 X 3 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied, except 2-0-0 oc purlins (3-8-1 max.): 4-7. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 2-16, 4-15, 5-15, 7-15, 9-13 REACTIONS (lb/size) 1=1925/0-5-8 (min. 0-3-0), 10=1925/0-5-8 (min. 0-3-0) Max Horz 1=286(LC 5) Max Uplift 1=-50(LC 6), 10=-50(LC 7) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-2842/256, 2-3=-2280/271, 3-4=-2022/323, 4-5=-1916/334, 5-6=-1916/335, 6-7=-1917/335, 7-8=-2132/323, 8-9=-2280/271, 9-10=-2842/256 BOT CHORD 1-18=-178/2141, 17-18=-178/2141, 16-17=-178/2141, 15-16=-126/1709, 14-15=0/1709, 13-14=0/1709, 12-13=-92/2141, 11-12=-92/2141, 10-11=-92/2141 WEBS 2-18=0/355, 2-16=-558/195, 4-16=-20/568, 4-15=-198/526, 5-15=-497/219, 7-15=-198/527, 7-13=-21/569, 9-13=-559/196, 9-11=0/355 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 10. 7) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Design assumes 4x2 (flat orientation) purlins at oc spacing indicated, fastened to truss TC w/ 2-10d nails. LOAD CASE(S) Standard WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/ diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage, delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from SBCA at www.sbcindustry.com. June 24,2011 7-11-9 24-3-8 8-0-1 32-3-9 8-0-1 40-3-2 7-11-9 48-7-0 8-3-14 10-1-2 10-1-2 8-3-14 8-3-14 16-3-7 7-11-9 24-3-8 8-0-1 32-3-9 8-0-1 40-3-2 7-11-9 48-7-0 8-3-14 49-10-4 1-3-4 10-1-2 10-1-2 0-4-10 12-7-3 0-4-10 12-7-3 9.00 12 Plate Offsets (X,Y): [1:0-10-11,0-0-14], [4:0-10-8,0-1-12], [7:0-10-8,0-1-12], [10:0-10-11,0-0-14] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING Plates Increase Lumber Increase Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI TC BC WB (Matrix) 0.76 0.86 0.54 DEFL Vert(LL) Vert(TL) Horz(TL) in -0.14 -0.42 0.20 (loc) 16 1-19 10 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 MT18H Weight: 231 lb FT = 20% GRIP 197/144 197/144 LUMBER TOP CHORD 2 X 4 SPF No.2 *Except* T1,T5: 2 X 4 SYP No.1 BOT CHORD 2 X 4 SPF No.2 WEBS 2 X 4 SPF No.2 *Except* W1,W2: 2 X 3 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied, except 2-0-0 oc purlins (3-8-2 max.): 4-7. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS T-Brace: 2 X 4 SPF Stud - 2-17, 4-16, 5-16, 7-16, 9-14 Fasten (2X) T and I braces to narrow edge of web with 10d (0.131"x3") nails, 6in o.c.,with 3in minimum end distance. Brace must cover 90% of web length. REACTIONS (lb/size) 1=1924/0-5-8 (min. 0-3-0), 10=2016/0-5-8 (min. 0-3-3) Max Horz 1=-299(LC 4) Max Uplift 1=-50(LC 6), 10=-98(LC 7) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-2840/254, 2-3=-2278/269, 3-4=-2020/321, 4-5=-1914/332, 5-6=-1913/332, 6-7=-1914/332, 7-8=-2128/319, 8-9=-2275/267, 9-10=-2831/246 BOT CHORD 1-19=-167/2139, 18-19=-167/2139, 17-18=-167/2139, 16-17=-115/1708, 15-16=0/1705, 14-15=0/1705, 13-14=-42/2130, 12-13=-42/2130, 10-12=-42/2130 WEBS 2-19=0/355, 2-17=-558/195, 4-17=-20/568, 4-16=-198/524, 5-16=-496/219, 7-16=-199/527, 7-14=-17/567, 9-14=-549/187, 9-12=0/352 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 10. 7) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Design assumes 4x2 (flat orientation) purlins at oc spacing indicated, fastened to truss TC w/ 2-10d nails. 9) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required. LOAD CASE(S) Standard WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/ diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage, delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from SBCA at www.sbcindustry.com. June 24,2011 32-3-9 8-0-1 43-8-4 11-4-11 48-7-0 4-10-12 10-1-2 10-1-2 10-1-2 8-3-14 8-3-14 16-3-7 7-11-9 24-3-8 8-0-1 32-3-9 8-0-1 40-3-2 7-11-9 48-7-0 8-3-14 49-10-4 1-3-4 10-1-2 10-1-2 10-1-2 0-4-10 12-7-3 0-4-10 12-7-3 9.00 12 Plate Offsets (X,Y): [1:0-8-7,0-0-6], [4:0-6-0,0-1-4], [7:1-0-8,0-1-12], [10:0-1-4,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING Plates Increase Lumber Increase Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI TC BC WB (Matrix) 0.67 0.96 0.98 DEFL Vert(LL) Vert(TL) Horz(TL) in -0.37 -0.92 0.13 (loc) 12-14 12-14 12 l/defl >999 >568 n/a L/d 240 180 n/a PLATES MT20 MT18H Weight: 227 lb FT = 20% GRIP 197/144 197/144 LUMBER TOP CHORD 2 X 4 SPF No.2 *Except* T1: 2 X 4 SYP No.1 BOT CHORD 2 X 4 SPF No.2 WEBS 2 X 4 SPF No.2 *Except* W1,W2,W5,W6: 2 X 3 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 3-1-7 oc purlins, except 2-0-0 oc purlins (4-2-2 max.): 4-7. BOT CHORD Structural wood sheathing directly applied or 2-2-0 oc bracing. WEBS T-Brace: 2 X 4 SPF Stud - 2-17, 4-16, 5-16, 7-16, 7-14, 9-12 Fasten (2X) T and I braces to narrow edge of web with 10d (0.131"x3") nails, 6in o.c.,with 3in minimum end distance. Brace must cover 90% of web length. REACTIONS (lb/size) 1=1733/0-5-8 (min. 0-2-11), 12=2007/0-5-8 (min. 0-3-2), 10=202/0-3-8 (min. 0-1-8) Max Horz 1=-299(LC 4) Max Uplift 1=-54(LC 6), 10=-109(LC 7) Max Grav 1=1733(LC 1), 12=2007(LC 1), 10=232(LC 11) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-2529/238, 2-3=-1966/253, 3-4=-1713/305, 4-5=-1539/314, 5-6=-1538/315, 6-7=-1540/315, 7-8=-1521/282, 8-9=-1667/230, 9-10=-77/270 BOT CHORD 1-19=-193/1894, 18-19=-193/1894, 17-18=-193/1894, 16-17=-141/1459, 15-16=-28/1215, 14-15=-28/1215, 13-14=-1/880, 12-13=-1/880 WEBS 2-19=0/353, 2-17=-562/196, 4-17=-18/579, 4-16=-213/310, 5-16=-498/220, 7-16=-185/690, 9-14=-92/520, 9-12=-1995/230 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1 except (jt=lb) 10=109. 7) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Design assumes 4x2 (flat orientation) purlins at oc spacing indicated, fastened to truss TC w/ 2-10d nails. 9) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required. LOAD CASE(S) Standard TRUSS NOT SYMMETRIC DO NOT ERECT THE TRUSS BACKWARDS WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/ diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage, delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from SBCA at www.sbcindustry.com. June 24,2011 8-0-1 32-3-9 8-0-1 43-8-4 11-4-11 48-7-0 4-10-12 10-1-2 10-1-2 10-1-2 -1-3-4 1-3-4 8-3-14 8-3-14 16-3-7 7-11-9 24-3-8 8-0-1 32-3-9 8-0-1 40-3-2 7-11-9 48-7-0 8-3-14 49-10-4 1-3-4 10-1-2 10-1-2 10-1-2 0-4-10 12-7-3 0-4-10 12-7-3 9.00 12 Plate Offsets (X,Y): [2:0-1-4,Edge], [5:0-6-0,0-1-4], [8:1-0-8,0-1-12], [11:0-1-4,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING Plates Increase Lumber Increase Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI TC BC WB (Matrix) 0.97 0.96 0.99 DEFL Vert(LL) Vert(TL) Horz(TL) in -0.37 -0.92 0.13 (loc) 13-15 13-15 13 l/defl >999 >567 n/a L/d 240 180 n/a PLATES MT20 MT18H Weight: 224 lb FT = 20% GRIP 197/144 197/144 LUMBER TOP CHORD 2 X 4 SPF No.2 BOT CHORD 2 X 4 SPF No.2 WEBS 2 X 4 SPF No.2 *Except* W1,W2,W5,W6: 2 X 3 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied, except 2-0-0 oc purlins (4-2-5 max.): 5-8. BOT CHORD Structural wood sheathing directly applied or 2-2-0 oc bracing. WEBS T-Brace: 2 X 4 SPF Stud - 3-18, 5-17, 6-17, 8-17, 8-15, 10-13 Fasten (2X) T and I braces to narrow edge of web with 10d (0.131"x3") nails, 6in o.c.,with 3in minimum end distance. Brace must cover 90% of web length. REACTIONS (lb/size) 2=1823/0-5-8 (min. 0-2-14), 13=2019/0-5-8 (min. 0-3-3), 11=189/0-3-8 (min. 0-1-8) Max Horz 2=-289(LC 4) Max Uplift 2=-102(LC 6), 11=-109(LC 7) Max Grav 2=1823(LC 1), 13=2019(LC 1), 11=222(LC 11) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2517/229, 3-4=-1959/249, 4-5=-1813/300, 5-6=-1534/312, 6-7=-1533/312, 7-8=-1535/312, 8-9=-1515/281, 9-10=-1661/229, 10-11=-62/291 BOT CHORD 2-20=-191/1880, 19-20=-191/1880, 18-19=-191/1880, 17-18=-141/1454, 16-17=-27/1210, 15-16=-27/1210, 14-15=0/871, 13-14=0/871 WEBS 3-20=0/353, 3-18=-550/186, 5-18=-13/576, 5-17=-213/310, 6-17=-497/220, 8-17=-185/689, 10-15=-92/525, 10-13=-2009/230 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 2=102, 11=109. 7) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Design assumes 4x2 (flat orientation) purlins at oc spacing indicated, fastened to truss TC w/ 2-10d nails. 9) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required. LOAD CASE(S) Standard TRUSS NOT SYMMETRIC DO NOT ERECT THE TRUSS BACKWARDS WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/ diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage, delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from SBCA at www.sbcindustry.com. June 24,2011 0.15 0.00 DEFL Vert(LL) Vert(TL) Horz(TL) in -0.01 -0.03 0.00 (loc) 2-4 2-4 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 15 lb FT = 20% GRIP 197/144 LUMBER TOP CHORD 2 X 4 SPF No.2 BOT CHORD 2 X 4 SPF No.2 WEBS 2 X 3 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 4=134/Mechanical, 2=251/0-3-8 (min. 0-1-8) Max Horz 2=101(LC 5) Max Uplift 4=-22(LC 5), 2=-52(LC 6) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 2. 5) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/ diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage, delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from SBCA at www.sbcindustry.com. June 24,2011 0.51 0.34 0.00 DEFL Vert(LL) Vert(TL) Horz(TL) in 0.00 0.08 0.00 (loc) 1 1 4 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 26 lb FT = 20% GRIP 197/144 LUMBER TOP CHORD 2 X 4 SPF No.2 BOT CHORD 2 X 4 SPF No.2 WEBS 2 X 4 SPF Stud WEDGE Left: 2 X 4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 5-10-12 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 4=222/5-10-12 (min. 0-1-8), 2=315/5-10-12 (min. 0-1-8) Max Horz 2=196(LC 5) Max Uplift 4=-78(LC 5), 2=-17(LC 6) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 2. 5) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/ diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage, delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from SBCA at www.sbcindustry.com. June 24,2011 0.51 0.34 0.00 DEFL Vert(LL) Vert(TL) Horz(TL) in -0.07 -0.16 0.00 (loc) 2-4 2-4 4 l/defl >999 >421 n/a L/d 240 180 n/a PLATES MT20 Weight: 27 lb FT = 20% GRIP 197/144 LUMBER TOP CHORD 2 X 4 SPF No.2 BOT CHORD 2 X 4 SPF No.2 WEBS 2 X 4 SPF Stud WEDGE Left: 2 X 8 SYP 2400F 2.0E BRACING TOP CHORD Structural wood sheathing directly applied or 5-10-12 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 4=222/Mechanical, 2=315/0-5-8 (min. 0-1-8) Max Horz 2=196(LC 5) Max Uplift 4=-78(LC 5), 2=-17(LC 6) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 2. 5) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/ diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage, delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from SBCA at www.sbcindustry.com. June 24,2011 WB (Matrix) 0.12 0.01 0.00 DEFL Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 -0.00 (loc) 2 2 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 7 lb FT = 20% GRIP 197/144 LUMBER TOP CHORD 2 X 4 SPF No.2 BOT CHORD 2 X 4 SPF No.2 WEDGE Left: 2 X 6 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 1-2-6 oc purlins. BOT CHORD Structural wood sheathing directly applied or 6-0-0 oc bracing. REACTIONS (lb/size) 2=164/0-3-8 (min. 0-1-8), 3=-10/Mechanical, 6=14/Mechanical Max Horz 2=87(LC 6) Max Uplift 2=-50(LC 6), 3=-19(LC 7) Max Grav 2=164(LC 1), 3=19(LC 4), 6=29(LC 2) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 3. 5) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/ diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage, delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from SBCA at www.sbcindustry.com. June 24,2011 BC WB (Matrix) 0.12 0.01 0.00 DEFL Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 -0.00 (loc) 2 2 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 6 lb FT = 20% GRIP 197/144 LUMBER TOP CHORD 2 X 4 SPF No.2 BOT CHORD 2 X 4 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 1-4-12 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 2=168/0-3-8 (min. 0-1-8), 3=-2/Mechanical, 6=16/Mechanical Max Horz 2=72(LC 6) Max Uplift 2=-66(LC 6), 3=-8(LC 7) Max Grav 2=168(LC 1), 3=18(LC 4), 6=32(LC 2) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 3. 5) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/ diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage, delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from SBCA at www.sbcindustry.com. June 24,2011 0.12 0.01 0.00 DEFL Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 -0.00 (loc) 2 2 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 7 lb FT = 20% GRIP 197/144 LUMBER TOP CHORD 2 X 4 SPF No.2 BOT CHORD 2 X 4 SPF No.2 WEDGE Left: 2 X 6 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 1-2-6 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 2=165/0-3-8 (min. 0-1-8), 5=12/Mechanical, 3=-10/Mechanical Max Horz 2=87(LC 6) Max Uplift 2=-49(LC 6), 3=-19(LC 7) Max Grav 2=165(LC 1), 5=24(LC 2), 3=19(LC 4) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 3. 5) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/ diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage, delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from SBCA at www.sbcindustry.com. June 24,2011 BC WB (Matrix) 0.12 0.01 0.00 DEFL Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 -0.00 (loc) 2 2 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 6 lb FT = 20% GRIP 197/144 LUMBER TOP CHORD 2 X 4 SPF No.2 BOT CHORD 2 X 4 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 1-4-12 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 2=168/0-3-8 (min. 0-1-8), 3=-2/Mechanical, 6=16/Mechanical Max Horz 2=72(LC 6) Max Uplift 2=-66(LC 6), 3=-8(LC 7) Max Grav 2=168(LC 1), 3=18(LC 4), 6=32(LC 2) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 3. 5) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/ diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage, delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from SBCA at www.sbcindustry.com. June 24,2011 WB (Matrix) 0.16 0.04 0.00 DEFL Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 -0.00 (loc) 2 2-4 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 8 lb FT = 20% GRIP 197/144 LUMBER TOP CHORD 2 X 4 SPF No.2 BOT CHORD 2 X 4 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 2-3-7 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 3=26/Mechanical, 2=204/0-5-8 (min. 0-1-8), 4=29/Mechanical Max Horz 2=92(LC 5) Max Uplift 3=-19(LC 6), 2=-57(LC 5) Max Grav 3=26(LC 1), 2=204(LC 1), 4=77(LC 2) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 2. 5) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 37 lb down and 11 lb up at 2-2-11 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Regular: Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-3=-60, 2-4=-20 Concentrated Loads (lb) Vert: 4=-9(B) WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/ diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage, delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from SBCA at www.sbcindustry.com. June 24,2011 10-1-2 10-1-2 0-8-7 3-4-10 0-8-7 3-4-10 12.00 12 Plate Offsets (X,Y): [2:0-4-0,0-0-15], [3:0-4-4,0-1-12], [5:0-4-4,0-1-12], [6:0-4-0,0-0-15] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING Plates Increase Lumber Increase Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI TC BC WB (Matrix) 0.30 0.30 0.27 DEFL Vert(LL) Vert(TL) Horz(TL) in -0.04 -0.09 0.02 (loc) 8-9 8-9 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 71 lb FT = 20% GRIP 197/144 LUMBER TOP CHORD 2 X 4 SPF No.2 BOT CHORD 2 X 6 SPF No.2 WEBS 2 X 3 SPF No.2 WEDGE Left: 2 X 4 SPF Stud, Right: 2 X 4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 4-10-3 oc purlins, except 2-0-0 oc purlins (4-7-4 max.): 3-5. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 2=1085/0-3-8 (min. 0-1-11), 6=1139/0-3-8 (min. 0-1-13) Max Horz 2=-73(LC 3) Max Uplift 2=-161(LC 4), 6=-177(LC 3) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1265/231, 3-4=-1495/308, 4-5=-1495/308, 5-6=-1340/253 BOT CHORD 2-10=-175/810, 10-11=-175/820, 11-12=-175/820, 9-12=-175/820, 9-13=-147/871, 13-14=-147/871, 14-15=-147/871, 8-15=-147/871, 6-8=-146/858 WEBS 3-10=-19/303, 3-9=-195/787, 4-9=-319/136, 5-9=-179/728, 5-8=-44/388 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 2=161, 6=177. 6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Design assumes 4x2 (flat orientation) purlins at oc spacing indicated, fastened to truss TC w/ 2-10d nails. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 114 lb down and 34 lb up at 2-8-15, 114 lb down and 34 lb up at 4-8-15, 114 lb down and 34 lb up at 6-8-15, 114 lb down and 34 lb up at 8-8-15, 114 lb down and 34 lb up at 10-8-15, and 114 lb down and 34 lb up at 12-8-15, and 114 lb down and 34 lb up at 13-3-1 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Regular: Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-3=-60, 3-5=-60, 5-7=-60, 2-6=-20 Concentrated Loads (lb) Vert: 10=-114(B) 8=-114(B) 11=-114(B) 12=-114(B) 13=-114(B) 14=-114(B) 15=-114(B) WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/ diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage, delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from SBCA at www.sbcindustry.com. June 24,2011 10.0 SPACING Plates Increase Lumber Increase Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI TC BC WB (Matrix) 0.28 0.14 0.09 DEFL Vert(LL) Vert(TL) Horz(TL) in -0.01 -0.01 0.00 (loc) 5-6 5-6 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 27 lb FT = 20% GRIP 197/144 LUMBER TOP CHORD 2 X 4 SPF No.2 BOT CHORD 2 X 6 SPF No.2 WEBS 2 X 3 SPF No.2 WEDGE Left: 2 X 6 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 5-10-12 oc purlins, except end verticals, and 2-0-0 oc purlins: 3-4. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. JOINTS 1 Brace at Jt(s): 4 REACTIONS (lb/size) 5=166/Mechanical, 2=292/0-5-8 (min. 0-1-8) Max Horz 2=69(LC 5) Max Uplift 5=-8(LC 4), 2=-56(LC 5) Max Grav 5=207(LC 2), 2=292(LC 1) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-269/0 NOTES 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 2. 6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Design assumes 4x2 (flat orientation) purlins at oc spacing indicated, fastened to truss TC w/ 2-10d nails. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 5 lb down and 34 lb up at 1-4-12, and 5 lb down and 34 lb up at 3-5-8, and 5 lb down and 34 lb up at 5-5-8 on top chord, and 37 lb down at 1-5-8, and 37 lb down at 3-5-8, and 37 lb down at 5-5-8 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Regular: Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-3=-60, 3-4=-60, 2-5=-20 Concentrated Loads (lb) Vert: 3=34(F) 6=-9(F) 7=34(F) 8=34(F) 9=-9(F) 10=-9(F) WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/ diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage, delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from SBCA at www.sbcindustry.com. June 24,2011 13-2-10 4-11-3 18-3-1 5-0-7 23-3-8 5-0-7 28-3-15 5-0-7 33-4-7 5-0-7 38-4-14 5-0-7 43-5-5 5-0-7 47-4-3 3-10-14 48-7-0 1-2-13 10-1-2 10-1-2 -1-3-4 1-3-4 4-5-3 4-5-3 8-3-7 3-10-3 13-2-10 4-11-3 18-3-1 5-0-7 23-3-8 5-0-7 28-3-15 5-0-7 33-4-7 5-0-7 38-4-14 5-0-7 43-5-5 5-0-7 48-7-0 5-1-11 10-1-2 10-1-2 0-4-10 6-7-3 9.00 12 Plate Offsets (X,Y): [2:0-3-6,0-2-4], [4:0-3-12,0-1-12], [15:Edge,0-2-8], [26:0-2-8,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING Plates Increase Lumber Increase Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI TC BC WB (Matrix) 0.83 0.84 0.91 DEFL Vert(LL) Vert(TL) Horz(TL) in 0.34 -0.73 0.18 (loc) 21-22 21-22 15 l/defl >999 >789 n/a L/d 240 180 n/a PLATES MT20 Weight: 530 lb FT = 20% GRIP 197/144 LUMBER TOP CHORD 2 X 4 SPF No.2 BOT CHORD 2 X 6 SPF No.2 WEBS 2 X 3 SPF No.2 *Except* W4: 2 X 4 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 4-9-5 oc purlins, except end verticals, and 2-0-0 oc purlins (4-0-2 max.): 4-14. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS T-Brace: 2 X 4 SPF Stud - 14-15 Fasten (2X) T and I braces to narrow edge of web with 10d (0.131"x3") nails, 6in o.c.,with 3in minimum end distance. Brace must cover 90% of web length. JOINTS 1 Brace at Jt(s): 14 REACTIONS (lb/size) 15=4441/0-5-8 (min. 0-3-8), 2=4294/0-5-8 (min. 0-3-6) Max Horz 2=201(LC 4) Max Uplift 15=-1374(LC 3), 2=-971(LC 4) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-6442/1571, 3-4=-6018/1610, 4-5=-6676/1930, 5-6=-6675/1930, 6-7=-8467/2567, 7-8=-8467/2567, 8-9=-8467/2567, 9-10=-7324/2276, 10-11=-7324/2276, 11-12=-3243/1056, 12-13=-3243/1056, 13-14=-3243/1056, 14-15=-4117/1292 BOT CHORD 2-28=-1381/5004, 27-28=-1381/5004, 27-29=-1381/5004, 26-29=-1381/5004, 26-30=-1364/4746, 30-31=-1364/4746, 25-31=-1364/4746, 25-32=-2291/7946, 24-32=-2291/7946, 24-33=-2291/7946, 23-33=-2291/7946, 23-34=-2291/7946, 34-35=-2291/7946, 22-35=-2291/7946, 22-36=-2420/8265, 36-37=-2420/8265, 21-37=-2420/8265, 20-21=-2420/8265, 20-38=-2420/8265, 19-38=-2420/8265, 18-19=-2420/8265, 18-39=-1663/5651, 39-40=-1663/5651, 17-40=-1663/5651, 17-41=-1663/5651, 41-42=-1663/5651, 16-42=-1663/5651 WEBS 3-27=-18/372, 3-26=-325/95, 4-26=-227/845, 4-25=-1045/3101, 5-25=-262/119, 6-25=-2019/695, 6-23=-169/611, 6-22=-317/829, 7-22=-291/119, 9-22=-85/321, 9-21=-164/600, 9-18=-1496/419, 10-18=-293/118, 11-18=-785/2660, 11-17=-166/602, 11-16=-3828/1155, 13-16=-314/113, 14-16=-1575/5116 NOTES 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2 X 4 - 1 row at 0-9-0 oc, 2 X 3 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2 X 6 - 2 rows at 0-9-0 oc. Webs connected as follows: 2 X 3 - 1 row at 0-9-0 oc, 2 X 4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 15=1374, 2=971. 7) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Design assumes 4x2 (flat orientation) purlins at oc spacing indicated, fastened to truss TC w/ 2-10d nails. Continued on page 2 WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/ diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage, delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from SBCA at www.sbcindustry.com. June 24,2011 1-11-0 8-3-7 1-11-4 12-7-8 4-4-1 17-0-13 4-5-5 21-6-3 4-5-5 25-11-8 4-5-5 30-2-13 4-3-5 30-3-9 0-0-12 32-2-13 1-11-4 34-1-13 1-11-0 34-2-13 0-1-0 36-2-13 2-0-0 38-7-0 2-4-3 10-1-2 10-1-2 -1-3-4 1-3-4 4-5-3 4-5-3 8-3-7 3-10-3 12-7-8 4-4-1 17-0-13 4-5-5 21-6-3 4-5-5 25-11-8 4-5-5 30-3-9 4-4-1 34-1-13 3-10-3 38-7-0 4-5-3 39-10-4 1-3-4 10-1-2 10-1-2 0-4-10 6-7-3 0-4-10 6-7-3 9.00 12 Plate Offsets (X,Y): [2:0-4-2,0-2-12], [4:0-7-12,0-1-12], [9:0-2-8,0-2-0], [10:0-7-12,0-1-12], [12:0-4-2,0-2-12], [15:0-2-8,0-2-0], [16:0-2-8,0-3-0], [22:0-2-8,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING Plates Increase Lumber Increase Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI TC BC WB (Matrix) 0.89 0.73 0.98 DEFL Vert(LL) Vert(TL) Horz(TL) in 0.30 -0.67 0.17 (loc) 18-19 18-19 12 l/defl >999 >688 n/a L/d 240 180 n/a PLATES MT20 MT18H Weight: 215 lb FT = 20% GRIP 197/144 197/144 LUMBER TOP CHORD 2 X 4 SPF No.2 BOT CHORD 2 X 6 SYP No.1 WEBS 2 X 3 SPF No.2 WEDGE Left: 2 X 6 SPF No.2, Right: 2 X 6 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 2-2-10 oc purlins, except 2-0-0 oc purlins (2-2-0 max.): 4-10. BOT CHORD Structural wood sheathing directly applied or 6-8-8 oc bracing. WEBS T-Brace: 2 X 4 SPF Stud - 6-21 Fasten (2X) T and I braces to narrow edge of web with 10d (0.131"x3") nails, 6in o.c.,with 3in minimum end distance. Brace must cover 90% of web length. REACTIONS (lb/size) 2=3371/0-5-8 (min. 0-4-0), 12=3383/0-5-8 (min. 0-4-0) Max Horz 2=148(LC 4) Max Uplift 2=-757(LC 4), 12=-762(LC 3) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-4963/1216, 3-4=-4512/1224, 4-5=-4633/1322, 5-6=-4632/1322, 6-7=-5206/1482, 7-8=-5206/1482, 8-9=-5206/1482, 9-10=-4653/1330, 10-11=-4531/1233, 11-12=-4981/1225 BOT CHORD 2-24=-1041/3841, 23-24=-1041/3841, 23-25=-1041/3841, 22-25=-1041/3841, 22-26=-1000/3540, 21-26=-1000/3540, 21-27=-1489/5216, 20-27=-1489/5216, 20-28=-1489/5216, 19-28=-1489/5216, 19-29=-1489/5216, 29-30=-1489/5216, 18-30=-1489/5216, 17-18=-1268/4653, 17-31=-1268/4653, 16-31=-1268/4653, 16-32=-893/3556, 32-33=-893/3556, 15-33=-893/3556, 15-34=-900/3855, 14-34=-900/3855, 14-35=-900/3855, 12-35=-900/3855 WEBS 3-23=-25/393, 3-22=-385/111, 4-22=-219/830, 4-21=-650/1953, 6-21=-1043/358, 6-19=-155/554, 7-18=-264/107, 9-18=-337/991, 9-16=-1051/382, 10-16=-653/1963, 10-15=-224/834, 11-15=-383/110, 11-14=-24/392 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) The Fabrication Tolerance at joint 4 = 16%, joint 10 = 16% 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 2=757, 12=762. 8) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Design assumes 4x2 (flat orientation) purlins at oc spacing indicated, fastened to truss TC w/ 2-10d nails. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 167 lb down and 20 lb up at 2-4-3, 203 lb down and 50 lb up at 4-4-3, 203 lb down and 69 lb up at 6-4-3, 202 lb down and 90 lb up at 8-4-3, 202 lb down and 90 lb up at 10-4-3, 202 lb down and 90 lb up at 12-4-3, 202 lb down and 90 lb up at 14-4-3, 202 lb down and 90 lb up at 16-4-3, 202 lb down and 90 lb up at 18-4-3, 202 lb down and 90 lb up at 20-4-3, 202 lb down and 90 lb up at 22-4-3, 202 lb down and 90 lb up at 24-4-3, 202 lb down and 90 lb up at 26-4-3, 202 lb down and 90 lb up at 28-4-3, 202 lb down and 90 lb up at 30-2-13, 203 lb down and 69 lb up at 32-2-13, and 203 lb down and 50 lb up at 34-2-13, and 167 lb down and 20 lb up at 36-2-13 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 11) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required. 12) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard Continued on page 2 WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/ diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage, delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from SBCA at www.sbcindustry.com. June 24,2011 2. CONNECTION BETWEEN BOTTOM CHORD OF GABLE END TRUSS AND WALL TO BE PROVIDED BY PROJECT ENGINEER OR ARCHITECT. 3. BRACING SHOWN IS FOR INDIVIDUAL TRUSS ONLY. CONSULT BLDG. ARCHITECT OR ENGINEER FOR TEMPORARY AND PERMANENT BRACING OF ROOF SYSTEM. 4. "L" BRACES SPECIFIED ARE TO BE FULL LENGTH. GRADES: 1x4 SRB OR 2x4 STUD OR BETTER WITH ONE ROW OF 10d NAILS SPACED 6" O.C. 5. DIAGONAL BRACE TO BE APPROXIMATELY 45 DEGREES TO ROOF DIAPHRAM AT 4’-0" O.C. 6. CONSTRUCT HORIZONTAL BRACE CONNECTING A 2x6 STUD (or 2X4 No.2 OR BETTER) AND A 2x4 STUD AS SHOWN WITH 16d NAILS SPACED 6" O.C. HORIZONTAL BRACE TO BE LOCATED AT THE MIDSPAN OF THE LONGEST STUD. ATTACH TO VERTICAL STUDS WITH (4) 10d NAILS THROUGH 2x4. (REFER TO SECTION A-A) 7. GABLE STUD DEFLECTION MEETS OR EXCEEDS L/240. 8. THIS DETAIL DOES NOT APPLY TO STRUCTURAL GABLES. 9. DO NOT USE FLAT BOTTOM CHORD GABLES NEXT TO SCISSOR TYPE TRUSSES. TRUSS GEOMETRY AND CONDITIONS SHOWN ARE FOR ILLUSTRATION ONLY. - L-Bracing Refer ** to Section B-B B B + + + + (4) - 16d Common Wire Nails (2) - 10d Common Wire Nails into 2x6 16d Common Wire Nails Spaced 6" o.c. Vertical Stud Typical _x4 L-Brace Nailed To 2x_ Verticals W/10d Nails, 6" o.c. SECTION B-B PROVIDE 2x4 BLOCKING BETWEEN THE FIRST TWO TRUSSES AS NOTED. TOENAIL BLOCKING TO TRUSSES WITH (2) - 10d NAILS AT EACH END. ATTACH DIAGONAL BRACE TO BLOCKING WITH (5) - 10d COMMON WIRE NAILS. 2x6 DIAGONAL BRACE SPACED 48" O.C. ATTACHED TO VERTICAL WITH (4) -16d COMMON WIRE NAILS AND ATTACHED TO BLOCKING WITH (5) - 10d COMMONS. DIAGONAL BRACE 9-2-11 8-4-9 7-3-13 2x3 SPF No.3 2x3 SPF No.3 Diagonal braces over 6’-3" require a 2x4 T-Brace attached to one edge. Diagonal braces over 12’-6" require 2x4 I-braces attached to both edges. Fasten T and I braces to narrow edge of web with 10d common wire nails 8in o.c., with 3in minimum end distance. Brace must cover 90% of diagonal length. 6-1-13 5-3-15 4-4-3 ** 2 DIAGONAL BRACES AT 1/3 POINTS 13-10-0 12-6-13 10-11-12 Diag. Brace at 1/3 points if needed STUD DESIGN IS BASED ON COMPONENTS AND CLADDING. CONNECTION OF BRACING IS BASED ON MWFRS. WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/ diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage, delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from SBCA at www.sbcindustry.com. TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING Plates Increase Lumber Increase Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI TC BC WB (Matrix) 0.12 0.05 0.04 DEFL Vert(LL) Vert(TL) Horz(TL) in -0.01 -0.01 0.00 (loc) 9 9 8 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 44 lb FT = 20% GRIP 197/144 LUMBER TOP CHORD 2 X 4 SPF No.2 BOT CHORD 2 X 4 SPF No.2 OTHERS 2 X 3 SPF No.2 WEDGE Left: 2 X 4 SPF Stud, Right: 2 X 4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS All bearings 9-4-0. (lb) - Max Horz 2=-120(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 2, 8, 13, 14, 11, 10 Max Grav All reactions 250 lb or less at joint(s) 2, 8, 12, 13, 14, 11, 10 FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 8, 13, 14, 11, 10. 8) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/ diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage, delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from SBCA at www.sbcindustry.com. June 24,2011 21 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 3x6 4x6 3x6 3x8 3x6 3x8 22-7-0 22-7-0 10-1-2 -1-3-4 1-3-4 11-3-8 11-3-8 22-7-0 11-3-8 23-10-4 1-3-4 10-1-2 0-8-7 11-11-15 0-8-7 12.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING Plates Increase Lumber Increase Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI TC BC WB (Matrix) 0.12 0.05 0.17 DEFL Vert(LL) Vert(TL) Horz(TL) in -0.01 -0.01 0.01 (loc) 21 21 20 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 156 lb FT = 20% GRIP 197/144 LUMBER TOP CHORD 2 X 4 SPF No.2 BOT CHORD 2 X 4 SPF No.2 OTHERS 2 X 3 SPF No.2 *Except* ST8,ST7: 2 X 4 SPF No.2 WEDGE Left: 2 X 4 SPF Stud, Right: 2 X 4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS T-Brace: 2 X 4 SPF Stud - 11-30, 10-31, 9-32, 12-29, 13-28 Fasten (2X) T and I braces to narrow edge of web with 10d (0.131"x3") nails, 6in o.c.,with 3in minimum end distance. Brace must cover 90% of web length. REACTIONS All bearings 22-7-0. (lb) - Max Horz 2=-274(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 31, 32, 33, 34, 35, 36, 37, 20, 29, 28, 27, 25, 24, 23, 22 except 2=-104(LC 4) Max Grav All reactions 250 lb or less at joint(s) 2, 30, 31, 32, 33, 34, 35, 36, 37, 20, 29, 28, 27, 25, 24, 23, 22 FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-299/169 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) All plates are 1.5x4 MT20 unless otherwise indicated. 5) Gable requires continuous bottom chord bearing. 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 31, 32, 33, 34, 35, 36, 37, 20, 29, 28, 27, 25, 24, 23, 22 except (jt=lb) 2=104. 9) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required. LOAD CASE(S) Standard WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/ diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage, delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from SBCA at www.sbcindustry.com. June 24,2011 Lumber Increase Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI TC BC WB (Matrix) 0.06 0.04 0.01 DEFL Vert(LL) Vert(TL) Horz(TL) in 0.00 0.00 0.00 (loc) 6 6 5 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 16 lb FT = 20% GRIP 197/144 LUMBER TOP CHORD 2 X 4 SPF No.2 BOT CHORD 2 X 4 SPF No.2 WEBS 2 X 3 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except 2-0-0 oc purlins (6-0-0 max.): 3-4. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS All bearings 4-8-8. (lb) - Max Horz 2=-37(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 2, 5, 8 Max Grav All reactions 250 lb or less at joint(s) 2, 5, 8, 7 FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 5, 8. 7) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. 9) Design assumes 4x2 (flat orientation) purlins at oc spacing indicated, fastened to truss TC w/ 2-10d nails. LOAD CASE(S) Standard WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/ diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage, delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from SBCA at www.sbcindustry.com. June 24,2011 BC WB (Matrix) 0.09 0.27 0.00 DEFL Vert(LL) Vert(TL) Horz(TL) in 0.00 0.00 0.00 (loc) 5 5 4 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 14 lb FT = 20% GRIP 197/144 LUMBER TOP CHORD 2 X 4 SPF No.2 BOT CHORD 2 X 4 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 2=213/4-8-8 (min. 0-1-8), 4=213/4-8-8 (min. 0-1-8) Max Horz 2=-43(LC 4) Max Uplift 2=-21(LC 6), 4=-21(LC 7) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4. 6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. LOAD CASE(S) Standard WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/ diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage, delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from SBCA at www.sbcindustry.com. June 24,2011 BCDL 20.0 10.0 0.0 10.0 SPACING Plates Increase Lumber Increase Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI TC BC WB (Matrix) 0.16 0.09 0.05 DEFL Vert(LL) Vert(TL) Horz(TL) in 0.00 0.00 0.00 (loc) 8 9 8 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 42 lb FT = 20% GRIP 197/144 LUMBER TOP CHORD 2 X 4 SPF No.2 BOT CHORD 2 X 4 SPF No.2 WEBS 2 X 3 SPF No.2 OTHERS 2 X 3 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except 2-0-0 oc purlins (6-0-0 max.): 3-7. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS All bearings 14-8-8. (lb) - Max Horz 2=-37(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 2, 8, 14, 10, 12, 13, 11 Max Grav All reactions 250 lb or less at joint(s) 2, 8, 14, 10 except 12=343(LC 1), 13=254(LC 11), 11=254(LC 10) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 5-12=-257/104 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 8, 14, 10, 12, 13, 11. 7) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. 9) Design assumes 4x2 (flat orientation) purlins at oc spacing indicated, fastened to truss TC w/ 2-10d nails. LOAD CASE(S) Standard WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/ diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage, delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from SBCA at www.sbcindustry.com. June 24,2011 GABLE TRUSS STANDARD GABLE TRUSS AN ADEQUATE DIAPHRAGM OR OTHER METHOD OF BRACING MUST BE PRESENT TO PROVIDE FULL LATERAL SUPPORT OF THE BOTTOM CHORD TO RESIST ALL OUT OF PLANE LOADS. THE BRACING SHOWN IN THIS DETAIL IS FOR THE VERTICAL/STUDS ONLY. HORIZONTAL BRACE (SEE SECTION A-A) Page 2 of 2 OCTOBER 1, 2006 WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/ diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage, delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from SBCA at www.sbcindustry.com. 2. CONNECTION BETWEEN BOTTOM CHORD OF GABLE END TRUSS AND WALL TO BE PROVIDED BY PROJECT ENGINEER OR ARCHITECT. 3. BRACING SHOWN IS FOR INDIVIDUAL TRUSS ONLY. CONSULT BLDG. ARCHITECT OR ENGINEER FOR TEMPORARY AND PERMANENT BRACING OF ROOF SYSTEM. 4. "L" BRACES SPECIFIED ARE TO BE FULL LENGTH. GRADES: 1x4 SRB OR 2x4 STUD OR BETTER WITH ONE ROW OF 10d NAILS SPACED 6" O.C. 5. DIAGONAL BRACE TO BE APPROXIMATELY 45 DEGREES TO ROOF DIAPHRAM AT 4’-0" O.C. 6. CONSTRUCT HORIZONTAL BRACE CONNECTING A 2x6 STUD (or 2X4 No.2 OR BETTER) AND A 2x4 STUD AS SHOWN WITH 16d NAILS SPACED 6" O.C. HORIZONTAL BRACE TO BE LOCATED AT THE MIDSPAN OF THE LONGEST STUD. ATTACH TO VERTICAL STUDS WITH (4) 10d NAILS THROUGH 2x4. (REFER TO SECTION A-A) 7. GABLE STUD DEFLECTION MEETS OR EXCEEDS L/240. 8. THIS DETAIL DOES NOT APPLY TO STRUCTURAL GABLES. 9. DO NOT USE FLAT BOTTOM CHORD GABLES NEXT TO SCISSOR TYPE TRUSSES. TRUSS GEOMETRY AND CONDITIONS SHOWN ARE FOR ILLUSTRATION ONLY. - L-Bracing Refer ** to Section B-B B B + + + + (4) - 16d Common Wire Nails (2) - 10d Common Wire Nails into 2x6 16d Common Wire Nails Spaced 6" o.c. Vertical Stud Typical _x4 L-Brace Nailed To 2x_ Verticals W/10d Nails, 6" o.c. SECTION B-B PROVIDE 2x4 BLOCKING BETWEEN THE FIRST TWO TRUSSES AS NOTED. TOENAIL BLOCKING TO TRUSSES WITH (2) - 10d NAILS AT EACH END. ATTACH DIAGONAL BRACE TO BLOCKING WITH (5) - 10d COMMON WIRE NAILS. 2x6 DIAGONAL BRACE SPACED 48" O.C. ATTACHED TO VERTICAL WITH (4) -16d COMMON WIRE NAILS AND ATTACHED TO BLOCKING WITH (5) - 10d COMMONS. DIAGONAL BRACE 9-2-11 8-4-9 7-3-13 2x3 SPF No.3 2x3 SPF No.3 Diagonal braces over 6’-3" require a 2x4 T-Brace attached to one edge. Diagonal braces over 12’-6" require 2x4 I-braces attached to both edges. Fasten T and I braces to narrow edge of web with 10d common wire nails 8in o.c., with 3in minimum end distance. Brace must cover 90% of diagonal length. 6-1-13 5-3-15 4-4-3 ** 2 DIAGONAL BRACES AT 1/3 POINTS 13-10-0 12-6-13 10-11-12 Diag. Brace at 1/3 points if needed STUD DESIGN IS BASED ON COMPONENTS AND CLADDING. CONNECTION OF BRACING IS BASED ON MWFRS. WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/ diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage, delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from SBCA at www.sbcindustry.com. Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI TC BC WB (Matrix) 0.13 0.10 0.13 DEFL Vert(LL) Vert(TL) Horz(TL) in 0.00 0.00 0.00 (loc) 7 7 6 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 48 lb FT = 20% GRIP 197/144 LUMBER TOP CHORD 2 X 4 SPF No.2 BOT CHORD 2 X 4 SPF No.2 WEBS 2 X 3 SPF No.2 OTHERS 2 X 3 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS All bearings 14-8-8. (lb) - Max Horz 2=-130(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 2 except 10=-101(LC 6), 8=-101(LC 7) Max Grav All reactions 250 lb or less at joint(s) 2, 6, 9 except 10=336(LC 10), 8=336(LC 11) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2 except (jt=lb) 10=101, 8=101. 6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. LOAD CASE(S) Standard WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/ diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage, delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from SBCA at www.sbcindustry.com. June 24,2011 Lumber Increase Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI TC BC WB (Matrix) 0.26 0.17 0.10 DEFL Vert(LL) Vert(TL) Horz(TL) in 0.00 0.01 0.00 (loc) 6 6 5 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 43 lb FT = 20% GRIP 197/144 LUMBER TOP CHORD 2 X 4 SPF No.2 BOT CHORD 2 X 4 SPF No.2 WEBS 2 X 3 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except 2-0-0 oc purlins (6-0-0 max.): 3-4. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS All bearings 14-8-8. (lb) - Max Horz 2=-84(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 2, 5, 8, 7 Max Grav All reactions 250 lb or less at joint(s) 2, 5 except 8=416(LC 10), 7=416(LC 11) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-8=-294/115, 4-7=-294/94 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 5, 8, 7. 7) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. 9) Design assumes 4x2 (flat orientation) purlins at oc spacing indicated, fastened to truss TC w/ 2-10d nails. LOAD CASE(S) Standard WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/ diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage, delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from SBCA at www.sbcindustry.com. June 24,2011 TRUSS TOP CHORD AT SPECIFIED SPACING SHOWN ON BASE TRUSS DESIGN DRAWING. CONNECTION AS ABOVE DETAIL IS NOT APPLICABLE FOR TRUSSES TRANSFERING DRAG LOADS (SHEAR TRUSSES). ADDITIONAL CONSIDERATIONS BY BUILDING ENGINEER/DESIGNER ARE REQUIRED. MAXIMUM WIND SPEED = 100 MPH MAX MEAN ROOF HEIGHT = 30 FEET CATEGORY II BUILDING EXPOSURE B or C ASCE 7-98, ASCE 7-02, ASCE 7-05 DURATION OF LOAD INCREASE : 1.60 * * Page 1 of 1 FEBRUARY 13, 2007 Attach MiTek 3x6 20 GA. Nail-On plates to each face of truss at 72" o.c. w/ 8d x 1 1/2" common wire nails (.131"x1.5"). Do not use holes within 1/2"of the edge of member. Apply 4 nails from each face in each member. Nails should be staggered and equally divided between front and back. WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/ diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage, delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from SBCA at www.sbcindustry.com. BCDL 20.0 10.0 0.0 10.0 SPACING Plates Increase Lumber Increase Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI TC BC WB (Matrix) 0.16 0.09 0.05 DEFL Vert(LL) Vert(TL) Horz(TL) in 0.00 0.00 0.00 (loc) 8 9 8 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 42 lb FT = 20% GRIP 197/144 LUMBER TOP CHORD 2 X 4 SPF No.2 BOT CHORD 2 X 4 SPF No.2 WEBS 2 X 3 SPF No.2 OTHERS 2 X 3 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except 2-0-0 oc purlins (6-0-0 max.): 3-7. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS All bearings 14-8-8. (lb) - Max Horz 2=-37(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 2, 8, 14, 10, 12, 13, 11 Max Grav All reactions 250 lb or less at joint(s) 2, 8, 14, 10 except 12=343(LC 1), 13=254(LC 11), 11=254(LC 10) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 5-12=-257/104 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 8, 14, 10, 12, 13, 11. 7) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. 9) Design assumes 4x2 (flat orientation) purlins at oc spacing indicated, fastened to truss TC w/ 2-10d nails. LOAD CASE(S) Standard WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/ diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage, delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from SBCA at www.sbcindustry.com. June 24,2011 SPACING Plates Increase Lumber Increase Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI TC BC WB (Matrix) 0.40 0.08 0.00 DEFL Vert(LL) Vert(TL) Horz(TL) in -0.01 -0.02 0.00 (loc) 4-5 4-5 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 16 lb FT = 20% GRIP 197/144 LUMBER TOP CHORD 2 X 4 SPF No.2 BOT CHORD 2 X 4 SPF No.2 WEBS 2 X 3 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 4-4-10 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 5=303/0-4-13 (min. 0-1-8), 4=115/Mechanical Max Horz 5=106(LC 4) Max Uplift 5=-85(LC 5), 4=-25(LC 4) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-5=-263/105 NOTES 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 4. 5) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 11 lb down and 22 lb up at 1-0-14, and 0 lb down and 33 lb up at 1-11-0 on top chord, and 8 lb up at 1-0-14, and 11 lb up at 1-11-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Regular: Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 4-5=-20 Concentrated Loads (lb) Vert: 6=19(F) 7=22(B) 8=4(F) 9=6(B) WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/ diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage, delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from SBCA at www.sbcindustry.com. June 24,2011 CSI TC BC WB (Matrix) 0.40 0.05 0.02 DEFL Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 -0.00 (loc) 4-5 4-5 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 11 lb FT = 20% GRIP 197/144 LUMBER TOP CHORD 2 X 4 SPF No.2 BOT CHORD 2 X 4 SPF No.2 WEBS 2 X 3 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 2-2-15 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 5=288/0-8-11 (min. 0-1-8), 4=9/Mechanical Max Horz 5=66(LC 5) Max Uplift 5=-112(LC 6), 4=-11(LC 5) Max Grav 5=288(LC 1), 4=44(LC 4) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-5=-267/160 NOTES 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4 except (jt=lb) 5=112. 5) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard WARNING - Verify design parameters and read notes on this Truss Design Drawing and included DrJ Reference Sheet (rev. 03-11’) before use. Design valid for use with MiTek connector plates only. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of the component is responsibility of building designer or owner of the trusses and installer. Lateral restraint designations shown on individual web and chord members are for compression buckling only, not forbuilding stability bracing. Additional temporary restraint/ diagonal bracing to insure stability during construction is the responsibility of the installer. Additional permanent building stability bracing of the overall structure is the responsibility of the building designer or owner of the trusses. For general guidance regarding design responsibilities, fabrication, quality control, storage, delivery, erection, lateral restraint and diagonal bracing, consult ANSI/TPI 1, DSB-89 and BCSI (Building Component Safety Information) available from SBCA at www.sbcindustry.com. June 24,2011