Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
AA149 PARTIAL PLANS SOUTH N.1-P
37 38 39 CCC.A.ASI.11, 9/18/09 CCC.A.ASI.12, 9/29/09 CCC.A.ASI.13, 9/30/09 Project: Developer: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: By: Sheet Title: CARMEL CITY CENTER Carmel, Indiana Building A Phase 1 COPYRIGHT & OWNERSHIP OF DOCUMENTS Architecture / Project Management: Project Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue Date PEDCOR DESIGN GROUP LLC 0502.00 AA149 PARTIAL PLANS SOUTH N.1-P Bid Set 10/24/08 THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP,LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2006, 2007, 2008, 2009, JAMES R. STUTZMAN, AIA, CARMEL, INDIANA SCALE: NTS PLAN NORTH 28 22 16 H M AREA A AREA C AREA B R KEY PLAN BLDG A Friday, October 2, 2009; ALLDATA:MS:DESIGN:PROJECTS:CARMEL CITY CENTER:CCC Drawings:CCC Construction Doc:Building A:A.General:BLDG A SHELL FILES:NORTH MODULES:BLDG.A SOUTH N-P.1-100209.pln 39 39 N.1 N.5 P P.1 23.1 24 24.1 N 3 AA573 4 AA573 18 AA701 9 AA573 1'-0 1/4" 4'-10" 6'-10" 4'-11 1/8" 8 7/8" 11'-3 5/8" 8'-8 3/8" 1'-7 3/4" 1'-0 1/4" 1'-9 3/4" 5'-6 1/4" 3'-9 1/8" 4'-1" 4'-1" 4'-1" 6'-7 7/8" 2'-3 5/8" 12'-8 1/2" R.O. 1'-1" 1'-2 7/8" 1'-0 1/4" 7'-8 7/8" 1 1/2" 1'-11" 4'-4 5/8" 3'-7 3/8" 1'-7 1/8" 3 3/4" R 197'-61/8" 2 AA353 1 AA354 3 AA354 2 AA232 1 AA232 5 AA257 6 AA257 VBRK2 3 5 5 3 11 9 20 11 3 5 VBRK2 S6Di S6Di S6Di S6Di S6Di VEFIS VEFIS VEFIS VEFIS VEFIS VEFIS VEFIS 15 10 7 15 19 12 12 9 10 7 3 7 VEFIS S6D S6D VEFIS S6Di DR11 HEAD HT. = +8'-3" ABOVE STRUC. SLAB DR11 HEAD HT. = +9'-11" ABOVE STRUC. SLAB OPENING IN CFS STUD WALL, HEAD HT., REF. SECTIONS FOR BALCONY INFORMATION, SEE 03/ SA433 HEAD HT. = +8'-0" ABOVE STRUC. SLAB HEAD HT. = +8'-0" ABOVE STRUC. SLAB TYP. REF. DETAIL 17/AA701 WHERE PORCH AND EXTERIOR WALL INTERSECT W06 W06 W06 W06 W36 N N.1 N.5 P P.1 23.1 24 9 OR 10 AA505 9 OR 10 AA505 9 OR 10 AA505 9 OR 10 AA505 9 OR 10 AA505 9 OR 10 AA505 7 AA573 5'-3 1/2" 3'-6" 3'-6" 7'-5" 5'-2" 3'-6" 3'-6" 5'-2" 3'-6" 3'-6" 5'-3 1/2" 2'-1 1/2" 1'-0 1/4" 8'-6 1/2" 8 5/8" 6'-9 1/4" 2'-6 5/8" 4'-3 3/8" R.O. =9'-0" 3'-10 7/8" 11 3/8" 6" 1'-0 1/4" 5'-2" 3'-6" 3'-6" 5'-2" 1'-0 1/4" 8'-6 1/2" 2 1/2" 2 1/2" 2 1/2" 3 1/2" 6" 3" 8" 7'-2 3/4" 5'-11 1/8" 2'-3" 2 AA353 1 AA354 3 AA354 7 AA334 5 AA354 9 AA258 10 AA258 2 AA232 1 AA232 W30 W30 W30 W30 W30 W30 W30 W30 W30 W30 W30 W30 VBRK2 S6Di VEFIS VEFIS VEFIS VEFIS S6Di S6Di VEFIS 13 13 13 13 15 11 11 18 18 18 HEAD HT. = +21'-7" ABOVE SEVENTH FLOOR STRUC. SLAB CURTAIN WALL WINDOW & SKYLIGHT OVERHEAD, BY SINGLE MANUFACTURER FUTURE STAIR TO BELOW EDGE OF SLAB, REF TO S- SERIES DWGS EDGE OF SLAB, REF TO S-SERIES DWGS HEAD HT. = +21'-7" ABOVE SEVENTH FLOOR STRUC. SLAB HEAD HT. = +21'-7" ABOVE SEVENTH FLOOR STRUC. SLAB HEAD HT. = +21'-7" ABOVE SEVENTH FLOOR STRUC. SLAB CORNICE ABOVE OPEN TO BELOW SHADED PORTION OF WALL IS PARTIAL HEIGHT STUD WALL, T.O.W. =101'-2" SHADED PORTION OF WALL IS PARTIAL HEIGHT STUD WALL, T.O.W. =101'-2" REF TO ENLARGED ELEVATION SECTIONS AND A300 SERIES DWGS FOR ADDITIONAL DIMENSIONS FOR THIS AREA TUBE STEEL COLUMN, REF TO S-SERIES DWGS TUBE STEEL COLUMN, REF TO S-SERIES DWGS INTUMESCENT PAINTED COLUMNS, REF SHEET AA504 & AA505 FOR STEEL FIREPROOFING DETAILS INTUMESCENT PAINTED COLS, REF AA504 & AA505 REF.DTL. 1/AA538 SIM. CONC CURB BELOW CURTAIN WALL SILL N 23.1 24 24.1 N.1 N.5 P P.1 6 AA573 5 AA573 18 AA701 7'-8 7/8" 7'-5 1/4" 4'-1" 4'-1" 6'-7 7/8" 1'-0 1/4" 8'-8" 11'-2 5/8" 4'-3 3/8" 9'-0" 4'-1 7/8" 1'-8 3/8" 1'-0 1/4" R.O.= 9'-0" 2'-8" 16'-9 5/8" 1 1/2" 3 3/4" 3" 6" R 148'-37/8" 2 AA353 1 AA354 3 AA354 7 AA334 5 AA354 7 AA258 8 AA258 2 AA232 1 AA232 S6Di VEFIS VEFIS VBRK2 S6Di S6Di VBRK2 S3.5Bi S6Bi 9 20 15 7 20 15 VEFIS 3 5 3 3 11 7 15 10 10 11 7 VEFIS VEFIS DR26 HEAD HT. = +8'-3" ABOVE STRUC. SLAB ## INTUMESCENT PAINTED COLUMNS, REF SHEET AA504 & AA505 FOR STEEL FIREPROOFING DETAILS CURTAIN WALL WINDOW, BY SINGLE MANUFACTURER BYPASS WALL: BASE @ 83'-6", TOPS OF WALLS. SLOPE FROM 106'-3 3/4" TO 107'-1 1/4" , SEE ENLARGED ELEVATION FOR FOR BALCONY ADDITIONAL DIMENSIONS INFORMATION, SEE 01/ SA433 SECONDARY STEEL, TUBE STEEL COLUMN & LINTEL, REF TO S- SERIES DWGS (BID SET A305B) HEAD HT. = +8'-0" ABOVE STRUC. SLAB BYPASS WALL: BASE @ 83'-6" (SEVENTH FLR), T.O.W. @ +97'-2", SEE ENLARGED ELEVATION FOR ADDITIONAL DIMENSIONS INDICATES E.O.S. OF ROOF ABOVE TYP. REF. DETAIL 17/AA701 WHERE PORCH AND EXTERIOR WALL INTERSECT W06 W06 W06 : DENOTES CFS BYPASS WALLS LEGEND : DENOTES CFS WALLS NOTE: BASE AND T.O.W. ELEVATIONS ARE REFERENCED NEXT TO DIMENSION STRING. N.5 P N.1 24 23.1 24.1 P.1 27 28 N 1 AA573 2 AA573 1'-2 3/8" 11 1/2" 7 1/2" 1'-0 1/4" 1'-6 1/8" 11 1/2" 1'-7 1/2" 11 1/8" 2'-3 1/2" 1'-0 1/4" 1'-5 1/2" 2'-7 1/2" 2'-4 1/2" 8 3/8" 1'-8 1/2" 2'-7" 14'-9 3/8" 3'-2 5/8" 15'-1" 2'-7 1/2" 4'-6 3/8" 8'-10" 6'-7 5/8" 11'-0 3/8" 2'-3" 2'-6 3/8" 11'-1" 5 5/8" 11 7/8" 7'-5 1/8" 8'-8 1/2" 16'-6 1/8" 5 7/8" 1 AA353 2 AA354 4 AA354 6 AA334 2 AA258 3 AA258 4 AA258 1 AA258 1 AA232 2 AA232 6 6 6 6 6 6 11 3 5 3 5 3 5 9 17 12 12 12 12 TO OUTSIDE OF C.M.U. WALL TO OUTSIDE OF C.M.U. WALL LINE OF C.M.U. WALL BELOW N.1 N.5 P P.1 23.1 24 24.1 N 18 AA701 11 AA573 8 AA573 11 AA573 1'-0 1/4" 5'-8" 6'-0" 5'-8" 9'-2 1/2" 4'-2" 6'-7 1/2" 1'-7 3/4" 4'-2" 1'-0 1/4" 4'-11 7/8" 4'-0" 13'-2 3/4" 4'-0" 3'-9 3/8" 2'-8" 1 1/2" 1'-11" 4'-4 1/8" 3'-7 7/8" 1'-7" 3 3/4" 4" 5 1/2" R 44'-31/2" R 44'-31/2" 1 AA353 2 AA354 4 AA354 1 AA232 2 AA232 VEFIS S6Di VEFIS 3 5 5 3 5 3 11 11 3 5 9 20 VEFIS VEFIS VBRK2 VBRK2 S6Di S6Di S6Di 15 10 7 10 7 7 7 16 16 DR03 HEAD HT. = +8'-3" ABOVE STRUC. SLAB DR03 HEAD HT. = +8'-0" ABOVE STRUC. SLAB FOR BALCONY INFORMATION, SEE 04/SA433 HEAD HT. = +8'-0" ABOVE STRUC. SLAB HEAD HT. = +8'-0" ABOVE STRUC. SLAB SIM. TYP. REF. DETAIL 17/AA701 WHERE PORCH AND EXTERIOR WALL INTERSECT Building A 2-4 apartment Gross W06 W06 W06 W06 W06 W06 1 2 3 5 6 8 4 9 10 11 12 13 14 15 7 16 17 18 19 20 EDGE OF CONC. CURB STONE BASE BELOW METAL RAILING, REF. DETAIL 1/AA705 AND S-SERIES DRAWINGS FOR RAILING ATTACHMENT @ JAMB. TUBE STL. COLUMN, REF. S-SERIES DRAWINGS. PLAN NOTES STEEL COLUMN, REF. S-SERIES DRAWINGS. PAINTED PVC TRELLIS ABOVE REFER TO SHEET AA504 & AA505 FOR TYP. STRUCTURAL FIREPROOFING DETAILS EIFS SOFFIT OVERHEAD REF TO ADJACENT FACADE DWGS DRAWING LIMITS TO THIS LINE EIFS OVERHEAD FACE OF EIFS CORNICE ABOVE EDGE OF SLAB/ROOF DECK, REF S-SERIES DWGS EDGE OF STANDING SEAM ROOF OVERHEAD LINE OF MTL. CAP BELOW EXHAUST HOOD ABOVE. SEE BLDG. ELEVS. WALL FRAMING IS REQUIRED TO BE HEADED OFF @ OCCURRANCES OF HOLES IN THE PRIMARY STEEL FRAMING VERIFY STORM DRAIN LOCATION 3"X4" PREFINISHED MTL. DOWNSPOUT METAL RAILING, REF. DETAIL 5/AA705 AND S-SERIES DRAWINGS FOR RAILING ATTACHMENT @ JAMB. SIMILAR TO 1/AA705 FOR JAMBS AND SIMILAR TO 4/AA705 FOR SILL. N P P.1 24 23.1 2'-10 5/8" 2'-10 5/8" 2'-10 5/8" 2'-10 5/8" 2'-10 5/8" 2'-10 5/8" 2'-9 1/2" 2'-9 1/2" 10 1/2" 3'-6 1/8" 1'-2 1/8" 1'-2 1/8" 1'-2 1/8" 2 AA353 1 AA354 3 AA354 7 AA334 5 AA354 9 AA258 10 AA258 2 AA232 1 AA232 EDGE OF STANDING SEAM ROOF EDGE OF PREFINISHED MTL. CORNICE SYSTEM W/ BUILT-IN GUTTER BELOW LINE OF EXTERIOR WALL BELOW EDGE OF STANDING SEAM ROOF EDGE OF STANDING SEAM ROOF LINE OF EXTERIOR WALL BELOW ALUM. CURTAINWALL SKYLIGHT SYSTEM, BY SINGLE MANUFACTURER PAINTED PVC TRELLIS STEEL BEAMS, REF. STRUCT. DWGS. LINE OF CORNICE BELOW PAINTED PVC TRIM ENCLOSURE AROUND BEAM PAINTED PVC COLUMN BASE ROOF VENTS (VENTING ATTIC). TOP VENT = 2SF NET AREA. SCALE: 1/4" = 1'-0" 3 SIXTH FLOOR AA149 0 2' 4' 8' SCALE: 1/4" = 1'-0" 5 EIGHTH FLOOR AA149 0 2' 4' 8' SCALE: 1/4" = 1'-0" 4 SEVENTH FLOOR AA149 0 2' 4' 8' SCALE: 1/4" = 1'-0" 1 FIRST FLOOR AA149 0 2' 4' 8' SCALE: 1/4" = 1'-0" 2 2ND-3RD-4TH-5TH FLOORS AA149 0 2' 4' 8' SCALE: 1/4" = 1'-0" 6 ROOF PLAN AA149 0 2' 4' 8' 10/24/08 A.300 JDR/JAW/BAB/JLS JAW/BAB 09/30/09