Loading...
HomeMy WebLinkAboutA101 Construction Plans.PDFTHEATER 7-C-1 PARKING GARAGE 7-C-3 E.C. OFFICE BLDG. 7-C-2 7-C- 4 SCALE: NTS PLAN NORTH KEY PLAN 7-C-9 7-C-11 Project: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: Sheet Title: VILLAGE ON THE GREEN PARCEL 7C-20 CARMEL, IN, 46032 COPYRIGHT & OWNERSHIP OF DOCUMENTS Architecture / Project Management: Project Number: Last Revision Date: Drawn By Checked By Civic Offices Interiors Print Date Sheet Issue Date PEDCOR DESIGN GROUP, LLC PARCEL 7C-20 A101 Construction Plans THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2009, 2010 JAMES R. STUTZMAN, AIA, CARMEL. lga/mc 11711 North Pennsylvania Street, Suite 200 Carmel, Indiana 46032 317.573-6050 CARMEL THEATER Owner: DEVELOPMENT CORPORATION, LLC ajr BID SET 3/7/11 2/01/11 CIVIC OFFICES 7-C-20 24'-3 3/8" 16'-8 5/8" 11'-8 1/4" 11'-6 3/4" 7'-1 1/4" 1'-9 1/4" 4'-8" 8 1/4" 1'-0" 2'-5 1/8" 11 3/4" 11 3/4" 11 3/4" 1'-0" 3 7/8" 3 7/8" 1'-0" 8 1/8" 3 7/8" 3 7/8" 4'-11 1/8" 9'-1 3/4" 5'-9 1/4" 5'-1 3/4" 4'-0" 5'-1 3/4" 10'-4 1/2" 2'-1 1/4" 3'-9 1/4"HOLD 2'-10" 10'-9 5/8" 10'-2 1/2" 16'-5 5/8" 4'-11 3/4" 1 A403 2 A403 3 A403 224 225A 225B 226 227 230 222 228 CL. 222 STORAGE 230 RECEPTION 221 WAITING 220 COPY/PRINT IDF 229 228 CONFERENCE 225 OFFICE 224 OFFICE 226 HALL 223 OFFICE 227 W2 W2 W5 W4 W4 W5 W3 W5 W5 W3 W3 W3 W3 W3 W3 W3 W2 W3 W3 W3 W3 W3 FINISH FINISH FINISH FINISH W7 W7 W7 W7 W7 W7 W3 EXIST. 2'-4 1/2" 1'-0" FP1 FP6 FP3 FP5 FP4 FP11 FP11 FP11 FP11 FP2 F DW 2 A402 20'-7 5/8" 12'-9 3/8" 13'-8 1/8" 10'-6 1/8" 12'-2 1/8" 11'-11 7/8" 11'-10 7/8" 13'-2 1/2" 13'-7 1/2" 22'-7" 10'-7/8" 10'-1 1/4" 4'-7 5/8" 2'-1 1/4" 5'-9 3/8" 10'-7 1/8" 4'-7 3/8" 12'-3/8" 14'-2 1/8" 12'-3 3/8" 8'-3" 5'-1 1/4" 8'-4" 8'-3 3/8" 5'-5/8" 8'-3 3/8" 5'-10" 8'-8 3/4" 2'-0" 5'-11 3/8" 13'-7 7/8" 8'-4" 4'-6" 6'-0" 1'-11 1/4" 2'-6 1/2" 5 7/8" 11 3/4" 1'-0" 1'-0" 11 3/4" 11 3/4" 1'-0" 3 1/8" 11 3/4" 1'-0" 3 7/8" 1'-0" 3 7/8" 11 3/4" 2'-7 3/8" 1'-0" 3 1/4" 11 3/4" 2'-6 1/4" 11 3/4" 11 3/4" 1'-0" 3 7/8" 11 3/4" 2'-7 1/8" 9'-11" 4'-6" 3'-4 1/8" 3 7/8" 3 7/8" 3 7/8" 4'-3 1/4" 2'-3 3/8" 2'-4" 3'-9 1/4"HOLD 2'-4 7/8" 3'-11 7/8" 150° 150° 6 A403 4 A403 5 A403 327 328 329 330 331 332 333A 333B 341 340 338 339 334 324 321 323 322 325 WOMEN'S 323 MEN'S 321 STOR. 324 WORK ROOM 325 OFFICE 327 OFFICE 330 OFFICE 331 OFFICE 339 OFFICE OFFICE 332 333 BREAK AREA 335 OFFICE 338 STOR. 340 CL. 341 CL. 322 HALL 320 HALL 326 WAR ROOM 334 HALL 336 HALL 337 W3 W3 W3 W2 W2 W2 W2 W3 W3 W3 W5 W5 W3 W3 W3 W3 W3 W3 W2 W2 W3 W2 W2 W2 W2 W2 W3 W2 W5 W5 W3 W3 W3 W3 W3 W3 W2 W2 W2 W2 W2 W5 W5 W5 W5 OFFICE 328 OFFICE 329 FINISH FINISH FINISH FINISH FINISH FINISH FINISH W7 W7 W7 W7 W7 W7 W7 W7 W7 W7 W6 W6 W6 W6 W6 W7 W7 FINISH FINISH 11'-10 3/8" 15'-8 1/8" FP1 FP1 FP1 FP1 FP1 FP9 FP10 FP8 FP5 FP3 FP1 FP5 FP5 FP6 FP11 FP1 FP11 FP11 FP11 FP2 FP11 FP11 FP11 FP7 FP1 FP1 ALL NEW WORKSURFACES TO RECEIVE 3" GROMMETS. NEW GROMMET LOCATIONS TO BE VERIFIED WITH TENANT IN FIELD AND WITH RESPECT TO NEW ELECTRICAL LAYOUT. GROMMET COLOR TO BE: BLACK RADIUS ALL OUTSIDE CORNERS OF COUNTER TOPS. SIZE OF RADIUS TO BE VERIFIED WITH DESIGNER. 11. APPLY SEALANT AT ALL PLUMBING FIXTURES, AT JUNCTURE WITH WALL AND AT ALL COUNTERTOPS AND BACKSPLASH JUNCTURES. 12. FLOOR SHALL BE CLEANED, SMOOTH AND LEVEL FOR INSTALLATION OF NEW FLOOR FINISHES AS SCHEDULED. 13. ALL WALLS SCHEDULED TO REMAIN (I.E. CORE WALLS, AND DEMISING WALLS) SHALL BE PATCHED, REPAIRED, AND SANDED SMOOTH IN PREPARATION FOR NEW FINISHES. 14. UNDERCOUNTER GARBAGE DISPOSAL TO BE PROVIDED AND INSTALLED BY G.C. PROVIDE POWER SOURCE FOR GARBAGE DISPOSAL. VERIFY ELECTRICAL REQUIREMENTS WITH MANUFACTURER'S MANUAL. G.C. TO INSTALL TENANT PROVIDED DISHWASHER. G.C. TO CONFIRM UNIT IS IN WORKING ORDER AND IS NOT LEAKING BEFORE TURNING UNIT OVER TO TENANT. REFRIGERATOR PROVIDED AND INSTALLED BY TENANT. G.C. TO PROVIDE POWER SOURCE FOR REFRIGERATOR. VERIFY ELECTRICAL REQUIREMENTS WITH MANUFACTURER'S MANUAL. PROVIDE 1/4" COLD COPPER LINES WITH VALVE FOR TENANT SUPPLIED ICE MAKER, REFRIGERATOR, AND COFFEE MAKER. VERIFY EXACT LOCATION OF ALL APPLIANCES REQUIRING A WATER SOURCE WITH TENANT. COPIER PROVIDED AND INSTALLED BY TENANT. G.C. TO PROVIDE POWER SOURCE FOR COPY MACHINE. VERIFY ELECTRICAL REQUIREMENTS WITH MANUFACTURER'S MANUAL. (5) 12"dp. 3/4" PAINTED PLYWOOD SHELVES ON HEAVY DUTY KV 187-72" STANDARDS & KV 87-12" BRACKETS. PROVIDE ADDITIONAL BLOCKING AS REQUIRED REFERENCE 8/A404. PROVIDE 3/4"x4'x8' FIRE RETARDANT PLYWOOD PHONE BOARD(S) LENGTH OF WALL. PHONE BOARD TO BE PAINTED WITH FIRE RETARDANT PAINT, COLOR OF PAINT TO MATCH ADJACENT WALL FINISH. PROVIDE COAT ROD AND SHELF. REFERENCE DETAIL 5/404. NEW SEMI- RECESSED FIRE EXTINGUISHER CABINET TO BE INSTALLED IN WALL AT THIS LOCATION WITH TOP OF CABINET AT 54" AFF. PAINT TO MATCH ADJACENT WALL SURFACE. FIRE EXTINGUISHER CABINET TO MATCH BUILDING STANDARD, UNLESS NOTED OTHERWISE. IF NO BUILDING STANDARD, PROVIDE JL INDUSTRIES "AMBASSADOR" SERIES, SEMI-RECESSED, DUO-PANEL, FIELD PAINTED. ALIGN FINISHED FACES. FP10 FP9 FP8 CONSTRUCTION PLAN NOTES: FP1 FP2 FP3 FP4 FP5 FP6 FP7 400 NEW DOOR AND FRAME. REFER TO DOOR SCHEDULE. DENOTES NEW MILLWORK. DENOTES AREA NOT IN CONTRACT. GENERAL CONSTRUCTION NOTES: DIMENSIONS ARE FROM FACE OF STUD TO FACE OF STUD UNLESS NOTED OR SHOWN OTHERWISE. ANY DIMENSION NOT SHOWN OR DEEMED QUESTIONABLE ARE TO BE VERIFIED BY DESIGNER. DO NOT SCALE DRAWINGS. 1. 2. ALL WALLS SHALL BE CHALKED OFF FOR ARCHITECTS REVIEW OF NEW WALL CONSTRUCTION. REUSE DOORS, FRAMES, AND PARTITIONS SYSTEMS AS MUCH AS FEASIBLE. VERIFY WITH ARCHITECT AND OWNER ANY ITEMS WHICH ARE QUESTIONABLE FOR REUSE. 3. PROVIDE CONCEALED FIRE RATED WOOD BLOCKING SUPPORTS AS REQUIRED FOR ALL SURFACE MOUNTED ITEMS. 4. EXISTING DOORS AND DOOR FRAMES TO BE REUSED ARE TO BE CLEANED AND REINSTALLED AT COMPLETION OF CONSTRUCTION. CONTACT ARCHITECTS TO REVIEW AND APPROVE DOORS THAT ARE QUESTIONABLE FOR REUSE. 5. NEW DOOR AND FRAME NUMBERS CORRESPOND TO ROOM NUMBERS. WHERE MORE THAN ONE DOOR OCCURS IN A ROOM, A SUFFIX HAS BEEN ADDED (ie. 100A). 6. 7. ALL NEW DOORS TO BE INSTALLED WITH HINGE 6" AWAY FROM WALL. ALL NEW DOORS SHALL ALLOW 12" CLEAR ON PUSH SIDE AND 18" CLEAR ON PULL SIDE OF DOOR, UNLESS NOTED OTHERWISE, TO MEET CURRENT ADA CODE REGULATIONS. 8. ALL NEW FIRE EXTINGUISHER CABINETS TO BE FINISHED TO MATCH ADJACENT WALL FINISH AND INSTALLED ACCORDING TO CODE. 9. 10. 3-5/8" 25 GAUGE METAL STUDS @16"O.C. 4-7/8" 4-7/8" 4-1/4" 4-7/8" 4-7/8" PROVIDE 2-1/2" SOUND INSULATION INSIDE WALL. WALLS TO EXTEND TO STRUCTURAL DECK ABOVE. WITH 5/8" GYPSUM WALL BOARD EACH SIDE. 3-5/8" 25 GAUGE METAL STUDS @16"O.C. WALLS TO EXTEND TO STRUCTURAL DECK ABOVE. W5 WITH 5/8" GYPSUM WALL BOARD EACH SIDE. WALLS TO EXTEND TO 6" ABOVE CEILING. W4 3-5/8" 25 GAUGE METAL STUDS @16"O.C. WITH 5/8" GYPSUM WALL BOARD ONE SIDE. W3 DIRECTIONS FROM CENTER LINE OF WALL. 3-5/8" 25 GAUGE METAL STUDS @16" O.C. SURFACE ABOVE CEILING. INSULATION TO EXTEND 2'-0" IN BOTH PROVIDE 2-1/2" SOUND INSULATION INSIDE WALL AND IN HORIZONTAL WALLS TO EXTEND TO 6" ABOVE CEILING. WITH 5/8" GYPSUM WALL BOARD EACH SIDE. W2 WALLS TO EXTEND TO 6" ABOVE CEILING. 3-5/8" 25 GAUGE METAL STUDS @16"O.C. WITH 5/8" GYPSUM WALL BOARD EACH SIDE. W1 EXISTING PARTITION TO REMAIN NEW WALL PARTITION NEW WALLS TO BE W1 UNLESS NOTED OTHERWISE. WALL LEGEND: NOTES: PROVIDE HORIZONTAL BLINDS AT EXTERIOR WINDOWS. SEE FINISH LEGEND FOR SPECIFICATION. MOUNT BLINDS IN WINDOW WELL OF 2ND FLOOR WINDOWS TO COVER FULL HEIGHT AND WIDTH OF OPENINGS. MOUNT BLINDS TO BOTTOM OF ARCH OF WINDOWS ON THE 3RD FLOOR TO COVER ONLY LOWER STRAIGHT SECTIONS. ARCH SECTIONS TO REMAIN OPEN. FP11 2-1/8" WALLS TO EXTEND TO STRUCTURAL DECK ABOVE. WITH 5/8" GYPSUM WALL BOARD ONE SIDE. W6 1-1/2" FURRING CHANNEL 5/8" 5/8" GYPSUM WALL BOARD ONE SIDE ON EXISTING STUD WALL. WALLS TO EXTEND TO STRUCTURAL DECK ABOVE. W7 C.5 C.7 C.8 C.9 D D.2 D.3 D.5 D.6 D.9 E E.3 E.5 B.4 B.5 B.7 B.8 C C.2 C.3 C.4 C.5 C.7 C.8 C.9 D D.2 D.3 D.5 D.6 D.9 E E.3 E.5 11 10.9 10.4 10.8 9 9.7 10 10.3 9.2 11 10.9 10.4 10.8 9.7 10 10.3 SCALE: 1/4" = 1'-0" 1 2nd Floor Construction Plan A101 SCALE: 1/4" = 1'-0" 2 3rd Floor Construction Plan A101