Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
AA301 Building Sections
Project: Developer: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: By: Sheet Title: CARMEL CITY CENTER Carmel, Indiana Building A Phase 1 COPYRIGHT & OWNERSHIP OF DOCUMENTS Architecture / Project Management: Project Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue Date PEDCOR DESIGN GROUP LLC 0502.00 AA301 Building Sections Bid Set 04.21.06 THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP,LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP,LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP,LLC. © COPYRIGHT 2006, 2007, 2008 JAMES R. STUTZMAN, AIA, CARMEL, INDIANA 13 12 11 14 15 16 CONSTRUCTION SET A.100; A.200 06/29/07 BID SET A.400 ISSUE, 08/17/07 A.100.ASI.012, A.200.ASI.001, 09/13/07 A.100.ASI.013, 12/14/07 BID SET A.400 RE-ISSUE, 09/19/08 BID SET A.210 ISSUE, 05/01/08 BID SET A.410 ISSUE, XX/XX/08 BID SET A.300 C.1 ISSUE, 06/27/08 SCALE: NTS PLAN NORTH 28 22 16 H M AREA A AREA C AREA B R KEY PLAN BLDG A Thursday, September 25, 2008; alldata:MS:DESIGN:PROJECTS:CARMEL CITY CENTER:CCC Drawings:CCC Construction Doc:Building A:A.100:Bid Set A.100.pln EL. = 2'-0" (850.00') EL. = 0'-0" (848.00') EL. = -0'-10" (847.17') EL. = -13'-0" (835.00') EL. = -17'-9" (830.25') EL. = -17'-6" (830.50') EL. = SEE STRUCTURAL T/PLAZA SLAB T/ FIN. FIRST FLOOR B/ PLAZA SLAB T/FOOTING T/HIGH PT. OF SLAB T/FOUNDATION WALL T/LOWER RETAIL F.F. EL. = 2'-0" (850.00') EL. = 0'-0" (848.00') EL. = -0'-10" (847.17') EL. = -13'-0" (835.00') EL. = -17'-9" (830.25') EL. = -17'-6" (830.50') EL. = SEE STRUCTURAL T/PLAZA SLAB T/ FIN. FIRST FLOOR B/ PLAZA SLAB T/FOOTING T/HIGH PT. OF SLAB T/FOUNDATION WALL T/LOWER RETAIL F.F. 3 AA301 5 - AA307 1 - AA305 - 6 AA502 P P.1 P.5 Q Q.2 Q.5 R R.1 R.2 R.3 R.5 R.6 S 14 AA501 1'-8" 1'-0" CONC. SLAB, REF. STRUCTURAL CONC. BEAM, REF. STRUCTURAL WATERPROOFING, SEE SPEC. FOR ALTERNATE @ VERTICAL WALLS (INCLUDING EXTERIOR RETAINING WALLS) CONC. FOOTING SYSTEM, REF. STRUCTURAL STORE FRONT VENEER, GLAZING SYSTEM, & OTHER CLADDING, N.I.C. FIRE PROTECTION ON ALL STEEL STRUCTURE CMU CONC. BEAM, REF. STRUCTURAL COORDINATE LADDER LOCATION W/ ELEVATOR MANUFACTURER RIGID INSULATION; PERIMETER FOUNDATION WALL PAVER SYSTEM, N.I.C. CONC. SLAB, REF. STRUCTURAL FUTURE SLAB BY TENANT HIGHEST POINT OF SLOPED PIT FLOOR WATERSTOP, TYP. WATERPROOFING COORDINATE SUMP PIT LOCATION W/ ELEVATOR MANUFACTURER, PROVIDE STEEL GRATE COVER & FRAME WATERPROOFING FIRE SEALANT @ ALL RATED ASSEMBLIES, TYP. FOUNDATION DRAINAGE SYSTEM, REF. PLUMBING DWGS. ELEVATOR SHAFT EA10 CONC. SLAB & GRANULAR FILL, REF. STRUCTURAL UNDER SLAB DRAINAGE, REF. MEP SERIES DRAWINGS COMPACTED BACKFILL, REF. STRUCTURAL BID SETS A.100 A.300 A.400 BID SETS A.300 A.400 P P.1 Q Q.2 6 AA502 5 AA307 - 3 AA301 1 - AA305 - 8 AA501 3 AA503 9 AA501 5 AA501 10" STORE FRONT SYSTEM, N.I.C. STAIR SYSTEM, N.I.C. CMU STAIR SHAFT SA7 FIRE PROTECTION ON ALL STEEL STRUCTURE MASONRY VENEER, N.I.C. PRECAST STRUCTURAL SYSTEM & TOPPING, N.I.C. STORE FRONT SYSTEM, N.I.C. CONC. SLAB IN A.100 CONTRACT CONC. BEAM, REF. STRUCTURAL CMU LINTEL, REF. STRUCTURAL DRAWINGS C.I.P. SLAB & BEAM, REF. STRUCTURAL WATERPROOFING, SEE SPEC. FOR ALTERNATE @ VERTICAL WALLS (INCLUDING EXTERIOR RETAINING WALLS) WATERPROOFING FOUNDATION DRAINAGE SYSTEM, REF. PLUMBING DWGS. RIGID INSULATION; PERIMETER FOUNDATION WALL BID SETS A.300 A.400 COORDINATE LADDER LOCATION W/ ELEVATOR MANUFACTURER MASONRY VENEER, N.I.C. PAVER SYSTEM, N.I.C. FIRE SEALANT @ ALL RATED ASSEMBLIES, TYP. CONSTRUCTION LIMIT LINE FUTURE SLAB BY TENANT CMU, PROVIDE MANSONRY VENEER ANCHORS EA11 ELEVATOR SHAFT UNDER SLAB DRAINAGE, REF. MEP SERIES DRAWINGS WATERSTOP, TYP. COORDINATE SUMP PIT LOCATION W/ ELEVATOR MANUFACTURER, PROVIDE STEEL GRATE COVER & FRAME WATERPROOFING BID SETS A.100 A.300 A.400 CMU, PROVIDE MASONRY VENEER ANCHORS 2 AA301 - 1 AA301 - 2 AA302 - 3 AA302 - 2 AA303 - 3 AA303 - 1 AA302 - 1 AA303 - 2 AA304 - 15.5 16 16.1 16.9 17 17.1 18 18.1 19 19.9 20 21 21.4 21.5 21.9 22 23 23.1 23.6 24 24.1 24.7 25 25.3 25.4 25.5 26 26.2 26.4 26.5 27 27.6 28 14 AA501 CMU, PROVIDE MASONRY VENEER ANCHORS FIRE PROTECTION ON ALL STEEL STRUCTURE BRICK VENEER N.I.C. PAVER SYSTEM N.I.C. BID SETS A.300 A.400 FIRE SEALANT @ ALL RATED ASSEMBLIES, TYP. CONCRETE SLAB IN A.100 CONTRACT CONSTRUCTION LIMIT LINE BID SETS A.100 A.300 A.400 R R.1 R.2 R.3 R.5 R.6 15.5 16 16.1 16.9 17 17.1 Q Q.2 R.3 R.5 2 AA301 - 14 AA501 CMU, PROVIDE MASONRY VENEER ANCHORS FIRE PROTECTION ON ALL STEEL STRUCTURE BRICK VENEER N.I.C. PAVER SYSTEM N.I.C. BID SETS A.300 A.400 FIRE SEALANT @ ALL RATED ASSEMBLIES, TYP. CONCRETE SLAB IN A.100 CONTRACT CONSTRUCTION LIMIT LINE BID SETS A.100 A.300 A.400 6 AA502 1'-8" 1'-0" CONC. SLAB, REF. STRUCTURAL CONC. BEAM, REF. STRUCTURAL WATERPROOFING, SEE SPEC. FOR ALTERNATE @ VERTICAL WALLS (INCLUDING EXTERIOR RETAINING WALLS) CONC. FOOTING SYSTEM, REF. STRUCTURAL STORE FRONT VENEER, GLAZING SYSTEM, & OTHER CLADDING, N.I.C. FIRE PROTECTION ON ALL STEEL STRUCTURE RIGID INSULATION; PERIMETER FOUNDATION WALL PAVER SYSTEM, N.I.C. CONC. SLAB, REF. STRUCTURAL FUTURE SLAB BY TENANT WATERSTOP, TYP. FOUNDATION DRAINAGE SYSTEM, REF. PLUMBING DWGS. CONC. SLAB & GRANULAR FILL, REF. STRUCTURAL UNDER SLAB DRAINAGE, REF. MEP SERIES DRAWINGS COMPACTED BACKFILL, REF. STRUCTURAL BID SETS A.100 A.300 A.400 BID SETS A.300 A.400 SCALE: 1/4" = 1'-0" 1 E/W BUILDING SECTION 18-19 AA301 0 2' 4' 8' 1 AA305 - 4 AA501 CMU CONC. BEAM, REF. STRUCTURAL COORDINATE LADDER LOCATION W/ ELEVATOR MANUFACTURER HIGHEST POINT OF SLOPED PIT FLOOR WATERPROOFING COORDINATE SUMP PIT LOCATION W/ ELEVATOR MANUFACTURER, PROVIDE STEEL GRATE COVER & FRAME WATERPROOFING FIRE SEALANT @ ALL RATED ASSEMBLIES, TYP. ELEVATOR SHAFT EA10 6 AA502 5 AA307 - 3 AA301 - 9 AA501 5 AA501 1 AA501 1 AA501 10" STORE FRONT SYSTEM, N.I.C. STAIR SYSTEM, N.I.C. FIRE PROTECTION ON ALL STEEL STRUCTURE MASONRY VENEER, N.I.C. STORE FRONT SYSTEM, N.I.C. CONC. SLAB IN A.100 CONTRACT CONC. BEAM, REF. STRUCTURAL CMU LINTEL, REF. STRUCTURAL DRAWINGS WATERPROOFING, SEE SPEC. FOR ALTERNATE @ VERTICAL WALLS (INCLUDING EXTERIOR RETAINING WALLS) WATERPROOFING FOUNDATION DRAINAGE SYSTEM, REF. PLUMBING DWGS. RIGID INSULATION; PERIMETER FOUNDATION WALL BID SETS A.300 A.400 COORDINATE LADDER LOCATION W/ ELEVATOR MANUFACTURER MASONRY VENEER, N.I.C. PAVER SYSTEM, N.I.C. EA11 ELEVATOR SHAFT UNDER SLAB DRAINAGE, REF. MEP SERIES DRAWINGS WATERSTOP, TYP. COORDINATE SUMP PIT LOCATION W/ ELEVATOR MANUFACTURER, PROVIDE STEEL GRATE COVER & FRAME WATERPROOFING BID SETS A.100 A.300 A.400 CMU, PROVIDE MASONRY VENEER ANCHORS SIM 1 AA305 - STAIR SHAFT SA7 FIRE SEALANT @ ALL RATED ASSEMBLIES, TYP. FUTURE SLAB BY TENANT CMU, PROVIDE MANSONRY VENEER ANCHORS 8 AA501 3 AA503 CMU PRECAST STRUCTURAL SYSTEM & TOPPING, N.I.C. C.I.P. SLAB & BEAM, REF. STRUCTURAL CONSTRUCTION LIMIT LINE SCALE: 1/64" = 1'-0" SECTION KEY SCALE: 1/64" = 1'-0" SECTION KEY SCALE: 1/64" = 1'-0" SECTION KEY SCALE: 1/4" = 1'-0" 3 N/S BUILDING SECTION R-R.5B AA301 0 2' 4' 8' SCALE: 1/4" = 1'-0" 2 E/W BUILDING SECTION 16.1-17 AA301 0 2' 4' 8' 04.21.06 A.100,A.210, A.400 RJP, JDR, JAW JAW 09.19.08