Loading...
HomeMy WebLinkAboutCorrespondenceOne Civic Square Carmel, IN ~ Fax'. (3~ 7) 57~-2426 CC; l-I Urgent /~rReview 1-1 Please Comment Please Reply Please Recycle ~-0 r J · ... C ty. of Carmel VIA FAX: (317) 849-59~ Original by mail 'September 10, 2004 Brian Robinson Stoeppelwerth and Associates 9940 Allisonville Rd. Fishers, IN 46038 REe The Townes at Weston Pointe, Section 1, Secondary Plat Dear Mr. Robinson: This letter is in response to your recently submitted Mylars of the Tomes at Weston Pointe, Section 1, Secondary Plat. The following issues must be addressed with this plat Mylar before it can be officially signed: 1. Source of title must be listed on page 1. 2. The title should read "secondary" plat, and not "conditional" plat. 3. An area map must be included on the plat. 4. A non-access easement should be identified along US 421 (Michigan Rd) north of the Weston Pointe Drive intersection. 5. Right-of-way distance needs to be called out at the US 421 (Michigan Rd)/Weston Pointe Drive intersection. 6. Monumentation needs to be shown along block boundaries, and at block and property comers (shown in red on the attached plans) Please submit a revised Secondary Plat with the above-mentioned changes. Once these changes have been made and comments addressed, please produce a Mylar copy for signature by this Department. Two paper copies of the plat must be filed with the Mylar prior to recording, and three paper copies and a Mylar of the recorded plat must be submitted following recording. Our approval of the secondary plat (signature) will be forthcoming upon revision of the plans according t the items listed above. If you have any questions or if I may be of assistance, please feel free to cai1. Matthew Griffin, AICP Planning Administrator Page 1 ONE CIVIC SQUARE CARMEL, INDIANA 46032 317/571-2417 FAX (317) 849-5942 DATE' February 13, 2004 JOB NUMBER: 37963PORS1 TO: Department of Community Services ATTENTION: 1 Civic Square Carmel, Indiana 46032 Jon Deboiewicz Weston Pointe, Section 1 WE ARE SENDING YOU [ X ] ups [ ] Courier [ ] Other: COPIES SHEET DESCRIPTION NO. 1 Set Revised Construction Plans 1 Secondary Plat THESE ARE TRANSMITTED as checked below: [ ] For Approval [ X ] As Requested [ ] For Review and Comment [ X ] For Your Use [ I If you have any questions, please feel free to call me at (317) 57%3400, ext. 16. Thank you, Brian K. Robinson Cc: Christine Pasquinelli HAMILTON COUNTY HIGHWA Y DEPARTA4ENT January 29, 2004 Mr. Brian Robinson Stoeppelwerth and Associates, Inc. ~940 AIIl$onville Road Fishers, Indiana 41~038~2005 RE: Clay Township 0d 0\ 0 and Construction Plans US 421 Dear Mr. Robinson' This letter serves to acknowledge receipt of a transmiffal received 1t20/04 containing the plans for the above-mentioned project. After reviewing the plans the Highway Department has the following c~mments: 1. OK. 2. Please note that decorative signs, sprinkler systems, trees, landscaping mounds, fences, light poles or other such amenities are not permitted in the right ~f way. The note should be shown on the plat and construction plans. 3. OK. 4. OK. 5. OK. 6. OK. 7. Triangular dght of way cuts am necessary at the entrance. The triangular cut must consist of two 50' legs. The hypotenuse of the triangle would be 70,7'1', 8. Show any instrument numbers associated with right of way acquisition along US 421. The number must also appear on the secondary plat, 9. OK. 10. Before any approvals are granted for the secondary plat, performance bonds must be submitted for 100% of the construction cost of the following Items; Stone Base, HAC Binder, HAC surface, Concrete Curbs and Street Name and Regulatory Signs. 11. OK. 12. Note the type of curb to be used. Chairback Curb with a reverse slope must be used around the medians in Weston Polnte Drive, Will chairback or roll curb be used throughout the rest of the development? Please note the type on the plan sheets. 13. Valley curb will be required across the entrances to the private streets. This will allow for distinction between the public and private streets as well as for a continuous sub surface drain. Insure that water wlll not pond at the intemectlons where the valley curb is to be used, It appears that the proper slope does not exist at several of the Intersections, 1700 South 10* Street Noblesville, In. 46060 Office (317) 773-7770 Fax (3] T) 7'/6-9814 14. Include all of the necessary HCHD Standard Details. C-1, C-5, P-l, U-2 and U-4. Remove the unapproved details shown on Sheet C802. All details for the street construction must be the approved Standard Plans with the Hamilton County slgnatur® block on them. Please Include all the neceasary details and remove the curb details that are not approved, 15. OK. 16. OK. Note that a white 4" line is to be used for the lane separation, 17. OK, 18. OK. 19. OK. 20. OK. 21, OK. 22. OK. 23. Please note that further comments will be necessary when revised construction plans are completed. 24, A signature block fo~ the Hamilton County Beard of Commissioners Is needed on the plat. If you have any questions or comments concerning this letter, please feel free to c=ntact me at anytime, Since .rely, 'Steven J, Bmermann Staff Engineer Jon Doboslewicz Greg Hoyes G:~IJ3 ERS~SBt,04tac~01-29-04wm-~ tonpolnte, doo Kenton C. Ward, Surveyor qPJ~'one ('jz7) 77~.8'4.95 Fax ('3~7.) 77~-9628 State r 8'8 One Hamilton County &luare :.Noblesville, /,diana 46o6o.2~3o January 20, 2004 Stoeppelwerth & Associatas, Inc. Attu: Brian Robinson 9940 Allisonvill¢ Road Fishers, IN 46038-2005 VIA FACSIMILE' 849-5942 Dear Mr. Robinson: We have reviewed the construction plans submitted to the Hamilton County Surveyor's Office on December 30, 2003 for this project and have the following comments'. 1 This project will be a Hamilton County Regulated Drain Subdivision, subject to approval of the Hamilton County Drainage Board. 2~ .The proposed project will be partially added to the Crooked Creek Watershed, which has a 0.25 els restriction rate. The original engineers report that set this rate included this proposed site into the watershed area, and must be restricted to the 0.25 els per acre rate. ! This proPosed project is not currently annexed into the City of Cannel; therefore, the plat will be approved by the Hamilton Cmmty Board on Commissioners. 1 Please show existing regulated drainage facilities for The Parks at Weston Place Section 2 & 3 and .The Villages at Weston Place Section 2. Please show the off-site regulated drain for The Parks Section 3, storm sewer running to the north. Also show all corresponding easements for regulated drains. 5~ Please provide us with proof of permission, from INDOT, to discharge storm water and encroachment into the ROW of U.S. 421 (Michigan Road). Also, provide design drawing that show where the proposed 421 storm pipe discharges and that it is sized properly for this site. 6~ The approved HCSO pond standards, D6, D7, or D8, require 2' of freeboard from the 100 year elevation. The standards also require 15' easement from TOB completely around the pond. This easement may overlap onto platted lots, but the TOB must be in platted common area, dedicated as drainage easement. Please correct the plat to show this requirement. 7. Show emergency spillway and overland routing for detention ponds, per HCSO approved pond standards, on the project. 8~ During a meeting in our office, it was agreed that all non-platted lot area would be common area and dedicated as drainage easement. This was also to be address in the covenants for the proposed development. This may be address with furore re- plats, but it will need to happen before the project is finished. 9. Please label Common Areas on site plan, and note they are also drainage easements. 10. Please remove the Carmel Storm Sewer Note from the construction plans, as the storm sewer are approved and will be inspected by HCSO. 11. Please label TOB on all ponds, which must be 2' above the 100 year pond elevation. 12. Please remove any generic storm sewer design standard and replace with the approved appropriate HCSO design standard. 1.3. Please include our approved. Storm Structure Date Table, standard D-19, on the site development plan. 14. Several storm structures have a TC or in.vert elevation (on end sections) set below the Q100 pond elevation, some even below the Q2 pond elevation. For example, storm nm 612 to 613 has a high end invert of 898.40, which will allow this nm to act as an outlet, not an inlet, during a 2. year storm event. This is not acceptable as flooding will be caused to lot 57 & 58 of the neighboring section of the Weston's. This will also occur with storm nm 608 to 611. 15. Please check ALL hydraulic grade lines to make sure no inlet will surcharge during a 100 year storm event. 16. Please prove that pipe mn 608 to 611 is properly sized to handle future possible use of land in Block A, whether it is commercial or residential. 17. Please label pond #3 and pool elevations on sheet C601 of the profiles. 18. Please label storm sewer pipe size, material, and slope on the site development plans. 19. Per the HCHD commem itl 3, with the installation of valley curb across the private street entrances, storm sewer curb inlets will be needed to capture the water in the curb line of the public street, 20. Please submit the following procedural items to this office, petition for regulated subdivision, utility crossing permit, engineer's estimate, and all associated bonds for 100% of construction cost. The applications are available on our website at www. co,hamilton,in_....us, go to Departments, Surveyor, and Documents for Download. 21. Please include developers fax number on the cover sheet. 22. Please note that fitnher comments may be necessary at a later date. Should you have any questions, I can be reached at 317-776~8495. Sincerely, Greg Hoyes Plan Reviewer Cci Jon Dobosiewicz- Carmel DOCD .lohn South- HCSWCD Steve Broermann- HCHD January 15, 2004 Brian Robinson Stoeppelwerth and Associates 9940 Allisonville Rd Fishers, IN 46038 RE Weston Pointe, Sec. 1 (04010003 SP) -Secondary Plat Application Dear Mr. Burke: VIA FAX: 849-5942 Original by'mail This letter is in response to your Secondary Plat Application for Weston Pointe, Sec. 1. This is a preliminary letter to let you begin on revisions. Additional comments will be made by members at the TAC Meeting on January 21. Please complete the following items after you have received additional comments at the TAC Meeting. 1, 2. 3. 4. 5. 6, 7. 8. 9. Please place docket numbers on plat: 137-03 PP and 04010003 SP. Please label latest submission date or revision. Please label the source of title number. Please add surveyor's signature and date on plat. Forward your correspondence with the following agencies: Carmel Engineering, Scott Brewer (Urban Forester), and John South (Soil and Water). Provide a copy of covenants, if any. ~ ~,,,f~ ~,$e, Minimum front yard is 35-ft in the R-4 zoh'~. A variance for setback may be required. through out the whole site, not just on Weston Pointe Blvd~,_,,,~~r'~ Please provide 5-ft sidewalks Please submit a landscape plan to us and to the Urban Forester...2 Please submit a revised Secondary Plat with the above-mentioned changes. Once these changes have been made and comments addressed, please produce a Mylar copy for signature by this Department. Two paper copies of the plat must be filed with the Mylar prior to recording, and three paper copies and a Mylar of the recorded plat must be submitted following recording. Our approval of the secondary plat (signature) will be forthcoming upon revision of the plans according to the items listed above. If you have any questions or if I may be of assistance, please feel free to call. Sincerely, Angelina Butler Planning Administrator WestonPointe,Sec 1-SP 1 Page 1 ONE CIVIC SQUARE CARMEL, INDIANA 46032 317/571-2417 Babbitt, Pamela A From: Sent: To: Cc: Subject: Butler, Angelina V Friday, January 09, 2004 12:37 PM Babbitt, Pamela A Morrissey, Phyllis G; Pattyn, Dawn E; Tingley, Connie S; Hollibaugh, Mike P; Keeling, Adrienne M; Kendall, Jeff A; Brewer, Scott I; Hancock, Ramona B; Dobosiewicz, Jon C; Stahl, Gayle H; Pohlman, Jesse M Docket No. Assignment: Weston Pointe Subdivision (#04010003 SP) Para, Please print and fax this e-mail to the petitioner identified below and update the file. I have issued the necessary Docket Number for (SP) Weston Pointe Subdivision. It will be the following' Docket No, O4Ol~O3' SP $728.00 ?0talF~:~.~ $728~00 Docket No. 040100003 SP: Weston Pointe Subdivision- Secondary Plat The applicant seeks approval to plat 23 blocks/130 Units. The site is generally located northeast of 106th Street and Michigan Rd. The site is zoned B-2/Business and R-4/Residential. Filed by Brian Robinson of Stoeppelwerth & Associates for Portrait Homes. Petitioner, please note the following: 1. This Item has been placed on the January 21 agenda of the Technical Advisory Committee. 2. Mailed and Published Public Notice does not need to occur. 3 ':'''~ ' ~ Pr00f 0fN0tice ~is 'not ~needed~. 4. The Filing Fee must be paid before signing of the plat by the Director. 5. This Item will be reviewed administratively. PETITIONER: refer to your instruction sheet for more detail. Please contact Mr. Robinson at 577-3400 x 16 (Fax' 849-5942) with this information. Once the file is updated please return it to Jon's office. Thank you, Angle City of Carmel Department of Community Services One Civic Square Carmel, IN 46032 317-571-2417 Fax: 317-571-2426 FACSIMILE TELECOPY COVER LETTER DATE: January 9, 2004 TO: Robinson FAX: 849-5942 FROM: Pam Attached hereto are 2 pages, including this cover letter, for facsimile transmission. Should you experience any problem in the receipt of these pages, please call 317/571/2417 and ask for Pam. NOTES' Docket Assignment Sheet. Please call if you have any questions. CONFIDENTIALITY NOTICE: The materials enclosed with this facsimile transmission are private and confidential and are the property of the sender. The information contained in the material is privileged and is intended only for the use of the individual(s) or entity(ies) named above. If you are not the intended recipient, be advised that any unauthorized disclosure, copying, distribution or the taking of any action in reliance on the contents of this telecopied information is strictly prohibited. If you have received this facsimile transmission in error, please immediately notify us by telephone to arrange for return of the forwarded documents to us. January 8, 2004 Mr. Brian K. Robinson Stoeppelwerth & AssoCiates, Inc. 9940 ^llisonville Road Fishers, IN 46038 RE' Job Number: 37963 Dear Mr. Robinson' I have received and reviewed the plans submitted for the above-mentioned project. At the present time, I see nothing in the plans that would hamper law enforcement efforts. If we can be of any further assistance to you, please contact us. Respectfully, Michael D. Fogarty Chief of Police MDF'vb CC: Dept. of Community Services (517) 571-2500 A Nationally Accredite~!!:~: E:~orcement Agency F,., (517) 57~-25]12 HAMILTON COUNTY HIG A Y DEPAI T/ ENT January 8, 2004 Mr. Brian Robinson Stoeppelwerth and Associates, Inc. 9940 Allisonville Road Fishers, Indiana 46038-20135 RE: N Clay Township Dear Mr. Robinson: This letter serves to acknowledge receipt of a transmittal received 12/30103 containing the plans for the above-mentioned project. After reviewing the plans the Highway Department has the following comments: 1, An Application for Project Review needs to be completed and the appropriate review fees for a Secondary Plat paid1 before any approvals will be granted from this office, The fees for the Construction Plan review have been received. 2. Please note that decorative signs, sprinkler systems, trees, landscaping mounds, fences, light poles or other such amenities are not permitted in the fight of way. 3. The entrance on .US 421 must be permitted through INDOT. 4. In the earthwork notes on the Site Development Sheets, note 6B must read.0.05, not 0.10. 5. A minimum of 10' of fight of way is required behind the curb of the street. The necessary right of way does not exists west of the intersection of Lemongrass and Weston Pointe Drive. 6. The curb return radius on Sheet C405 does not meet the 35' minimum standard. It appears the radius has .been mislabeled. 7. Triangular right of way cuts are necessary at the entrance. The triangular cut must consist of two 50' legs. 8, Show any instrument numbers associated with right of way acquisition along US 421. 9. A Drainage and Utility Easement is needed behind the right of way along US 421. 113. Before any approvals are granted for the secondary plat, performance bonds must be submitted for 100% of the construction cost of the following Items: Stone Base, HAC Binder, HAC surface. Concrete Curbs and Street Name and Regulatory Signs. 11. Note that existing Monitor Lane curb and asphalt must be saw cut prior to connections being made. 12. Note the type of curb to be used. Chairback Curb with a reveme slope must be used around the medians in Weston Pointe Ddve. 13. Valley curb will be required across the entrances to the private streets. This will allow for distinction between the public and private streets as well as for a continuous sub surface drain. 700 South 10:h Street Noblesville, lli146060 Office (317) 773-7770 l~ax (317) 776-9814 JAN-OB-2004 11'37 FROM'HAMILTON C~ HNY DEP 3177769814 T0:-~17 571 2426 P. 002x002 14. Include all of the necessary HCHD Standard Details. C-1, C-5, P-l, U-2 and U-4. Remove the unapproved details shown on Sheet C802. 15. A construction drive must be shown on the Erosion Control Plan. 16. Pavement markings at the entrance must be shown on the Site Development Plan. Stop Bars, Turn Arrows and Lane Markings must be included. 17. Please include the following note on the sanitary sewer sheets: All sanitary sewer laterals that cross the street must be backfilled with full depth granular backfill. 18, On the water main sheets, the following notes need to be included: No water main valves will be permitted between the curbs, and Full depth granutar backfill is required at all street crossings. 19. Please note that all granular backfill must be mechanically compacted. 20, Granular backfill must be shown between structures 645-646. 21. In the General Notes on Sheet C800, note #13 must say Hamilton County Highway Department. 22. A Testing and Inspection Agreement will need to be executed prior the start of construction. I will forward the agreement to Portrait Homes under separate cover. 23. Please note that further comments will be necessary when construction plans are completed. If you have any questions or comments concerning this letter, please feel free to contact me at anytime. Sincerely, St'even J, Broermann Staff Engineer Jon Dobosiewicz Greg Hoyes G:~USER~$B\04,tac~O1-08.03westonpolnte.doc Construction/Stormwater Pollution Prevention Plan Technical Review and Comment (Form D eot Name: Weston Point Sec. 1 County: Hamilton Plan Submittal Date: 12/30/03 Hydrologic Unit Code: not provided Project Location Description: east side of US421 south of 116th Street 23 acres Latitude and Longitude: not provided Civil Township: Clay Quarter: SW Section: 6 Township: 17N Range: 3E Project Owner Name' Portrait Homes LLC Contact: Christine Pasquinelli Address: 8250 Haverstick Road, Suite 110 City: Indianapolis State: IN Zip: 46240 Phone: 317-259-897 lext 111 FAX: E-Mail: Plan Preparer Name: James Rinehart IV Affiliation: Stoeppelwerth and Associates Address: 9940 Allisonville Road City: Fishers State: IN Zip: 46038 Phone: 317-849-5935 FAX: 317-849-5942 E-Mail: I~]Review Date: 01/13/04 Principal Plan Reviewer: John B. South P.E. CPESC 'g Agency: Hamilton County Soil and Water Conservation District i Address: 1108 South 9th Street City: Noblesville State: IN Zip: 46060 Phone: 317-773-2181 FAX: 317-776-1101 E-Mail: john-south~iaswcd.org Assisted By: [~] PLAN IS ADEQUATE: A comprehensive plan review has been completed and it has been determined that the plan satisfies the minimum requirements and intent of 327 IAC 15-5. [~ Please refer to additional information included on the following page(s). V-] Submit Notice of Intent (NOD: Attach a copy of this cover page when submitting the NOI to the Indiana Department of Environmental Management. Construction activities may begin 48 hours following the submittal of the NOI. A copy of the NOI must also be sent to the Reviewing Authority (e.g. SWCD, DNR). ~] A preliminary plan review has been completed; a comprehensive review will not be completed within the 28-day review period. The reviewing authority reserves the right to perform a comprehensive review at a later date and revisions to the plan may be required at that time to address deficiencies. [--] Please refer to additional information included on the following page(s). [~ Submit Notice of Intent (NOI): Attach a copy of this cover page when submitting the NOI to the Indiana Department of Environmental Management. Construction activities may begin 48 hours following the submittal of the NOI. A copy of the NOI must also be sent to the Reviewing Authority (e.g. SWCD, DNR). ~-~ PLAN IS DEFICIENT: Significant deficiencies were identified during the plan review. [-~ Please refer to additional information included on the following page(s). ITl DO NOT file a Notice of Intent for this project. [~ DO NOT commence land disturbing activities until all deficiencies are adequately addressed, the plan re- submitted, and notification has been received that the minimum requirements have been satisfied. V~ Plan Revisions V~] Deficient Items should be mailed or delivered to the Principal Plan Reviewer identified in the Plan Review Section above. DNR, Division of Soil Conservation Page I of 4 Revised 12/09/03, Form 1 Construction/Stormwater Pollution Prevention Plan - Technical Review and Comment (Form 1) IIProject Name: Weston Point Sec. 1 IDate Reviewed' 01/13/04 The technical review and comments are intended to evaluate the completeness of the Construction/Stormwater Pollution Prevention Plan for the project. The Plan submitted was not reviewed for the adequacy of the engineering design. All measures included in the plan, as well as those recommended in the comments shouM be evaluated as to their feasibility by a qualified individual with structural measures designed by a qualified engineer. The Plan has not been reviewed Cor other local, state, or federal permits that may be required to proceed with this project. Additional information, including design calculations may be requested to further evaluate the Plan. All proposed stormwater pollution prevention measures and those referenced in this review must meet the design criteria and standards set forth in the "Indiana Stormwater Quality Manual"from the Indiana Department of Natural Resources, Division of Soil Conservation or similar Guidance Documents. Please direct questions and/or comments regarding this plan review to: John B. South P.E. CPESC Please refer to the address and contact information identified in the Plan Review Section on page 1. Assessment of Construction Plan Elements (Section A) The Construction Plan Elements are adequately represented to complete a plan review: ~ Yes ~ No The items checked below are deficient and require submittal to meet the requirements of the rule. A A 11 by 17 inch plat showing building lot IV] I Index showing locations of required Plan Elements [-7]2 numbers/boundaries and road layout/names ~-I 3 Narrative describing the nature and purpose of the [---] 4 Vicinity map showing project location project Legal Description of the Project Site [-] 6 Location of all lots and proposed site [--]5 (Include Latitude and Longitude - NOI Requirement) improvements (roads, utilities, structures, etc.) Notation of any State or Federal water quality [5] 7 Hydrologic unit code (14 Digit) [~] 8 permits r_]~_~ 9 Specific points where stormwater discharge will leave [~ 10 Location and name of all wetlands, lakes and the site water courses on and adjacent to the site Identification of potential discharges to ground ~l 11 Identification of all receiving waters [-] 12 water (abandoned wells, sinkholes, etc.) Pre-construction and post construction estimate of [~] 13 100 year floodplains, floodways, and floodway fringes [~] 14 Peak Discharge (10 Year storm event) Locations and approximate boundaries of all [--]15 Adjacent landuse, including upstream watershed ~ 16 disturbed areas (Construction Limits) Soils map including soil descriptions and ~-] 17 Identification of existing vegetative cover [~] 18 limitations [-] 19 Locations, size and dimensions of proposed stormwater [~] 20 Plans for any off-site construction activities systems (e.g. pipes, swales and channels) associated with this project (sewer/water tie-ins) [-1 21 Locations of proposed soil stockpiles and/or ~] 22 Existing site topography at an interval appropriate borrow/disposal areas to indicate drainage patterns Proposed final topography at an interval appropriate to ~ 23 indicate drainage patterns DNR, Division of Soil Conservation Page 2 of 4 Revised 12/09/03, Form 1 Construction/Stormwater Pollution Prevention Plan - Technical Review and Comment (Form 1) Il)ate Reviewed' 01/13/04 Assessment of Stormwater Pollution Prevention Plan (Sections B & C) :.i~i~?~?~ilili!iii!i!i~i~i The construction component of the Stormwater Pollution Prevention Plan includes stormwater quality i!iiiiiii!i!iiii!~iiiiiii measures to address erosion, sedimentation, and other pollutants associated with land disturbance and .~ iiiiiiii!iiii!i!!!i!i!!!i construction activities. Proper implementation of the plan and inspections of the construction site are o iiiiii~?????~i?~!ii~ necessary to minimize the discharge ofpollutants. The Project Site Owner shouM be aware that .~. ~ unforeseen construction activities and weather conditions may affect the performance of a practice or the ~ ~ ~ effectiveness of the plan. The plan must be aflexible document, with provisions to modify 'or substitute '~ ~ ~ B practices as necessary. [-] [Z] .......................... I Description of potential pollutant sources associated with construction activities ~ Sequence describing stormwater quality measure implementation relative to land disturbing [-]~] 2 activities [7] [-] ............. 3 Stable construction entrance locations and specifications (at all points of ingress and egress) [~] [--][-] 4 Sediment control measures for sheet flow areas ~-] [~ [--] 5 Sediment control measures for concentrated flow areas [~ VT] [-] 6 Storm sewer inlet protection measure locations and specifications [-] [~] ~ 7 Runoff control measures (e.g. diversions, rock check dams, slope drains, etc .) ~] [--][~ 8 Storm water outlet protection specifications [-] [-] [~J 9 Grade stabilization structure locations and specifications [-] [~J ........................... 10 Location, dimensions, specifications, and construction details of each stormwater quality measure [~J [-~ ........................... 11 Temporary surface stabilization methods appropriate for each season (include sequencing) [--]I-gl ~,::,~,::,::,::,::,::,::,::,::,~,~,~ 12 Permanent surface stabilization specifications (include sequencing) ~-] [7] .......................... ::'~ 13 Material handling and spill prevention plan [7] [--]............................ 14 Monitoring and maintenance guidelines for each proposed stormwater quality measure [--1[7] [~] 15 Erosion & sediment control specifications for individual building lots ~ The post construction component of the Stormwater Pollution Prevention Plan includes the !'~i~iiiii iiiiiiiiiii?,i',i',iii',iiiiiii implementation of stormwater quality measures to address pollutants that will be associated with the ~ final landuse. Post construction stormwater quality measures shouM be functional upon completion of ~ '~ the project. Long term functionality of the measures are critical to their performance and shouM be ~ ..... ~.:.:. :::::::~:':~'~ monitored and maintained ~-] [7] .......................... I Description of pollutants and their sources associated with the proposed land use [-] [~] 2 Sequence describing stormwater quality measure implementation .......................... Description of proposed post construction stormwater quality measures [--][~]~::~::~::~::~::~::~ .......................... 3 (Include a written description of how these measures will reduce discharge of expected pollutants) [~] ~1 .......................... 4 Location, dimensions, specifications, and construction details of each stormwater quality measure [---] [7] 5 Description of maintenance guidelines for post construction stormwater quality measures DNR, Division of Soil Conservation Page 3 of 4 Revised 12/09/03, Form 1 Construction/Stormwater Pollution Prevention Plan - Technical Review and Comment lProject Name: Wcston Point Sec. 1 IDate Reviewed: 01/13/04 A 18- You included the soil limitations but not how you will overcome these limitations. B2- A unique construction sequence is needed. B5- Currently the site drains to the north, west and south. How are these drainage areas addressed during rough grading of the site? Appropriate practices are needed to prevent offsite pollution. These practices need to be in place prior to disturbing the watershed. B6- Stone bags are not appropriate for storm inlets in the middle of the streets. Recommend inlet protection that fits into the catch basin. I have a list of suppliers if needed. B7- Runoff control measures could be used in conjunction with other perimeter protection. B 11, B 12- Seeding spec needs to include nutrient information, how the ground is prepared for seeding and how the seed B 15- Should the typical detail be modified for these larger structures? The website- www.hamiltonswcd.org provides additional information about completing the plan. cc: Carmel, Surveyor, File DNR, Division of Soil Conservation Page 4 of 4 Revised 12/09/03 From' Sent: To: Subject' Babbitt, Pamela A Tuesday, December 30, 2003 8:19 AM Brewer, Scott I; Butler, Angelina V; Dobosiewicz, Jon C; Hollibaugh, Mike P; Lillig, Laurence M; Pattyn, Dawn E newi Weston Pointe US 421 south of 116th Street Secondary Plat contact: Brian Robinson 577-3400 x16 849-5942 FAX 017) 849-5942 DATE: December 23, 2003 JOB NUMBER: 37963 TO' Department of Community Services 1 Civic Square Carmel, Indiana 46032 ATTENTION: Jon Doboiewicz RE: Westen Pointe WE ARE SENDING YOU [ X ] ups [ ] Courier [ ] Other: COPIES SHEET DESCRIPTION NO. 2 Sets Construction Plans 2 Secondary Plat 1 Plat Application with Description 1 Transmittals to Agencies 1 Drainage Calculation THESE ARE TRANSMITTED as checked below: [ ] For Approval [ X ] As Requested [ X ] For Your Use [ I [ ] For Review and Comment If you have any questions, please feel free to give me a call at (317) 577-3400, ext. 16. Thank you, Brian K. Robinson Cc.' Tina Pasquinelli Steve Pittman FAX (317) 849-5942 DATE: December 23, 2003 JOB NUMBER: 37963 TO: Department of Community Services 1 Civic Square Carmel, Indiana 46032 ATTENTION: Jon Doboiewicz RE: Westen Pointe WE ARE SEND]NGYOU [ X ] uPs [ ] Courier [ ] Other: COPIES SHEET DESCRIPTION NO. 2 Sets Construction Plans 2 Secondary Plat 1 Plat Application with Description 1 Transmittals to Agencies 1 Drainage Calculation THESE ARE TRANSMITTED as checked below: [ ] For Approval [ X ] As Requested [ ] For Review and Comment [ X] For Your Use [ ] If you have any questions, please feel free to give me a call at (317) 577-3400, ext. 16. Thank you, Brian K. Robinson Cc.' Tina Pasquinelli Steve Pittman FAX (317) 849-5942 DATE: December 23, 2003 JOB NUMBER: 37963 TO- Department of Community Services 1 Civic Square Carmel, Indiana 46032 ATTENTION: Jon Doboiewicz RE: Westen Pointe WE ARE SENDING YOU [ X] uPs [ ] Courier [ ] Other: COPIES SHEET DESCRIPTION NO. 2 Sets Construction Plans 2 Secondary Plat 1 Plat Application with Description 1 Transmittals to Agencies 1 Drainage Calculation THESE ARE TRANSMITTED as checked below: [ ] For Approval [ X ] As Requested [ ] For Review and Comment [ X ] For Your Use [ ] If you have any questions, please feel free to give me a call at (317) 577-3400, ext. 16. Thank you, Brian K. Robinson Cc.' Tina Pasquinelli Steve Pittman FAX (317) 849-5942 DATE: December 23, 2003 JOB NUMBER: 37963 TO: Department of Community Services 1 Civic Square Carmel, Indiana 46032 ATTENTION: Jon Doboiewicz RE: Westen Pointe WE ARE SENDING YOU [ X ] ups [ ] Courier [ ] Other: COPIES SHEET DESCRIPTION NO. 2 Sets Construction Plans 2 Secondary Plat 1 Plat Application with Description 1 Transmittals to Agencies 1 Drainage Calculation THESE ARE TRANSMITTED as checked below: [ ] For Approval [ X ] As Requested [ ] For Review and Comment [ X] For Your Use [ ] If you have any questions, please feel free to give me a call at (317) 577-3400, ext. 16. Thank you, Brian K. Robinson Cc' Tina Pasquinelli Steve Pittman LETTER OF TRANSMITTAL STOEPPELWERTH & ASSOCIATES, INC. 9940 Allisonville Road Fishers, Indiana 46038-2005 Phone (317) 849-5935 FAX (317) 849-5942 DATE: December 19, 2003 JOB NUMBER: 37963POR TO' Clay Township Regional Waste District 10701 North College Avenue Suite A Indianapolis, Indiana 46280-1098 ATTENTION: Jay Alley RE: Weston Pointe WE ARE SENDING YOU [ Xl t, es [ ]Courier [ ]Other: COPIES SHEET DESCRIPTION NO. 2 Sets Construction Plans 2 Secondary Plat .... 1 Wasteload Application Packet 1 certification of Professional Engineer , 1 Allocation Letter , THESE ARE TRANSMITTED as checked below: [ 1 For Approval [ X ] As Requested [ ] For Review and Comment I X ] For Your Use I I REMARKS: Greg, If you have any questions, please feel free to give me a call at (317) 577-3400, ext. 16. Cc.' Steve Pittman Tina Pasquinelli Jon Dobosiewicz Thank you, Brian K. Robinson LETTER OF TRANSMITTAL STOEPPELWERTH & ASSOCIATES, INC. 9940 Allisonville Road Fishers, Indiana 46038-2005 Phone (317) 849-5935 FAX (317) 849-5942 DATE: December 19, 2003 JOB NUMBER: 37963 TO: Carmel Utilities 1 Civic Square Carmel, Indiana 46032 ATTENTION: John Duffy RE: Westen Pointe WE ARE SENDING YOU [ X] ups [ ] Courier [ ] Other: COPIES 'SHEET ' DESCRIPTION NO. 1 Set Construction Plans 1 Secondary Plat 1 IDEM NOI Water Application , , THESE ARE TRANSMITTED as checked below: [ ] For Approval [ X ] As Requested [ ] For Review and Comment [ X ] For Your Use [ I REMARKS: If you have any questions, please feel free to give me a call at (317) 577-3400, ext. 16. Thank you, Brian K. Robinson Cc: Tina Pasquinelli Steve Pittman Jon Dobosiewicz LETTER OF TRANSMITTAL STOEPPELWERTH & ASSOCIATES, INC. 9940 Allisonville Road Fishers, Indiana 46038-2005 Phone (317) 849-5935 FAX (317) 849-5942 DATE: December 19, 2003 JOB NUMBER: 37963 TO' Hamilton County Highway Department 1700 South l0th Street Noblesville, Indiana 46060 ATTENTION: Steve Broermann RE' Westen Pointe WE ARE SENDING YOU [ X ] uPs [ ] Courier [ ] Other: COPIES SHEET DESCRIPTION NO. 1 Set Construction Plans 1 Secondary plat 1 ' AppliCation project Review 1 Check No. l~7 ~{' for $500.00 (Review Fee) , THESE ARE TRANSMITTED as checked below: [ 1 For Approval [ X ] As Requested [ ] For Review and Comment ! X ] For Your Use [ I REMARKS' If you have any questions, please feel free to give me a call at (317) 577-3400, ext. 16. Thank you, Brian K. Robinson Cc' Tina Pasquinelli Steve Pittman Jon Dobosiewicz FAX (317) 849-5942 DATE: December 19, 2003 TO: ATTENTION: Office of Police Chief Three Civic Square Carmel, Indiana 46032 Michael Fogarty RE' Weston Pointe JOB NUMBER: 37963 WE ARE SENDING YOU [ X ] uPs [ ] Courier I I Other: COPIES SHEET DESCRIPTION NO. 1 Set Construction Plans 1 Secondary Plat THESE ARE TRANSMITTED as checked below: I I For Approval [ X l As Requested l ] For Review and Comment For Your Use ! I REMARKS: If you have any questions, please feel free to give me a call at (317) 577-3400, ext. 16. Thank you, Brian K. Robinson Cc: Tina Pasquinelli Steve Pittman Jon Dobosiewicz LETTER OF TRANSMITTAL STOEPPELWERTH & ASSOCIATES, IN(?. 9940 Allisonville Road Fishers, Indiana 46038-2005 Phone (317) 849-5935 FAX (317) 849-5942 DATE: December 19, 2003 JOB NUMBER: 37963 TO: Carmel Communications 31 First Avenue NW Carmel, Indiana 46032 ATTENTION: Bill Akers RE: Weston Pointe WE ARE SENDING YOU [ XI ups [ ] Courier [ ] Other: COPIES SHEET DESCRIPTION NO. 1 Set Construction Plans 1 Secondary Plat THESE ARE TRANSMITTED as checked below: [ ] For Approval [ X ] As Requested [ ] For Review and Comment For Your Use I I REMARKS: If you have any questions, please feel free to give me a call at (317) 577-3400, ext. 16. Thank you, Brian K. Robinson Cc: Tina Pasquinelli Steve Pittman Jon Dobosiewicz FAX (317) 849-5942 DATE: December 19, 2003 JOB NUMBER: 37963 TO' Hamilton County Sheriff Department 18100 Cumberland Road Noblesville, Indiana 46060 ATTENTION: Lt. Joe Cook RE: Weston Pointe WE ARE SENDING YOU [ X l uPs [ I Courier I ] Other: COPIES SHEET DESCRIPTION NO. 1 Set Construction Plans 1 Secondary Plat THESE ARE TRANSMITTED as checked below: For Approval I X 1 As Requested ] For Review and Comment [ X ] For Your Use I I REMARKS: If you have any questions, please feel free to give me a call at (317) 577-3400, ext. 16. Thank you, Brian K. Robinson Cc: Tina Pasquinelli Steve Pittman Jon Dobosiewicz LETTER OF TRANSMITTAL STOEPPELWERTH & ASSOCIATES, INC. 9940 Allisonville Road Fishers, Indiana 46038-2005 Phone (317) 849-5935 FAX (317) 849-5942 DATE: December 19, 2003 JOB NUMBER: 37963 TO' Hamilton County Sheriff Department 18100 Cumberland Road Noblesville, Indiana 46060 ATTENTION: Lt. Joe Cook RE: Weston Pointe WE ARE SENDING YOU [ X] ups [ ] Courier [ ] Other: COPIES SHEET DESCRIPTION NO. 1 Set Construction Plans 1 Secondary Plat THESE ARE TRANSMITTED as checked below: ! ] For Approval [ X ] As Requested ! ] For Review and Comment For Your Use I I REMARKS: If you have any questions, please feel free to give me a call at (317) 577-3400, ext. 16. Thank you, Brian K. Robinson Cc: Tina Pasquinelli Steve Pittman ,Ion Dobosiewicz LETTER OF TRANSMITTAL STOEPPELWERTH & ASSOCIATES, IN(?. 9940 Allisonville Road Fishers, Indiana 46038-2005 Phone (317) 849-5935 FAX (317) 849-5942 DATE: December 19, 2003 JOB NUMBER: 37963 TO: Carmel Clay Parks Department 1055 Third Avenue SW Carmel, Indiana 46032 ATTENTION: John Lester RE: Weston Pointe WE ARE SENDING YOU [ X l uPs [ ] Courier I ] Other: COPIES SHEET DESCRIPTION NO. 1 Set Construction Plans . 1 Secondary Plat THESE ARE TRANSMITTED as checked below: [ ] For Approval [ X] As Requested [ ] For Review and Comment [ X ] For Your Use [ 1 REMARKS: If you have any questions, please feel free to give me a call at (317) 577-3400, ext. 16. Thank you, Brian K. Robinson Cc: Tina Pasquinelli Steve Pittman Jon Dobosiewicz STO NC. Phone (317) 849-5935 FAX (317) 849-5942 DATE: TO' ATTENTION: December 19, 2003 Carmel Clay School Administration 5185 East 131~t Street Carmel, Indiana 46033 Ron Farrand JOB NUMBER: 37963 RE: Weston Pointe WE ARE SENDING YOU [ X] ups [ ] Courier [ ] Other: COPIES SHEET DESCRIPTION NO. 1 Set Construction Plans 1 Secondary Plat THESE ARE TRANSMITTED as checked below: [ ] For Approval [ X ] As Requested [ ] For Review and Comment [ X ] For Your Use I I REMARKS: If you have any questions, please feel free to give me a call at (317) 577-3400, ext. 16. Thank you, Brian K. Robinson Cc: Tina Pasquinelli Steve Pittman Jon Dobosiewicz STOEPPELWERTH & AssoCIATES, INC. 9940 All!sonville_g_oa_d_ _- Fishers, Indiana_ 4603872005 Phone (317) 849-5935 FAX (317) 849-5942 DATE: December 19, 2003 JOB NUMBER: 37963 TO: Office of Fire Station Fire Station No. 1 Two Civic Square Carmel, Indiana 46032 ATTENTION: Gary Hoyt RE: Weston Pointe WE ARE SENDING YOU [ X] ups [ ] Courier [ ] Other: COPIES SHEET DESCRIPTION NO. 1 Set Construction Plans 1 Secondary Plat THESE ARE TRANSMITTED as checked below: [ ] For Approval [ X ] As Requested [ ] For Review and Comment For Your Use ! ! REMARKS: If you have any questions, please feel free to give me a call at (317) 577-3400, ext. 16. Thank you, Brian K. Robinson Cc: Tina Pasquinelli Steve Pittman Jon Dobosiewicz LETTER OF TRANSMITTAL STOEPPELWERTH & ASSOCIATES, INC. 9940 Allisonville Road Fishers, Indiana 46038-2005 Phone (317) 849-5935 FAX (317) 849-5942 DATE: TO' ATTENTION: December 19, 2003 City of Carmel Urban Forester 1 Civic Square Carmel, Indiana 46032 Scott Brewer JOB NUMBER: 37963 RE: Weston Pointe WE ARE SENDING YOU [ X l liPS [ I Courier [ I Other: COPIES SHEET DESCRIPTION NO. 1 Set Construction Plans 1 Secondary Plat THESE ARE TRANSMITTED as checked below: [ ] For Approval [ X ] As Requested [ ] For Review and Comment For Your Use I 1 REMARKS: If you have any questions, please feel free to give me a call at (317) 577-3400, ext. 16. Thank you, Brian K. Robinson Cc- Tina Pasquinelli Steve Pittman Jon Dobosiewicz FAX (317) 849-5942 DATE: December 19, 2003 JOB NUMBER: 37963 TO' City of Carmel City Engineer 1 Civic Square Carmel, Indiana 46032 ATTENTION: Dick Hill RE: Weston Pointe WE ARE SENDING YOU [ X] ups [ ] Courier [ ] Other: COPIES SHEET DESCRIPTION NO. 1 Set Construction Plans 1 Secondary Plat THESE ARE TRANSMITTED as checked below: [ ] For Approval [ X ] As Requested ] For Review and Comment [ X l For Your Use I 1 REMARKS: If you have any questions, please feel free to give me a call at (317) 577-3400, ext. 16. Thank you, Brian K. Robinson Cc' Tina Pasquinelli Steve Pittman Jon Dobosiewicz FAX (317) 849-5942 DATE: December 19, 2003 JOB NUMBER: 37963 TO' Samuel L. Moore & Associates 7102 Lakeview Parkway West Drive Indianapolis, Indiana 46268 ATTENTION: Vasco Kirby RE: Weston Pointe WE ARE SENDING YOU [ X] ups [ ] Courier [ /Other: COPIES SHEET DESCRIPTION NO. 1 Set Construction Plans THESE ARE TRANSMITTED as checked below: ! I For Approval I X 1 As Requested ! ] For Review and Comment [ X ] For Your Use I I REMARKS: Please review as soon as possible so that we can get package together and send to Clay Waste for IDEM. If you have any questions, please feel free to give me a call at (317) 577-3400, ext. 16. Cci Tina Pasquinelli Steve Pittman Jon Dobosiewicz Thank you, Brian K. Robinson LETTER OF TRANSMITTAL STOEPPELWERTH & ASSOCIATES, INC. 9940 Allisonville Road Fishers, Indiana 46038-2005 Phone (317) 849-5935 FAX (317) 849-5942 DATE: December 19, 2003 JOB NUMBER: 37963 TO: Hamilton County Soil & Water 1108 South 9th Street Noblesville, Indiana 46060 ATTENTION: John South RE: Weston Pointe WE ARE SENDING YOU [ X] uPs [ ] Courier [ ] Other: COPIES SHEET DESCRIPTION NO. 1 Set Construction Plans 1 Secondary Plat 1 Storm Calculations THESE ARE TRANSMITTED as checked below: [ ] For Approval [ X ] As Requested [ ] For Review and Comment [ X ] For Your Use I I REMARKS: If you have any questions, please feel free to give me a call at (317) 577-3400, ext. 16. Thank you, Brian K. Robinson C¢~ Tina Pasquinelli Steve Pittman Jon Dobosiewicz FAX (317) 849-5942 ~ ~ DATE' December 19, 2003 JOB NUMBER: 37963 TO' Office of Police Chief Three Civic Square Carmel, Indiana 46032 ATTENTION: Michael Fogarty RE' Weston Pointe WE ARE SENDING YOU [ X] ups [ ] Courier [ ] Other: COPIES SHEET DESCRIPTION NO. 1 Set Construction Plans 1 Secondary Plat THESE ARE TRANSMITTED as checked below: I I For Approval [ X l As Requested ] For Review and Comment [ X ] For Your Use I 1 REMARKS: If you have any questions, please feel free to give me a call at (317) 577-3400, ext. 16. Thank you, Brian K. Robinson Cc~ Tina Pasquinelli Steve Pittman Jon Dobosiewicz FAX (317) 849-5942 DATE: TO: ATTENTION: December 19, 2003 Carmel Communications 31 First Avenue NW Carmel, Indiana 46032 Bill Akers JOB NUMBER: 37963 RE' Weston Pointe WE ARE SENDING YOU [ X ] ups [ ] Courier [ ] Other: COPIES SHEET DESCRIPTION NO. 1 Set Construction Plans 1 Secondary Plat THESE ARE TRANSMITTED as checked below: [ ! For Approval [ X I As Requested [ 1 For Review and Comment ! X ] For Your Use ! I REMARKS: If you have any questions, please feel free to give me a call at (317) 577-3400, ext. 16. Thank you, Brian K. Robinson Cc: Tina Pasquinelli Steve Pittman Jon Dobosiewicz FAX (317) 849-5942 DATE: December 19, 2003 JOB NUMBER: 37963 TO' Hamilton County Sheriff Department 18100 Cumberland Road Noblesville, Indiana 46060 ATTENTION: Lt. Joe Cook RE: Weston Pointe WE ARE SENDING YOU [ X] ups [ ] Courier [ ]Other: COPIES SHEET DESCRIPTION NO. 1 Set Construction Plans 1 Secondary Plat THESE ARE TRANSMITTED as checked below: [ ] For Approval [ X ] As Requested [ ] For Review and Comment [ X ] For Your Use [ I REMARKS: If you have any questions, please feel free to give me a call at (317) 577-3400, ext. 16. Thank you, Brian K. Robinson Cc- Tina Pasquinelli Steve Pittman Jon Dobosiewicz FAX (317) 849-5942 DATE' December 19, 2003 JOB NUMBER: 37963 TO: Hamilton County Local Emergency 18100 Cumberland Road Noblesville, Indiana 46060 ATTENTION' Robert Hendricks RE: Westen Pointe WE ARE SENDING YOU [ X ] uPs [ ] Courier [ ] Other: COPIES SHEET DESCRIPTION NO. 1 Set Construction Plans 1 Secondary Plat THESE ARE TRANSMITTED as checked below: [ ] For Approval ! X ] As Requested [ ] For Review and Comment [ X ] For Your Use i I REMARKS' If you have any questions, please feel free to give me a call at (317) 577-3400, ext. 16. Thank you, Brian K. Robinson Cc: Tina Pasquinelli Steve Pittman Jon Dobosiewicz FAX (317) 849-5942 DATE: December 19, 2003 JOB NUMBER: 37963 TO: Carmel Clay Parks Department 1055 Third Avenue SW Carmel, Indiana 46032 ATTENTION: John Lester RE' Weston Pointe w~ ^a~ s~m~a you I x ] ~s I ] Courier [ ] Other: COPIES SHEET DESCRIPTION NO. 1 Set Construction Plans 1 Secondary Plat THESE ARE TRANSMITTED as checked below: [ ] For Approval [ X 1 As Requested [ ] For Review and Comment ! X l For Your Use i I REMARKS: If you have any questions, please feel free to give me a call at (317) 577-3400, ext. 16. Thank you, Brian K. Robinson Cc' Tina Pasquinelli Steve Pittman Jon Dobosiewicz FAX (317) 849-5942 DATE' December 19, 2003 JOB NUMBER' 37963 TO' Carmel Clay School Administration 5185 East 131st Street Carmel, Indiana 46033 ATTENTION: Ron Farrand RE: Weston Pointe WE ARE SENDING YOU [ X ] ups [ ] Courier [ ] Other: COPIES SHEET DESCRIPTION NO. 1 Set Construction Plans 1 Secondary Plat THESE ARE TRANSMITTED as checked below: [ ] For Approval [ X ] As Requested ] For Review and Comment ! X ] For Your Use ! 1 REMARKS: If you have any questions, please feel free to give me a call at (317) 577-3400, ext. 16. Thank you, Brian K. Robinson Cc- Tina Pasquinelli Steve Pittman Jon Dobosiewicz FAX (317) 849-5942 DATE: December 19, 2003 JOB NUMBER: 37963 TO' Office of Fire Station Fire Station No. 1 Two Civic Square Carmel, Indiana 46032 ATTENTION: Gary Hoyt RE: Weston Pointe WE ARE SENDING YOU I X] ups [ ] Courier [ ] Other: COPIES SHEET DESCRIPTION NO. 1 Set Construction Plans 1 Secondary Plat THESE ARE TRANSMITTED as checked below: ! ] For Approval [ X l As Requested [ ] For Review and Comment ! X ] For Your Use I ! REMARKS: If you have any questions, please feel free to give me a call at (317) 577-3400, ext. 16. Thank you, Brian K. Robinson Cc~ Tina Pasquinelli Steve Pittman Jon Dobosiewicz FAX (317) 849-5942 DATE: December 19, 2003 JOB NUMBER: 37963 TO: City of Carmel Urban Forester 1 Civic Square Carmel, Indiana 46032 ATTENTION: Scott Brewer RE' Weston Pointe WE ARE SENDING YOU [ X] ups [ ] Courier [ ] Other: COPIES SHEET DESCRIPTION NO. 1 Set Construction Plans 1 Secondary Plat THESE ARE TRANSMITTED as checked below: ! I For Approval ! X l As Requested [ ] For Review and Comment I X ] For Your Use ! ] REMARKS: If you have any questions, please feel free to give me a call at (317) 577-3400, ext. 16. Thank you, Brian K. Robinson Cc: Tina Pasquinelli Steve Pittman Jon Dobosiewicz FAX (317) 849-5942 DATE: December 19, 2003 JOB NUMBER: 37963 TO' City of Carmel City Engineer 1 Civic Square Carmel, Indiana 46032 ATTENTION: Dick Hill RE: Weston Pointe WE ARE SENDING YOU [ X ] ups [ ] Courier [ ] Other: COPIES SHEET DESCRIPTION NO. 1 Set Construction Plans 1 Secondary Plat THESE ARE TRANSMITTED as checked below: [ ] For Approval I X l As Requested [ ] For Review and Comment [ X ] For Your Use I 1 REMARKS: If you have any questions, please feel free to give me a call at (317) 577-3400, ext. 16. Thank you, Brian K. Robinson Cc~ Tina Pasquinelli Steve Pittman Jon Dobosiewicz ~, S TOE PPE L ~Wi.~~,~~~ao&.aaVi~lAl~~~~oCo ~ATE S, INC. FAX (317) 849-5942 DATE: December 19, 2003 JOB NUMBER: 37963 TO: Samuel L. Moore & Associates 7102 Lakeview Parkway West Drive Indianapolis, Indiana 46268 ATTENTION: Vasco Kirby RE: Weston Pointe WE ARE SENDING YOU [ X l UPS I ] Courier I I Other: COPIES SHEET DESCRIPTION NO. 1 Set Construction Plans THESE ARE TRANSMITTED as checked below: [ ] For Approval ' [ X ] As Requested [ ] For Review and Comment [ X ] For Your Use I I REMARKS: Please review as soon as possible so that we can get package together and send to Clay Waste for IDEM. If you have any questions, please feel free to give me a call at (317) 577-3400, ext. 16. Cc: Tina Pasquinelli Steve Pittman Jon Dobosiewicz Thank you, Brian K. Robinson FAX (317) 849-5942 DATE: December 19, 2003 JOB NUMBER: 37963 TO' Hamilton County Soil & Water 1108 South 9th Street Noblesville, Indiana 46060 ATTENTION: John South RE: Weston Pointe WE ARE SENDING YOU I X ] ups [ ] Courier I ] Other: COPIES SHEET DESCRIPTION NO. 1 Set Construction Plans 1 Secondary Plat 1 Storm Calculations THESE ARE TRANSMITTED as checked below: [ I For Approval [ X l As Requested ] For Review and Comment [ X ] For Your Use I I REMARKS: If you have any questions, please feel free to give me a call at (317) 577-3400, ext. 16. Thank you, Brian K. Robinson Cc: Tina Pasquinelli Steve Pittman Jon Dobosiewicz