Loading...
HomeMy WebLinkAboutAA163 NORTH COLONADES - REFLECTED CEILING PLANSProject: Developer: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: By: Sheet Title: CARMEL CITY CENTER Carmel, Indiana Building A Phase 1 COPYRIGHT & OWNERSHIP OF DOCUMENTS Architecture / Project Management: Project Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue Date PEDCOR DESIGN GROUP LLC 0502.00 AA163 NORTH COLONADES - REFLECTED CEILING PLANS Bid Set !"#$%#!& THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP,LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2006, 2007, 2008, 2009, 2010, JAMES R. STUTZMAN, AIA, CARMEL, INDIANA 37 38 39 40 41 42 CCC.A.ASI.11, 9/18/09 CCC.A.ASI.12, 9/29/09 CCC.A.ASI.13, 9/30/09 CCC.A.ASI.14, 10/15/09 CCC.A.ASI.17, 01/07/10 CCC.A.ASI.18, 01/13/10 !"#$%&’()! !"#$%$&’() !" !! #$ % & ’()’*’ ’()’*+ ’()’*, ( !"#$%&’( )&*+$’ Tuesday, February 23, 2010; alldata:MS:DESIGN:PROJECTS:CARMEL CITY CENTER:CCC Drawings:CCC Construction Doc:Building A:A.General:BLDG A SHELL FILES:NORTH MODULES:BLDG. A NORTH M-N.pln 42 M M.5 N N.5 P 27.6 28 3'-4 1/2" 8'-0" 8'-0" 1'-10" 1'-10" 8'-0" 8'-0" 2'-2" 5'-2" 7'-0" 7'-0" 10" 3'-10" 7'-0" 7'-4" 1'-10" 1'-2 1/2" 7'-5 1/4" 1'-6" 3'-2 1/2" 7'-5 1/4" 1'-6" 3'-2 1/2" 7'-5 1/4" 1'-6" 1'-2 1/2" 14'-8" EQ. 4'-0" EQ. EQ. EQ. 9'-9" 10'-3" 8'-6" 8'-3" 6'-11" 7'-3" 6'-9" EQ. 7'-6" +14'-0" AFF +12'-0" AFF +12'-0" AFF +14'-0" AFF +14'-0" AFF +14'-0" AFF +13'-0" AFF +12'-0" AFF +13'-0" AFF +12'-0" AFF +12'-0" AFF +12'-0" AFF +13'-0" AFF S8Di HARD SHELL CLG. HARD SHELL CLG. ACCESSIBLE CLG. ACCESSIBLE CLG. ACCESSIBLE CLG. ACCESSIBLE CLG. HARD SHELL CLG. HARD SHELL CLG. HARD SHELL CLG. HARD SHELL CLG. HARD SHELL CLG. HARD SHELL CLG. A A A A A A A A A A A A A A A A TYP. TYP. EXTERIOR PERIMETER LIGHTING COLONNADE LIGHTING COLONNADE LIGHTING EXTERIOR PERIMETER LIGHTING Q Q.5 R 28 27.6 Q.2 3'-0" 8'-0" 8'-0" 3'-0" 8'-0" 8'-0" 3'-0" 3'-3 1/2" 4'-0 3/8" 3'-3 1/2" 1'-6" 1'-6" 9'-0" 8'-0" 8'-0" 9'-0" 3'-6" 3'-6" 14'-0" AFF 14'-0" AFF ACCESSIBLE CLG. HARD SHELL CLG. ACCESSIBLE CLG. control joints control joints A A A A A EXTERIOR PERIMETER LIGHTING COLONNADE LIGHTING H 27 26 25 24.1 25.7 3'-8 3/8" 6'-2 1/2" 6'-2 1/2" 6'-2 1/2" 6'-2 1/2" 7'-6" 7'-6" 7'-6" 7'-6" 6'-10 1/2" 6'-10 1/2" 6'-10 1/2" 6'-10 1/2" 2'-6" 1'-2 3/8" 1'-8 3/8" 1'-6 3/8" 7'-11 1/4" 3'-8 3/8" 7'-7 1/8" EQ. EQ. EQ. 5'-8" 5'-8" 5'-8" EQ. 7'-6" EQ. 4'-0" EQ. EQ. EQ. EQ. 1 6'-2 1/2" 6'-2 1/2" 6'-2 1/2" EQ. 1 EQ. 2 7'-6" 7'-6" 7'-6" EQ. 2 EQ. 3 6'-10" 6'-10" 6'-10" EQ. 3 EQ. 6'-4" 6'-4" 6'-4" EQ. EQ. +12'-0" AFF +14'-0" AFF +14'-0" AFF +12'-0" AFF +12'-0" AFF +12'-0" AFF +12'-0" AFF +14'-0" AFF +14'-0" AFF +14'-0" AFF +14'-0" AFF +14'-0" AFF ACCESSIBLE CLG. HARD SHELL CLG. HARD SHELL CLG. HARD SHELL CLG. HARD SHELL CLG. ACCESSIBLE CLG. ACCESSIBLE CLG. ALIGN LIGHTS BETWEEN COLUMN LINES 25 AND 26 HARD SHELL CLG. HARD SHELL CLG. HARD SHELL CLG. A A A A A A A A A A A A A A A A A A A A A A A A EXTERIOR PERIMETER LIGHTING COLONNADE LIGHTING COLONNADE LIGHTING COLONNADE LIGHTING SCALE: 1/4" = 1'-0" 1 NORTH M-N REFLECTED CEILING PLANS AA163 0 2' 4' 8' SCALE: 1/4" = 1'-0" 2 NORTH 25-28 (Q-R) REFLECTED CEILING PLAN AA163 0 2' 4' 8' SCALE: 1/4" = 1'-0" 3 NORTH H-J REFLECTED CEILING PLAN AA163 0 2' 4' 8' 01/13/2010 JAW 02.22.10 ASI 18 ITEMS: • LOCATION OF WALL SCONCE AND STYLE. • CORRECT WALL BASE PROFILE TO TO MATCH DETAILS. • CORRECTED STONE NUMBERS TO MATCH ASI 01. • ADDED SHEE TS AA269 AND AA163. • DIMENSIONAL REVISIONS IN CEILING PANELS AND SHADING OF REMOVABLE PANELS IN CEILING PLANS FOR CLARITY. SHOW GRID LAYOUT FOR REMOVABLE PANELS. • ADDED ANNUNCIATOR PANEL, LOBBY HEATER, PO BOX AND LOBBY KNOX BOX LOCATIONS. • CAN LIGHT LAYOUT - 02/022/10 REVISED 01.27.10 REVISED 02.22.10 LIGHTING NOTES 1. WALL SCONCE LIGHTS INSIDE OF COLONNADES AND PUBLIC PASSAGEWAYS SHALL BE 10'-0" AFF. 2. DIMENSIONING OF FIXTURES IS FROM TOP OF CROWN MOULD (INNER EDGE AWAY FROM WALL) TO FIXTURE TYPICALLY. 3. VISUAL LOCATION OF FIXTURES MAY NOT APPEAR AS NOTED ESPEICALLY WHEN INDICATED TO BE SPACED EQUALLY ("EQ") BY A DIMENSION. 4. CAN LIGHTS SHALL BE Spex S62H26QPLU- T62HQPLCS - LAMP: PHILIPS PL-T 26W/830/4P/ALTO BY OMEGA LIGHTING, 277 VOLT. 5. LIGHT CONTROL AND METERING: a. Colonnades shall be grouped to a meter. Exterior perimeter wall lighting shall be grouped to a meter. Exterior perimeter wall lighting is shown on various drawings. Public Passageways shall be grouped to a meter. b. !Can lights and wall sconces in Colonnades and Exterior perimeter wall lighting shall be on photocell. c. !Half of the can lights in the public passageways shall be on 24/7. The other half shall be on photocell. Wall sconces in the Public Passageways shall be on photocell. d. !In Public Passageways and Colonnades, any pathways leading from a egress path to the Public Way needs to be either on the stand-by power generator or battery back- up per the requirements of the code. E. !Service Corridors on the First Floor and Lower Retail shall be on a meter and operating 24/7. LIGHT FIXTURE LEGEND CAN LIGHT: Omega Spex S62H26QPLU-T62HQPLCS - LAMP: PHILIPS PL-T 26W/830/4P/ALTO , 277 volt WALL SCONCE: A