HomeMy WebLinkAboutinforeq43SYMBOL LEG END wP VyGFl V.VIG VJ� ENfC VYD �s �ic ��O son �O w� D �ec �AC 0 Wv Qp v �v Gp v N $z �3 �4 �P �M S �wP �c �o W O PP 0 OS LV OUTLETS LIGHT FIXTURES SINGLE RECEPTACLE (120 VOLT) FLUORESCENT 2X4 FIXTURE STANDARD DUPLEX RECEPTACLE WEATHERPROOF GFCI RECEPTACLE FLUORESCENT 2X4 FIXTURE WITH GROUND FAULT RECEPTACLE PARABOLIC LOUVER ISOLATED GROUND RECEPTACLE FLUORESCENT 1X4 FIXTURE ELECTRIC WATER COOLER RECEPTACLE ON DEDICATED CIRCUIT FLUORESCENT 2X2 FIXTURE SURGE OUTLET ISOLATED GROUND OUTLET FLUORESCENT 2X2 FIXTURE WITH DOUBLE DUPLEX RECEPTACLE (QUAD} PARABOLIC LOUVER CLOCK RECEPTACLE FLUORES(;ENT STRIP FIXTURE SPECIAL EQUIPMENT RECEPTACLE OR CONNECTION WALL MOUNTED FLUORESCENT FIXTURE TWIST LOCK TYPE RECEPTACLE WALL MOUNTED TELEPHONE 48" A.F.F. PENDANT MOUNTED FIXTURES CAT 5/6 ENHANCED (4-PAIR) CABLE (VOICE, PHONE) DUPLEX COMMUNICATION OUTLET (VOICE, DATA) NL NIGHT LIGHT (ON CONTINUOUS) POWER POLE (POWER, TELEPHONE, DATA) RECESSED, EMERGENCY FIXTURE WIRELESS ACCESS POINT (BELOW CEILING} WIRELESS ACCESS POINT (ABOVE CEILING) RECESSED DOWNLIGHT JUNCTION BOX RECESSED EMERGENCY DOWNLIGHT FURNITURE CONNECTION J-BOX POWER FURNITURE CONNECTION J-BOX DATA RECESSED WALLWASH PULL BOX POKE THRU AND OR FLOOR BOX WITH RECEPT AND VOICE/DATA POKE THRU AND OR FLOOR BOX WITH RECEPT AND TV CONNECTION POKE THRU AND OR FLOOR BOX WITH RECEPT, VOICE/DATA, AND AV CONNECTION POKE THRU AND OR FLOOR BOX WITH RECEPT, VOICE/DATA, AND TV CONNECT�ON SWITCHES SINGLE-POLE SWITCH DOUBLE-POLE SWITCH THREE-WAY SWITCH FOUR-WAY SWITCH SWITCH WITH PILOT LIGHT COMB. SWITCH/DUPLEX RECEPTACLE THERMAL OVERLOAD SWITCH MANUAL MOTOR SWITCH KEY SWITCH WEATHERPROOF SWITCH TIMER SWITCH MOMENTARY CONTACT SWITCH DIMMER SWITCH (WATTAGE SHOWN) TOGGLE DISCONNECT SWITCH CEILING MOUNTED LINE VOLTAGE MOTION SENSOR WALL MOUNTED LINE VOLTAGE MOTION SENSOR MOTION SENSOR POWER PACK LOW VOLTAGE OCCUPANCY SENSOR MASTER LOW VOLTAGE OCCUPANCY SENSOR SLAVE LOW VOLTAGE OCCUPANCY SENSOR LOW VOLTAGE SWITCH i SURFACE MOUNTED DOWNLIGHT EXIT FIXTURE (arrows indicates direction of egress) WALL MOUNTED EXIT FIXTURE EXIT FIXTURE WITH TWIN HEAD EMERGENCY LIGHTS WALL MOUNTED FIXTURE HID HI-BAY FIXTURE HID HI-BAY FIXTURE WITH QUARTZ RESTRIKE EMERGENCY EGRESS LIGHT (number of heads shown) EMERGENCY REMOTE HEAD LIGHT TRACK W/ LIGHT TRACK FIXTURE DOCK LIGHT LP1 'Im�m■ml 10■0�01 POLE MTD. FIXTURE GROUND MOUNTED FLOODLIGHT BOLLARD CIRCUITRY AN� RACEWAYS CONDUIT INSTALLED (UNDER SLAB OR UNDERGROUND) CONDUIT INSTALLED (CONCEALED IN WALL, ABOVE CEILING OR EXPOSED) CONDUIT UP CONDUIT DOWN HOME RUN (WITH PANEL DESIGNATIONS AND CIRCUIT NUMBERS) CONDUCTORS (GROUND LONG LINE W/ DOT, NETURAL LONG LINE, PHASE SHORT LINE) #12AWG CONDUCTOR SIZE (UNO) END OF RUN, CAP AND STAKE "RUN CONTINUES" INDICATION FLEXIBLE PIGTAILS/CONNECTIONS PLUGMOLD BUS WAY CABLE TRAY Op FACP FAA NAC ZAM Ea DH FC FS ❑rs PS PIV O BD BD RTS 225 1 1 ioo T s� A� T 1 z FVN R �R� FIRE ALARM PULL STATION COMBINATION HORN AND STROBE DUCT DETECTOR HEAT DETECTOR SMOKE DETECTOR FIRE ALARM CONTROL PANEL FIRE ALARM ANNUNCIATOR PANEL FIRE ALARM SIGNAL CONTROL FIRE ALARM CONTROL MODULE END OF LINE DEVICE STROBE ONLY FIRE ALARM SIGNAL DOOR HOLDER FIREFIGHTER COMMUNICATION JACK FLOW SWITCH TAMPER SWITCH PRESSURE SWITCH POST INDICATING VALVE EXTERIOR BELL BEAM DETECTOR BEAM DETECTOR REFLECTOR REMOTE TEST SWITCH ONE-LINE DIAGRAM SCHEMATIC SYMBOLS CIRCUIT BREAKER 225 FRAME SIZE (AMPERES} 100 TRIP SETTING (AMPERES) KNIFE SWITCH OR DISCONNECT SWITCH FUSE (AMPERAGE SHOWN) FUSED KN{FE SWITCH 3 PHASE MOTOR STARTER NUMBER INDICATES NEMA SIZE #2 LETTERS INDICATES STARTER TYPE FVNR=FULL VOLTAGE NON-REVERSING CONTROL TRANSFORMER KvA POWER TRANSFORMER (KVA SHOWN} a J AM r 0 O AUTOMATIC TRANSFER SWITCH POTENTIAL VOLTAGE TRANSFORMER CURRENT TRANSFORMER THERMAL OVERLOAD (O.L.) LIGHTNING ARRESTER AMMETER VOLTMETER GROUND CONNECTION NOTE DESIGNATIONS REVISION NOTE FEEDER NOTE KEY NOTE SERVICE AN� EQUIPMENT T� TRANSFORMER, PAD MOUNTED T� TRANSFORMER, DRY TYPE (KVA SHOWN) G PANELBOARD �cP LIGHTING CONTROL PANEL NON FUSED DISCONNECT SWITCH FUSED DISCONNECT SWITCH COMBINATION STARTER UTILITY METER, AS REQUIRED �T CURRENT TRANSFORMER CABINET GENERATOR, KW SHOWN �T�� TELEPHONE TERMINAL BOARD n� TELEPHONE TERMINAL CABINET O GROUND ROD AUTOMATIC TRANSFER SWITCH MAGNETIC STARTER SOUND AN� SIGNAL OS RECESSED CEILING SPEAKER I WALL MOUNTED SPEAKER vc VOLUME CONTROL QQ Q P.A. HORN �z BUZZER DOOR BELL DOOR CHIME Q CALL IN SWITCH �..0 TELEVISION OUTLET ROUGH-IN AUDIO VISUAL OUTLET QM MICROPHONE OUTLET ic INTERCOM OUTLET Q NURSE CALL PULL STATION NURSE CALL DOME LIGHT oc DOOR CONTACT KEY PAD cR CARD READER O�J CAMERA PUSH BUTTON REx REQUEST TO EXIT SENSOR O TC e PB ATC ECP MECHANICAL EXHAUST FAN CEILING TYPE FAN PADDLE TYPE FAN WALL TYPE FAN PIPE HEAT TRACING UNIT HEATER ELECTRIC E3ASEBOARD HEATER ELECTRIC CABINET HEATER ELECTRIC WATER HEATER MOTORIZED CONTROL DAMPER CONTROL THERMOSTAT (LINE VOLTAGE UNO.) HUMIDISTAT (LINE VOLTAGE UNO.) PHOTOCELL TIME CLOCK PUSHBUTTON STATION LIGHTING CONTACTOR TEMPERATURE CONTROL PANEL EQUIPMENT CONTROL PANEL SCHEDULE OF STANDARD MOUNTING HEIGHTS FOR ROUGH-IN OF ELECTRICAL DEVICES b. GENERALLY MOUNTING HEIGHTS OF DEVICES C. SCHEDULE NOTES: ARE TO BE AS FOLLOWS: 1. MOUNTING HEIGHTS ARE ABOVE FINISHED FLOOR TO CENTER OF (HEIGHTS GIVEN ARE TO CENTER OF DEVICE BOX) OUTLET (DEVICE) BOX, UNLESS OTHERWISE NOTED OR INDICATED D. AMERICANS WITH DISABILITIES ACT (ADA) NOTES: FACILITIES COMPLIANCE (A.F.F. ABOVE FINISHED FLOOR) (B.F.C. BELOW FINISHED CEILING) ON THE DRAWINGS OR SPECIFICATIONS BY SPECIFIC NOTES OR WORKBOOK} CHAPTER 11 OF THE 1998 INDIANA B ILDING CODE DETAILS. INDIANA ACCESSIBILITY CHAPTER 1. RECEPTACLES, GENERAL: +1'-4" A.F.F. 2. WALL SWITCHES, GENERAL: +4'-0" A.F.F. 2. REFER TO ELECTRICAL SPECIFICATIONS FOR ADDITIONAL 1. OPERATING CONTROLS; INCLUDING BUT NOT LIMITED TO RECEPTACLES, SWITCHES 3. RECEPTACLES OVER WORKBENCHES, TABLES, ETC.: +4'-2" A.F.F. INFORMATION ON DEVICE/OUTLET BOX INSTALLATION WALL MOUNTED TELEPHONES, ETC... 4. TELEPHONE OUTLETS: OVER WORKBENCHES, TABLES, ETC.: REQUIREMENTS. +4�-2�� A.F.F. A. MOUNIING HEtGHTS ARE TO THE HIGHEST OPERABLE PART OF THE CONTROL AND SHALL BE PLACED WITHIN AT LEAST ONE OF THE REACH RANGES 5. TELEPHONE OUTLETS: +1' A.F.F. (DESK TYPE) 3. GENERAL REQUIREMENTS FOR OUTLET BOX INSTALLATION IN SPECIFIED IN ARTICLE 4.2.5 AND 4.2.6 OF CHAPTER 11 OF THE INDIANA 6. WALL TELEPHONE OUTLETS: +5' A.F.F. CONCRETE BLOCK OR TILE WALLS: BUILDING CODE INDIANA ACCESSIBILITY CHAPTER 7. WALL PUSHBUTTONS: +4 '-0" A.F.F. (1) MOUNTING HEIGHTS OF THE ABOVE MENTIONED CONTROLS ARE TO BE 8. MOTOR CONTROLLERS: +6'-0�� TOP OF BOX A. IT IS INTENDED THAT OUTLET BOXES SHALL BE SET ON TOP CONSIDERED FROM TWO (2) VANTAGE POINTS AS FOLLOWS 9. DISCONNECT SWITCHES: +6'-0" TOP OF SWITCH OF A BLOCK (TILE) COURSE BELOW, WITH THE OUTLET 10. FIRE ALARM PULL STATIONS: +4'-0" A.F.F. SPACE CUT INTO THE BOTTOM OF THE BLOCK (TILE) COURSE a. FORWARD REACH IF THE CLEAR FLOOR SPACE ONLY ALLOWS FORWARD 11. FIRE ALARM HORNS, BELLS, GONGS: +80 A.F OR 12 B.F.C. ABOVE. APPROACH TO AN OBJECT, BY A PERSON IN A WHEELCHAIR, THE MAXIMUM 12 THERMOSTATS -f-4'-6" HIGH FORWARD REACH ALLOWED SHALL BE +48" A.F.F. AND THE MINIMUM 13. RECEPTACLES/DEVICES MOUNTED ABOVE COUNTERTOP B. OUTLETS SHALL BE INSTALLED IN NEAREST BLOCK (TI�E) LOW FORWARD REACH ALLOWED SHALL BE +15" A.F.F. IF THE FORWARD REACH IS OVER AN OBJECT; THEN THE MAXIMUM HIGH FORWARD REACH BACKSPLASH: +2"(MIN) COURSE TO THE SCHEDULED MOUNTING HEIGHT. SHALL BE ADJUSTED ACCORDING TO ARTICLE 4.2.5 FIG. 5(b) OF CHAPTER 14. RECEPTACLES/DEVICES MOUNTED ABOVE RADIANT HEATERS: +6"(MIN.) 11 OF THE INDIANA BUILDING CODE INDIANA ACCESSIBILITY CHAPTER. 15. WALL MOUNTED SPEAKERS: +8'-0" 4. SPECIAL PURPOSE DEVICES (THOSE SERVING: COMMERCIAL 16. CARD READER: +3'-6" A.F.F. KITCHEN EQUIPMENT, ELECTRIC WATER COOLERS, APPLIANCES b. SIDE REACH IF THE CLEAR FLOOR SPACE ALLOWS PARALLEL APPROACH 17. EMERGENCY LIGHTING UNITS: (OFFICE) +7'-0"A.F.F. OR 12"B.F.C. ETC.} SHALL BE IN AGREEMENT WITH APPROVED SHOP DRAWINGS. BY A PERSON IN A WHEELCHAIR, THE MAXIMUM HIGH SIDE REACH ALLOWED (WAREHOUSE) +12' A.F.F. SHALL BE +54" A.F.F. AND THE MINIMUM LOW REACH SHALL BE NO LESS 18. WALL MOUNTED, STAIRWELL LANDING, LIGHT FIXTURES: +7'-0" A.F.F. 5. TOGGLE TYPE SWITCHES, LIGHT SWITCHES AND MANUAL MOTOR THAN +9" A.F.F. IF THE SIDE REACH IS OVER AN OBJECT THEN THE 19. WALL MOUNTED SPEAKERS: +8'-0" A.F.F. OR 12" B.F.C. STARTERS, MOUNTED ABOVE BACKSPLASH OF COUNTERTOPS SHALL MAXIMUM HIGH SIDE REACH SHALL BE ADJUSTED ACCORDING TO ARTICLE 4.2.6 FIG. 6(c) OF CHAPTER 11 OF THE INDIANA BUILDING CODE INDIANA 20. ELECTRICAL PANELS: 6'-0" TOP OF 80X BE MOUNTED AT SAME HEIGHT AS RECEPTACLES. ACCESSIBILITY CHAPTER 21. DIMMING PANELS: 6'-0" TOP OF BOX IB. EXCEPTIONS TO REQUIREMENTS OF SCHEDULE: 6. COORDINATE DEVICE MOUNTING HEIGHTS WITH ARCHITECTURAL 2. IF CONTRO�S DISPENSERS, RECEPTACLES, OR OTHER EQUIPMENT ARE PROVIDED CASEWORK SHOP DRAWINGS. �IN BATHROOMS BATHING FACILITIES, AND SHOWER ROOMS), THEN AT �EAST ONE OF EACH" SHALL' BE ON AN ACCESSIBLE ROUTE AND SHALL 1. AT JUNCTION OF DIFFERENT MATERIALS IN WALL FINISHES. COMPLY WITH ARTICLE 4.27 OF THE FEDERAL REGISTER/VOL. 58 N0. 144/FRIDAY JULY 26, 1991 /RULES AND REGULATIONS. 2. WHERE OUTLETS WOULD OCCUR IN MOLDINGS, BREAK IN WALL SURFACE, OR UNSUITABLE LOCATION IN TILE, WOOD OR SIMILAR 3. ALARMS; ARTICLE 4.25 FINISH. A. MOUNTING HEIGHTS OF VISUAL ALARMS SHALL BE PLACED AT +80" ABOVE THE HIGHEST FLOOR LEVEL WITHIN THE SPACE OR 6" BELOW THE CEILING, 3. WHERE OUTLETS WOULD CONFLICT WITH LOCATIONS OF WALL WHICHEVER IS LOWER. ARTICLE 4.25.3 SUB ARTICLE (f). MOUNTED EQUIPMENT, SUCH AS RADIATORS, CONVECTORS, UNIT HEATERS ETC. 4. PROTRUDING OBJECTS; ARTICLE 4.4 (WALL SCONCES, HAND DRYERS, ETC...) 4. AS NOTED OR INDICATED OTHERWISE ON DRAWINGS OR IN A. GENERAL. OBJECTS PROJECTING FROM WALLS WITH THEIR LEADING EDGES SPECIFICATIONS BETWEEN +27" A.F.F. AND +80" A.F.F. SHALL PROTRUDE NO MORE THAN FOUR (4) INCHES INTO WALKS, HALLS, CORRIDORS, PASSAGEWAYS, OR AISLES. PROTRUDING OBJECTS SHALL NOT REDUCE THE CLEAR WIDTH OF AN ACCESSIBLE ROUTE OR MANEUVERING SPACE. nirs �wwi� Mo �u irFOwu►riw w ir is r� �rr ff c,�ncK. iNC. tT ts CD�IIOITIAL A!D Il'S i1�lISSId! Ot DIS'iRI1UTIql TD lEET �FICIAL AEtt�1�ATdtY iiE�JiRE1QITf Ot Fpt QIFER PI�SEY IN CalECTIW YI?M iMIY PAO.�CT IS I�T 70 �!�lSTilltD AS PIAI.ICATIOi IN �AO�iATIDi GAYL�t, INC.'S COy01 LAY t�YRICif� Qt QIFER NESERVED RIQITY. TMIS 11E11yING ►pt ANY PMtT 1T. I�t ANY It�'QUMTIDI COCFJMIING IT IMY 1E C�Im. Da1ISI7ED. AEPAmUCm Qt F1RalISF�D TO QfFER! IiOt MAT PlOTOGRAPMt lC TAI�7� ANY ARTfCLE FAIRICATED Ot AiSQIR�D FRDI TMIS �tAYIt�i YI7F� YRI7'IEN Cd�OiT ff GI11M1.Ot. tNC. C�YRIGHT 1Y GA1fLOt, iliC. 2011. W W Q CLJ Z U Z W A Q A Q H p4 W W (U d' I!� �D Z J Q O �O ��Z W �W J Q '�U O W O r M CO F- C N Cp I� O O O Z�''� U U ��'llj� O OtL� Z�jO Y M N J N 0 N Q Z C� M 2 a. CERTIFIED BY� DRAWING TITLE; SYMBOL LEGEND DRAWN BY� BET DATE� 07-15-11 SCALE� NONE APPR�VED� RLL/JDS DRAWING N�� E-� o0 GENERAL NOTES APPLY TO ALL ELECTRICAL SHEETS 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. ALL MATERIAL AND WORKMANSHIP SHALL COMPLY WITH ALL APPLICABLE 11. CODES, SPECIFICATIONS, LOCAL ORDINANCES AND INDUSTRY STANDARDS. 12. NATIONAL ELECTRICAL GODE <NEC> AND INDUSTRY INSTALLATION STANDARDS SHALL BE CONSIDERED MINIMUM STANDARDS. 13. AL� CONDUITS AND BOXES SHALL BE PROPERLY SUPPORTED. ALL GRS OR IMC CONDWITS ENTERING BOXES OR ENCLOSURES WITHOUT HUBS SHALL BE EQUIPPED WITH BUSHINGS AND SHALL HAVE LOCKNUTS INSIDE AND OUT OF ENCLOSURE. 14. ALL NECESSARY HANGERS AND/OR MOUNTING ACCESSORIES FOR LIGHTING FIXTURES SHALL BE SUPPLIED BY E.C. VERIFY ALL DIMENSIONS FROM ARCHITECTURAL PLANS. 15. DIMENSIONS SHOWN ON OUTLET BOXES SHALL BE FROM THE FINISHED FLOOR TO THE CENTER OF THE BOX. COORDINATE LOCATION OF LIGHTS IN ROOMS CONTAINING EXPOSED DUCTWORK AND PIPING BY OTHER TRADES. 16. VERIFY ELECTRICAL CHARACTERISTICS AND ROUGH-IN REQUIREMENTS FOR ALL EQUIPMENT FURNISHED BY OTHERS AND CONNECTED BY E.C. 17. COORDINATE LOCATION QF MOTOR STARTERS, DISCONNECTS, PANELBOARDS, ETC. IN ROOMS CONTAINING EXPOSED DUCTWORK AND 18. PIPING BY OTHER TRADES. VERIFY HEIGHT AND LOCATION OF OUTLETS BEHIND WATER COOLERS WITH OTHER TRADES, SO THAT OUTLETS ARE CONCEALED. REFER TO ARCHITECTURAL PLANS FOR DETAILS AND NOTES CONCERNING ITEMS INVOLVING ELECTRICAL WORK. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN FOR CEILING TYPES AND FIXTURE LOCATIONS. ANY CONFLICTS BETWEEN ELECTRICAL PLANS AND REFLECTED CEILING P�ANS SHALL BE REPORTED AND RESOLVED PRIOR TO ROUGH-IN. REFER TO ARCHITECTURAL PLANS FOR FINAL DOOR SWING AND LIGHT SWITCH LOCATIONS. ANY CONFLICT BETWEEN ELECTRICAL PLANS AND ARCHITECTURAL PLANS SHALL BE REPORTED AND RESOLVED PRIOR TO ROUGH-IN. REFER TO ARCHITECTURAL PLANS FOR ELEVATIONS OF CASEWORK AND/OR BUILT-IN SHELVING UNITS TO COORDINATE OUTLET ELEVATIONS. ANY CONFLICT BETWEEN ELECTRICAL PLANS AND ARCHITECTURAL PLANS SHALL BE REPORTED AND RESOLVED PRIOR TO ROUGH-IN. ALL FEEDERS AND BRANCH CIRCUITS RAN UNDERGROUND IN PVC CONDUIT SHALL INCLUDE A GROUND CONDUCTOR. ALL DISCONNECT SWITCHES LOCATED OUTDOORS SHALL BE NEMA 3R (u.N.o.) ALL DISCONNECT SWITCHES LOCATED INDOORS SHALL BE NEMA 1 (u.N.o.) ALL DISCONNECT SWITCHES LOCATED IN CORROSIVE ATMOSPHERES SHALL BE NEMA 4X (U.N.O.) 19 ELECTRI CAL ABBREVIATI ONS A AMPERE(S) GALV GALVANIZED NEMA NATIONAL ELECTRICAL AC ALTERNATING CURRENT GF GROUND FAULT MANUFACTURERS ASSOCIATION AFF ABOVE FINISHED FLOOR GFI GROUND FAULT INTERRUPTER NEC NATIONAL ELECTRICAL CODE AL ALUMINUM GFP GROUND FAULT PROTECTION NF NON-FUSED AMP AMPERE(S) GND GROUND NTS NOT TO SCALE ASHRAE AMERICAN SOCIETY OF REFRIGERATING HH HANDHOLE OL OVERLOAD AND AIR CONDITIONIN� ENGINEERS HID HIGH INTENSITY DISCHARGE 2P TWO POLE ATS AUTOMATIC TRANSFER SWITCH HOA HAND-OFF-AUTOMATIC PB PUSHBUTTON BLDG BUILDING HOR HAND-OFF-REMOTE PVC POLYVINYL CHLORIDE BKR BREAKER HOAR HAND-OFF-AUTO-REMOTE RGS RIGID GALVANIZED STEEL C CONDUIT HP HORSEPOWER SP SINGLE POLE 2/C TWO CONDUCTOR (TYP) HPS HIGH PRESSURE SODIUM SPDT SINGLE POLE DOUBLE THROW CB CIRCUIT BREAKER IMC INTERMEDIATE METAL CONDUIT SPEC SPECIFICATION CKT CIRCUIT JUNCTION BOX SPST SINGLE POLE SINGLE THROW CPT CONTROL POWER TRANSFORMER KV KILO VOLTS STR STARTER CPU COMPUTER KVA KILO VOLTS-AMPS SW SWITCH CR CONTROL RELAY KVAR KILOVAR TTB TELEPHONE TERMINAL BOARD CT CONTROL TRANSFORMER LA LIGHTNING ARRESTOR TYP TYPICAL LTG LIGHTING CU COPPER LOR LOCAL-OFF-REMOTE UNO UNLESS NOTED OTHERWISE DISC. DISCONNECT UL UNDERWRITERS LABORATORIES MS MAGNETIC MOTOR STARTER COIL DT DUST TIGHT V VOLTS MAX MAXIMUM DWG DRAWING VFD VARIABLE FREQUENCY DRIVE MCC MOTOR CONTROL CENTER EF EXHAUST FAN VS VOLTMETER SWITCH MD MOTORIZED DAMPER ELEV ELEVATION W WIRE OR WATT EM EMERGENCY MFR MANUFACTURER W� WITH EQUIP EQUIPMENT MH MANHOLE yy�0 WITHOUT EWC ELECTRIC WATER COOLER MIN MINIMUM yyP WEATHERPROOF EP EXPLOSION PROOF N NEUTRAL XFMR TRANSFORMER N/A NOT APPLICABLE FMC FLEXIBLE METALLIC CONDUIT XFR TRANSFER FVNR FULL-VOLTAGE NON-REVERS�NG sb PHASE FVR FULL-VOLTAGE REVERSING GROUND