HomeMy WebLinkAboutLDR 6-30-11.pdf Architectural: Nick Slater Kyle Hardie MSKTD & Associates 317.917.1190 MEP: John Wilczynsky Moore Engineers 317.848.5045 Indicates existing wall to be removed in its entirety. Indicates existing door, frame and associated hardware to be removed in its entirety. see door schedule for items to be salvaged and reused in other areas. 1. These demolition notes shall serve to aid the contractor in the evaluation of the extent of demolition; but shall not be held to be all inclusive. 2. Contractors shall be responsible for all demolition required for the installation of new construction, whether or not it is specifically shown or noted in these documents. 3. Remove all damaged gypsum board, or concrete from existing surfaces an repair to match adjacent construction. 4. Selective electrical, mechanical, and fireprotection demolition will result in various wall/floor/ceiling openings. Contractor to repair these areas as necessary in accordance with specifications. 5. "Construction Limits" generally illustrate areas of demolition. Other work may be required for demolition or replacement of the other systems including MEP above ceiling items. 6. All demolition material becomes the property of the contractor and is to be removed from hospital property, in a legal manner. The owner reserves the right to claim items whether or not those items were specifically noted "to be relocated" or "to be returned to owner." 7. The contractor is responsible for salvaging all items in good condition for owners re-use: lights, ceiling tiles, doors, windows, plumbing fixtures, toilet accessories, etc. 8. Refer to IU Health "Mandatory Contractor's Orientation Requirements" (MCOR) for additional requirements. 9. Contractor to provide ten-day notice with owner-supplied forms for all system shut-downs to facilities. Minimal exceptions will be amde in cases of emergency or schedule conflicts on an owner determined basis. 10. Contractors shall be responsible for providing, installing and maintaining dust tight temporary construction barriers to to all areas within the construction limit lines, during the construction process. locations shall be coordinated with the owner and architect. 11. Items shown in lighter pen weights are existing to remain. 12. Protect from demolition and reconstruction debris, all "Existing to Remain" fixtures and equipment required to remain in plce during construction. 13. The contractor responsible for general demolition work shall coordinate any and all asbestos removal with the owner. All asbestos removal will be preformed by a licensed asbestos removal contractor. this typically includes floor tile, tile mastic and pipe insulation. 1. Portions of the building shall be occupied during construction. Contractors shall comply with the following life safety issues. Failure to list all life safety issues does not relieve the contractors from complying with federal, state and local codes, the contractural agreement between the contractor and the owner,and the other governing bodies which have jursidiction on this project. The following are interim life safety code issues which are specific to this project and must be addressed. A. Insure all exits provide free and unobstructed egress. B. Smoking shall be prohibited in all areas of the building. Campus is smoke free environment. C. Develop and enforce storage, housekeeping and debris removal procedures that reduce the flammable and combustible fire load to the lowest level necessary for daily operations. D. Secure all tools and construction materials during breaks and non-construction hours. E. IOSHA requires material safety data sheets (MSDS) for all materials being used or stored on this project be made available to all workers on this jobsite. 2. The contractors shall be responsible for informing the owner in writing on a bi-weekly basis, the construction schedule for the approaching two weeks construction period. Any storage materials access or egress problems, traffic flow or normal owner operations which are to be affected must be protected and/or agreed upon by owner. All costs shall be incurred by the general contractor. 3. Any services which must be temporarily shut off must be coordinated with the owner. 4. All construction areas, removal traffic pattern areas and associated work areas shall be kept clean of debris by the contractors daily. 5. Fire rated wall and ceiling penetrations must comply with E-814. 6. The general contractor shall provide all necessary fire treated wood blocking for all trades. Continuous blocking required for all wall hung shelving, casework, grab bars and handrails. Brace walls with wall hung items to deck as by printed stud mfg. recommendations. 7. Dimensions are to face of stud or masonry, unless otherwise noted. 8. Existing surfaces shall be prepared to accept new finishes, per finish material manufacturer recommendations. This preperation of substrate shall be the responsibility of the particular finish contractor. If no preperation work is done to surfaces, the contractor accepts the conditions as they are, and is responsible for the performance of the material. 9. "Construction Limits" generally illustrate areas of new construction. Other work may be required for demolition or replacement of the other systems including the MEP. 10. Contractor to provide ten-day notice with owner-supplied forms for all system shut-downs to facilities. Minimal exceptions will be made in cases of emergency or schedule conflicts on an owner-determined basis. ROOM NAME 101 1 A101 SIM 1t 1 A 101A A101 1 SIM DETAIL NUMBER SHEET NUMBER DETAIL NUMBER SHEET NUMBER XX NEW DOOR AND FRAME SPECIFIC CONSTRUCTION NOTES ROOM NAME AND NUMBER ELEVATION SYMBOL PLAN DETAIL NEW COLUMN LINE EXISTING COLUMN LINE SECTION PARTITION TYPE WINDOW ELEVATION SYMBOL TOILET ACCESSORY 1 SPECIFIC DEMOLITION NOTES 3.15iA XX.X X SHEET NUMBER DETAIL NUMBER 1.5B EXTEND TO DECK 5/8" GYPSUM BOARD (BOTH SIDES) 3 1/2" SOUND ATTENUATION BLANKET 3 5/8" 20 GA. METAL STUD FRAMING (@16" o.c.) ALIGN ALL CEILING AND BULKHEAD REVEALS, CONTROL OR SEISMIC JOINTS WITH THE ADJACENT REVEAL, CONTROL OR SEISMIC JOINTS IN WALLS INDICATED ON ELEVATIONS. ALL CEILING AND BULKHEAD HEIGHTS INDICATED ARE TO FINISHED FACE OF GYPSUM BOARD OR TO THE BOTTOM FACE OF ACOUSTICAL CEILING TILE PAD, UNLESS NOTED OTHERWISE. CEILING CONTRACTOR TO PROVIDE ALL CEILING GRID TO SUPPORT HVAC SUPPLY DIFFUSERS AND RETURN GRILLS. DEVICES OTHER THAN LIGHTING AND DIFFUSERS ARE SHOW IN APPROXIMATE LOCATIONS, FINAL LOCATION TO BE COORDINATED WITH ALL TRADES AND ARCHITECT. AT LOCATIONS WHERE GYPSUM BOARD CEILINGS ARE INDICATED, THE CONTRACTOR HAS THE OPTION TO USE LIGHT GAGE METAL FRAMING OR SUSPENDED GYPSUM BOARD GRID UNLESS OTHERWISE DETAILED. THE CONTRACTOR WILL COORDINATE ANY MODIFICATIONS WITH THE OTHER TRADES ON THE PROJECT. THE CEILING CONTRACTOR'S FINAL MEANS AND METHODS WILL NOT CONFLICT WITH THE WORK OF OTHERS OR THE INTENT OF THESE DOCUMENTS. THESE NOTES APPLY TO ALL CONSTRUCTION DRAWINGS AND TO ALL CONTRACTORS AND/OR SUBCONTRACTORS THAT WORK WITHIN THIS BUILDING. WHERE EXISTING SUSPENDED ACOUSTICAL CEILINGS ARE SCHEDULED TO REMAIN, CUT AND PREP THE CEILING GRID IN PREPARATION FOR REPAIRING. SALVAGE ENOUGH CEILING PADS FOR RECONSTRUCTION. STORE AND PROTECT ALL MATERIALS. USE NEW MATCHING MATERIALS FOR RECONSTRUCTION AS REQUIRED. SEE THE ROOM FINISH SCHEDULE FOR ADDITIONAL COMMENTS REGARDING MATERIALS AND FINISHES. THE DESIGNATION 'CJ' INDICATES GYPSUM BOARD CONTROL JOINTS. WHERE INDICATED PROVIDE USG #093 ZINC CONTROL TYPICAL. INSTALL JOINT THROUGH THE FULL EXTENTS OF ANY GYPSUM CEILING OR BULKHEAD. WHERE THE GYPSUM CEILING COMPONENT MEETS A GYPSUM WALL, EXTEND THE CONTROL JOINT DOWN TO THE FLOOR TYPICAL. THE GENERAL CONTRACTOR WILL PROVIDE AND INSTALL ALL SUPPLEMENTAL AND/OR MISCELLANEOUS STEEL FRAMING AS REQUIRED BY THEMSELVES OR BY THEIR SUBCONTRACTORS FOR THE INSTALLATION OF THE EQUIPMENT SCHEDULED AND SPECIFIED. NOT ALL OF THE REQUIRED SUPPORT STEEL MAY BE DETAILED OR CALLED OUT FOR IN THESE DOCUMENTS. COORDINATE ALL REQUIREMENTS WITH THE SPECIFICATIONS, EQUIPMENT SUPPLIERS AND SUBCONTRACTORS. THERE WILL BE NO CHANGE ORDERS TO THE PROJECT FOR SUPPLEMENTAL STEEL WHERE OMISSIONS MAY OCCUR IN THE BIDDING DOCUMENTS. RATING PRIORITY 3 HOUR WALL 2 HOUR WALL 1 HOUR WALL SMOKE PARTITION NON RATED PARTITION 12345 HIGHER PRIORITY PARTITION GYPSUM BOARD CONTINUES THROUGH STUD CAVITY OF LOWER PRIORITY WALL LOWER PRIORITY PARTITION (LOWER NUMBER, HIGHER PRIORI TY) COMMISSION NUMBER DATE SHEET NUMBER SHEET TITLE CERTIFICATION The concepts, ideas, designs, plans, and details as shown on this document are the sole property of MSKTD & Associates, Inc., and were created, developed and presented for use on this specific project. None of the concepts, ideas, designs, plans, and details shall be used by any person, firm, or corporation for any purpose whatsoever, without the expressed written consent of MSKTD & Associates, Inc. The Owner shall be permitted to retain copies for information and reference in connection with this project. 1715 MAGNAVOX WAY FORT WAYNE, IN 46804 voice 260.432.9337 fax 260.436.2402 930 NORTH MERIDIAN INDIANAPOLIS, IN 46204 voice 317.917.1190 fax 317.822.6236 http://www.msktd.com ARCHITECTURE ENGINEERING INTERIOR DESIGN 6/30/2011 8:42:50 AM 11700 North Meridian Street, Carmel, IN T1.1 5186.1 6-30-11LDR Reception and C340 Renovation Title Sheet IU Health North Hospital IU Health North Hospital 11700 North Meridian Street, Carmel, Indiana 46032 LDR Reception and C340 Renovation E001 SYMBOLS AND ABBREVIATIONS E203 THRID FLOOR DEMOLITION AND LIGHTING PLANS E303 THIRD FLOOR POWER AND SYSTEMS PLANS M001 SYMBOLS AND ABBREVIATIONS M203 THIRD FLOOR DEMOLITION PLAN M303 THIRD FLOOR MECHANICAL PLAN M900 SCHEDULES AND DETAILS FP303 THIRD FLOOR FIRE PROTECTION PLAN T1.1 Title Sheet A0.1 Life Safety Plan A2.1 Floor Plans A7.1 Door and Room Finish Schedules and Misc. Details A10.1 Casework Plan and Elevations Architectural: Contacts General Demolition Notes General Construction Notes General Ceiling Plan Notes Rated Wall Priority Graphic Symbols Partition Types Mechanical: Electrical: Revisions: Date: By: 5 6 F F.8 G G.3 HJ Office C340A Bereavement C340B Clean Util C342 LDR C307 LDR C306 Tlt Pat C307A Ex Clos C344 Office C345 Med C343 Tlt Stf C346 LDR C311 LDR C310 LDR C309 LDR C308 Stair C1-3 Corridor C3C03 Corridor C3C02 Nurse Sta C3N01 Corridor C3C08 Nourish Ctr C341 Shaft SH09 Corridor C3C01 Corridor C3C09 Office Cxxx Registration Cxxxa ZONE 3.1 ZONE 3.2 7 Sleep Rm C352 On Call C351 Tlt. C351A Soil/Chute C350 N.C. C360 2HR EXIT ENCLOSURE 2HR SHAFT NURSE'S STATION 1HR HAZARDOUS ROOM SMOKE RESISTANT CORRIDOR 1HR SMOKE BARRIER Life Safety Plan Symbols OCCUPANCY: Health Care ZONE USE: Patient Sleeping, Outpatient CONSTRUCTION: I-332 ZONE DIMENSIONS: 219' AREA OF ZONE: 14,010 sq. ft. MANUAL FIRE ALARM: Provided SMOKE DET. & ALARM: Corridor System Provided AUDIBLE DEVICES: Provided VISUAL DEVICES: Provided AUTOMATIC SPRINKLERS: Sprinklers Throughout Building (Q.R.) TRAVEL DISTANCE TO SB: 90' TRAVEL DISTANCE TO EXIT: 132' ZONE 3.1 OCCUPANCY: Health Care ZONE USE: Patient Sleeping CONSTRUCTION: I-332 ZONE DIMENSIONS: 165' AREA OF ZONE: 15,039 sq. ft. MANUAL FIRE ALARM: Provided SMOKE DET. & ALARM: Corridor System Provided AUDIBLE DEVICES: Provided VISUAL DEVICES: Provided AUTOMATIC SPRINKLERS: Sprinklers Throughout Building (Q.R.) TRAVEL DISTANCE TO SB: 141' TRAVEL DISTANCE TO EXIT: 135' ZONE 3.2 NOTES: 1. EXISTING PERIMETER WALLS OF OFFICE C340A AND BEREAVEMENT C340B (EXISTING STORAGE) ARE NO LONGER REQUIRED TO BE 1 HR HAZARDOUS PER NEW FUNCTION OF ROOM. MAINTAIN RATING ON PORTIONS OF WALLS ALONG CLEAN UTILITY C342 AND SHAFT SH09. 2. SEE SPECIFICATIONS FOR INFECTIOUS CONTROL AND LIFE SAFETY REQUIREMENTS. *CONTRACTOR TO MAINTAIN 5'-0" CLEARANCE FOR VISITOR AND STAFF. ENTRY VESTIBULE TO REMAIN OPEN AT ALL TIMES. COORDINATE ANY AND ALL SHUT DOWNS WITH OWNER. COMMISSION NUMBER DATE SHEET NUMBER SHEET TITLE CERTIFICATION The concepts, ideas, designs, plans, and details as shown on this document are the sole property of MSKTD & Associates, Inc., and were created, developed and presented for use on this specific project. project. None of the concepts, ideas, designs, plans, and details shall be used by any person, firm, or corporation for any purpose whatsoever, without the expressed written consent of MSKTD & Associates, Inc. The Owner shall be permitted to retain copies for information and reference in connection with this project. 1715 MAGNAVOX WAY FORT WAYNE, IN 46804 voice 260.432.9337 fax 260.436.2402 930 NORTH MERIDIAN INDIANAPOLIS, IN 46204 voice 317.917.1190 fax 317.822.6236 http://www.msktd.com ARCHITECTURE ENGINEERING INTERIOR DESIGN 6/30/2011 8:47:56 AM 11700 North Meridian Street, Carmel, IN A0.1 5186.1 6-30-11LDR Reception and C340 Renovation Life Safety PlanIU Health North Hospital 1/8" = 1'-0" Life Safety Plan Revisions: Date: By: 5 6 F F.8 G G.3 HJ 2 3 4 4 3 1 1 5 6 7 8 9 9 10 Office C340A Bereavement C340B Clean Util C342 5 6 F F.8 G G.3 HJ LDR C307 LDR C306 Tlt Pat C307A Ex Clos C344 Office C345 Med C343 Tlt Stf C346 LDR C311 LDR C310 LDR C309 LDR C308 Stair C1-3 Corridor C3C03 Corridor C3C02 Nurse Sta C3N01 Corridor C3C08 Nourish Ctr C341 Shaft SH09 Corridor C3C01 Corridor C3C09 Office Cxxx Registration Cxxxa A10.1 1C340A 1 1 Cxxx 2 2 3 1.5B 1.5B 1.5B 1.5B 4 4 7' -10 3/8" Sleep Rm C352 On Call C351 N.C. C360 Soil/Chute C350 (CG) (CG) (CG) 5 5 6 F F.8 G G.3 HJ Bereavement C340B Office C340A Tlt Stf C346 Nourish Ctr C341 Clean Util C342 Med C343 Office C345 Ex Clos C344 Corridor C3C08 LDR C307 Tlt Pat Office C307A Cxxx Registration Cxxxa A.F.F. 8' -10" A.F.F. 8' -10" A.F.F. 8' -10" 1 2 3 56 1 4 44 Corridor C3C03 Corridor C3C02 Corridor C3C01 LDR C306 Sleep Rm C352 On Call C351 Soil/Chute C350 N.C. C360 Corridor C3C09 1' -8" 2" 5 5 1' -3 3/8" GENERAL NOTE: "(CG)" INDICATES CORNER GUARD TO BE FURNISHED AND INSTALLED BY CONTRACTOR. REFER TO DETAIL 4/A7.1. COMMISSION NUMBER DATE SHEET NUMBER SHEET TITLE CERTIFICATION The concepts, ideas, designs, plans, and details as shown on this document are the sole property of MSKTD & Associates, Inc., and were created, developed and presented for use on this specific project. None of the concepts, ideas, designs, plans, and details shall be used by any person, firm, or corporation for any purpose whatsoever, without the expressed written consent of MSKTD & Associates, Inc. The Owner shall be permitted to retain copies for information and reference in connection with this project. 1715 MAGNAVOX WAY FORT WAYNE, IN 46804 voice 260.432.9337 fax 260.436.2402 930 NORTH MERIDIAN INDIANAPOLIS, IN 46204 voice 317.917.1190 fax 317.822.6236 http://www.msktd.com ARCHITECTURE ENGINEERING INTERIOR DESIGN 6/30/2011 8:47:59 AM 11700 North Meridian Street, Carmel, IN A2.1 5186.1 6-30-11LDR Reception and C340 Renovation Floor Plans IU Health North Hospital 1/8" = 1'-0" Third Floor Demo Plan 1/8" = 1'-0" Third Floor Plan 1/8" = 1'-0" Third Floor Reflected Ceiling Plan Specific Demolition Notes 1 (INFECTIOUS CONTROL) CONSTRUCTION AND DUST SEPARATION WALL. 6" METAL STUD FRAMING W/5/8" VINYL FACED GYPSUM BOARD AND SOUND ATTENUATION BLANKET. EXTEND TO CEILING. TAPE SEAMS. REFER TO IU HEALTH'S MANDATORY CONTRACTOR'S ORIENTATION REQUIREMENTS AND SPECIFICATION SECTION. MAINTAIN A MINIMUM OF 5'-0" AT EXISTING CORRIDORS AND OWNER OCCUPIED SPACES FOR EGRESS. CONTRACTOR IS RESPONSIBLE FOR SUPPLYING AND DETERMINING WALL LOCATIONS AND NUMBER OF SIZES OF CONSTRUCTION DOORS WITHIN SEPARATION WALL. REPAIR FLOOR AND WALLS AS NEEDED AFTER REMOVAL OF WALL. 2 REMOVE PORTION OF EXISTING WALL AND BASE AS REQUIRED FOR NEW DOOR AND FRAME ASSEMBLY. SEE ARCHITECTURAL FLOOR PLAN FOR EXACT LOCATION. 3 REMOVE EXISTING WALL ASSEMBLY IN ITS ENTIRETY. 4 REMOVE EXISTING DECORATIVE CURTAIN AND ROD IN ITS ENTIRETY. 5 REMOVE AND RELOCATE EXISTING MED GASES TO OTHER SIDE OF EXISTING WALL INTO CLEAN UTILITY ROOM. PATCH AND REPAIR BOTHS SIDES OF WALL TO RECEIVE NEW FINISHES. REFER TO PLUMBING DRAWINGS. 6 REMOVE PORTION OF EXISTING HANDRAIL/BUMPRAIL AS REQUIRED FOR NEW OPENING. PATCH AS REQUIRED TO MATCH EXISTING. 7 PORTION OF EXISTING LAY-IN CEILING TO REMAIN (CROSS HATCHED AREA). REMOVE PORTION OF CEILING AS REQUIRED FOR INSTALLATION OF NEW WALL. REFER TO ARCHITECTURAL FLOOR AND CEILING PLANS. 8 REMOVE PORTION OF EXISTING 24x24 SUSPENDED CEILING GRID AND TILE IN THIS AREA. (SINGLE HATCHED AREA). 9 REMOVE EXISTING HARD CEILING IN ITS ENTIRETY. PREP TO RECEIVE NEW LAY-IN CEILING. COORDINATE WITH ARCHITECTURAL FLOOR AND CEILING PLANS. 10 REMOVE PORTION OF EXISTING FLOORING IN THIS AREA. (SINGLE HATCH AREA). Specific Plan Notes 1 (INFECTIOUS CONTROL) CONSTRUCTION AND DUST SEPARATION WALL. 6" METAL STUD FRAMING W/5/8" VINYL FACED GYPSUM BOARD AND SOUND ATTENUATION BLANKET. EXTEND TO CEILING. TAPE SEAMS. REFER TO IU HEALTH'S MANDATORY CONTRACTOR'S ORIENTATION REQUIREMENTS AND SPECIFICATION SECTION. MAINTAIN A MINIMUM OF 5'-0" AT EXISTING CORRIDORS AND OWNER OCCUPIED SPACES FOR EGRESS. CONTRACTOR IS RESPONSIBLE FOR SUPPLYING AND DETERMINING WALL LOCATIONS AND NUMBER AND SIZES OF CONSTRUCTION DOORS WITHIN SEPARATION WALL. REPAIR FLOOR AND WALLS AS NEEDED AFTER REMOVAL OF WALL. 2 HANDRAIL /BUMPRAIL. REFER TO 1/A7.1. 3 EXISTING MED GAS RELOCATED. REFER TO PLUMBING DRAWINGS. 4 ALIGN WALL. FLOOR AND CEILING OPENING. INFILL TO BE FLUSH AND LEVEL WITH EXISTING ADJACENT CONSTRUCTION. PREPARE TO RECEIVE NEW FINISHES. 5 PATCH AND REPAIR EXISTING HANDRAIL/BUMPRAIL AT NEW DOOR LOCATION. REFER TO 1/A7.1. Specific Reflected Ceiling Plan Notes 1 (INFECTIOUS CONTROL) CONSTRUCTION AND DUST SEPARATION WALL. 6" METAL STUD FRAMING W/5/8" VINYL FACED GYPSUM BOARD AND SOUND ATTENUATION BLANKET. EXTEND TO CEILING. TAPE SEAMS. REFER TO IU HEALTH'S MANDATORY CONTRACTOR'S ORIENTATION REQUIREMENTS AND SPECIFICATION SECTION. MAINTAIN A MINIMUM OF 5'-0" AT EXISTING CORRIDORS AND OWNER OCCUPIED SPACES FOR EGRESS. CONTRACTOR IS RESPONSIBLE FOR SUPPLYING AND DETERMINING WALL LOCATIONS AND NUMBER AND SIZES OF CONSTRUCTION DOORS WITHIN SEPARATION WALL. REPAIR FLOOR AND WALLS AS NEEDED AFTER REMOVAL OF WALL. 2 GYPSUM BOARD BULKHEAD WITH 3 5/8" METAL STUD AND 5/8" GYPSUM BOARD AT 7'-2" A.F.F. REFER TO 3/A7.1 & 10/A10.1. 3 GYPSUM BOARD BULKHEAD WITH 3 5/8" METAL STUD AND 5/8" GYPSUM BOARD AT 8'-0" A.F.F. REFER TO 2/A7.1. 4 NEW 24"x24" ACOUSTICAL CEILING TILE AND GRID. 5 EXISTING ACOUSTICAL CEILING TILE AND GRID TO REMAIN. MODIFY AS NEEDED FOR NEW WALL INSTALLATION. 6 EXISTING BULKHEAD TO REMAIN. Revisions: Date: By: FLOORS CARPET TILE CPT-1 LEES CARPETS, DESIGN CONNECT, 206 GOLDEN ROD. CPT-2 LEES CARPETS, DESIGN CONNECT, 228 CASTLE GREY. BASERUBBER BASE RB-1 JOHNSONITE -4" HIGH, COLOR: COVED #29 MOON ROCK. WALLS PAINTP-1 SHERWIN WILLIAMS. COLOR: #6378 CRISP LINEN. P-2 SHERWIN WILLIAMS. COLOR #6113 INTERACTIVE CREAM. P-3 MARTIN SENOUR PAINTS. COLOR #132-3 (RO) RUBIATE. VINYL WALL COVERING VWC-1 MDC WALLCOVERING. STYLE: VYCON OASIS. #Y449180A. COLOR: CLASSIC WHITE. CEILINGS ACOUSTICAL TILE AT-1 ARMSTRONG "DUNE, FINE-TEXTURED", 24"x24" #1772 WHITE. CASEWORK SOLID SURFACE SS-1 CORIAN -COUNTERTOPS, 3/4" THICK MATERIAL, COLOR: FOSSIL. SS-4 CORIAN -BASE, 1/4" THICK MATERIAL, COLOR: ANTHRACITE. WOODWD-1 ARCHITECTURAL GRADE CHERRY -CUT: QUARTER SLICED COLOR TO MATCH ARCHITECTURAL GRADE CHERRY (LIGHT). PLASTIC LAMINATE PL-1 PIONITE -SUEDE #WC431-S-MILLWORK CHERRY. MISCELLANEOUS TACK SURFACE TS-1 -MAHARAM -MEGA NANA POINT #901500, COLOR: 001 CREAM. TEXTURED GLASS TG-4 -INDIANA ART GLASS -3/8" THICK CUSTOM MOLDED GLASS -CLEAR. 1. 2. ALL BULKHEADS AND DRYWALL CEILING SHALL BE PAINTED (P-1) UNLESS OTHERWISE NOTED. 3. ALL METAL DOOR FRAMES SHALL BE (P-2). ALL CARPET TILE TO BE INSTALLED QUARTER TURN AS RECOMMENDED BY MANUFACTURER. 4. ALL WALLCOVERING INDICATED FOR REMOVAL AND REPLACED WITH NEW SHALL HAVE FULL HEIGHT VERTICAL SEAMS (NO HORIZONTAL). 1 2" DOOR WIDTH 2" 2" DOOR HEIGHT F LINE OF WALL BEYOND CHERRY HARDWOOD BUMP RAIL W/CLEAR FINISH AND 1/4" RADIUS EDGES. ANCHOR AT 4'-0" O.C. MAX. COUNTERSINK FASTNERS w/PLASTIC PLUGS TO MATCH RAIL. RUBBER BASE (RB-1) 2x6 FIRE TREATED WOOD BLOCKING BETWEEN STUDS OR 16 GA. 6" WIDE ANCHOR STRIPS. 1' -0" 8" 2" 4" 2" ONE PIECE SOLID CHERRY HARDWOOD HANDRAIL W/\CLEAR FINISH AND RETURN HANDRAIL TO WALL ENDS. (WITH 1/4" RADIUS ROUNDED EDGES AT BOTTOM) 1" 1 1/2" 1 1/2" 3 1/2" 1" 6" 2' -10" 2 PIECE ALUMINUM "T" BRACKETS (2"x1 1/2"x1/8") AT 4'-0" O.C. MAX.) 1" TYPICAL BUMPRAIL 1" TYPICAL HANDRAIL 1' -8" 5/8" GYPSUM BOARD (EXTEND 6" ABOVE CEILING) BRACE AS 3 5/8" METAL STUD REQUIRED SEE PLAN FOR HEIGHT REFER TO PARTITION TYPE FOR WALL CONSTRUCTION DOUBLE 3 5/8" METAL STUD FRAMING CONTINUOUS SEALANT (BOTH SIDES) HOLLOW METAL DOOR FRAME SEE SCHEDULE 2" REFER TO PARTITION TYPE FOR WALL CONSTRUCTION DOUBLE 3 5/8" METAL STUD FRAMING CONTINUOUS SEALANT (BOTH SIDES) HOLLOW METAL DOOR FRAME 5/8" GYPSUM BOARD (EXTEND 6" ABOVE CEILING) 3 5/8" METAL STUD SEE PLAN FOR HEIGHT 1' -3 3/8" WALL 6 J 1 2 3 6 J O.R. Class 1 C279 O.C. Class 2 C278 Corridor C2C15 Corridor C2C13 2 2 13 4 1 6 J O.R. Class 1 C279 O.C. Class 2 C278 Corridor C2C15 1 12 3 2" 2" METAL STUD FRAMING STRUCTURAL STUD AT CORNERS 12 GA. STAINLESS STEEL CORNER GUARD WITH RADIUSED CORNER AND EDGES. (HEIGHT TO BE 6'-8") 5/8" GYPSUM BOARD 1. 2. WRAP COLUMN WRAP WITH VWC-1. 3. REUSE EXISTING CARPET TILES, CPT-2. PROVIDE VWC-1 ON NORTH WALL FROM WEST SIDE OF COLUMN WRAP "F" TO :F.8". 4. PATCH, REPAIR AND PAINT ALL SURFACES OF PERIMETER EXISTING BULKHEAD (REFLECTED CEILING PLAN NOTE #6). 5. INFILL VCT FLOOR (AT REMOVED WALLS) WITH OWNER FURNISHED ATTIC STOCK. COMMISSION NUMBER DATE SHEET NUMBER SHEET TITLE CERTIFICATION The concepts, ideas, designs, plans, and details as shown on this document are the sole property of MSKTD & Associates, Inc., and were created, developed and presented for use on this specific project. None of the concepts, ideas, designs, plans, and details shall be used by any person, firm, or corporation for any purpose whatsoever, without the expressed written consent of MSKTD & Associates, Inc. The Owner shall be permitted to retain copies for information and reference in connection with this project. 1715 MAGNAVOX WAY FORT WAYNE, IN 46804 voice 260.432.9337 fax 260.436.2402 930 NORTH MERIDIAN INDIANAPOLIS, IN 46204 voice 317.917.1190 fax 317.822.6236 http://www.msktd.com ARCHITECTURE ENGINEERING INTERIOR DESIGN 6/30/2011 8:48:01 AM 11700 North Meridian Street, Carmel, IN A7.1 5186.1 6-30-11LDR Reception and C340 Renovation Door and Room Finish Schedules and Misc. Details IU Health North Hospital DOOR AND OPENING SCHEDULE Opening No. Door Frame Details Label Door Glass Hdw Size Mat. Ele. Mat. Ele. Head Jamb Sill . Set Remarks C340A 3'-0" x 7'-0" x 1 3/4" WD F HM 1 5/A7.1 6/A7.1 ------1 Cxxx 3'-0" x 7'-0" x 1 3/4" WD F HM 1 5/A7.1 6/A7.1 ------1 ROOM FINISH SCHEDULE Room No. Name Floor Base Walls Ceiling Type (see RCP for N E S W heights) Remarks C3C01 Corridor EXT. CPT-1/EXT. CPT-2 RB-1 ------VWC-1 EXT. ACT-1 1, 4 C3C03 Corridor EXT. CPT-2 RB-1 ------VWC-1 EXT. ACT-1 C3C08 Corridor EXT. CPT-2 RB-1 VWC-1 ------EXT. ACT-1 1, 3, 4 C278 O.C. Class 2 EXT. VCT RB-1 ------P-1 EXT. ACT-1 5, Alternate #1 C279 O.R. Class 1 EXT. VCT RB-1 ------P-1 EXT. ACT-1 5, Alternate #1 C340A Office CT-1 RB-1 P-1 P-1 P-1 P-1 ACT-1 C340B Bereavement EXT. VCT RB-1 --P-1 P-1 --EXT. ACT-1 Cxxx Office CPT-2 RB-1 P-1 P-1 P-1 P-1 ACT-1 2 Cxxxa Registration CPT-2 RB-1 VWC-1 --P-1 P-3 ACT-1 2 Color Legend General Finish Remarks Frame Elevation Door Elevation 1 1/2" = 1'-0" 1 Handrail /Bumprail 1 1/2" = 1'-0" 2 Gypsum Board Bulkhead 1 1/2" = 1'-0" 5 Head Detail 1 1/2" = 1'-0" 6 Jamb Detail 1 1/2" = 1'-0" 3 Gypsum Board Bulkhead 1/8" = 1'-0" Alt. #1 Second Floor Demo Plan 1/8" = 1'-0" Alt. #1 Second Floor Plan 1/8" = 1'-0" Alt. #1 Second Floor Reflected Ceiling Plan Specific Alt. #1 Demo Notes 1 REMOVE EXISTING MOVEABLE PARTITION. OVERHEAD TRACK TO REMAIN. 2 REMOVE EXISTING WALL. PATCH ADJACENT WALL TO RECEIVE NEW FINISHES. 3 REMOVE EXISTING PARTITION JAMB AND PREP TO RECEIVE NEW FINISHES. Specific Alt. #1 Plan Notes 1 PAINT ENTIRE WALL AFTER REQUIRED PATCHING. PROVIDE NEW RUBBER BASE. 2 CONTRACTOR TO ADJUST EXISTING OR REPLACE WITH 90 DEGREE CLOSER ON EXISTING DOOR. 3 REPAIR AND INFILL FLOOR WITH OWNER FUNRISHED, ATTIC STOCK VCT FLOOR TILE. 4 CONTRACTOR TO PROPERLY TERMINATE ALL ELECTRICAL ASSOCIATED WITH MOVEABLE PARTITION. Specific Alt. #1 Reflected Ceiling Plan Notes 1 EXISTING 2'x2' ACOUSTICAL TILE. 2 EXISTING OVERHEAD MOVEABLE PARTITION TRACK TO REMAIN. 3 REPAIR CEILING AT DEMOLISHED WALL LOCATION. 3" = 1'-0" 4 Corner Guard Detail Specific Finish Remarks Revisions: Date: By: CONTRACTOR SHALL PROVIDE WOOD BLOCKING AS REQUIRED FOR INSTALLATION OF ALL UPPER AND LOWER UNITS EDGE OF COUNTERTOP TO BE 1 1/2" THICK. CABINET MFG. SHALL COORDINATE WITH OWNER ALL LOCATIONS FOR " GROMMETS" QUANTITY WILL BE IDENTIFIED PER ELEVATION. ALL GROMMETS TO BE 3 1/2" DIA.WITH BLACK PLASTIC TRIM RING -LOCATE AT REAR OF COUNTER. OR AS DIRECTED BY OWNER. ALL EXPOSED ENDS AND BACKS OF CASEWORK TO BE FINISHED SAME AS BALANCE OF EXPOSED SURFACE, SEE FINISH SCHEDULE. APPLY 1" RAD. ON ALL OUTER CORNERS OF COUNTER TOPS, U.N.O. ALL END PANEL SUPPORT SHALL BE CONSTRUCTED W/1 1/2" LAMINATED PARTICLE BD. ALL COUNTER TOPS SHALL EXTEND 1" BEYOND FRONT OF CABINET DRAWER FACE. ALL DRAWERS AND DOOR HANDLES SHALL BE TYPE "STANLEY 4482" w/US 26D FINISH. ALL BASE CABINET DEPTH SHALL BE 24" UNLESS NOTED OTHERWISE ALL UPPER CABINET DEPTH SHALL BE 14" UNLESS NOTED OTHERWISE APPLY A 4" BACKSPLASH AT PERIMETER OF ALL COUNTER TOPS APPLY (1) ADJUSTABLE SHELF IN ALL BASE UNITS, AND (2) ADJUSTABLE SHELVES IN ALL. UPPER UNITS W/EXCEPTION OF SINK BASE UNITS. (UNLESS NOTED OTHERWISE). ALL SHELVES IN CASEWORK TO BE ADJUSTABLE ON 1" CENTERS VERTICALLY. ALL BASE UNITS SHALL HAVE A 4" H. x 3" D. TOE SPACE WITH RUBBER BASE BY FLOORING CONTRACTOR. BASE TO EXTEND TO ALL EXPOSED SIDES OF CASEWORK. REFER TO FLOOR PLAN FOR ALL WALL PARTITION TYPES PAPER TOWEL DISPENSER LOCATED AT EVERY SINK. SUPPLIED BY OWNER, INSTALLED BY G.C. " L " = DOOR/DRAWER TO BE LOCKED WITH KEY CYLINDER. COORDINATE WITH OWNER ON KEYING REQUIREMENTS " F " = FILE DRAWER, INTERIOR DIMENSIONS SHALL MEET STANDARD FILE DRAWER DIMENSIONS. INSTALL HANGING FILE HARDWARE. " UL " = UNDER UPPER CABINET LIGHT, REFER TO ELECTRICAL DRAWINGS, APPLY 2" LAMINATED APRON. " S " = STRUCTURAL SUPPORT FOR COUNTER AND OR RECEPTION DESK. REFER TO " AP " = REMOVABLE ACCESS PANEL. PROVIDE COUNTERSUNK ANCHORS. " K " = KEYBOARD TRAYS PROVIDED BY OWNER -30" WIDE " G " = GROMMETS, VERIFY LOCATION WITH OWNER CABINET MFG. SHALL FIELD VERIFY ALL WALL DIMENSIONS PRIOR TO FABRICATION. ALL GENERAL CASEWORK CASEWORK NOTES APPLY TO ALL CASEWORK THROUGH OUT SET FOR ALL FILES DESIGNATED "BY OWNER" -CONTRACTOR TO VERIFY ACTUAL HEIGHT OF FILES TO BE PURCHASED FOR COORDINATION, IF USED AS SUPPORT FOR COUNTER TOP INSTALL CLEAR SEALANT CONTINUOUS BETWEEN TOP OF BACKSPLASH AND WALL. ALL HARDWARE FOR ANCHORING/SUPPORTING CASEWORK SHALL BE CONCEALED. PROVIDE 2X2 WOOD BLOCKING CONTINUOUS AT PERIMETER FOR COUNTERTOP/SHELF SUPPORT -PAINT TO MATCH WALL. ALL COUNTERTOPS WITHOUT BACKSPLASH SHALL BE SCRIBED TO ADJACENT WALLS/CASEWORK. 4 DIGIT NUMBER ABOVE OR BELOW CASEWORK REFERS TO HEIGHT AND WIDTH OF UNIT. FILLERS PANELS BY CABINET MANUFACTURER TO MATCH CABINETS. PROVIDE AND INSTALL. 5 F.8 2 A10.1 A10.1 3 A10.1 4 Registration Cxxxa 2' -1" 2' -6" 1' -8 3/4" 1' -10 1/2" 1 1/2" 2' -5 13/16" 7' -10 3/8" 8' -1 3/4" 11" 80.00° RADIUS CORNERS 1.5B 1.5B 5 A10.1 6 A10.1 G G L F 1' -8" 2" 2' -6" 2' -0" 2' -6" 8' -10" GYPSUM BULKHEAD FILLER 2' -9" 2' -9" FILLER 4' -3 3/4" 1' -6" PRINTER SHELF W/HEAVY DUTY HAFELE GUIDES 18" DEEP CABINET ((PL-1) (RB-1) S L L L L (SS-1) 4"h BACKSPLASH 10 A10.1 UL UL G 8' -10" 1' -10 1/2" 1' -9 9/16" 3' -8 1/16" 2' -6" 1' -0" 4' -6" 10" GYPSUM BOARD BULKHEAD (SS-1) (WD-1) S (PL-1) (RB-1) 1 1/2" 1 1/2" 4"h BACKSPLASH G (TS-1) 2' -6" 1' -0" 4' -6" 2' -0" GYPSUM BOARD BULKHEAD (SS-1) (TG-4) (WD-1) (SS-4)1 1/2" 1 1/2" 8' -0" 1/4" 1 1/2" EQ. 1/4" EQ. 1/2" 4" 3/4" 3/4" 3/4" 5 1/2" 1 1/2" 1' -8 3/4" 7 3/4" 2' -6" SOLID SURFACE (SS-4) 3/4" PLYWOOD CHERRY WOOD VENEER (WD-1) (QUARTER SAWN) ON 3/4" PLYWOOD 2x6 WOOD STUD RUBBER BASE (RB-1) PROVIDE REMOVABLE ACCESS PANEL 3/4" PLYWOOD INSTALL (PL-1) ON EXPOSED INSIDE BACK PANELS 3/4" PLYWOOD SUPPORT W/(PL-1) ON ALL EXPOSED SURFACES SOLID SURFACE (SS-1) 2' -6" 8 A10.1 1 1/2" 10 1/2" 1/4" 1 1/2" EQ. 1/4" EQ. 1/2" 4" 3/4" 3/4" 3/4" 5 1/2" SOLID SURFACE (SS-4) 3/4" PLYWOOD CHERRY WOOD VENEER (WD-1) (QUARTER SAWN) ON 3/4" PLYWOOD RUBBER BASE (RB-1) PROVIDE REMOVABLE ACCESS PANEL 3/4" PLYWOOD INSTALL (PL-1) ON EXPOSED INSIDE BACK PANELS 3/4" PLYWOOD SUPPORT W/(PL-1) ON ALL EXPOSED SUFACES SOLID SURFACE (SS-1) 2x6 WOOD STUD A10.1 7 8 A10.1 9 A10.1 2' -6" 1' -7" 11" 11" STAINLESS STEEL CHANNEL WITH RUBBER STOP 1" STAINLESS STEEL CYLINDER TO SUPPORT SOLID SURFACE TOP 3/8" TEXTURED GLASS (TG-4) STAINLESS STEEL CHANNEL 1 1/2" 1 1/4" 2 1/2" 1 1/2" 1 1/2" 1/4" REVEAL SOLID SURFACE (SS-1) 1/8" MIRROR TO 1/4" PLYWOOD, MIRROR TO FACE DECORATIVE GLASS 3/4" PLYWOOD 1/2" HOMOSOTE -WRAPPED WITH TACK SURFACE (TS-1) SOLID SURFACE (SS-1) 1' -0" A10.1 11 R 1/4" 1 1/4" 1/4" 105.00° GYPSUM BOARD BULKHEAD: 2 1/2" METAL STUD W/5/8" GYPSUM BOARD (ONE SIDE) SCRIBE TO WALL CABINET DOOR 3/8" 1" CHERRY WOOD VENEER (WD-1) (QUARTER SAWN) ON 3/4" PLYWOOD 1/2" HOMOSOTE -WRAP WITH TACK SURFACE (TS-1) 3/4" PLYWOOD 1/8" MIRROR TO 1/4" PLYWOOD, MIRROR TO FACE DECORATIVE GLASS 1" STAINLESS STEEL CYLINDER TO SUPPORT SOLID SURFACE TOP 3/8" TEXTURED GLASS (TG-4) SOLID SURFACE (ABOVE) 11" 4" 4 5/8" 1/4" 1 1/2" 1 1/2" 1 1/2" SOLID SURFACE COUNTER (ABOVE) 3/4" PLYWOOD (PL-1), INSTALL ON EXPOSED INSIDE BACK WALLS CHERRY WOOD WOOD VENEER (WD-1) (QUARTER SAWN) ON 3/4" PLYWOOD 2x6 WOOD STUD 1 1/2" 1 1/2" COMMISSION NUMBER DATE SHEET NUMBER SHEET TITLE CERTIFICATION The concepts, ideas, designs, plans, and details as shown on this document are the sole property of MSKTD & Associates, Inc., and were created, developed and presented for use on this specific project. None of the concepts, ideas, designs, plans, and details shall be used by any person, firm, or corporation for any purpose whatsoever, without the expressed written consent of MSKTD & Associates, Inc. The Owner shall be permitted to retain copies for information and reference in connection with this project. 1715 MAGNAVOX WAY FORT WAYNE, IN 46804 voice 260.432.9337 fax 260.436.2402 930 NORTH MERIDIAN INDIANAPOLIS, IN 46204 voice 317.917.1190 fax 317.822.6236 http://www.msktd.com ARCHITECTURE ENGINEERING INTERIOR DESIGN 6/30/2011 8:48:05 AM 11700 North Meridian Street, Carmel, IN A10.1 5186.1 6-30-11LDR Reception and C340 Renovation Casework Plan and Elevations IU Health North Hospital General Casework Notes 1/2" = 1'-0" 1 Enlarged Casework Plan 1/2" = 1'-0" 2 Casework Elevation 1/2" = 1'-0" 3 Casework Elevation 1/2" = 1'-0" 4 Casework Elevation 1" = 1'-0" 5 Casework Section 1" = 1'-0" 6 Casework Section 3" = 1'-0" 7 Casework Detail 12" = 1'-0" 11 Edge Profile 3" = 1'-0" 10 Cabinet/Soffit Detail 1 1/2" = 1'-0" 9 Enlarged Plan Detail 1 1/2" = 1'-0" 8 Enlarged Plan Detail Revisions: Date: By: NORTH NOTE: DIMENSIONS SHOWN ARE INSIDE CLEAR DIMENSIONS. IF DUCT IS LINED, INCREASE DUCT SIZE TO ACCOMMODATE LINING. FD PP ABBREVIATIONS: ABBREVIATIONS: MONITOR/SHEETMETAL SYMBOLS: SHEETMETAL SYMBOLS: EQUIPMENT DESIGNATIONS: CONTROL SYMBOLS: PIPING SYMBOLS AND ABBREVIATIONS: GENERAL NOTES: DRAWING SYMBOLS: NOTE DESIGNATIONS: SPECIAL TERMINOLOGY: PIPING SYMBOLS AND ABBREVIATIONS: TF/T TS TS DPT PS FS PS FM W L EQUIPMENT MARK NUMBER (REFER TO SCHEDULES) EQUIPMENT NUMBER EQUIPMENT ABBREVIATION AHU-12 THERMOSTAT THERMOSTAT WITH GUARD THERMOSTAT FOR NIGHT SETBACK ROOM SENSOR ROOM SENSOR WITH GUARD HUMIDISTAT/HUMIDITY SENSOR SENSOR STATIC PRESSURE SENSOR CARBON DIOXIDE SENSOR CARBON MONOXIDE SENSOR SPEED CONTROLLER SILICON CONTROLLED RECTIFIER MANUAL MOTOR STARTER/SWITCH MONITOR/CONTROL EQUIPMENT EQUIPMENT THAT IS BEING MONITORED/CONTROLLED AHU-12 T BFW CR BFW BOILER FEEDWATER CR CONDENSER RETURN CS CONDENSER SUPPLY CWR CHILLED WATER RETURN CWS CHILLED WATER SUPPLY D DRAIN LINE DTR DUAL TEMPERATURE RETURN DTS DUAL TEMPERATURE SUPPLY HPR HIGH PRESSURE CONDENSATE RETURN HPS HIGH PRESSURE STEAM (ABOVE 60 PSIG) HR HEAT PUMP CONDENSER RETURN HS HEAT PUMP CONDENSER SUPPLY HWR HEATING WATER RETURN HWS HEATING WATER SUPPLY LPR LOW PRESSURE CONDENSATE RETURN LPS LOW PRESSURE STEAM (1 TO 15 PSIG) MPR MEDIUM PRESSURE CONDENSATE RETURN MPS MEDIUM PRESSURE STEAM (16 TO 60 PSIG) MU MAKE-UP WATER PD PUMP DISCHARGE (CONDENSATE) RHG REFRIGERANT HOT GAS RL REFRIGERANT LIQUID RS REFRIGERANT SUCTION SV SAFETY RELIEF VENT LINE V VENT LINE CS CWR CWS D DTR DTS HPR HPS HR HS HWR HWS LPR LPS MPR MPS MU PD RHG RL RS SV V T RS SHC1 $ G T N T G RS PS SC C2 SCR //HPS HPS HIGH PRESSURE STEAM (UNDERGROUND) //CWR CWR CHILLED WATER RETURN (UNDERGROUND) //CWS CWS CHILLED WATER SUPPLY (UNDERGROUND) //PD PD PUMP DISCHARGE (CONDENSATE) (UNDERGROUND) SMS SMS SNOW MELT SUPPLY (GLYCOL) SMR SMR SNOW MELT RETURN (GLYCOL) TO RECTANGULAR DUCT FLEXIBLE DUCT CONNECTION SIDEWALL MOUNTED S/A GRILLE/REGISTER 3-WAY THROW S/A DIFFUSER 2-WAY OPPOSITE THROW S/A DIFFUSER ACCESS DOOR MOUNTED IN MOST DIFFUSER OR LINEAR BAR GRILLE FLEXIBLE DUCT TO PLENUM OF SLOT SIDEWALL MOUNTED R/A, E/A, T/A, RF/A R/A, E/A, T/A, RF/A GRILLE/REGISTER FLEXIBLE DUCT TO SQUARE S/A DIFFUSER SOUND ATTENUATOR AD SPIN-IN FITTING FOR ROUND TO RECTANGULAR DUCT TERMINAL BOX WITH ELECTRIC REHEAT TERMINAL BOX DUCT MOUNTED ELECTRIC DUCT HEATER DUCT MOUNTED HYDRONIC REHEAT COIL AIR FLOW MEASURING STATION WITH WITH ACCESS DOOR SMOKE DAMPER WITH ACCESS DOOR FIRE DAMPER WITH ACCESS DOOR GRAVITY BACKDRAFT DAMPER WITH ACCESS DOOR FSD AFMS SD FD BDD DUCT CONNECT TO EXISTING ON NEW PLAN DUCT DEMOLISH TO POINT ON DEMOLITION PLAN DUCT CAP ON DEMOLITION PLAN RECTANGULAR TO ROUND OR FLAT OVAL DUCT TRANSITION (ALL DUCT TYPES AND PRESSURE CLASSES) (ALL DUCT TYPES AND PRESSURE CLASSES) (LOW PRESSURE DUCT ONLY) CONICAL FITTING FOR ROUND OR FLAT OVAL TO ROUND OR FLAT OVAL DUCT DUCT CAP MANUAL VOLUME DAMPER (ALL PRESSURE CLASSES) CONCENTRIC DUCT TRANSITION ECCENTRIC DUCT TRANSITION CONICAL FITTING FOR ROUND OR FLAT OVAL OVAL DUCT (ALL PRESSURE CLASSES -NO EXTRACTOR) 45° FITTING FOR RECTANGULAR TO RECTANGULAR DUCT (ALL DUCT TYPES AND PRESSURE CLASSES) RADIUS DUCT ELBOW (CENTERLINE RADIUS 1.5 x W) (RECTANGULAR LOW PRESSURE DUCT ONLY) (RECTANGULAR LOW PRESSURE TRANSFER AIR DUCT ONLY) 90° DUCT ELBOW WITH TURNING VANES 90° DUCT ELBOW WITHOUT TURNING VANES DUCT DROP IN DIRECTION OF FLOW DUCT RISE IN DIRECTION OF FLOW FLAT OVAL R/A, E/A, T/A, RF/A DUCT DOWN FLAT OVAL R/A, E/A, T/A, RF/A DUCT FLAT OVAL S/A, O/A DUCT TURNED UP FLAT OVAL S/A, O/A DUCT DOWN THROUGH DR TURNED UP PENETRATING STRUCTURE ABOVE RECTANGULAR R/A, E/A, T/A, RF/A DUCT DOWN ROUND R/A, E/A, T/A, RF/A DUCT DOWN THROUGH FLOOR OR DROP TO EQUIPMENT RECTANGULAR R/A, E/A, T/A, RF/A DUCT ROUND R/A, E/A, T/A, RF/A DUCT TURNED UP PENETRATING STRUCTURE ABOVE (SIDE SHOWN IS FIRST DIMENSION) RECTANGULAR DUCT, DIMENSION IN INCHES (SIDE SHOWN IS FIRST DIMENSION) ROUND DUCT, DIMENSION IN INCHES FLAT OVAL DUCT, DIMENSION IN INCHES ROUND S/A, O/A DUCT DOWN THROUGH RECTANGULAR S/A, O/A DUCT DOWN ROUND S/A, O/A DUCT TURNED UP RECTANGULAR S/A, O/A DUCT TURNED 12x6 12x6 12"DROP IN DIRECTION OF FLOW RECTANGULAR S/A, O/A DUCT RISE IN DIRECTION OF FLOW RECTANGULAR S/A, O/A DUCT THROUGH FLOOR OR DROP TO EQUIPMENT DUCT RISE IN DIRECTION OF FLOW DUCT DROP IN DIRECTION OF FLOW RECTANGULAR R/A, E/A, T/A, RF/A RECTANGULAR R/A, E/A, T/A, RF/A PENETRATING STRUCTURE ABOVE FLOOR OR DROP TO EQUIPMENT ROUND S/A, O/A DUCT DROP ROUND S/A, O/A DUCT RISE IN DIRECTION OF FLOW UP PENETRATING STRUCTURE ABOVE THROUGH FLOOR OR DROP TO EQUIPMENT DROP IN DIRECTION OF FLOW ROUND R/A, E/A, T/A, RF/A DUCT ROUND R/A, E/A, T/A, RF/A DUCT PENETRATING STRUCTURE ABOVE FLOOR OR DROP TO EQUIPMENT FLAT OVAL S/A, O/A DUCT FLAT OVAL S/A, O/A DUCT DROP IN DIRECTION OF FLOW IN DIRECTION OF FLOW RISE IN DIRECTION OF FLOW RISE IN DIRECTION OF FLOW TURNED UP PENETRATING STRUCTURE ABOVE THROUGH FLOOR OR DROP TO EQUIPMENT DUCT RISE IN DIRECTION OF FLOW DUCT DROP IN DIRECTION OF FLOW FLAT OVAL R/A, E/A, T/A, RF/A FLAT OVAL R/A, E/A, T/A, RF/A DIFFUSER/GRILLE/REGISTER DESIGNATION (REFER TO SCHEDULES) CFM MARK LETTER A10-350 WITH ACCESS DOOR (DASHED LINES INDICATE 42" CLEARANCE) FLEXIBLE DUCT TO ROUND S/A DIFFUSER 2-WAY CORNER THROW S/A DIFFUSER ROUND S/A DIFFUSER 4-WAY THROW SQUARE S/A DIFFUSER (ALL PRESSURE CLASSES) (ALL PRESSURE CLASSES) STATIC PRESSURE SENSOR WITH ACCESS DOOR PS WITH ACCESS DOOR AUTOMATIC MOTORIZED DAMPER COMBINATION FIRE AND SMOKE DAMPER WITH ACCESS DOOR (DASHED LINES INDICATE 42" CLEARANCE) ACCESS DOOR ACCESSIBLE SIDE OF DUCT (DASHED LINES INDICATE 24" CLEARANCE) M GRILLE/REGISTER DUCT SMOKE DETECTOR WITH ACCESS DOOR DD AC AIR COMPRESSOR ACCU AIR COOLED CONDENSING UNIT ACD AIR COMPRESSOR DRYER ACU AIR CURTAIN UNIT AD ACCESS DOOR OR AREA DRAIN AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE AFMS AIR FLOW MEASURING STATION AFUE ANNUAL FUEL UTILIZATION EFFICIENCY AHU AIR HANDLING UNIT AP ACCESS PANEL APD AIR PRESSURE DROP (INCHES OF WC) APPROX APPROXIMATELY ARCH ARCHITECT OR ARCHITECTURAL AS AIR SEPARATOR AWT AVERAGE WATER TEMPERATURE BDD BACKDRAFT DAMPER BFG BELOW FINISHED GRADE BFP BACKFLOW PREVENTER BFS BOILER FEEDWATER SYSTEM bHP BRAKE HORSEPOWER BOD BOTTOM OF DUCT BOP BOTTOM OF PIPE BOS BOTTOM OF STEEL/STRUCTURE BTUH BRITISH THERMAL UNIT PER HOUR CAF COMBUSTION AIR FAN CAP CAPACITY CAV CONSTANT AIR VOLUME CC COOLING COIL CFH CUBIC FEET PER HOUR CFM CUBIC FEET PER MINUTE CH CHILLER CKT CIRCUIT CO CLEAN OUT OR CARBON MONOXIDE CO2 CARBON DIOXIDE CONT CONTINUATION OR CONTINUED COP COEFFICIENT OF PERFORMANCE CP CONDENSER WATER PUMP CT COOLING TOWER CUH CABINET UNIT HEATER CV CONVECTOR CW CHILLED WATER D DEEP OR DEHUMIDIFIER DA DEAERATOR DACU DUCTLESS AIR CONDITIONING UNIT DB DRY BULB DDC DIRECT DIGITAL CONTROL DDTB DUAL DUCT TERMINAL BOX DEG F DEGREES FAHRENHEIT DEMO DEMOLITION OR DEMOLISH DG DOOR GRILLE DIA DIAMETER DN DOWN DPT DIFFERENTIAL PRESSURE TRANSMITTER DTF DOWN THROUGH FLOOR DTR DOWN THROUGH ROOF DWG DRAWING DX DIRECT EXPANSION E EAST E/A EXHAUST AIR EA EACH EAT ENTERING AIR TEMPERATURE EBB ELECTRIC BASEBOARD EC ELECTRICAL CONTRACTOR OR COMBUSTION EFFICIENCY ECH ELECTRIC CABINET HEATER OR ELECTRIC CEILING HEATER EDB ENTERING DRY BULB EDH ELECTRIC DUCT HEATER EER ENERGY EFFICIENCY RATIO EF EXHAUST FAN OR ENERGY FACTOR ELEV ELEVATION ENT ENTERING EOM END OF MAIN ERU ENERGY RECOVERY UNIT ERV ENERGY RECOVERY VENTILATOR ESP EXTERNAL STATIC PRESSURE ET EXPANSION TANK OR THERMAL EFFICIENCY EUH ELECTRIC UNIT HEATER EWB ENTERING WET BULB EWH ELECTRIC WALL HEATER EWT ENTERING WATER TEMPERATURE °F DEGREES FAHRENHEIT F FILTER OR FURNACE FC FLUID COOLER FCU FAN COIL UNIT FD FIRE DAMPER OR FLOOR DRAIN FSD COMBINATION FIRE AND SMOKE DAMPER FFE FINISHED FLOOR ELEVATION FLA FULL LOAD AMPS FLR FLOOR FPC FIRE PROTECTION CONTRACTOR FPM FEET PER MINUTE FPTB FAN POWERED TERMINAL BOX FT FEET OR FLASH TANK FTR FINNED TUBE RADIATION GAL GALLON GC GENERAL CONTRACTOR GPD GALLONS PER DAY GPH GALLONS PER HOUR GPM GALLONS PER MINUTE GV GRAVITY VENTILATOR H HIGH OR HUMIDIFIER HC HEATING COIL HD HOOD HEPA HIGH EFFICIENCY PARTICULATE AIR HOA HAND-OFF-AUTOMATIC HP HORSEPOWER OR HEAT PUMP HR HOUR HW HEATING WATER HX HEAT EXCHANGER HZ HERTZ (CYCLE PER SECOND) IE INVERT ELEVATION IFB INTEGRAL FACE AND BYPASS IN INCH IN HG INCHES OF MERCURY (PRESSURE) KW KILOWATT L LONG OR LOUVER LAT LEAVING AIR TEMPERATURE LBS POUNDS LRA LOCKED ROTOR AMPS LWT LEAVING WATER TEMPERATURE M/A MIXED AIR MAT MIXED AIR TEMPERATURE MAX MAXIMUM MBH THOUSAND BRITISH THERMAL UNIT PER HOUR MC MECHANICAL CONTRACTOR MCA MINIMUM CIRCUIT AMPS MECH MECHANICAL MFR MANUFACTURER MFS MAXIMUM FUSE SIZE MIN MINIMUM MOCP MAXIMUM OVERCURRENT PROTECTION MD MOTORIZED DAMPER MZU MULTIZONE UNIT N NORTH NA NOT APPLICABLE NC NORMALLY CLOSED OR NOISE CRITERIA NEC NATIONAL ELECTRICAL CODE NFPA NATIONAL FIRE PROTECTION ASSOCIATION NO NORMALLY OPEN OR NUMBER NOM NOMINAL NPT NOMINAL PIPE THREAD NS NON SLAM NTS NOT TO SCALE O/A OUTDOOR AIR OAT OUTDOOR AIR TEMPERATURE OBD OPPOSED BLADE DAMPER P PUMP P&T PRESSURE AND TEMPERATURE PBD PARALLEL BLADE DAMPER PC PLUMBING CONTRACTOR PD PRESSURE DROP OR PRESSURE PRESSURE DIFFERENCE PH PHASE PHC PREHEAT COIL PRESS PRESSURE SPRS STEAM PRESSURE REDUCING STATION SPRV STEAM PRESSURE REDUCING VALVE PSF POUNDS PER SQUARE FOOT PSI POUNDS PER SQUARE INCH PSIA POUNDS PER SQUARE INCH ABSOLUTE PSIG POUNDS PER SQUARE INCH GAUGE PTAC PACKAGED TERMINAL AIR CONDITIONER PVC POLYVINYL CHLORIDE QTY QUANTITY R/A RETURN AIR RCP RADIANT CEILING PANEL RD ROOF DRAIN REFRIG REFRIGERANT RF RETURN FAN RH RELATIVE HUMIDITY RHC REHEAT COIL RLA RUNNING LOAD AMPS RPM REVOLUTIONS PER MINUTE RTU ROOFTOP UNIT RV RELIEF VALVE (HYDRONIC) S SOUTH S/A SUPPLY AIR SA SOUND ATTENUATOR SD SMOKE DAMPER SEER SEASONAL ENERGY EFFICIENCY RATIO SENS SENSIBLE SF SQUARE FEET OR SUPPLY FAN SHT SHEET SM SECONDARY METER SHEET METAL AND AIR CONDITIONING SMC SHEETMETAL CONTRACTOR SP STATIC PRESSURE SPEC(S) SPECIFICATION(S) SQ SQUARE SRV SAFETY RELIEF VALVE (STEAM) SS STAINLESS STEEL SST SATURATED SUCTION TEMPERATURE STAT THERMOSTAT T&P TEMPERATURE AND PRESSURE T/A TRANSFER AIR TB TERMINAL BOX TC TEMPERATURE CONTROL TCC TCC TEMPERATURE CONTROL CONTRACTOR TCP TEMPERATURE CONTROL PANEL TEMP TEMPERATURE TOD TOP OF DUCT TOP TOP OF PIPE TOS TOP OF STEEL/STRUCTURE TSP TOTAL STATIC PRESSURE TYP TYPICAL UH UNIT HEATER UNO UNLESS NOTED OTHERWISE UTF UP THROUGH FLOOR UTR UP THROUGH ROOF UV UNIT VENTILATOR V VENT OR VOLTS VAV VARIABLE AIR VOLUME VB VACUUM BREAKER VD VOLUME DAMPER VFD VARIABLE FREQUENCY DRIVE VTR VENT THRU ROOF W WATT OR WEST OR WIDE WB WET BULB WC WATER COLUMN (PRESSURE) WPD WATER PRESSURE DROP (FEET OF WC) / DIAMETER OR PHASE # POUND OR NUMBER CONTRACTORS NATIONAL ASSOCIATION FLAT OVAL DUCT ACC AIR COOLED CONDENSER 1 CENTERLINE SMACNA RF/A RELIEF AIR ADA AMERICANS WITH DISABILITIES ACT CRAC COMPUTER ROOM AIR CONDITIONING UNIT AMERICAN SOCIETY OF MECHANICAL ENGINEERS SOLAR HEAT GAIN COEFFICIENT THERMAL RESISTANCE POOL DEHUMIDIFICATION UNIT INTEGRATED PART LOAD VALUE AMERICAN SOCIETY FOR TESTING AND MATERIALS AIR MOVEMENT AND CONTROL ASSOCIATION INTERNATIONAL IPLV USHGC RPDU THERMAL CONDUCTANCE ASME ASTM AMCA U.S. DEPARTMENT OF ENERGY COOLING TECHNOLOGY INSTITUTE DOE CTI AMERICAN NATIONAL STANDARDS INSTITUTE AIR-CONDITIONING AND REFRIGERATION INSTITUTE ASHRAE ARI ANSI AMERICAN SOCIETY OF HEATING, REFRIGERATING AND AIR-CONDITIONING ENGINEERS, INC. °C DEGREES CELSIUS DEG C DEGREES CELSIUS EFB EXTERNAL FACE AND BYPASS KWH KILOWATT HOUR PRV PRESSURE REDUCING VALVE (HYDRONIC) PSV PRESSURE SUSTAINING VALVE (HYDRONIC) TSU THERMAL STORAGE UNIT HVU HEATING AND VENTILATING UNIT C COMMON (PORT TAG ON VALVE) SL STANDBY LOSS ABBREV ABBREVIATION(S) FM FACTORY MUTUAL KEC KITCHEN EQUIPMENT CONTRACTOR DD DUCT SMOKE DETECTOR GEF GENERAL EXHAUST FAN KEF KITCHEN EXHAUST FAN LF LINEAL FEET B BOILER SEF SMOKE EXHAUST FAN CWP CHILLED WATER PUMP BCU BLOWER COIL UNIT HWP HEATING WATER PUMP SCP STEAM CONDENSATE PUMP SCR STEAM CONDENSATE RECEIVER ST STORAGE TANK IH INFRARED HEATER FPI COIL FINS PER SQUARE INCH BDS BLOWDOWN SEPARATOR HWP HEATING WATER PUMP AF AIRFOIL BI BACKWARD INCLINED DWDI DOUBLE WIDTH DOUBLE INLET SWSI SINGLE WIDTH SINGLE INLET INLET ORD OVERFLOW ROOF DRAIN FOR FOV FOS A FD RD FOV FOR FOS A G SCW GDCW COMPRESSED AIR ROOF DRAIN FLOOR DRAIN FUEL OIL VENT FUEL OIL SUPPLY FUEL OIL RETURN DOMESTIC SOFT COLD WATER NATURAL GAS DOMESTIC COLD RAW WATER CO CO CLEANOUT -DCW -SCW AD AREA DRAIN FS FLOOR SINK ALL SYMBOLS AND ABBREVIATIONS PRESENTED ON THIS SHEET MAY OR MAY NOT BE USED ON THE FOLLOWING SHEETS. THESE SYMBOLS ON THE MECHANICAL, ELECTRICAL, PLUMBING , FIRE PROTECTION AND MEDICAL GAS SHEETS INDICATE ELECTRICAL EQUIPMENT PANELBOARDS, SWITCHBOARDS AND MOTOR CONTROL CENTERS. THE CONTRACTOR SHALL MAINTAIN A MINIMUM OF 42" FRONT CLEAR WORKING SPACE AND, IN ADDITION, A CLEAR DEDICATED SPACE EXTENDING FROM FLOOR TO STRUCTURAL CEILING ABOVE WITH A WIDTH AND DEPTH OF THAT EQUIPMENT, IN ACCORDANCE WITH THE LATEST REVISION OF NFPA 70, NATIONAL ELECTRICAL CODE. REFERENCE SECTIONS 110 AND 384 OF THE NEC. NO PIPING, DUCT OR EQUIPMENT FOREIGN TO THE ELECTRICAL EQUIPMENT OR ARCHITECTURAL APPURTENANCES, SHALL BE PERMITTED TO BE INSTALLED IN, ENTER OR PASS THROUGH, SUCH CLEAR SPACES OR ROOMS. PIPES SHOWN ARE IN THE CEILING SPACE OF THE LEVEL/FLOOR ON WHICH THEY APPEAR, UNLESS OTHERWISE NOTED. EXISTING TO REMAIN WORK IS SHOWN WITH THIN/LIGHT SOLID LINES. EXISTING TO BE REMOVED OR RELOCATED WORK IS SHOWN WITH THICK/DARK DOTTED LINES. NEW OR RELOCATED WORK IS SHOWN WITH THICK/DARK SOLID LINES. ITEM PENETRATING STRUCTURAL PLANE ABOVE. ITEM PENETRATING STRUCTURAL PLANE BELOW. ITEM INCREASES ELEVATION BUT DOES NOT PENETRATE STRUCTURAL PLANE ABOVE. ITEM DECREASES ELEVATION BUT DOES NOT PENETRATE STRUCTURAL PLANE BELOW. SECTION/ELEVATION DIRECTION GENERAL INFORMATION AS INDICATED ON A SHEET. APPLIES TO ENTIRE SHEET. SPECIFIC INFORMATION AS INDICATED ON A SHEET. LEADER LINE OF PLAN NOTE REFERENCED. DIRECTED TO ITEM OF PLAN NOTE REFERENCED. CIRCLE WITH NUMBER INDICATES A PLAN NOTE REFERENCED WITH THE NUMBER INDICATING THE ITEM NUMBER OF THE PLAN NOTE REFERENCED. C. F. E. D. ELEVATION INDICATOR REVISION TRIANGLE REVISION CLOUD SECTION/ELEVATION LETTER SHEET NUMBER NUMBER WHERE SECTION/ELEVATION IS SHOWN CONNECT NEW TO EXISTING 1 B. A. SHEET NUMBER WHERE DETAIL/SCHEMATIC/ENLARGED DETAIL/SCHEMATIC/ENLARGED PLAN NUMBER NORTH ARROW DIRECTION SHEET NUMBER WHERE RISER/STACK IS SHOWN RISER/STACK NUMBER 1 PLAN NOTE: GENERAL NOTE: UP DOWN RISE DROP AUTOMATIC BALANCING VALVE MANUAL BALANCING VALVE GAS VALVE PRESSURE REDUCING VALVE TWO-WAY TEMPERATURE CONTROL VALVE SOLENOID VALVE GLOBE VALVE GATE VALVE BALL VALVE SWING CHECK VALVE (FLOW TO RIGHT) BUTTERFLY VALVE NON SLAM CHECK VALVE (FLOW TO RIGHT) GATE VALVE IN ROAD BOX DIFFERENTIAL PRESSURE TRANSMITTER PIPE DEMOLISH TO POINT ON DEMOLITION PLAN PIPE CONNECT TO EXISTING ON NEW PLAN SIGHT GLASS (REFRIGERANT) METER (WATER/GAS) AIR OR REFRIGERANT FILTER DRYER BACKFLOW PREVENTER ASSEMBLY PIPE CAP ON DEMOLITION PLAN AQUASTAT PRESSURE SENSOR FLOW SWITCH STEAM TRAP (FLOAT/THERMOSTATIC) STEAM TRAP (BUCKET) STEAM TRAP (THERMODYNAMIC) STRAINER WITH BLOW DOWN VALVE TEMPERATURE SENSOR TEMPERATURE SWITCH PRESSURE SWITCH STRAINER FLOW METER EXPANSION LOOP (LxW) FLEXIBLE PIPE CONNECTOR ALIGNMENT GUIDE PRESSURE/TEMPERATURE PLUG SITE PRESSURE TAP (PORTABLE GAUGE) THERMO WELL (PORTABLE GAUGE) IN LINE PUMP THERMOMETER AUTOMATIC AIR VENT MANUAL AIR VENT STEAM PRESSURE GAUGE WITH VALVE AND PIGTAIL PRESSURE GAUGE WITH VALVE ECCENTRIC REDUCER OR INCREASER CONCENTRIC REDUCER OR INCREASER PIPE UP THROUGH FLOOR TEE CONNECTION OFF TOP OF PIPE TEE CONNECTION OFF BOTTOM OF PIPE TEE CONNECTION OFF SIDE OF PIPE DIRECTION OF FLOW PITCH DOWN IN DIRECTION OF ARROW ANCHOR POINT PIPE RISE IN DIRECTION OF FLOW UNION PIPE CAP THREE-WAY TEMPERATURE CONTROL VACUUM BREAKER VALVE RELIEF VALVE VALVE (MIXING) PIPE DROP IN DIRECTION OF FLOW PIPE DOWN THROUGH FLOOR OR DROP/RISE TO EQUIPMENT ABV MBV GV PRV GBV GV BV BFV GV PLAN IS SHOWN NSB M . T I M O T H Y V M OORE PRO FES SIO NAL E N GIN E E R No. 13815A N A I D N I D E RE T S I G E R STATE OF COMMISSION NUMBER DATE SHEET NUMBER SHEET TITLE CERTIFICATION The concepts, ideas, designs, plans, and details as shown on this document are the sole property of MSKTD & Associates, Inc., and were created, developed and presented for use on this specific project. None of the concepts, ideas, designs, plans, and details shall be used by any person, firm, or corporation for any purpose whatsoever, without the expressed written consent of MSKTD & Associates, Inc. The Owner shall be permitted to retain copies for information and reference in connection with this project. 1715 MAGNAVOX WAY FORT WAYNE, IN 46804 voice 260.432.9337 fax 260.436.2402 930 NORTH MERIDIAN INDIANAPOLIS, IN 46204 voice 317.917.1190 fax 317.822.6236 http://www.msktd.com ARCHITECTURE ENGINEERING INTERIOR DESIGN 06/24/2011 6/24/2011 2:31:46 PM 11700 North Meridian Street, Carmel, IN 46032 M001 11023 06-30-11 LDR Reception and C340 Renovation SYMBOLS AND ABBREVIATIONS IU Health North Hospital Revisions: Date: By: RS 5 6 F F.8 G G.3 HJ 4.9 7 30x18 16x14 30x18 24x24 36x24 14x6 10"10x14 14x6 10"10"10"10"14x6 6"10"14x6 16x14 12"62x28 8"8"8"10"12"8x14 1 1/2" HWS 2 1/2" HWR 3/4" HWS 3/4" HWR 3/4" HWR 3/4" HWS 1 1/2" HWS 2 1/2" HWR 3/4" HWR 3/4" HWS 3/4" HWS 3/4" HWR 3/4" HWS 3/4" HWR 1 1/2" HWS 2 1/2" HWR 3/4" HWS 3/4" HWR 1 1/4" HWS 2 1/2" HWR 3/4" HWS 3/4" HWR 3/4" HWS 2 1/2" HWR 3/4" HWS 2 1/2" HWR 3/4" HWS 3/4" HWR 1" HWS 1" HWR 3/4" HWS 3/4" HWR 10"12"6"8"8"12"12"8"6"14x6 24x14 16x15 10x10 12"12x10 10x10 14x6 X-190 X-190 X-250 X-325 X-95 X-100 X-190 X-300 X-300 X-225 1 TYPICAL 1 TYPICAL TB X-125 TB TB 2 TYPICAL 1 TYPICAL 2 TYPICAL 3 LDR C307 Corridor C3C08 Nourish Ctr C341Clean Util C342 . T I M O T H Y V M OORE PRO FES SIO NAL E N GIN E E R No. 13815A N A I D N I D E RE T S I G E R STATE OF COMMISSION NUMBER DATE SHEET NUMBER SHEET TITLE CERTIFICATION The concepts, ideas, designs, plans, and details as shown on this document are the sole property of MSKTD & Associates, Inc., and were created, developed and presented presented for use on this specific project. None of the concepts, ideas, designs, plans, and details shall be used by any person, firm, or corporation for any purpose whatsoever, without the expressed written consent of MSKTD & Associates, Inc. The Owner shall be permitted to retain copies for information and reference in connection with this project. 1715 MAGNAVOX WAY FORT WAYNE, IN 46804 voice 260.432.9337 fax 260.436.2402 930 NORTH MERIDIAN INDIANAPOLIS, IN 46204 voice 317.917.1190 fax 317.822.6236 http://www.msktd.com ARCHITECTURE ENGINEERING INTERIOR DESIGN 06/24/2011 6/24/2011 2:31:48 PM 11700 North Meridian Street, Carmel, IN 46032 M203 11023 06-30-11 LDR Reception and C340 Renovation THIRD FLOOR DEMOLITION PLANIU Health North Hospital NORTH SCALE: 1/8" = 1'-0" THIRD FLOOR DEMOLITION PLAN GENERAL NOTES: A. ALL EQUIPMENT AND DUCTWORK SHOWN WITH THIN/LIGHT SOLID LINES IS EXISTING TO REMAIN. B. ALL EQUIPMENT AND DUCTWORK SHOWN WITH THICK/DARK DASHED LINES IS EXISTING TO BE REMOVED OR RELOCATED. C. RELEVANT EQUIPMENT AND DUCTWORK SHOWN IS BASED ON EXISTING DRAWINGS AND FIELD SURVEY. NOT ALL EXISTING EQUIPMENT AND DUCTWORK IS SHOWN. CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS AFFECTED BY THIS RENOVATION AND NOTIFY THE ENGINEER IF CONDITIONS ARE NOT AS INDICATED. D. OWNER SHALL HAVE FIRST RIGHT OF REFUSAL UPON REMOVAL OF ALL SALVAGED ITEMS. OTHERWISE, REMOVE ALL DEMOLISHED ITEMS FROM THE SITE. E. AFTER DUCTWORK REMOVAL, PATCH HOLES THROUGH WALLS AND FLOORS TO MATCH SURRONDING CONDITIONS. F. REMOVE AND RE-INSTALL LAY-IN CEILING AS REQUIRED TO COMPLETE WORK. REPLACE DAMAGED CEILING MATERIALS TO MATCH EXISTING CEILING. G. REMOVE EXISTING DRYWALL/MASONRY WALLS AS REQUIRED TO COMPLETE WORK. PATCH AND PAINT WALLS TO MATCH EXISTING CONDITIONS. PLAN NOTES: 1 PRIOR TO ANY DEMOLITION WORK, THE CONTRACTOR SHALL MEASURE AND RECORD THE AIRFLOW OF ALL THE EXISTING DIFFUSERS AND GRILLES, WITH THE TERMINAL BOX IN ITS FULL OPEN POSITION. SUBMIT REPORT TO THE ENGINEER. Revisions: Date: By: 2 REMOVE DIFFUSER/GRILLE AND ASSOCIATED DUCTWORK AS SHOWN. 3 REMOVE ROOM SENSOR AND ASSOCIATED WIRING. SAVE FOR RELOCATION. RS RS 5 6 F F.8 G G.3 HJ 4.9 7 Office Cxxx Registration Cxxxa Corridor C3C08 LDR C307 Nourish Ctr C341 Office C340A Bereavement C340B Clean Util C342 28x14 22x14 62x28 40x20 30x18 30x18 24x24 30x18 36x24 16x14 2 1/2" HWR 3/4" HWS 2 1/2" HWR 3/4" HWS 1 1/4" HWS 2 1/2" HWR 1 1/4" HWS 2 1/2" HWR 1 1/2" HWS 2 1/2" HWR 3/4" HWS 3/4" HWR 3/4" HWS 3/4" HWR 3/4" HWS 3/4" HWR 3/4" HWS 3/4" HWR 3/4" HWR 3/4" HWS 3/4" HWR 3/4" HWS 1 1/2" HWS 2 1/2" HWR 10"ø 8"ø 10"8x8 8"øA8-175 8"ø R10-175 24x14 6"ø 10"10x10 A6-75 X-250 X-300 TB-32072A A6-100 B8-200 8"ø 8"14"12"6"8"R10-200 R10-200 8"6"ø 8x10 X-225 X-95 X-100 X-190 1 TYPICAL 2 210x14 10"10"14x6 12x10 14x610"8"12"8"12"14x6 14x610"10"6"12"16x14 14x6 8"12"10"10"14x6 10"6"8"8"8"10"X-125 3 TB 4 TB 5 TB 6 . T I M O T H Y V M OORE PRO FES SIO NAL E N GIN E E R No. 13815A N A I D N I D E RE T S I G E R STATE OF COMMISSION NUMBER DATE SHEET NUMBER SHEET TITLE CERTIFICATION The concepts, ideas, designs, plans, and details as shown on this document are the sole property of MSKTD & Associates, Inc., and were created, developed and presented for use on this specific project. None of the concepts, ideas, designs, plans, and details shall be used by any person, firm, or corporation for any purpose whatsoever, without the expressed written consent of MSKTD & Associates, Inc. The Owner shall be permitted to retain copies for information and reference in connection with this project. 1715 MAGNAVOX WAY FORT WAYNE, IN 46804 voice 260.432.9337 fax 260.436.2402 930 NORTH MERIDIAN INDIANAPOLIS, IN 46204 voice 317.917.1190 fax 317.822.6236 http://www.msktd.com ARCHITECTURE ENGINEERING INTERIOR DESIGN 06/24/2011 6/24/2011 2:31:50 PM 11700 North Meridian Street, Carmel, IN 46032 M303 11023 06-30-11 LDR Reception and C340 Renovation THIRD FLOOR MECHANICAL PLAN IU Health North Hospital NORTH SCALE: 1/8" = 1'-0" THIRD FLOOR MECHANICAL PLAN GENERAL NOTES: A. ALL EQUIPMENT AND DUCTWORK SHOWN WITH THIN/LIGHT SOLID LINES IS EXISTING TO REMAIN. B. ALL EQUIPMENT, DUCTWORK AND PIPING SHOWN WITH THICK/DARK SOLID LINES IS NEW OR RELOCATED. C. RELEVANT EQUIPMENT AND DUCTWORK SHOWN IS BASED ON EXISTING DRAWINGS AND FIELD SURVEY. NOT ALL EXISTING EQUIPMENT AND DUCTWORK IS SHOWN. CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS AFFECTED BY THIS RENOVATION AND NOTIFY THE ENGINEER IF CONDITIONS ARE NOT AS INDICATED. D. BRANCH DUCTWORK RUNOUTS TO DIFFUSERS AND TERMINAL BOXES SHALL MATCH THE INLET SIZES OF THE DIFFUSERS AND TERMINAL BOXES, UNLESS OTHERWISE NOTED. E. REMOVE AND RE-INSTALL LAY-IN CEILING AS REQUIRED TO COMPLETE WORK. REPLACE DAMAGED CEILING MATERIALS TO MATCH EXISTING CEILING. F. REMOVE EXISTING DRYWALL/MASONRY WALLS AS REQUIRED TO COMPLETE WORK. PATCH AND PAINT WALLS TO MATCH EXISTING CONDITIONS. PLAN NOTES: 1 EXISTING DIFFUSERS AND GRILLES SHALL BE REBALANCED TO PRE-CONSTRUCTION AIRFLOW WITH TERMINAL BOX IN MAX OPEN POSITION, AS RECORDED IN PRE-CONSTRUCTION AIRFLOW MEASUREMENT. G. REFER TO ARCHITECT'S REFLECTED CEILING PLAN FOR FINAL LOCATIONS OF AIR OUTLETS AND INLETS. ADJUST BRANCH DUCTWORK AS REQUIRED. 2 2 RE-BALANCE EXISTING DIFFUSER TO AIRFLOW SPECIFIED WITH TERMINAL BOX IN MAX OPEN POSITION. 3 RELOCATED EXISTING THERMOSTAT. Revisions: Date: By: 4 RE-BALANCE EXISTING TERMINAL BOX TO A MAXIMUM SETTING OF 175 CFM AND A MINIMUM SETTING OF 100 CFM. 5 RE-BALANCE EXISTING TERMINAL BOX TO A MAXIMUM SETTING OF 575 CFM AND A MINIMUM SETTING OF 230 CFM. 6 RE-BALANCE EXISTING CONSTANT VOLUME TERMINAL BOX TO THE CONNECTED AIRFLOW. WATER COIL BALL VALVE (TYPICAL). STRAINER. MANUAL AIR VENT TWO-WAY TEMPERATURE AUTOMATIC FLOW CONTROL VALVE. (TYPICAL). AT HIGH POINT. CONTROL VALVE. ECCENTRIC REDUCER (TYPICAL). CONNECT WATER SUPPLY PIPING TO LEAVING AIR SIDE OF COIL. PROVIDE UNIONS AND/OR FLANGES FOR REMOVAL OR SERVICE OF COMPONENTS. GENERALLY, TEMPERATURE CONTROL VALVE IS IN THE SUPPLY PIPING FOR CHILLED WATER AND IN THE RETURN PIPING FOR HOT WATER. THIS PIPING DIAGRAM IS TYPICAL FOR ALL TWO-WAY WATER COILS EXCEPT AHU WATER COILS. 3. 2. 1. NOTES: AND CAP AT LOW POINT. HOSE END DRAIN VALVE 4. UNION SUPPLY RETURN . T I M O T H Y V M OORE PRO FES SIO NAL E N GIN E E R No. 13815A N A I D N I D E RE T S I G E R STATE OF COMMISSION NUMBER DATE SHEET NUMBER SHEET TITLE CERTIFICATION The concepts, ideas, designs, plans, and details as shown on this document are the sole property of MSKTD & Associates, Inc., and were created, developed and presented for use on this specific project. None of the concepts, ideas, designs, plans, and details shall be used by any person, firm, or corporation for any purpose whatsoever, without the expressed written consent of MSKTD & Associates, Inc. The Owner shall be permitted to retain copies for information and reference in connection with this project. 1715 MAGNAVOX WAY FORT WAYNE, IN 46804 voice 260.432.9337 fax 260.436.2402 930 NORTH MERIDIAN INDIANAPOLIS, IN 46204 voice 317.917.1190 fax 317.822.6236 http://www.msktd.com ARCHITECTURE ENGINEERING INTERIOR DESIGN 06/24/2011 6/24/2011 2:31:50 PM 11700 North Meridian Street, Carmel, IN 46032 M900 11023 06-30-11 LDR Reception and C340 Renovation SCHEDULES AND DETAILS IU Health North Hospital GRILLE AND DIFFUSER SCHEDULE MARK SERVICE MANUFACTURER MODEL OVERALL SIZE NECK SIZE MAX CFM MAX NC REMARKS A6 SUPPLY TITUS PCS 24"x24" 6"125 25 1 A8 SUPPLY TITUS PCS 24"x24" 8"215 25 1 B8 SUPPLY TITUS PCS 24"x24" 8"215 25 2 R10 SUPPLY TITUS PAR 24"x12" 22"x10" 1250 25 3 X EXISTING 4 REMARKS: 1. FURNISH WITH FULL PERFORATED FACE WITH 3/16" HOLES ON 1/4" CENTERS. FURNISH WITH FULL FOUR-WAY DEFLECTORS. 2. FURNISH WITH FULL PERFORATED FACE WITH 3/16" HOLES ON 1/4" CENTERS. FURNISH WITH THREE-WAY DEFLECTORS. 3. FURNISH WITH FULL PERFORATED FACE WITH 3/16" HOLES ON 1/4" CENTERS. 4. EXISTING DIFFUSER/GRILLE TO BE RE-BALANCED AS INDICATED. TERMINAL BOX SCHEDULE MARK MANUFACTURER MODEL MAX CFM MIN CFM INLET SIZE OUTLET SIZE HEATING COIL DESIGN MBH EAT LAT EWT GPM ROWS REMARKS TB-32072A TRANE VCWF 300 100 8" 12"x10" 4.9 55 °F 100 °F 180 °F 0.5 2 1, 2, 3 REMARKS: 1. HEATING WATER COIL SHALL MEET OR EXCEED SCHEDULED GPM. 2. CONTRACTOR SHALL VERIFY LEFT OR RIGHT HAND COIL PIPING CONNECTIONS. NO SCALE 1 TWO-WAY VALVE WATER COIL PIPING DIAGRAM Revisions: Date: By: 3. PROVIDE WITH THERMAL INSULATION AND DOUBLE WALL METAL LINER. NO THERMAL INSULATION IS TO BE EXPOSED TO THE AIRSTREAM. 5 6 F F.8 G G.3 HJ 4.9 7 Office Cxxx Registration Cxxxa LDR C307 Corridor C3C08 Clean Util C342 Nourish Ctr C341 Office C340A Bereavement C340B 1 1 . T I M O T H Y V M OORE PRO FES SIO NAL E N GIN E E R No. 13815A N A I D N I D E RE T S I G E R STATE OF COMMISSION NUMBER DATE SHEET NUMBER SHEET TITLE CERTIFICATION The concepts, ideas, designs, plans, and details as shown on this document are the sole property of MSKTD & Associates, Inc., and were created, developed and presented for use on this specific project. None of the concepts, ideas, designs, plans, and details shall be used by any person, firm, or corporation for any purpose whatsoever, without the expressed written consent of MSKTD & Associates, Inc. The Owner shall be permitted to retain copies for information and reference in connection with this project. 1715 MAGNAVOX WAY FORT WAYNE, IN 46804 voice 260.432.9337 fax 260.436.2402 930 NORTH MERIDIAN INDIANAPOLIS, IN 46204 voice 317.917.1190 fax 317.822.6236 http://www.msktd.com ARCHITECTURE ENGINEERING INTERIOR DESIGN 06/24/2011 6/24/2011 2:31:44 PM 11700 North Meridian Street, Carmel, IN 46032 FP303 11023 06-30-11 LDR Reception and C340 Renovation THIRD FLOOR FIRE PROTECTION PLAN IU Health North Hospital NORTH SCALE: 1/8" = 1'-0" THIRD FLOOR FIRE PROTECTION PLAN GENERAL NOTES: A. AFTER PIPING REMOVAL, PATCH HOLES THROUGH WALLS AND FLOORS TO MATCH SURROUNDING CONDITIONS. B. REMOVE AND RE-INSTALL EXISTING LAY-IN CEILING AS REQUIRED TO COMPLETE WORK. REPLACE DAMAGED CEILING MATERIALS TO MATCH EXISTING CONDITIONS. C. REMOVE EXISTING DRYWALL CEILINGS AS REQUIRED TO COMPLETE WORK. PATCH AND PAINT CEILINGS TO MATCH EXISTING CONDITIONS. D. REMOVE EXISTING DRYWALL/MASONRY WALLS AS REQUIRED TO COMPLETE WORK. PATCH AND PAINT WALLS TO MATCH EXISTING CONDITIONS. E. THE FIRE PROTECTION CONTRACTOR IS RESPONSIBLE FOR THE DESIGN, COORDINATION, AND INSTALLATION OF THE FIRE PROTECTION SYSTEM, INCLUDING REMOVING AND INSTALLING NEW PIPING AS REQUIRED FOR A COORDINATED INSTALLATION. THE FIRE PROTECTION SYSTEM IS TO BE DESIGNED AND INSTALLED IN COMPLIANCE WITH NFPA AND ALL OTHER STATE AND LOCAL CODES. PLAN NOTES: 1. WITHIN THIS OUTLINED AREA, THE FIRE PROTECTION CONTRACTOR SHALL REMOVE SPRINKLER MAINS, BRANCH PIPING, AND HEADS, AND SHALL REWORK/INSTALL NEW SPRINKLER MAINS/BRANCH PIPING, AND NEW HEADS AS REQUIRED TO COORDINATE WITH NEW CEILING LAYOUT AND OCCUPANCY REQUIREMENTS. CONTRACTOR SHALL PERFORM HYDRAULIC CALCULATIONS AND PROVIDE THE PROPER NUMBER OF SPRINKLER HEADS AND SPACING TO BE DESIGNED AND INSTALLED IN COMPLIANCE WITH NFPA AND ALL OTHER STATE AND LOCAL CODES. THE CONTRACTOR SHALL COORDINATE SYSTEM SHUT-DOWNS AND TEMPORARY SERVICES WITH THE OWNER. Revisions: Date: By: SS RECEPTACLES: INDICATED WITHOUT WIRE MARKS. PROVIDE A MINIMUM OF 2 CONDUCTORS AND GROUND WHERE CONDUIT IS MOUNTING: SWITCHES: GENERAL NOTES: CEILING MOUNT WALL MOUNT NORTH ELECTRICAL ABBREVIATIONS DRAWINGS SYMBOLS DRAWING SYMBOLS: NOTE DESIGNATIONS: GENERAL FIRE ALARM SYMBOLS PANELBOARDS POWER AND WIRING SYMBOLS ELECTRICAL NOTES LIGHTING CONTROL SYMBOLS COMMUNICATIONS/SIGNAL SYMBOLS LIGHTING SYMBOLS NURSE CALL SYMBOLS TVC OCP MC MCC MCP MH MIC MLO MTD MTS NA NC NCTC NEC NF NIC NL NO NTS OL PPC PF PH PT PRI PVC RCC RCS REF SEP SMD SN SP SPKR ST SW SWBD SQ TC TCC TD TR TDCD TDCE TDOD TDOE TEL TTB TTC TVSS TYP UC UNO VA VFD WWM WP XMCC G GROUND KCMIL KW MAT KVAR HP ITC KVA JB IG INSUL HZ HH GFP GRC GEC GFI GC KILO-VOLT AMPERE REACTIVE KILOWATT MATERIAL GENERAL CONTRACTOR GROUNDING ELECTRODE CONDUCTOR GROUND FAULT INTERRUPTER GROUND FAULT PROTECTOR GALVANIZED RIGID STEEL CONDUIT INTERCOM TERMINAL CABINET THOUSAND CIRCULAR MILS HORSEPOWER ISOLATED GROUND INSULATION JUNCTION BOX KILO-VOLT AMPERE HERTZ (FREQUENCY) HANDHOLE EH FDS FLR FVNR FI FDR FACP FARA EMT EWC FENG EMS EM CU ECB EBH EC DP DT DISC CPT CT CP CKT CLG CB CCTV ELECTRIC HEATER ENERGY MANAGEMENT SYSTEM ELECTRICAL METALLIC TUBING ELECTRIC WATER COOLER FIRE ALARM CONTROL PANEL FIRE ALARM REMOTE ANNUNCIATOR FUSED DISCONNECT SWITCH FULL VOLTAGE NON REVERSING FILM ILLUMINATOR FLOOR FEEDER EMERGENCY ENGINEER FUSED ENCLOSED CIRCUIT BREAKER CLOSED CIRCUIT TELEVISION CONTROL POWER TRANSFORMER CURRENT TRANSFORMER ELECTRIC BASEBOARD HEATER ELECTRICAL CONTRACTOR COPPER DISCONNECT DOUBLE POLE DOUBLE THROW CIRCUIT BREAKER CONTROL PANEL CIRCUIT CEILING BFG BPS CBMS ATS ATSB ARCH AFF AIC ALT AFG AC AF A AMPERE RATING OF FUSE ABOVE FINISHED FLOOR ABOVE FINISHED GRADE AMPS INTERRUPTING CAPACITY ARCHITECT/ARCHITECTURAL AUTOMATIC TRANSFER SWITCH AUTOMATIC TRANSFER SWITCH WITH BYPASS BELOW FINISHED GRADE BUILDING MANAGEMENT SYSTEM BOLTED PRESSURE SWITCH CONDUIT ABOVE COUNTER ALTERNATE AMPERE TD CLOSE ON DE-ENERGIZATION WIREMOLD (SURFACE MTD) PHASE OR DIAMETER WEATHERPROOF EMERGENCY MOTOR CONTROL CENTER TELEVISION CABINET TD CLOSE ON ENERGIZATION TD OPEN ON DE-ENERGIZATION TD OPEN ON ENERGIZATION TELEPHONE TERMINAL BOARD TELEPHONE TERMINAL CABINET TRANSIENT VOLT. SURGE SUPPRESSION UNLESS NOTED OTHERWISE VARIABLE FREQUENCY DRIVE TYPICAL UTILITY COMPANY VOLT-AMPERE WIRE OR WATTS TELEPHONE REFER, REFERENCE TEMPERATURE CONTROL CABINET OR SWITCHBOARD SQUARE TIME CLOCK CONTRACTOR TIME DELAY TIMING RELAY SEPARATE SMOKE DAMPER SOLID NEUTRAL SINGLE POLE LOUDSPEAKER SINGLE THROW SWITCH OVERCURRENT PROTECTION OVERLOAD RELAY/OVERLOAD CONTACT PLUMBING CONTRACTOR POTENTIAL TRANSFORMER POLYVINYL CHLORIDE RELAY CONTROL CABINET RELAY CONTROL STATION POWER FACTOR PHASE PRIMARY NIGHT LIGHT NORMALLY OPEN OR NUMBER NOT TO SCALE POLE MECHANICAL CONTRACTOR MOTOR CONTROL CENTER MOTOR CIRCUIT PROTECTOR MANUAL TRANSFER SWITCH NORMALLY CLOSED NURSE CALL TERMINAL CABINET NATIONAL ELECTRIC CODE NOT APPLICABLE NON-FUSED NOT IN CONTRACT MANHOLE MICROPHONE MAIN LUG ONLY MOUNTED BRKR BREAKER MSB MAIN SWITCHBOARD XP EXPLOSIONPROOF XLP1 EMERGENCY PANEL REVISION TRIANGLE REVISION OR ADDENDUM CLOUD NORTH ARROW DIRECTION 1 PLAN NOTE: GENERAL NOTE: ALL OF THE SYMBOLS SHOWN ON THIS DRAWING ARE NOT NECESSARILY USED ON THE VARIOUS PLANS. ALL MOUNTING HEIGHTS ARE TO THE BOTTOM OF DEVICES OR BOXES UNLESS NOTED OTHERWISE. CONTRACTOR TO ADJUST HEIGHT TO STANDARD COURSING IN BLOCK WALL CONSTRUCTION. WHERE SPECIFIC MOUNTING HEIGHTS ARE NOTED ON THE VARIOUS DRAWINGS, THEY SHALL SUPERSEDE HEIGHTS INDICATED ON THIS SHEET. CIRCUIT NUMBERS: ALL DEVICES, WIRING, LIGHT FIXTURES, ELECTRICAL CONNECTIONS, ETC. DRAWN ON THE LIGHTING SYSTEMS, DETAIL SHEETS AND ALL OTHER SHEETS EXCEPT FOR DEMOLITION PLANS ARE NEW AND SHALL BE PROVIDED AND INSTALLED BY THE ELECTRICAL CONTRACTOR UNLESS NOTED OTHERWISE. THE ELECTRICAL CONTRACTOR SHALL REVIEW SHOP DRAWINGS FOR ALL ELECTRICAL CONNECTIONS TO EQUIPMENT FURNISHED BY THE OWNER, GENERAL CONTRACTOR, MECHANICAL CONTRACTOR, OR PLUMBING CONTRACTOR. THE ELECTRICAL CONTRACTOR SHALL COORDINATE EXACT EQUIPMENT CONNECTIONS AND INSTALL COMPONENTS AS INDICATED ON THEIR RESPECTIVE SHOP DRAWINGS. DEVICES WITH A LOWER CASE SUBSCRIPT INDICATES THE GROUP THE DEVICE IS CONNECTED TO. (EXAMPLE: A SWITCH OR VOLUME CONTROL WITH AN "a" SUBSCRIPT WILL CONTROL A LIGHTING FIXTURE, OUTLET OR SPEAKER WITH AN "a" SUBSCRIPT RESPECTIVELY). CIRCUITS THAT REQUIRE A NEUTRAL CONDUCTOR SHALL HAVE A SEPARATE NEUTRAL FOR EACH OVERCURRENT DEVICE PROVIDING POWER TO THE CIRCUIT. A. B. C. D. E. F. ALL CIRCUIT NUMBERS SHOWN ON THE PLANS OR RISERS ARE TO BE CONNECTED TO BREAKERS POSITIONS INDICATED. CIRCUIT NUMBERS ARE NOT TO BE CHANGED UNLESS VERIFIED WITH THE ENGINEER. ALL BRANCH CIRCUITS ARE TO BE CONNECTED TO 20 AMP-1P BREAKERS UNLESS NOTED OTHERWISE. CONTRACTOR WILL BE RESPONSIBLE FOR PROPER SIZING OF ALL CONDUITS SERVING MULTI-WIRE CIRCUITS. CONTRACTOR WILL BE RESPONSIBLE FOR PROPER DERATING OF CONDUCTOR AMPACITIES PER NEC TABLE 310-15(B)(2)(a) FOR MULTIPLE CONDUCTOR/CONDUIT INSTALLATION. NO BRANCH CIRCUIT CONDUIT SYSTEM SHALL CONTAIN IN EXCESS OF 9 CONDUCTORS UNLESS NOTED OTHERWISE OR APPROVED BY ENGINEER. 1. 2. 3. 4. GENERAL INFORMATION AS INDICATED ON A SHEET. SPECIFIC INFORMATION AS INDICATED ON A SHEET. LEADER LINE OF PLAN NOTE REFERENCED DIRECTED TO ITEM OF PLAN NOTE REFERENCED. CIRCLE WITH NUMBER INDICATES THE PLAN F DD F SD F V F MANUAL PULL STATION, WALL MOUNT AT SWITCH HEIGHT. AUDIBLE/VISIBLE ALARM DEVICE, CEILING MOUNT (WP = PHOTOELECTRIC SMOKE DETECTOR, CEILING MOUNT VISIBLE ALARM DEVICE, WALL MOUNT (WP = WEATHERPROOF UNIT) DUCT MOUNT SMOKE DETECTOR WEATHERPROOF UNIT) LIGHTING PANELBOARDS (SURFACE-RECESSED) AHP1 RECEPTACLE OR SMALL POWER PANELBOARDS PANELBOARD DESIGNATION DISTRIBUTION PANELBOARD OR POWER PANEL MAIN SWITCHGEAR LENGTHS AS INDICATED, 10" ABOVE COUNTER. PREFABRICATED MULTI-OUTLET ASEMBLY, DOUBLE DUPLEX RECEPTACLE, GFCI, MOUNT 10" ABOVE COUNTER TOP TV POWER AND CABLE OUTLET. SEE DETAIL. SPECIAL RECEPTACLE OR OUTLET AS REQUIRED, SEE SHOP DRAWINGS FLUSH FLOOR BOX -PROVIDE DEVICES AS INDICATED ON DRAWINGS. SPLIT WIRED RECEPTACLE DUPLEX RECEPTACLE MOUNT 10" ABOVE COUNTER TOP DUPLEX CONVENIENCE RECEPTACLE SINGLE CONVENIENCE RECEPTACLE DUPLEX RECEPTACLE, GFCI, MOUNT 10" ABOVE COUNTER TOP DUPLEX CONVENIENCE RECEPTACLE, GFCI TELE/POWER POLE -PROVIDE DEVICES AS INDICATED ON DRAWINGS. DOUBLE DUPLEX RECEPTACLE, GFCI 120 VAC, WALL MOUNT 16" AFF UNLESS NOTED OTHERWISE D = DEDICATED 1P-20A CIRCUIT EWC = ELECTRIC WATER COOLER -CONCEAL BEHIND OR BELOW COOLER -VERIFY EXACT REQUIREMENTS WITH PC. IG = ISOLATED GROUND WP = WEATHER-RESISTANT RECEPTACLE WITH WET-LOCATION COVER DOUBLE DUPLEX RECEPTACLE DOUBLE DUPLEX RECEPTACLE MOUNT 10" ABOVE COUNTER TOP FLOOR PEDESTAL BOX -PROVIDE DEVICES AS INDICATED ON DRAWINGS. P of DEVICE FOR CORRECT TERMINATION. JUNCTION BOX (FLUSH WALL) VARIABLE FREQUENCY DRIVE WITH DISCONNECT SWITCH MANUAL MOTOR STARTER, SWITCH HEIGHT. TRANSFORMER -SEE TRANSFORMER SCHEDULE ENCLOSED CIRCUIT BREAKER, MOUNT FLUSH IN WALL 6'-0" AFF CONTROL PANEL MOTOR DISCONNECT SWITCH, SEE EQUIPMENT SCHEDULE SWITCH. MOUNT 6'-0" AFF TO TOP. COMBINATION MAGNETIC STARTER AND FUSED OR CB DISCONNECT MAGNETIC STARTER. MOUNT 6'-0" AFF TO TOP. FLUSH MTD. UNO T CB CP CONDUCTOR AS REQUIRED. BRANCH CIRCUIT WIRING TO PANEL 'LP1', CIRCUIT BREAKER #1. 3 POLE -30 AMP SIZE OCP DEVICE CONDUCTORS = 3#10, #10G IN 3/4" CONDUIT INDICATED). DOT INDICATES GROUND WIRE. CIRCUITS AS INDICATED OR AS REQUIRED. PROVIDE GROUNDING SIZE CONDUIT. PROVIDE CONDUCTORS ON MULTI-PHASE BRANCH CAPPED CONDUIT PROVIDE 2 MINIMUM SIZE CONDUCTORS AND GROUND, IN MINIMUM BRANCH CIRCUIT WIRING TO PANEL 'LP1', CIRCUIT BREAKER #1. FLEXIBLE CONDUIT BASIC SURFACE RACEWAY OR PATHWAY CONDUIT CONCEALED BELOW SLAB OR BELOW GRADE CONDUIT CONCEALED IN WALL OR ABOVE CEILING JUNCTION BOX (CEILING -WALL MOUNT) WIRE MARKS INDICATE THE NUMBER OF CONDUCTORS, UNLESS NOTED OTHERWISE, ETC. (4 CONDUCTORS WITH GROUND 3#10, #10G, 3/4"C. 3P-30A LP1-1 LP1-1 WMJ J CONDUIT EXPOSED ON WALL OR CEILING HEAVY DUTY RECEPTACLE (NEMA CONFIGURATION INDICATED) HORIZONTAL MOUNTED DUPLEX RECEPTACLE 50A-2P RANGE OR WELDING OUTLET (NEMA CONFIGURATION INDICATED) J SLEEVE THROUGH WALL SURFACE RACEWAY OR PATHWAY WITH DEVICES AS INDICATED. MFGR MANUFACTURER TR = TAMPER RESISTANT (SURFACE-RECESSED) F AV F AV AUDIBLE/VISIBLE ALARM DEVICE, WALL MOUNT (WP = WEATHERPROOF UNIT) WALL MOUNTED PANELBOARDS SHALL BE INSTALLED WITH THE TOP OF TRIM AT 6'-6" AFF, PANELBOARDS EXCEEDING 72" IN HEIGHT SHALL BE MOUNTED WITH THE HIGHEST BREAKER/SWITCH HANDLE AT 78" AFF. G. 5 CENTER LINE FHP FRACTIONAL HORSEPOWER V VOLTAGE PNL PANEL MOCD MAXIMUM OVERCURRENT DEVICE FTC FOOTCANDLE DL = WEATHER-RESISTANT RECEPTACLE WITH DAMP-LOCATION COVER M = MOMENTARY CONTACT SINGLE POLE TOGGLE SWITCH, 46" AFF (48" AFF IN BLOCK WALLS), DIMMER SWITCH, 46" AFF (48" AFF IN BLOCK WALLS), P = PILOT LIGHT K = KEYED SWITCH TYPE a SWITCH GROUP 2 4 = 4-WAY 3 = 3-WAY 2 = DOUBLE POLE UNLESS NOTED OTHERWISE. UNLESS NOTED OTHERWISE. D = DIGITAL TIMER SWITCH F A AUDIBLE ALARM DEVICE, CEILING MOUNT (WP = WEATHERPROOF UNIT) INSTALL ALL OUTLETS 16" AFF, UNLESS NOTED OTHERWISE DUAL JACK FIBER OPTIC CABLE OUTLET, UNO. WORKSTATION OUTLET, 3 JACKS UNLESS OTHER QUANTITY ANALOG TELEPHONE OUTLET P = PAY PHONE, WALL MOUNT AT SWITCH HEIGHT, OR AS NOTED W = WALL MOUNT AT SWITCH HEIGHT. AC = INSTALL 10" ABOVE COUNTER OR BOTTOM OF NEXT BLOCK D = DEDICATED LINE SEE SPECIFICATIONS. TERMINATE CONDUITS ABOVE ACCESSIBLE CEILINGS ROUGH-IN BOX TO ABOVE ACCESSIBLE CEILING, UNLESS NOTED OTHERWISE, ALL DEVICES SHALL INCLUDE A 1" CONDUIT ROUTED FROM OUTLET COURSING. TV OUTLET, CEILING MOUNTED TV OUTLET, WALL MOUNTED, HEIGHT AS INDICATED ON DRAWINGS WITH INSULATED BUSHING. WAP WIRELESS ACCESS POINT, SINGLE WORKSTATION JACK, MOUNTING AS NOTED. INDICATED. DOWNLIGHT FIXTURE LINEAR FIXTURE STRIP FIXTURE EXIT SIGN WITH DIRECTION ARROWS OR FACES AS EMERGENCY BATTERY LIGHT INDICATED SCONCE FIXTURE N M N PE N SE N SS N E NURSE CALL MASTER CONSOLE, DESK TOP UNIT PATIENT EMERGENCY STATION, WALL MOUNT 56" AFF STAFF EMERGENCY STATION, WALL MOUNT 56" AFF. TOILET ROOMS, 6'-6" AFF TO BOTTOM IN SHOWERS EMERGENCY STATION, WALL MOUNT 48" AFF TO BOTTOM IN STAFF STATION, WALL MOUNT 56" AFF. N SB N VB SINGLE BED STATION WITH TV JACK, WALL MOUNT 48" AFF SINGLE BED STATION WITHOUT TV JACK, WALL MOUNT 48" AFF NOTE REFERENCED. N L NURSE LOCATOR SENSOR D SOUND SYMBOLS S LOUDSPEAKER, CEILING MOUNT SECURITY SYMBOLS CARD READER S CR PANIC ALARM A LIGHTING FIXTURE SCHEDULE TYPE LAMP -VOLTAGE DESCRIPTION FOR ALL RECESSED LIGHTING FIXTURES THE EC SHALL PROVIDE SIDE SUPPORTS, FRAMES AND ACCESSORIES AS REQUIRED FOR CEILING TYPE SHOWN ON ARCHITECTURAL DRAWINGS AND FINISH SCHEDULES. COORDINATE WITH CEILING CONTRACTOR TO DETERMINE MODIFICATIONS REQUIRED TO MAKE FIXTURES SUITABLE FOR CEILINGS IN WHICH FIXTURES ARE TO BE INSTALLED. CATALOG NUMBERS WHICH INCLUDE A CEILING TYPE DO NOT NECESSARILY MEAN THE FIXTURE IS NOT USED IN ANOTHER TYPE OF CEILING. ALL RECESSED INCANDESCENT FIXTURES SHALL EITHER HAVE THERMAL PROTECTION AND SHALL BE SO IDENTIFIED AS THERMALLY PROTECTED IN ACCORDANCE WITH THE NEC ARTICLE #410-65(C) OR SHALL COMPLY WITH EXCEPTIONS #1 OR #2 2 OF THE SAME ARTICLE, CATALOG NUMBERS INDICATED FOR RECESSED INCANDESCENT LIGHTING FIXTURES MAY NOT NECESSARILY INDICATE THIS REQUIREMENT. PROVIDE FIXTURES WITH VOLTAGE AS INDICATED. WHERE VOLTAGE IS ENCRYPTED INTO FIXTURE NUMBER, THE FIXTURE MANUFACTURER SHALL VERIFY PROPER VOLTAGE AS LABELED ON SCHEDULE (AFTER LAMPS). C6 LIGHTOLIER, PRESCOLITE, OMEGA, STAFF, KURT VERSEN, GOTHAM AF 2/26DTT 6AR TRW GEB 10 MULTI-VOLTS DIE-CAST ALUMINUM SOCKET HOUSING, VENTILATED TOP RECESSED, PROVIDE MOUNTING BARS FOR GRID CEILINGS OR TWO (2) 26TRT, T4, HORIZONTAL, AMALGAM RECESSED FLUORESCENT DOWNLIGHT, 6" ROUND OPEN MOUNTING: APPROVED EQUAL: MANUFACTURER: REMARKS: LENS: REFLECTOR: BALLAST: HOUSING: HALO OR KIRLIN WHITE PAINTED FLANGE N/A CLEAR, SPECULAR ALZAK ELECTRONIC, MULTI-VOLTS DRYWALL CEILING VOLTAGE: LAMP: REFLECTOR 120/277 VOLTS TP4 LIGHTOLIER, DAYBRITE, METALUX, COLUMBIA OR HUBBELL LOUVER DOOR TO BE HINGED AND LATCHED IRIDESCENT ALUMINUM 24-CELL, 3" DEEP SPECULAR ANODIZED SLIVER, LOW MATTE WHITE ENAMEL, MINIMUM 90% REFLECTANCE ELECTRONIC, (2) TWO-LAMP, MULTI-VOLTS STEEL HOUSING LAY-IN GRID CEILING 120/277 VOLTS RECESSED 3" DEEP CELL, PARABOLIC TROFFER, 2' x 4' FOUR (4) F32T8 LITHONIA 2PM3N GB432 24LS, MULTI-VOLT APPROVED EQUAL: MANUFACTURER: REMARKS: LENS: REFLECTOR: BALLAST: HOUSING: MOUNTING: VOLTAGE: LAMP: U5 APPROVED EQUAL: MANUFACTURER: REMARKS: LENS: REFLECTOR: BALLAST: HOUSING: MOUNTING: VOLTAGE: LAMP: SURFACE -SEE ARCHITECTURAL DETAILS AND COORDINATE PROVIDE ROCKER SWITCH FOR ALL UNITS WHERE A WALL EXACT INSTALLATION WITH CASEWORK MANUFACTURER UNDER COUNTER, WRAPPED LENS, FLUORESCENT TASK OR APPROVED EQUAL LITHONIA 2UC17 MULTIVOLT-SWR SWITCH IS NOT SHOWN ACRYLIC MILK WHITE N/A ELECTRONIC, TWO-LAMP WHITE STEEL 120 VOLTS ONE (1) F17T8 LIGHT, 1-13/16" x 5-5/16" x 24-1/2" . T I M O T H Y V M OORE PRO FES SIO NAL E N GIN E E R No. 13815A N A I D N I D E RE T S I G E R STATE OF COMMISSION NUMBER DATE SHEET NUMBER SHEET TITLE CERTIFICATION The concepts, ideas, designs, plans, and details as shown on this document are the sole property of MSKTD & Associates, Inc., and were created, developed and presented for use on this specific project. None of the concepts, ideas, designs, plans, and details shall be used by any person, firm, or corporation for any purpose whatsoever, without the expressed written consent of MSKTD & Associates, Inc. The Owner shall be permitted to retain copies for information and reference in connection with this project. 1715 MAGNAVOX WAY FORT WAYNE, IN 46804 voice 260.432.9337 fax 260.436.2402 930 NORTH MERIDIAN INDIANAPOLIS, IN 46204 voice 317.917.1190 fax 317.822.6236 http://www.msktd.com ARCHITECTURE ENGINEERING INTERIOR DESIGN 06/24/2011 6/24/2011 2:31:40 PM 11700 North Meridian Street, Carmel, IN 46032 E001 11023 06-30-11 LDR Reception and C340 Renovation SYMBOLS AND ABBREVIATIONS IU Health North Hospital Revisions: Date: By: L NSS N FV JJ 5 6 F F.8 G G.3 HJ 4.9 7 11 22 LDR C307 Corridor C3C08 Clean Util C342 Nourish Ctr C341 5 6 F F.8 G G.3 HJ 4.9 7 3HNLB1-4 3 3HNLB1-3 3 1 b a a/b TP4 TP4 U5(2) C6(2) LDR C307 Office Cxxx Registration Cxxxa Bereavement C340B Clean Util C342 Nourish Ctr C341 Office C340A GENERAL NOTES: ALL DEVICES, EQUIPMENT, ETC. AS DEFINED ON THE SYMBOLS LIST OR NOTED ON THE DRAWINGS AND SHOWN DASHED SHALL BE REMOVED FROM THE PROJECT. THE ELECTRICAL CONTRACTOR SHALL ELECTRICALLY DISCONNECT AND REMOVE ALL ELECTRICAL COMPONENTS. ALL ELECTRICAL EQUIPMENT OR MOTORS FOR PLUMBING, MECHANICAL, ETC. UNIT SHALL BE ELECTRICALLY DISCONNECTED BY THE EC FOR REMOVAL BY THE CORRESPONDING TRADE. ALL DEVICES, EQUIPMENT, ETC. AS DEFINED ON THE SYMBOLS LIST OR NOTED ON THE DRAWING AND SHOWN SOLID SHALL REMAIN ON THE PROJECT. THE ELECTRICAL CONTRACTOR SHALL MAINTAIN ELECTRICAL CONTINUITY OF THE EXISTING CIRCUIT OR FEEDER WIRING TO DEVICE OR UNIT. VERIFY THE EXACT ROUTE OF WIRING AT SITE AND PROVIDE NECESSARY BRANCH CIRCUIT WIRING TO MAINTAIN CIRCUITS TO REMAIN IN SERVICE AFTER CONSTRUCTION. WHERE A NEW WALL FINISH IS TO BE PROVIDED, THE ELECTRICAL CONTRACTOR SHALL PROVIDE JUNCTION BOX EXTENSION RINGS AND EXTEND EXISTING DEVICES WHICH ARE TO REMAIN FLUSH WITH THE NEW WALL FINISH. THE ELECTRICAL CONTRACTOR SHALL PROVIDE BLANK COVERPLATES FOR ALL REMOVED DEVICES AND OTHER OPEN JUNCTION BOXES BEFORE COMPLETION OF PROJECT. REUSE OF EXISTING CONDUIT IN PLACE IS PERMITTED WHERE SUCH USE IS WITHIN LIMITS OF THE NATIONAL ELECTRICAL CODE AND APPROVED BY THE ENGINEER. REMOVE ALL EXISTING, ABANDONED WIRING AND ALL ACCESSIBLE ABANDONED CONDUIT WHICH IS NO LONGER REQUIRED UNLESS NOTED OTHERWISE. 1. 2. 3. 4. 5. 6. 7. 9. 10.FINAL LOCATIONS OF CEILING MOUNTED LIGHT FIXTURES. REFER TO A DRAWING SERIES OF REFLECTED CEILING PLANS, FOR COUNTS PRIOR TO ORDERING FIXTURES. CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL FIXTURE NOTE: DENOTES SWITCHING ARRANGEMENT DENOTES FIXTURE TYPE DENOTES FIXTURE COUNT a,b FF3(10) INDICATES 2-LAMP BALLAST CONNECTED TO EMERGENCY CIRCUIT. THE SYMBOL NL INDICATES BALLAST IS TO BE UNSWITCHED FOR INDICATES 2-LAMP BALLAST CONNECTED TO EMERGENCY CIRCUIT. 8. CONTINUOUS OPERATION. NL . T I M O T H Y V M OORE PRO FES SIO NAL E N GIN E E R No. 13815A N A I D N I D E RE T S I G E R STATE OF COMMISSION NUMBER DATE SHEET NUMBER SHEET TITLE CERTIFICATION The concepts, ideas, designs, plans, and details as shown on this document are the sole property of MSKTD & Associates, Inc., and were created, developed and presented for use on this specific project. None of the concepts, ideas, designs, plans, and details shall be used by any person, firm, or corporation for any purpose whatsoever, without the expressed written consent of MSKTD & Associates, Inc. The Owner shall be permitted to retain copies for information and reference in connection with this project. 1715 MAGNAVOX WAY FORT WAYNE, IN 46804 voice 260.432.9337 fax 260.436.2402 930 NORTH MERIDIAN INDIANAPOLIS, IN 46204 voice 317.917.1190 fax 317.822.6236 http://www.msktd.com ARCHITECTURE ENGINEERING INTERIOR DESIGN 06/24/2011 6/24/2011 2:31:42 PM 11700 North Meridian Street, Carmel, IN 46032 E203 11023 06-30-11 LDR Reception and C340 Renovation THRID FLOOR DEMOLITION AND LIGHTING PLANSIU Health North Hospital NORTH SCALE: 1/8" = 1'-0" THIRD FLOOR ELECTRICAL DEMOLITION PLAN NORTH SCALE: 1/8" = 1'-0" THIRD FLOOR LIGHTING PLAN PLAN NOTES: 1 REMOVE AND REINSTALL EXISTING TROFFERS TO ACCOMODATE CEILING WORK. 2 REMOVE JUNCTION BOX IN CEILING. 3 EXISTING CIRCUIT SERVING THIS AREA. Revisions: Date: By: 5 6 F F.8 G G.3 HJ 4.9 7 3LNRB3-36 5 1 3LNRB3-38 5 1 3LNRB3-224 3LNRB3-20 4 LDR C307 Office CxxxRegistration Cxxxa Corridor C3C08 Clean Util C342 Nourish Ctr C341 Office C340A Bereavement C340B 5 6 F F.8 G G.3 HJ 4.9 7 3 2 4 LDR C307 Office Cxxx Registration Cxxxa Corridor C3C08 Nourish Ctr C341 Office C340A Bereavement C340B Clean Util C342 GENERAL NOTES: CONTRACTOR WILL BE REQUIRED TO VERIFY ALL OUTLET HEIGHTS WITH APPROVED CASEWORK/MILLWORK SHOP DRAWINGS AND EXISTING CONDITIONS PRIOR TO ANY ROUGH-IN WORK AT CASEWORK/MILLWORK LOCATIONS. CONTRACTOR WILL BE REQUIRED TO FIT ACTUAL DESIGN. 1. SUBSCRIPT NUMBER, I.E. 2/1, AT DATA/TELEPHONE OUTLETS INDICATE CABLE COUNTS TO DEVICES. 2 INDICATES NUMBER OF DATA CABLES, 1 INDICATES NUMBER OF TELEPHONE. A DEVICE WITH NO COUNT INDICATES A SINGLE CABLE FOR DATA AND A SINGLE CABLE FOR TELEPHONE IS REQUIRED. 2. . T I M O T H Y V M OORE PRO FES SIO NAL E N GIN E E R No. 13815A N A I D N I D E RE T S I G E R STATE OF COMMISSION NUMBER DATE SHEET NUMBER SHEET TITLE CERTIFICATION The concepts, ideas, designs, plans, and details as shown on this document are the sole property of MSKTD & Associates, Inc., and were created, developed and presented for use on this specific project. None of the concepts, ideas, designs, plans, and details shall be used by any person, firm, or corporation for any purpose whatsoever, without the expressed written consent of MSKTD & Associates, Inc. The Owner shall be permitted to retain copies for information and reference in connection with this project. 1715 MAGNAVOX WAY FORT WAYNE, IN 46804 voice 260.432.9337 fax 260.436.2402 930 NORTH MERIDIAN INDIANAPOLIS, IN 46204 voice 317.917.1190 fax 317.822.6236 http://www.msktd.com ARCHITECTURE ENGINEERING INTERIOR DESIGN 06/24/2011 6/24/2011 2:31:43 PM 11700 North Meridian Street, Carmel, IN 46032 E303 11023 06-30-11 LDR Reception and C340 Renovation THIRD FLOOR POWER AND SYSTEMS PLANS IU Health North Hospital NORTH SCALE: 1/8" = 1'-0" THIRD FLOOR POWER PLAN NORTH SCALE: 1/8" = 1'-0" THIRD FLOOR SYSTEMS PLAN PLAN NOTES: 1 NEW QUAD RECEPTACLE AT LOCATION OF EXISTING DUPLEX RECEPTACLE. 2 OUTLET BOX AND DATA JACK FOR CHILD WATCH SYSTEM. PROVIDE 3/4" EMT TO CABLE TRAY IN CORRIDOR AND DATA CABLE TO CHILD WATCH CONTROL EQUIPMENT. 3 OUTLET BOX FOR PATIENT MONITORING SYSTEM. PROVIDE 3/4" EMT TO CABLE TRAY IN CORRIDOR. INSTALL CABLE TO PATIENT MONITORING CENTRAL EQUIPMENT. 4 EXISTING CIRCUIT SERVING THIS AREA. 5 CONNECT TO EXISTING SPARE CIRCUIT BREAKER. Revisions: Date: By: