Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
AA309 ENVAC SECTIONS & PLANS
13 12 11 14 15 16 CONSTRUCTION SET A.100; A.200 06/29/07 BID SET A.400 ISSUE, 08/17/07 A.100.ASI.012, A.200.ASI.001, 09/13/07 A.100.ASI.013, 12/14/07 BID SET A.400 RE-ISSUE, 09/19/08 BID SET A.210 ISSUE, 05/01/08 BID SET A.410 ISSUE, XX/XX/08 BID SET A.300 C.1 ISSUE, 06/27/08 Project: Developer: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: By: Sheet Title: CARMEL CITY CENTER Carmel, Indiana Building A Phase 1 COPYRIGHT & OWNERSHIP OF DOCUMENTS Architecture / Project Management: Project Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue Date PEDCOR DESIGN GROUP LLC 0502.00 AA309 ENVAC SECTIONS & PLANS 04.21.06 THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP,LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP,LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP,LLC. © COPYRIGHT 2006, 2007, 2008 JAMES R. STUTZMAN, AIA, CARMEL, INDIANA SCALE: NTS PLAN NORTH 28 22 16 H M AREA A AREA C AREA B R KEY PLAN BLDG A Thursday, September 25, 2008; alldata:MS:DESIGN:PROJECTS:CARMEL CITY CENTER:CCC Drawings:CCC Construction Doc:Building A:A.100:Bid Set A.100.pln FIRST FLR +2'-0" SECOND FLR +20'-0" 1'-8 1/2" 8'-11" REVIEW S-SERIES DRAWINGS FOR BEAM & SLAB CONFIGURATION @ PIPE PENETRATION DISPOSAL DOOR BEYOND AAC DISPOSAL POINT CMU FIRE SEALANT @ ALL RATED ASSEMBLIES, TYP. DETAIL AROUND DISPOSAL POINT TO BE DETERMINED 2 HOUR RATED STUD WALL W/ GYPSUM BOARD BULKHEAD. REFERENCE S- SERIES DRAWINGS FOR MASONTY LINTEL REQUIREMENTS SCALE: 1/4" = 1'-0" 12 Envac Shaft 4 E/W SECTION 2 AA309 0 2' 4' 8' FIRST FLR +2'-0" LOWER RETAIL -13'-0" ENVAC PIPE PASSES BEYOND SECTION CUT AT THIS POINT PASSAGE PAO8 LOUVERED VENT COORDINATE LADDER LOCATION W/ ENVAC WATERPROOFING FIRE SEALANT @ ALL RATED ASSEMBLIES, TYP. FIRE DAMPER REVIEW S-SERIES DRAWINGS FOR C.I.P. BEAM & SLAB CONFIGURATION @ PIPE PENETRATION CMU ENVAC MACH. RM TA4 REFERENCE S- SERIES DRAWINGS FOR MASONTY LINTEL REQUIREMENTS SCALE: 1/4" = 1'-0" 11 Envac Shaft 4 E/W SECTION AA309 0 2' 4' 8' 11 AA309 - 23.1 23 Q.5 5 AA309 - 12 AA309 - Q.2 5'-6 1/4" 3'-1/4" 5'-2 1/4" 4'-6 3/8" 10 3/16" 1'-6 5/8" 6'-10 1/4" 2'-7 5/16" ### A6E A6E A6E A6E A6E DISPOSAL POINT SCALE: 1/4" = 1'-0" 10 ENVAC SHAFT 4 THIRD FLR PLAN AA309 0 2' 4' 8' 11 AA309 - 23.1 23 Q.5 5 AA309 - 12 AA309 - Q.2 5'-6 1/4" 4'-6 3/8" 3'-1/4" 5'-2 1/4" 10 3/16" 3'-8 3/4" 1'-9 1/2" 1'-6 5/8" 2'-7 5/16" 6'-10 1/4" ### A6E A6E A6E A6E A6E DISPOSAL POINT SCALE: 1/4" = 1'-0" 9 ENVAC SHAFT 4 SECOND FLR PLAN AA309 0 2' 4' 8' 5 AA309 - 11 AA309 - Q Q.2 23 12 AA309 - 4'-8" 3'-7 1/4" 1'-8 1/2" 5' 5'-5" 4'-3 1/2" 4" 3'-6 13/16" 5'-7 1/16" DA4 M8 M8 M8 M8 TRASH DISP. DA4 DISPOSAL POINT 2 HOUR RATED STUD WALL W/ GYPSUM BOARD BULKHEAD WALL ABOVE. SCALE: 1/4" = 1'-0" 8 ENVAC SHAFT 4 FIRST FLR PLAN AA309 0 2' 4' 8' 23.1 23 Q.2 11 AA309 - 5 AA309 - 12 AA309 - 2' 5'-10 7/8" 7'-3 1/4" 1'-9 1/8" 2'-8" 2'-2 5/8" 8" 3'-11 3/8" 3'-6 13/16" TA4 M8 M8 TA4A M8 TA4 TA4 TA4A DISPOSAL POINT LOUVERED VENT ABOVE DOOR COORDINATE LADDER LOCATION W/ ENVAC SCALE: 1/4" = 1'-0" 7 ENVAC SHAFT 4 PARKING LEVEL PLAN AA309 0 2' 4' 8' Q.2 5 AA309 - 11 AA309 - Q.5 23.1 23 8 3/8" 6'-6 7/8" 1' 9'-3/8" 4'-10 5/8" 3'-11 7/8" 3'-6 13/16" 1'-2 5/16" TA4 PIPE CONTINUES ON TO COLLECTION LINE INSPECTION POINT DISCHARGE VALVE AIR VALVE BEAM ABOVE SCALE: 1/4" = 1'-0" 6 ENVAC SHAFT 4 FOUNDATION LEVEL PLAN AA309 0 2' 4' 8' 5 AA502 FIRST FLR +2'-0" 2ND FLR +20'-0" LOWER RETAIL -13'-0" B/ PIPE -22'-1" PIPE CONTINUES ON TO COLLECTION LINE DISPOSAL RM TA4A ENVAC MACH. RM TA4 DISPOSAL POINT ENVAC PIPE PASSES INFRONT OF SECTION CUT AT THIS POINT AIR VALVE FIRE SEALANT @ ALL RATED ASSEMBLIES, TYP. DISCHARGE VALVE CMU INSPECTION POINT LOUVERED VENT & FIRE DAMPER BEYOND DETAIL AROUND DISPOSAL POINT TO BE DETERMINED LINKSEAL WATERPROOFING COORDINATE LADDER LOCATION W/ ENVAC REFERENCE S- SERIES DRAWINGS FOR MASONRY LINTEL REQUIREMENTS SCALE: 1/4" = 1'-0" 5 Envac Shaft 4 N/S SECTION AA309 0 2' 4' 8' P.5 #DrgID PARKING LEVEL -17'-9" #LayID FIRST FLR +2'-O" 2ND FLR +20'-0" DISCHARGE VALVE REVIEW S-SERIES DRAWINGS FOR C.I.P. BEAM & SLAB CONFIGURATION @ PIPE PENETRATION ENVAC MACH. RM TA3 PVC VENT TO ROOF OR BUILDING FACE, DETAIL BY ENVAC CMU ELASTOMERIC SEALANT EXPANSION JOINT FIRE SEALANT @ ALL RATED ASSEMBLIES, TYP. SCALE: 1/4" = 1'-0" 4 Envac Shaft 3 E/W SECTION AA309 0 2' 4' 8' 26 1 AA309 - 7 5/8" 6' 7 5/8" 7 5/8" 5'-4" 7 5/8" 2'-2 1/2" 7 5/8" DA3 M8 M8 M8 M8 M8 TRASH DISP. DA3 DISPOSAL POINT SCALE: 1/4" = 1'-0" 3 ENVAC SHAFT 3 FIRST FLR PLAN AA309 0 2' 4' 8' P.5 26 1 AA309 - 4 AA309 - 9'-1" 4'-7 3/4" 3'-9 5/8" 8'-2 1/2" 3'-8" 8" 6'-1 1/4" 1'-11 5/16" 1'-10" TA3 M8 M8 M8 TA3 M8 DISCHARGE VALVE REMOVABLE AIR VALVE/ INSPECTION POINT TA3 5'-4" x 4'-0" LOUVERED VENT ABOVE DOOR SCALE: 1/4" = 1'-0" 2 ENVAC SHAFT 3 PARKING LEVEL PLAN AA309 0 2' 4' 8' 26 2 AA206 B/ PIPE -22'-1" PARKING LEVEL -17'-9" FIRST FLOOR +2-0"' 2ND FLR +20'-0" ENVAC PIPE PASSES BEYOND SECTION CUT AT THIS POINT DISPOSAL POINT IN ROOM BEYOND ENVAC MACH. RM TA3 FIRE DAMPER DISCHARGE VALVE REVIEW S-SERIES DRAWINGS FOR C.I.P. BEAM & SLAB CONFIGURATION @ PIPE PENETRATION CMU PVC VENT TO ROOF OR BUILDING FACE IN ROOM BEYOND, DETAIL BY ENVAC ELASTOMERIC SEALANT EXPANSION JOINT PIPE CONTINUES ON TO COLLECTION LINE FIRE SEALANT @ ALL RATED ASSEMBLIES, TYP. REMOVABLE AIR VALVE /INSPECTION POINT LOUVERED VENT REFERENCE S- SERIES DRAWINGS FOR MASONTY LINTEL REQUIREMENTS REFERENCE S-SERIES DRAWINGS FOR MASONRY LINTEL REQUIREMENTS SCALE: 1/4" = 1'-0" 1 Envac Shaft 3 N/S SECTION AA309 0 2' 4' 8' Q.2 Q.2 09.29.06 A.100,A.210, A.400 JDR, LS JAW 09.19.08