Loading...
HomeMy WebLinkAboutApplication DP DEVELOPMENTAL PLAN- APPLICATION Fee' $500.00 plus $25.00 per acre DATE: Preliminary Final Amended or Changed Name of Project: Mike's Express Car Wash Project Address: 1250 South Rangeline Road, Carmel, IN 46032 Legal Description: (To be typewritten on separate sheet and attached) See Exhibit "A" Name of Applicant' Mike's Car Wash, Inc. Address' 11711 North College Avenue, Carmel, IN 46032 Contact Person' Bill Dahm Telephone' (317) 580-8875 Name of Landowner: Gary R. Major Carmel Car Wash, Inc. and Richard E. and Catherine L. Major and Telephone' Address: 1250 South Rangeline Road, Carmel, IN 46032 Name of Engineer/Architect: Paul I. Cripe, c/o Gary_ Murray and Todd Bauer Telephone: 842-6777 Fax' 841-4798 Name of Attorney: Charles D. Frankenberger, Nelson & Frankenberger, 3105 E. 98th Street, Suite 170, Indianapolis, IN 46280 Telephone: 844-0106 Fax' 846-8782 Plot Size: + 2.13 acres, more or less (See Exhibit A legal description) Parcel Numbers: 16-09-36-04-02-006.000 and 16-09-36-04-02-004.000 Zoning Classification: I-1 Industrial District Present Use of Property: Car Wash- Automated and Self-Serve Car Wash Proposed Use of Property: Car Wash- Automated and Self-Serve Car Wash NOTE' this application must be filed in duplicate and accompanied by: (a) two (2) copies of the development plan which the applicant will be responsible for distribution among TAC members; (b) all necessary supporting materials. INC. · Pr~sid~t EXHIBIT "A" Part of the Southeast Quarter of Section 36, Township 18 North, Range 3 East in Hamilton County, Indiana described as follows: Commencing at the Northeast corner of the Southeast Quarter of Section 36, Township 18 North, Range 3 East in Hamilton County, Indiana; thence South 00 degrees 00 minutes 00 seconds West (assumed bearing) on the East line of said Southeast Quarter 938.15 feet to the South right-of-way of Carmel Drive; thence South 90 degrees 00'minutes 00 seconds West on said South right-of-way line 235.00 feet to the Northeast corner of the real estate described as Parcel II in Deed Book 248, Page 87 recorded in the Office of the Recorder of Hamilton County, Indiana, said point also being the point of beginning of the tract herein described; thence continuing South 90 degrees 00 minutes 00 seconds West on the North line of said real estate 165.05 feet to the centerline of the old Traction Company right-of-way; thence South 00 de~rees 45 minutes 10 seconds West on said center line 366.30 feet to the Northwest corner of the real estate described in Instrument #8702632 recorded in said Office; thence South 89 degrees 41 minutes 58 seconds East (this and the following 2 courses are on the North line of said real estate) 184.86 feet; thence North 00 degrees 00 minutes 00 seconds East 36.10 feet; thence South 89 degrees 41 minutes 58 seconds East 220.00 feet to the Northeast corner of said real estate, said point being on the East line of said Southeast Quarter Section; thence North 00 degrees 00 minutes 00 seconds East on said East line 132.30 feet to the Northeast corner of the real estate described as Parcel I in said Deed Book 248, Page 87; thence South 90 degrees 00 minutes 00 seconds West on the North line of said real estate 235.00 feet to the Southeast corner of the real estate described as Parcel I in said Deed Book 248, Page 87; thence North 00 degrees 00 minutes 00 seconds East on the East line of said real estate 200.00 feet to the point of beginning, containing 2.13 acres, more or less. subject to the right-of-way for Carmel Drive. Subject to the right-of-way for Range Line Road. C~lrme~ Mik~' ~ ~ide CarmsI Dr. Scale: "' 5'-1" ~:an~line Rd, On Carmel Dr. Mike'~ Enter ~igr~ 2.88~ Menu ~ign~20.75~ On ~it~ Book ~ign=25.84~ j< 2" 6" >j i< < 10' 2 V2' )J Based on the information provided oll dimensions and luminoire locations shown represent recommended po;~itions. The engineer ond/.or architect must determine applicability of the la3~)ut to existing or future field conditions. h tern re res ,r).J[S illumination levels colc;ulotcd ,from,.Ioborotor¥ Cato . This Ii ti o p 'hi um~noun r.q ~rleenn boc,ety ~ n rolle con~t~o s m accordance wit III q q' § " to token (~ ~:~ o fcurer s '[u ,d Ir mo roue o r ve~ me[~o S. ~c ol e[r~ monce of o ..... o ~3(~ion in ~tecOr,col c~t(og~, t~(~ronc' in lomas, ond ~ct~ ....... ~e %¥d co)~dm~m~:~s. · · C;-':. ~'~;L '"':"';~; o.o o.o o.o o.o n~ ~ o.1 O3 O.l 0.0 0,1 0.1 13,1 0.1 0.1 o.o : 0.1 0.1 O.o ~0 ~0 o.o la, ~.o 0 ~ '. ~ ~, · ~L- - ~ ~ + { -~-~ ~ .............. ~ .................... ~:F' ,' ~ o' , '~' · : ~1 ~ /J'~ ? 'x ~ '~ /m I , : ~ : . ~ ~ / ~ ~ ~, / .~ / ~ ' ~ ~" ;! I~ ~'"~:''< ~ il ~ 01 ' · 'l ~J ~ ~.~ 7.81 /' ;' / % / ~' ~':1 L 7.~: ,~;~7 ~.8~ s.m ,~, z~ · ' ~r + ' ~ '. m : : , : :: ~ DL-~-HSS ~ ~-~-HSS ) ~'"~' e ) . , ~ , ~ ~ . r ~ ~ ~-. [ ...... ~,, ~,~l~.,~p_~:,,~ ,., ,~, ,,.,~.,~ ,,.o ' ' ~:..~....~.~..i ................................. : .......................... ~ :~ ~. [ ...... ~-~ ~s 1.2 ~1 '01:~ iG~.] 43 ~.3 :t2.0 7.414.L~ ~ ~ 52 J o.o ~ ~,~ ~,.,~t .... ~ 'q ~' I I ' · ~'-'H .... ~ ..... ,-~ ....... %~:;' ' ~-'' ~ ..................... ~ ~ ~'~'Jo o o iooo ~:~' '?~ , -~ :"~ ~" "' - ....................................... i .... ~e: ......... ;o .......... 6 ..... ~" ~ o5 o o .......... ; .... ~."~* ,~ ~.* i ...... ~ '~ .' 2' ~ ":-~ ~ '~--~--~ ................... ~, ~ ' - - ' .... -- ~" ~1 ~ Z2 2.e ~J 0.7 ~ O~ . ~ ~:: ~ · ' e.O t ~ 0.0o.~ o. 3 ' ~.u~ ....~ ~o o.o o !~o ~ ~o ~o ~o ~,~~~~~ · ~. "-.-. o.o i o.oi . o.o ASSEMBLY PO..~LE ~~- BRACKE,~T ~ OTHER ASSEMBLIES EACH CONSISTING OF': BILL OF MATERIALS Revisions Revision Notes New Site Plans GREENBRIAR FLAT LENS SITE LIGHTING NOTES' 1. ALL LIGHT LEVELS ARE MAINTAINED WI iH A .80 UGHT LOSS "FACTOR, AND CALCULATED AT GRADE. 2. ALL LIGHT FIXTURES HAVE: A FLAT LENS, AND ARE CLASSIFIED AS A FULL CUT-OFF LIGHT FIXTURES. 3. ALL POLES ARE 18' TALL MOUNTED ON BASES WHICH EXTEND 2' A.F.G. OFR-FP- 1000-MHI GFR- FP- 1000- M FtXTURE 1 O8O ,855 KOPETSKY DRIVE SUITE INDIANAPOLIS IN 46217 MIKES CARWASH CARMEL INDIANA SCALE' 1"-.30' 12.10.05 BY: w.C.P. C201 00~407-20000 6'0 No pa':t of ~i~ drawing, design, or document may be used by any i~du~l ~ entily wilt,out ltm oxpres~ wri,'ten I~t~i$sio~ Of tho CQl~/~iliht owner. I~) part Q! this clrawir, g, de.h, o~ do~lmm~t may be mproduceck st~red in a retrieval ly&tem or ~ar~oi~led in any fo,m or by. am .rn~.all~,, e{ecP'onio, mec, hanic~., p!'x)toc~yir, g, C~{d~g, or c)the~viso, ~vi~.out Ute express written : GREENBRIA,R FLAT LENS Fixtures with flat lens meet IESNA full cut-off classification. LISTED listed for wet locations. ©2003 LSI Industries Inc. 8/1/03 Various reflectors are protected by U.S. Patents No. 6,464,378. LSI's Greenbriar Flat Lens Series uniquely combines the high performance and benefits of traditional vertical burn technology, with the full cut-off distribution afforded by a flat. lens. Specially designed reflectors provide uniform, high perrormance lighting while the flat glass lens ensures the full cut-off distribution as defined by IESNA, thus meets stricter zoning requirements, Designed around a reduced envelope lamp, the compact, top-access fixture is easy to install and service. SPECIFICATIONS HOUSING The aluminum housing is available in two sizes: Greenbriar Flat Lens Reduced Envelope 1000 Watt lamp and Greenbriar Flat Lens Reduced Envelope 400 Watt lamp. Both housings are the same dimensions square, however, the GFR is deeper. Both are finished to produce a clean, sharp appearance, and designed to ensure weather-tight construction. Top-access covers provide ease of installation and servicing. LENS/GASKET The flat clear tempered glass lens is sealed to the housing with an EPDM gasket, preventing entry of moisture, dust and insects. REFLECTORS/DISTRIBUTION BALLAST PATTERNS Metal Halide and High Pressure The series is available in a variety of Sodium fixtures feature a High- power factor type CWA ballast. reflector systems and distribution patterns, all with vertical oriented lamps: GFR: Type Ii (2),Type I!1 (3), Perimeter Forward Throw (FP), Type V (5) and Automotive Forward Throw (FA). GFM: Type il (2), Type III (3), Perimeter Forward Throw (FP), and Type V (5). Field-rotatable reflectors provide flexibility in distribution patterns without moving the fixture. Photometric data is tested in accordance with IESNA guidelines. FINISHES Each fixture is finished with LSI's DuraGrip® polyester powder coat TOP FASTENERS The four captive stainless steel door fasteners secure the top-access finishing process. The DuraGrip finish withstands extreme weather cover to the housing, changes without cracking or SOCKETS Porcelain mogul-base sockets. All sockets are pulse-rated. LIGHT SOURCES Pulse-Start Metal Halide, Metal Halide, Metal Halide Reduced Envelope, or High Pressure Sodium. Clear lamp is supplied as standard. peeling, and is guaranteed for five full years. Standard colors include bronze, black, platinurn plus, buff, white and green. DECAL STRIPING LSI offers optional color- coordinated decals in 9 standard colors to accent the fixture. Decal is guaranteed for five years against peeling, cracking, or fading. All ballast types are designed rot -20'F operation. BRACKETS Arm Mount: 2-1/2" x 5-3/8" x 12" extruded aluminum bracket is shipped standard. An 8" bracket is available for single or D180" configurations, but must be ordered from the Options column of the ordering chart. A Round Pole Plate (RPP2) is required for mounting to 3"-5" round poles. (See Accessories chart.) Pole Top: The cast aluminum mounting hub conceals the wiring. compartment and mounts directly to LSI's unique "pole-top mounting plate", via a high-strength grade five steel bolt with nylon insert and split lock washer for double locking. Support arms consist of four '11/'i 6" O.D. aluminum rods and are pre- wired for ease of installation. POLES Refer to Poles/Brackets section of catalog for pole information. PHOTOMETRICS For detailed photometric data, please visit our website at www,lsi-industries.com · . g SystemsTM 10000 Alliance Road · Cincinnati, Ohio 45242 · ~513)793-3200 FAX (513)793-0147 · www.lsi-industrie~.com DIMENSIONS Bracket - Lq: Z-bolt Arm Mount Pattern Pole Top Mount A B C GFMAr'm'Mount .. 21'5'"8" I 12:3/4; '- GFPM Pole TOp 21-5i8" 12-3!4" 21-15/16" GFR Arm Mount 2'1-5i8" 16-'118" GFPE Pole Top 21-5!8" 16-118'; 25"' .... ,, LUMINAIRE EPA CHART Pole Top Mount Single DgO' D180' T90' TN120' Q90' ~reenbriar Flat 12" Arm Mount Bracket (GFM) -- 3.2 5:7 ,6.,3 8.8. , 9.0 I 1.3 Greenbriar Flat - Pole Top (.GFPM) 3.2 Greenbriar Flat. 12'; Arm MoLJnt Bra(:ket. (GFR) .... 3.8 7.6 '".7:6 11.4 l 1.4 15.2 Greenbriar Flat - Pole Top (GFPR) 4.0 LUMINAIRE ORDERING INFORMATION Select appropriate choice from each column to formulate order code, Refer to example below, ...... 1 Luminaire Lamp Line Luminaire Options Prefix Distribution Wattage Light Source Lens Volta.qe3 Finish M~dium 2 Type Ii 250 PSMV Pulse-Start Metal F Flat Clear 480V BRZ Bronze 8BK - 8" Bracket~ Vertical Burn 3 - Type Itl 320 Halide 250, 320 Watt Tempered MT Multi Tap4 BLK .- Black PCI120V.. Button-Type Photoelectric Control;' GFM - FP Perimeler 400 SMVR ... Super Metal Halide Glass TT - Tri-Taps PLP - Platinum Plus PCI208V Button-Type Photoelectric Control7 Arm Forward Throw Reduced Envelope 400 Watt BUF ..~ Buff PCI240V Button-Type Photoelectric Control7 Mount 5 Type V MH Metal Halide WriT- White PCI277V Button-Type Photoelectric Control7 250 Watt GRN Green LL - Less Lamp GFPM .- MHR-. Metal Halide Reduced Pole Top~ Envelope 400 Watt Color Decals HPS -.. High Pressure Sodium 45 - L. ighl Gold Metallic 250, 400 Watt 20 Charcoal Metallic ,,, Reduced 2- Type 11 400 PSMV Pulse-Start 94 Blue Metallic 59 Dark Green Vertical Burn 3 -. Type Itl 750 Metal Halide 21 - Tomato Red GFR .... FP Perimeter '1000 400, 750, 10002watt 55 Black Arm Forward Throw MHR - Metal Halide 50 White Mount FA- Automotive Reduced Envelope 51 Dark Red 5 .. Type V 1000 Watt 700 - Aztec Silver Metallic GFPR .- Pole Tq,p'~ ,, EXAMPLE OF A TYPICAL ORDER I IGFR 5 1000 MHR F MT BRZ 8BK ii 1- When ordering pole top fixtures for tenon mounting, a pole top adaptor must be ordered. 2- Tri-Tap not available in 1000 Watt PSMV. Voltage must be specified- 120V, 277V or 347V, 3- For international voltages, consult factory. 4- MT - Multi Tap is shipped standard unless otherwise specified. Multi Tap consists of 120V, 208V, 240V, and 277V. Multi Tap is pre-wired for highest voltage. Alternate voltages will require field re-wiring. 5- Tri-Tap is shipped standard for Canadian applications. Tri-Tap consists of 120V, 277V. and 347V. Tri-Tap is pre-wired for highest voltage. Alternate voltages will require field re-wirin.q. 6- An 8" bracket can only be ordered with single and D180' configurations. 7- On GFR/GFPR photoelectric control can only be used with 400 Watt PSMV. ,, , ACCESSORY ORDERING INFORMATION (Accessories are field installed) Description Order Number RPP2 Round Pole Plate 162914BLK+ BKS-BO-WM- *'-CLR Wall Mount Plat~ 123111CLR GFR/GFM 2 HSS - House Side Shield 4:342901+ GFPR/GFPM 2 HSS-- House Side Shield 4342901+ GFR/GFM 3 HSS Hous~ Side Shield 4342902+ GFPR/GFPM 3 HSS House Side SI]ield 4342902: GFRIGFM FP HSS- House Side Shielcl 4342902+ GFPR.;GFPM FP HSS House Side Shield 4342902* Description Order Number FK120V Single Fusing FK120V++ FK 277V Single Fusing FK277V+* DFK208, 240V-- Double Fusing DFK208, 240VH DFK480V - Double Fusin.q DFK240V++ FK347V Single Fusing FK347V++ *Black only. :*Fusin.q must be located in the hand-hole of the pole on GFR/GFPR Series 750 and 1000 Watt - not in the fixture,. ©2003 LSI Industries Inc. 8/1/03 STEEL SQUARE POLES SQN - 2-3/8" O.D. x 4-3/4" Tenon -hol SQBO - Bolt-On Mount, 2-Bolt Pattern SQP - Square Pole Top 14'-39' SQl- No Mounting Holes SF- Single Flood Pole Preparation Optional Base Cover Projection (4) Anchor Bolts Foundation By Other Steel Square Poles from LSI Lighting Systems offer durable aesthetics to enhance your specified lighting design. For a look that lasts, specify LSI poles. SPECIF)CATmONS POLE SHAFT Pole shaft is electro-welded ASTM-AS00 Grade C steel tubing with a minimum yield strength of 50,000 psi. On Tenon Mount steel poles, tenon is 2-3/8" O.D. high-strength pipe. Tenon is 4- 3/4" in lengU]. Straight poles are 4", 5", and 6" square. HAND-HOLE Standard hand-hole location is 12" above pole base. Hand-hole size is 2"x 4". Poles 22' and above have a 3"x 6" reinforced hand-hole. BASE Pole base is ASTM-A36 hot-rolled steel plate with a minimunq yield strength of 36,000 psi. Two-piece square base cover is optional. ANCHOR BOLTS Poles are furnished with anchor bolts featuring zinc-plated double nuts and washers. Galvanized anchor bolts are optional. Anchor bolts conform to ASTM-A36 with a minimum yield strength of 36,000 psi. GROUND LUG Ground lug is standard. DUPLEX RECEPTACLE Weatherproof duplex receptacle is optional. GROUND FAULT CIRCUIT INTERRUPTER Ground fault circuit interrupter is optional. FINISHES Each pole is finished with [..51's DuraGrip~' baked-on polyester- powder finishing process to give the pole an exceptionally attractive appearance. The process electrostatically applies and STEEL SQUARE POLES thermally fuses a polyester powder POLE SELECTION CHART (4", 5" and 6" steel square poles) to the pole. This unique protection Height EPA ~' Outside Material Bolt 70 MPH 80 MPH 90 MPH 100 MPH Dimensions Circle 14' 23.3 16.7 12,2 9.0 4" S'llG B 16' 18.6 !3.1 9.3 6.5 4" SllG B 16' 34.6 25.0 18.5 13.8 5" SI'IG C 18' 14,4 9.'7 6.5 4.2 4" SllG B 18' 27,9 19.7 14.1 10.1 5" SllG C 20' 1 t.O 7.0 4.2 2.2 4" S11G B 20' 18.7 ! 2.8 8.8 5.9 4" S07G B 20' 22.5 15.4 10.5 7.0 5" SllG C 20' 35,5 2.5.4 18.4 13.4 5" S07G D 22' 10.4 6.3 3.4 1.4 4" SllG B 22' 18.7 12.6 8.4 5.4 4" S07G B 22' 20.8 13.8 8.9 5.5 5" S1 'l G C 22' 34.0 23.9 17.0 12.0 5" S07G D 24' 7,7 4.0 1,5 -- 4' SllG B 24' 15.1 9.7 6.0 3.3 4" S07G B 24' 16.'1 '10.5 6.2 3,1 5" SllG C 24' 22.5 14.9 9.7 5.9 5" SllH* D 24' 28.6 19.6 13,4 B.9 5" S07G D 24' 46.2 32.6 23.2 16.6 6' S07G J 26' 5.3 2.1 w _ 4" SllG B 26' 12,0 7.2 3.9 1.5 4" S07G B 26' 13.2 7.6 3.8 1.0 5' S11G C 26' 24.0 1,5.8 10.3 6.3 5" S07G D 26' 39.6 27.3 18.9 12.9 6" S07G J 28' 19.9 12.5 7.5 3.9 5" S07G D 28' 33.9 22.7 15.1 9.6 6" S07G J 30' 16.3 9.6 5.0 1.7 5' S07G D 30' 28.8 18.6 11.6 6.6 6" S07G J 35' 18.3 10.0 4.3 -- 6" S07G J 39' 11.5 4.3 -- -- 6' S07G i J process provides an extremely smooth and uniform finish which withstands extreme weather changes without cracking or peeling. DuraGrip finish features a two-year limited warranty. Standard finish colors available for poles are bronze, black, platinum plus, buff, white, and green. Optional DuraGrip'"' Plus features added protection with a 3.0 to 5.0 mil thickness of polyester-powder finish plus an inner coating. This specially developed inner coating is a thermal plastic hydrocarbon resin applied to the inside of the pole to seal and protect against atmospheric and corrosive matter. DuraGrip Plus finish features a five-year limited warranty. Refer to EPA data on next page for complete EPA information. *"H" denotes high yield steel (70,000 psi). If luminaire total weight exceeds 250 pounds, consult factory. Follow these steps to determine the iuminaire/pole combination for your application. · Select luminaire from Luminaire · Refer to Luminaire EPA Chart · Select MPH to match the wind speed in Ordering Information. to determine EPA value, the application area. · Select bracket configuration. · Select Height of pole. · Confirm the pole EPA that is equal to or exceeds the luminaire/bracket EPA as was previously determined. ©2003 LSI Industries Inc. 8/1/03 ~111~ Sys terns '" 10000 Alliance Road · Cincinnati, Ohio 45242 · (513)79,]-]200 FAX (513)793-0'147 · www.lsi-industries.com BOLT CIRCLE 4" square 5" square 5" square 6" square .'.F10-1/8" sq.1 [-10-1/8" sq.i ~-~o-ur '~q'l ~-~z" sq.--~ . 11" Bolt Circle ~' 11" Bolt CirCe /1 11" Bolt '% / % .. ~ / ". ./ ~z" ~o, circe ~ ¥/J ~"/B" Y C ;~ D Slotted Slotted Slotted Bolt Circle 8'" to 11" 9" to 11" 9" to '11" Anchor Bolt Size 3/4' x 30" 3/4" x 30" l"x 36" Anchor Bolt Projection 3-1/4" 3-1/4" 4' 4" Base Plate Opening for Wireway Entry 3-518" 4-3/4" 4-5~8" 5-5/8" Base Plate Dimensions '10-'1/8" sq. x 3/4" thk. 10-1/8" sq. x 3/4" thk. 10-1/8" sq. x 1" thk. 12" sq. x '1 '1/8" thk. Note: Base plate ilhJstrations may change without notice. Do not use for setting anchor bolts. Consult factory for the base plate templates. iiii iiiii ii iiii i iiiiii i ii i i i ii ORDERING INFORMATION Select appropriate choice from each column to formulate order code. Refer to example below. Pole Material Height Mounting Pole Finish Options Series I Configuration 2-Bolt Pattern S11G - '11 Ga. Steel j 14' j S - Single/Parallel j BRZ - Bronze GA - Galvanized Anchor Bolts 4SQBO S07G - 7 Ga. Steel J 16' D180' - Double i BLK - Black SF - Single Floodz 5SQBO S11H - 1'1 Ga. Steel i 18'J D90' - Double i PLP -. Platinum Plus DF - Double Flood2 6SQBOJ 20' i DN90' - Double ! BUF - Buff DGP - DuraGrip+ Plus Consult pole selection j 22' T90' - Triple i WriT - White LAB - Less Anchor Bolts chart on opposite page. j 24'26, ii QB0'TN120'_ Quad- Triple I GAN - Green j 28' t QNgO' -Quad . 30' , PT - Pole Top Mount Square Pole for J 35' Pole Top Mount 4SQP j 39' 6SQP ! Square Pole for ! N _ Tenon Mount Tenon Mount , (Standard tenon 4SQN i size is 2" pipe) Consult pole selection i Standard SF and DF pole preparations 6SQN J chart on opposite page. j Square Pole I - For Use with internal i from the base, unless otherwise specified. (No mounting holes Slip fitter~ No pole top caps) 4SQl J 5SQl i i i i i i i i ~ i i i i I iii iiiiiiii ii i i J ii iii ii i i i, i ,I ii EXAMPLE OF A TYPICAL ORDER 1- See Area Lighting Brackets Section. 2- See Flood Lighting Brackets Section. J SSQBO S07G 24 D180 PLP SF DGP ......... I ACCESSORY ORDERING INFORMATION (Accessories are field installed) Description Order Number 4BC - 4" Square Base Cover 122559CLR 5BC - 5" Square Base Cover 122561CLR 6BC - 6" Square Base Cover 122563CLR ER2 - Weatherproof Duplex Receptacle 122566PLT GFI - Ground Fault Circuit Interrupter 122567PLT MHP - Mounting Hole Plugs (3 plugs standard) 132336 Vibration Damper- 4" Square Pole 172539 Vibration Damper- 5" Square Pole 172538 DRILLING LOCATIONS Side %,, "% Ii \\1[ Side ,,A,, (Hand-ho{e Side) Sides A B C D _ Hand:h°le X Single X D180' X X Dg0' X X T90' X X X TN120" X ,, Q90' X X X X , ,, Single FB0 X Double FB0 X X *Other two locations wilt be 120' to the left and right of' Side A. Note: Consult factory for custorft variations. Standard SF and DF pole preparations are h)cated 3/4 of the height of tile pole from the base, unless ott]erwise specified. ii All LSI Lighting Systems' poles are gUaranteed to meet the EPA requirements listed. LSI Lighting Systems is not responsible if a pole order has a lower EPA rating than the indicated wind-loading zone where the pole will be located. Caution: This guarantee does not apply if the pole/bracket/ fixture combination is used to support any other items such as flags, pennants, or signs, which would add stress to the pole. LSI Lighting Systems cannot accept responsibility for harm or damage caused in these situations. Note: Pole calculations include a 1.3 gust factor over steady wind velocity. Example: poles designed to withstand 80 MPH steady wind will withstand gusts to 104 MPH. EPAs are for locations 100 miles away from hurricane ocean lines. Consult LSt for other areas. Note: Hurricane ocean lines are the Atlantic and Gulf of Mexico coastal areas. For Florida _applications - consult fagtory_. , ........................................................... - .................... ©2003 LSI Industries Inc. 8/1/03