Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Application ADLS
Date DOCKET NO.' APPLICATION for ARCHITECTURAL DESIGN~ LIGHTING~ and SIGNAGE FEE' $700.00 (Plus $35.00 per acre when NOT accompanied by a Development Plan) Name of Project: Mike's Express Car Wash "'::~" Address: 1250 South Rangeline Road, Carmel, IN 46032 Type of Project: Car Wash- Automated and Self Serve Applicant: Mike's Car Wash, Inc. Phone No.: (317) 580-8875 Contact Person: Bill Dahm Phone No.: (317) 580-8875 Address: 11711 North College Avenue, Carmel, IN 46032 Engineer/Architect: Paul I. Cripe, c/o Gary_ Murray and Todd Bauer Phone' 842-6777 Fax: 841-4798 Attorney' Charles D. Frankenberger,.Nelson & Frankenberger, 3105 E. 98th Street, Suite 170, Indianapolis, IN 46280 Phone: 844-0106 Fax: 846-8782 Legal Description: See Exhibit "A" Parcel Numbers: 16-09-36-04-02-006.000 and 16-09-36-04-02-004.000 Area ( in acres ) + 2.13 acres, more or less Zoning I-1 Industrial District Owner of Real Estate' Gary R.Major Carmel Car Wash Inc. and Richard E. and Catherine L. Maior and Carmel: X Clay Township' Annexation: Y or N Other Approvals Needed: Sign Variance Approval- Development Plan Approval PARKING No. of Spaces Provided: See attached plans No. Spaces Required: DESIGN INFORMATION Type of Building: Car Wash-Automated and Self-Serve No. of Buildings' 2 Square Footage' See attached plans Height: See attached plans No. of Stories: 1 Exterior Materials: See attached plans Color: See attached plans Maximum No. of Tenants N/A Type of Uses: Automated and Self Serve Car Wash Water by: Carmel Sewer By: Carmel LIGHTING Type of Fixture' See attached plans Height of Fixture' See attached plans No. of Fixtures: See attached ~lans _ Additional Lighting' * Plans to be submitted showing foot candle spread at property lines, per Ordinance. SIGNAGE No. of Signs: See attached plans & drawings Type of Signs: See attached plans & drawings Location(s)' See attached plans & drawings Dimensions of each sign: See attached plans & drawings Total Height of each sign: See attached plans & drawings LANDSCAPING * Plans to be submitted showingplans types, sizes, and locations. See attached plans & drawings ' m~d co~ ~'sc~~A~~c. /~ wiilia~.~si~ ~ . EXHIBIT "A" Part of the Southeast Quarter of Section 36, Township 18 North, Range 3 East in Hamilton County, Indiana described as follows: Commencing at the Northeast corner of the Southeast Quarter of Section 36, Township 18 North, Range 3 East in Hamilton County, Indiana; thence South 00 degrees 00 minutes 00 seconds West (assumed bearing) on the East line of said Southeast Quarter 938.15 feet to the South right-of-way of Carmel Drive; thence South 90 degrees 00' minutes 00 seconds West on said South right-of-way line 235.00 feet to the Northeast corner of the real estate described as Parcel II in Deed Book 248, Page 87 recorded in the Office of the Recorder of Hamilton County, Indiana, said point also being the point of beginning of the tract herein described; thence continuing South 90 degrees 00 minutes 00 seconds West on the North line of said real estate 165.05 feet to the centerline of the old Traction Company right-of-way; thence South 00 degrees 45 minutes 10 seconds West on said center line 366.30 feet to the Northwest corner of the real estate described in Instrument #8702632 recorded in said Office; thence South 89 degrees 41 minutes 58 seconds East (this and the following 2 courses are on the North line of said real estate) 184.86 feet; thence North 00 degrees 00 minutes 00 seconds East 36.10 feet; thence South 89 degrees 41 minutes 58 seconds East 220.00 feet to the Northeast corner of said real estate, said point being on the East line of said Southeast Quarter Section; thence North 00 degrees 00 minutes 00 seconds East on said East line 132.30 feet to the Northeast corner of the real estate described as Parcel I in said Deed Book 248, Page 87; thence South 90 degrees 00 minutes 00 seconds West on the North line of said real estate 235.00 feet to the Southeast corner of the real estate described as Parcel I in said Deed Book 248, Page 87; thence North 00 degrees 00 minutes 00 seconds East on the East line of said real estate 200.00 feet to the point of beginning, containing 2.13 acres, more or less. subject to the right-of-way for Carmel Drive. Subject to the right-of-way for Range Line Road. C~t'l~e] Mike'~ ~ide ~treet ID: ;~9.?*J~ CarmsI Dr. Scale: 1/4":1-0" Carnal Dr. Mike's Enter ~ign: 2.88~ Menu ~ign~20.75~ On a, it~ Book ~ign.2~J.84~ 1/2"'1:0" Bosed on the informotion provided otl dimensions ond luminoire Iocotions shown represent recommended po;~itions. The eneineer ond/o.r orchitect must determine opplicobility of the Ioyout to existing oF future find conditions. ,Th, is lightipcj pottern represe,,').ts illuminotion levds colculeted ,from,.Iob. orotory token unoer controlled conditions ~n occordonce with lllum~no~,nq r_qq,leermcj oppr(~ved method~i Actuo oerformonce of onv rnonufocturer s Iumm'ere mov v~rv oue to w3rm{ion in dectrt~:ol volto(J~, toleronce in IomC)s, ond Other vonoble held cohditioh$. : : : o.o ~ ~.o o.o ... o.o {;_.r, ~ ~ t~ - ~.~..~.r~...~.-..~ · : · · I.~,~ o.! : o.2":-; 4-_ : · .. o., ~'"'il i~ o.o o.~ '.. o.1 o.1 o.~ o.o o.I o.~ o.1 o.1 o.1 o.1 o.o o.o o.o 3.6 ~.5 ~3. g 3,3.4 44.3 Jl.0 13.2 27.0 ~ 24.5 24.3 11,1 H ~o i o.I Go t Q .! Q.0 i o.1 o.i o,~ .;- .G,~. ~. ~ o.2 -FP-H$$ Numeric Summory Project: All Projects ,,, Lobel LOT1 [.., ; I I~$ 7.B 5.5 S.B 13.4 7.5 G~ Gt ~1 ~t 0.1 ~1 0.1 0.1 Gl ~ 0.10.1 0. t 0.1 ~0~ ~0 ~ 0.O 0.0 GO 0.0 0.0 ,, ~.t~ 0.~ ~i ).7:~ ,.7 ~,.0 :,,.~z ~.~ L~ ,.~ ~ ~ ~2 ~4.a 22.7~c~ o.a ~.2 7.~ rog., 2.5 ~.5 6.~ ~.~ ~.9 ~.6 : ,.9 ~ 6.2 ~.~ ~ 0.~ ~ ~ 0.0 0.0 qo 0.0 0.0~ ' ' ..... ,~: ................................................ ~ ...... "" o., :o.,~I ,.,[:~,-~ ..... ~ ............. ~ .... ~ ...... , i,~ ,~ '~ .................. , ......................, ,., ~ ,.,[ ~.. ,~ ' . ~ .......................~.~.L ..... ~,,..[ ......................................................................................................................................... ; .... '-- ] ' ' ' ~ .... ' ...... '. ~, ' ~g~ '~"~r ' "~:~ '~' ~ 4 ~ 230 ~0 72 ~J 2s J8 ~8 114B7 g3 26 9 ~6 2a z5 J 01 0 oo Z~ ~.~, ~ ,~ ~-~ (~ ~ ~/ I ! ........................................................................... ~ ............................. ~ ~*~.! ~ ~ 'I [ ']. ' ' : - ' C,'2:. r <' ! '~ ' ~ 't <' ~' I' ~ ~ ~ ......................... e- l I ~ ~:.~-.-.,'-..'-./-.-:-.-':.-~-:,~-.~-.-'-.;-.-~ T ~-rr-,,a~ ' T ....- .... f I ~-~ '~"'"':":'~ * : · GOt& ' I ~.~', ....1 o~ GO o~ ~1 ~ ~ 5SOBO- S110 - 18- S- 5BC OTHER ASSEMBLIES EACH CONSISTING OF: BILL OF MATERIALS Revisions Dote Revision Notes New Site Plons GREENBRIAR FLAT LENS SITE LIGHTING NOTES' T. '~"E£ bow LEVELS AR~ M^~N~^~D ~T, ^ .~0 UO, T'LOS~k~Cf¢~?~ ~'~ ....... CALCULATED AT GRADE.' 2. ALL LIGHT FIXTURES HAVE A FLAT LENS. AND ARE CLASSIFIED AS A FULL CUT-OFF LIGHT FIXTURES. 3. ALL POLES ARE 18' TALL MOUNTED ON BASES WHICH EXTEND 2' A.F.G. ASSEMBLY 5SQBO-S1 G-18-D180- POLE BRACKET IColcTy13e Illuminonce l u,~t. 1 "'w I''"o'' !""" I^~/''''"1~°'/u'' rc I 8.~6 i 77.9 I 0.0 I0.00 I 0.00 CFR-FP- 1000-MHR-F- HSS CFR -FP- 1000- MHR - F- H SS FIXTURE 1080 2160 $6720 TOTAL WATTS ~855 KOPETSKY DRIVE SUITE INDIANAPOLIS IN 46217 MIKES CARWASH !29 CARMEL INDIANA SC ALE' 1"-30' 12.10.0..3 BY: W.C.P. L ALL PAMONG 5Ta~ SH~ BI: I0' X 2~' ~ I0' X Ii' Ul(l[ AO#CI~ I0 ~OLW~LK M C201 0030407-20000 . .. t GREENBRIA,R FLAT LENS Fixtures with flat lens meet IESNA full cut-off classification. cQu, LISTED listed for wet locations. ©2003 LSI Industries Inc. 8/1/03 THE GREENBRIAR® FLAT LENS SERIES Various reflectors are protected by U.S. Patents No. 6,464,378, LSI's Oreenbriar Flat Lens Series uniquely COaT, bines the high performance and benefits of traditional vertical burn technology, with the full cut-off distribution afforded by a flat. lens. Specially designed reflectors provide uniform, high performance lighting while the flat glass lens ensures the full cut-off distribution as defined by IESNA, thus meets stricter zoning requirements. Designed around a reduced envelope lamp, the compact, top-access fixture is easy to install and service. SPECIFICATIONS HOUSING The aluminum housing is available in two sizes: Greenbriar Flat Lens Reduced Envelope 1000 Watt lamp and Greenbriar Flat Lens Reduced Envelope 400 Watt lamp. Both REFLECTORS/DISTRIBUTION BALLAST PATTERNS Metal Halide and High Pressure The series is available in a variety of Sodium fixtures feature a High- reflector systems and distribution power factor type (;WA ballast. patterns, all with vertical oriented All ballast types are designed for lamps: -20'F operation. housings are the same dimensions GFR: Type II (2),Type III (3), square, however, the GFR is deeper. Perimeter Forward Throw (FP), Both are finished to produce a clean, sharp appearance, and designed to ensure weather-tight construction. Top-access covers provide ease of installation and servicin9. LENS/GASKET The flat clear tempered glass lens is sealed to the housing with an EPDM gasket, preventing entry of moisture, dust and insects. TOP FASTENERS The four captive stainless steel BRACKETS Arm IVIounI: 2-1/2"× 5-3/8" x 12" Type V (5) and Automotive Forward extruded aluminum bracket is Throw (FA). shipped standard. An 8" bracket is GFM: Type I! (2), Type III (3), available for single or D180"' Perimeter Forward Throw (FP), and Type V (5). Field-rotatable reflectors provide flexibility in distribution patterns without moving the fixture. Photometric data is tested in accordance with IESNA guidelines. FINISHES Each fixture is finished with LSI's DuraGrip® polyester powder coat door fasteners secure the top-access finishing process. The DuraGrip finish withstands extreme weather cover to the t~ousin9. changes without cracking or SOCKETS peeling, and is guaranteed for five Porcelain mogul-base sockets. All full years. Standard colors include sockets are pulse-rated, bronze, black, platinurn plus, buff, white and green, LIGHT SOURCES configurations, but must be ordered frorn the Options column of the ordering chart. A Round Pole Plate (RPP2) is required for mounting to 3"-5" round poles. (See Accessories chart.) Pole Top: The cast aluminum mounting hub conceals the wiring compartment and mounts directly to LSI's unique "pole-top mounting plate", via a high-strength grade five steel bolt with nylon insert and split lock washer for double locking. Support arms consist of four 11/16" O.D. aluminum rods and are pre- wired for ease of installation. POLES Refer to Poles/Brackets section Pulse-Start Metal Halide, Metal DECAL STRIPING of catalog for pole Halide, Metal Halide Reduced LSI offers optional color- ~-.~i:., Envelope, or High Pressure Sodium. coordinated decals in 9 standard x Clear lamp is supplied as standard, colors to accent the fixture. Decal is ,~,,/ guaranteed for five years against /~i:'"' peeling, cracking, or fading. ~ / "-/~- PHOTOMETRICS ~(~.~_ For detailed photometric data, please visit our website at www.lsi-industries.com · . g SysfemsTM 10000 Alliance Road · Cincinnati, Ohio 45242 · (513)7.93-3200 FAX (513)793-0147 · www.lsi-industries.com G REE N BRIAR - FLAT "~ s~'~'~'''~ ~ [~?it'_~l['I .~// ~ LENS DIMENSIONS ~ii Bracket - L12 2-bolt Arm Mount Pattern ........... , ,,, r--A ~ A B C "'GFM Arm Mount 21-5/8" 12-3/4" '- .... ..... GFPM Pole Top 21-$/8" 12-314" 21.-15116" GFR Arm Mount 21-5/8" 16-1/8" GFpR Pole Top 21-5/8" 16-1/8" 25"' ....... .... Pole Top Mount iiiii1!111! Il Il!! !! II I In imml)H) i iiiiiiqM~lllllllllll iii LUMINAIRE EPA CHART Includes bracket. . ~,~ ~ ~ m-~m '~ ~ Pole Top Mount Single D90' D180- Tgo' TN120- Q90~ ,, , Greenbriar Flat. t2" Arm Mount Bracket (GF.M) -- m m 3.2 5.7 6:3 8.8 . 9.0 11.3 Greenbriar Flat - Pole Top {.GFPM) 3.2 ..................... Greenbriar Flat-. t2; Arm M,:)unt Bra(:keL (GFR) ..... 3.8 ' '7.6 7.6 !1.4' ~ .11.4 '15-2 i...'.'. Greenbriar Flat-- Pole Top (GFPR) 4.0 · ........................ ii i ii ii iiii i iii i i ii ii ii iii iiiii ii ii i i ii , , , LUMINAIRE ORDERING INFORMATION Select appropriate choice from each column to formulate order code. Refer to example below, Luminaire Lamp Line Luminaire Options Prefix Distribution Wattage Light Source Lens Volta.qe3 Finish ......... ,, Medium 2 Type Il ;'50 PSMV -. Pulse-Start Metal F Flat Clear 480V BRZ Bronze 8BK - 8" Bracket6 Vertical Burn 3 -- Type Itl 320 Halide 250, 320 Watt Tempered MT MLdti Tap4 BLK .- Black PCI120V Button-Type Photoelectric Control7 GFM-- FP Perimeter 400 SMVR Super Metal Halide Glass TT- Tri-Taps PLP- Platinum Plus PCI208V Button-l'ype Photoelectric Control7 Arm Forward Throw Reduced Envelope 400 Watt Bur .. Buff PCI240V BuU. on-Type Photoelectric Control7 Mount ,5 Type V MH Metal Halide WHT- White PCI277V Button-Type Photoelectric Control? 250 Watt GRN Green LL -- Less Lamp GFPM MHR- Metal Halide Reduced Pole Top't Envelope 400 Watt Color Decals HPS .... High Pressure Sodium 45 - L.i.qht Gold Metallic I 250, 400 Watt 20 Charcoal Metallic 94 Blue Metallic Reduced 2- Type It 400 F~SMV .... Pulse-Start 59 -. Dark Green Vertical Burn 3 .. Type Itl 750 Metal Halide 21 - Tomato Red GF~ .... FP Perimeter 1000 400, 750, 10002watt 55 Black Arm Forward Throw MHR - Metal Halide 50 White Mount FA- Automotive Reduced Envelope 51. Dark Red 5 - Type V 1000 Watt 700 - Aztec Silver Metallic GFPR ... PoleTgpll EXAMPLE OF A TYPICAL ORDER GFR 5 1000 MHR F MT BRZ 8BK 1- When ordering pole top fixtures for tenon mounting, a pole top adaptor must be ordered. 2- Tri-Tap not available in 1000 Watt PSMV. Voltage must be specified- 120V, 277V or 347V, 3- For international voltages, consult factory. 4- MT - Multi Tap is shipped standard unless otherwise specified. Multi Tap consists of 120V, 208V, 240V, and 277V. Multi Tap is pre-wired for highest voltage. Alternate voltages will require field re-wiring. 5- Tri-Tap is shipped standard fo~' Canadian applications. Tri-Tap consists of 120V, 277V. and 347V, Tri-Tap is pre-wired for highest voltage. Alternate voltages will require field re-wirin.q. 6- An 8" bracket can only be ordered with single and D180' configurations. 7- On OFR/GFPR photoelectric control can only be used with 400 Watt PSMV. , , , ACCESSORY ORDERING INFORMATION (Accessories are field installed) Description Order Number RPP2 Rouncl Pole Plate 162914BLK+ BKS-BO-WM-*-CLR Wall Mount Plate 123111CLR GFR/GFM 2 HSS ~ House Side Shield 4342901+ GFPR/GFPM 2 HSS --- House Side Shield 4342901+ GFR/GFM 3 HSS House Side Shield 4342902+ GFPR/GFPM 3 HSS Hou:,:e Side Shield 4342902+ GFR/GFM FP HSS - House Side Shield 4342902: GFPPJGFPM FP HSS House Sictc Shiotd 4342902+ Description Order Number FK120V - Single Fusing FK120V++ FK 277V Single Fusing FK277V++ DFK208, 240V --- Double Fusing DFK208, 240V** DFK480V - Double Fusin.q DFK240V++ FK347V Single Fusing FK347V++ +Black only. :+Fusin.q must be located in the hand-hole of the pole on GFR/GFPR Series 750 and 1000 Watt - riot in the ~1 i ©2003 LSI Industries Inc. 8/1/03 STEEL SQUARE POLES SQN - 2-3/8" O.D. x 4-3/4" Tenon SQBO - Bolt-On Mount, 2-Bolt Pattern SQP - Square Pole Top 14'-39' SQl- No Mounting Holes SF- Single Flood Pole Preparation Optional Base Cover Projection (4) Anchor Bolts Foundation By Other STEEL SQUARE POLES Steel Square Poles from LS! Lighting Systems offer durable aesthetics to enhance your specified lighting design. For a look that lasts, specify LSI. poles. SPECIFICATIONS POLE SHAFT Pole shaft is electro-welded ASTM-AS00 Grade C steel tubing with a minimum yield strength of 50,000 psi. On Tenon Mount steel poles, tenon is 2-3/8" O.D. high-strength pipe. 1-enon is 4- 3/4" in length. Straight poles are 4", 5", and 6" square. HAND-HOLE Standard hand-hole location is 12" above pole base. Hand-hole size is 2"x 4". Poles 22' and above have a 3"x 6" reinforced hand-hole. BASE Pole base is ASTM-A36 hot-rolled steel plate with a minimum yield strength of 36,000 psi. Two-piece square base cover is optional. ANCHOR BOLTS Poles are furnished with anchor bolts featuring zinc-plated double rluts and washers. Galvanized anchor bolts are optional. Anchor bolts conform to ASTM-A36 with a minimum yield strength of 36,000 psi. GROUND LUG Ground lug is standard. DUPLEX RECEPTACLE Weatherproof duplex receptacle is optional. GROUND FAULT CIRCUIT INTERRUPTER Ground fault circuit interrupter is optional. FINISHES Each pole is finished with LSI's DuraGrip~' baked-on polyester- powder finishing process to give the pole an exceptionally attractive appearance. The process electrostaticaily applies and STEEL SQUARE POLES thermally fuses a polyester powder POLE SELECTION CHART (4", 5" and 6" steel square poles) to the pole. This unique protection Height EPA ~ Outside Material Bolt 70 MPH 80 MPH 90 MPH 100 MPH Dimensions Circle 14' 23.3 16.7 12,2 9.0 4" S11G B 16' 18.6 13.1 9.3 6.5 4" S11G B 16' 34.6 25.0 18.5 13.8 5" SI'IG C 18' 14.4 9.'1 6.5 4,2 4' SllG B 18' 27.9 lcj.7 14.1 10,1 5" S11G C 20' 11.O 7.0 4.2 2.2 4' SllG B 20' 18.7 12.8 8.8 5.9 4" S07G B 20' 22.5 15.4 10.5 7.0 5" SllG C 20' 35.5 2.5.4 18,4 13.4 5" S07G D 22' 10.4 6.3 3,4 1.4 4" S11G B 22' 18.7 12.6 8,4 5.4 4" S07G B 22' 20.8 13,8 8.9 5.5 5" S11G C 22' 34.0 23.9 17.0 12.0 5" S07G D 24' 7,7 4.0 1,5 -- 4" S11G B 24' 15.1 9.7 6.0 3.3 4" S07G B 24' 16. '1 '10.5 6.2 3.1 5" S'1 '1 G C 24' 22.5 t4.9 9.7 5.9 5" S11H' D 24' 28.6 19.6 13.4 8.9 5' S07G D 24' 46.2 32.6 23.2 16.6 6" S07G J 26' 5.3 2,1 -- -- 4" S11G B 26' 12,0 7.2 3.9 1.5 4" S07G B 26' 13.2 7.6 3.8 1.0 5" S11G C 26' 24.0 15.8 10.3 6,3 5" S07G D 26' 39.6 27.3 18.9 12.9 6' S07G J 28' 19.9 12.5 7.5 3.9 5" S07G D 28: 33.9 22.7 15.1 9.6 6" S07G J 30' 16.3 9.6 5.0 1.7 5" S07G D 30' 28.8 18.6 11.6 6.6 6" S07G J 35' 18,3 10.0 4,3 w 6" S07G J 39' 11.5 4.3 -- m 6' S07G J process provides ail extremely smooth and uniform finish which withstands extreme weather changes without cracking or peeling. DuraGrip finish features a two-year limited warranty. Standard finish colors available for poles are bronze, black, platinum plus, buff, white, and green. Optional DuraGrip"' Plus features added protection with a 3.0 to 5.0 mil thickness of polyester-powder finish plus an inner coating. This specially developed inner coating is a thermal plastic hydrocarbon resin applied to the inside of the pole to seal and protect against atmospheric and corrosive matter. DuraGrip Plus finish features a five-year limited warranty. Refer to EPA data on next page for complete EPA information. '"H" denotes high yield steel (70,000 psi). If luminaire total weigl~t exceeds 250 pounds, consult factory. Follow these steps to determine the luminaire/pole combination for your application. · Select luminaire froFn Luminaire · Refer to Luminaire EPA Chart· Select MPH to match tile wind speed in Ordering Information to determine EPA value, the application area. · Select bracket configuration. · Select Height of pole. · Confirm the pole EPA that is equal to or exceeds the iuminaire/bracket EPA as was previously determined. ©2003 LSI Industries Inc. 811/03 ' ' g Systems"' 10000 Alliance Road · Cincinnati, Ohio 45242 · (513)793-3200 FAX (513)793-0147 · www,lsi-industries.com n~ Sys terns TM BOLT CIRCLE STEEL SQUARE POLES 4" square 5" square 5" square 6" square ~10-1/8" sq.1 ~-10-1/8" sq.i i_10.118,, sq.1 J----12" sq."--"1 ./"/' j/ ' / / 11" Bolt Circle // 11" Bolt Circle / ' 11" Bolt Circle " - ",,. ./ "xx,y/~ "%¥ 12" Bolt '~'?/B · D J Slotted Slotted Slotted Bolt Circle 8" to 11" 9" to 11" 9" to 11" Anchor Bolt Size 3/4~ x 30" 314" x 30" 1" x 36" l"x Anchor Bolt Projection 3-1/4" 3-114' 4" 4" Base Plate Opening for Wireway Entry 3-5/8" 4-3/4" 4-5/8" 5-5/8" Base Plate Dimensions 10-'1/8" sq. x 3/4" thk. 10-1/8" sq. x 3/4" thk. 10-'1/8" sq. x 1" thk. '12" sct. x '1 1/8" thk. Note: Base plate illustrations may change without notice. Do not use for setting anchor bolts. Consult factory for the base plate templates. ORDERING INFORMATION Select appropriate choice from each column to formulate order code. Refer to example below. Pole Series 2-Bolt Pattern 4SQBO 5SQBO 6SQBO Square Pole for Pole Top Mount 4SQP 5SQP 6SQP Square Pole for Tenon Mount 4SQN 5SQN 6SQN Square Pole (No mounting holes No pole top caps) 4SQl 5SQl Material S11G - 11 Ga. Steel S07G - 7 Ga. Steel S11H - 1 '1 Ga. Steel Consult pole selection chart on opposite page. Height '14' 16' 18' 20' 22' 24' 26' 28' 30' 35' 39' Consult pole selection chart on opposite page. 1 ii EXAMPLE OF A TYPICAL ORDER 1- See Area Lighting Brackets Section. 2- See Flood Lighting Brackets Section. 5SQBO ACCESSORY ORDERING INFORMATION (Accessories are field installed) Description Order Number 4BC - 4" Square Base Cover 122559CLR 5BC - 5" Square Base Cover 122561CLR 6BC - 6" Square Base Cover 122563CLR E R2 - Weatherproof Duplex Receptacle 122566PLT GFI - Ground Fault Circuit Interrupter' 122567PLT MHP- Mounting Hole PhJgs (3 plugs standard) 132336 Vibration Damper- 4" Square Pole 172539 Vibration Damper - 5" Square Pole 172538 Mounting Configuration Pole Finish S - SinglelParallel D180' - Double Dg0' - Double DNg0' - Double T90' - Triple TN120' - Triple 090' - Ouad ONg0' - Quad PT - Pole Top Mount BRZ- Bronze BLK - Black PLP -- Platinum Plus BUF - Buff Writ - White GRN - Oreen N - Tenon Mount (Standard tenon size is 2" pipe) I - For use with internal j Slip fitter l I i i i i ii _ i i ii ii 1 S07G 24 D180 PLP ,, DRILLING LOCATIONS J Options GA - Galvanized Anchor Bolts SF- Single Floodz DF - Double Flood2 DGP- Dur'aGrip~' Plus LAB - Less Anchor Bolts Standard SF and DF pole preparations are located 3/4 of the height of the pole from the base, unless otherwise specified, DGP Side i r/ V4 ~ Side i! --Side "O" , "B" Ik\ ~ Iii Side "A" (Hand-hole Side) Sides A B C D Hand-hole X Sin§le,,, X ................ · D180' X X D90' X X ,, T90' X X X · , , TN120" X ~9o, x x x x Single FBO X Double FBO X X 'Other two locations will be 120' to the left and right of' Side A. Note: Consult factory for custom variations. Standard SF and DF pole preparations are located 3/4 of the height of the pole front tire base, unless otherwise specified. All LSI Lighting Systems' poles are guaranteed to meet the EPA requirements listed. LSI Lighting Systems is not responsible if a pole order has a lower EPA rating than the indicated wind-loading zone where the pole will be located. Caution' This guarantee does not apply if the pole/bracket/ fixture combination is used to suppo~ any other items such as flags, pennants, or signs, which would add stress to the pole. LSI Lighting Systems cannot accept responsibility for harm or damage caused in these situations. Note: Pole calculations include a 1.3 gust factor over steady wind velocity. Example: poles designed to withstand 80 MPH steady wind will withstand gusts to 104 MPH. EPAs are for locations 100 miles away from hurricane ocean lines. Consult LSI for other areas. Note' Hurricane ocean lines are the Atlantic and Gulf of Mexico coastal areas. For Florida applications - consult factory. , ............................................................... _ ........ ©2003 LSI Industries Inc. 8/1/03