Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
AA310 ENVAC SECTIONS & PLANS
13 12 11 14 15 16 CONSTRUCTION SET A.100; A.200 06/29/07 BID SET A.400 ISSUE, 08/17/07 A.100.ASI.012, A.200.ASI.001, 09/13/07 A.100.ASI.013, 12/14/07 BID SET A.400 RE-ISSUE, 09/19/08 BID SET A.210 ISSUE, 05/01/08 BID SET A.410 ISSUE, XX/XX/08 BID SET A.300 C.1 ISSUE, 06/27/08 Project: Developer: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: By: Sheet Title: CARMEL CITY CENTER Carmel, Indiana Building A Phase 1 COPYRIGHT & OWNERSHIP OF DOCUMENTS Architecture / Project Management: Project Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue Date PEDCOR DESIGN GROUP LLC 0502.00 AA310 ENVAC SECTIONS & PLANS 04.21.06 THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP,LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP,LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP,LLC. © COPYRIGHT 2006, 2007, 2008 JAMES R. STUTZMAN, AIA, CARMEL, INDIANA SCALE: NTS PLAN NORTH 28 22 16 H M AREA A AREA C AREA B R KEY PLAN BLDG A Thursday, September 25, 2008; alldata:MS:DESIGN:PROJECTS:CARMEL CITY CENTER:CCC Drawings:CCC Construction Doc:Building A:A.100:Bid Set A.100.pln 17.1 17 18 Q.2 10 AA310 - 3'-6 7/8" 6' 1'-10 3/4" 10'-1/2" 8" 5'-10 7/8" 9'-2 15/16" M8 M8 M8 RA04 TA6 TA6 TA6 DISPOSAL POINT LOUVERED VENT ABOVE DOOR SCALE: 1/4" = 1'-0" 11 ENVAC SHAFT 6 PARKING LEVEL PLAN AA310 0 2' 4' 8' 5 AA502 B/ PIPE -22'-1" FUTURE SLAB -13'-0" FIRST FLR +2'-0" 2ND FLR +20'-0" PIPE CONTINUES ON TO COLLECTION LINE AIR VALVE DISCHARGE VALVE INSPECTION POINT REVIEW S-SERIES DRAWINGS FOR C.I.P. BEAM & SLAB CONFIGURATION @ PIPE PENETRATION ENVAC PIPE PASSES BEYOND SECTION CUT AT THIS POINT ENVAC MACH. RM TA6 WATERPROOFING LINKSEAL PVC VENT TO ROOF OR BLDG FACE BEYOND FIRE SEALANT @ ALL RATED ASSEMBLIES, TYP. CMU LOUVER & FIRE DAMPER DETAIL AROUND DISPOSAL POINT TO BE DETERMINED T/ C.I.P. WALL REFERENCE S-SERIES DRAWINGS FOR MASONRY LINTEL REQUIREMENTS SCALE: 1/4" = 1'-0" 10 Envac Shaft 6 N/S SECTION AA310 0 2' 4' 8' 10 AA310 - Q.2 17.1 3'-6 9/16" 6'-2 1/4" 5'-7 5/8" 4" 4'-11 1/4" 4'-8 7/8" M8 M8 M8 M8 DA6 TRASH DISP. DA6 DISPOSAL POINT SCALE: 1/4" = 1'-0" 9 ENVAC SHAFT 6 FIRST FLR PLAN AA310 0 2' 4' 8' 10 AA310 - 17 17.1 Q.2 8" 6'-4" 13'-10 1/4" 5'-10 7/8" 9'-3 3/8" 4'-5 1/2" INSPECTION POINT DISCHARGE VALVE TA6 AIR VALVE BEAM ABOVE PIPE CONTINUES ON TO COLLECTION LINE SCALE: 1/4" = 1'-0" 8 ENVAC SHAFT 6 FOUNDATION LEVEL PLAN AA310 0 2' 4' 8' Q.2 19 5'-5 5/8" 5'-2 1/4" 3'-1/4" 4" 5'-0 5/8" 13'-5 1/4" A6E A6E A6E A6E ### A6E DISPOSAL POINT SCALE: 1/4" = 1'-0" 7 ENVAC SHAFT 5 THIRD FLR PLAN AA310 0 2' 4' 8' Q.2 19 2'-5 13/16" 2'-11 13/16" 5'-2 1/4" 5'-5 5/8" 4" 12'-3 7/8" 5'-3 1/4" A6E A6E A6E A6E ### A6E DISPOSAL POINT SCALE: 1/4" = 1'-0" 6 ENVAC SHAFT 5 SECOND FLR PLAN AA310 0 2' 4' 8' LOWER RETAIL -13'-6" FIRST FLR +2'-0" ENVAC MACH. RM TA5 ENVAC PIPE PASSES INFRONT OF SECTION CUT AT THIS POINT WATERPROOFING FIRE SEALANT @ ALL RATED ASSEMBLIES, TYP. CMU SCALE: 1/4" = 1'-0" 5 Envac Shaft 5 N/S SECTION AA310 0 2' 4' 8' 5 AA310 - Q.2 Q 19 6'-3/16" 4" 3 13/16" 5'-7 5/8" 6'-6 3/8" 12'-4 3/8" NTS 7'-8 5/16" M8 M8 M8 M8 DA5 TRASH DISP. DA5 DISPOSAL POINT SCALE: 1/4" = 1'-0" 4 ENVAC SHAFT 5 FIRST FLR PLAN AA310 0 2' 4' 8' 5 AA310 - 19.9 Q Q.2 1 AA310 - 7'-5 1/2" 6'-6 5/16" 8'-10" 7'-1 1/4" 6'-8" EQ. 6'-11 1/8" 5'-11 9/16" 10'-2 3/8" M8 M8 M8 TA5 M8 TA5A TA5 TA5 TA5A DISPOSAL POINT LOUVERED VENT ABOVE DOOR COORDINATE LADDER LOCATION W/ ENVAC EDGE OF SLAB SCALE: 1/4" = 1'-0" 3 ENVAC SHAFT 5 PARKING LEVEL PLAN AA310 0 2' 4' 8' 5 AA310 - 19.9 1 AA310 - Q Q.2 2'-61/8" 14'-1 5/8" 8'-2 1/4" 6'-1 15/16" 10'-1 15/16" 5'-11 9/16" 3'-7 5/16" TA5 PIPE CONTINUES ON TO COLLECTION LINE INSPECTION POINT AIR VALVE DISCHARGE VALVE BEAM ABOVE SCALE: 1/4" = 1'-0" 2 ENVAC SHAFT 5 FOUNDATION LEVEL PLAN AA310 0 2' 4' 8' 5 AA502 5 AA502 LOWER RETAIL -13'-0" B/ PIPE -22'-1" PIPE CONTINUES ON TO COLLECTION LINE ENVAC PIPE PASSES INFRONT OF SECTION CUT AT THIS POINT DISPOSAL RM TA5A ENVAC MACH. RM TA5 AIR VALVE DISCHARGE VALVE INSPECTION POINT COORDINATE LADDER LOCATION W/ ENVAC LINKSEAL FIRE DAMPER FIRE SEALANT @ ALL RATED ASSEMBLIES, TYP. FIRE SEALANT @ ALL RATED ASSEMBLIES, TYP. CMU LOUVERED VENT DETAIL AROUND DISPOSAL POINT TO BE DETERMINED WATERPROOFING REFERENCE S-SERIES DRAWINGS FOR MASONRY LINTEL REQUIREMENTS SCALE: 1/4" = 1'-0" 1 Envac Shaft 5 E/W SECTION AA310 0 2' 4' 8' 09.29.06 Bid Sets: A.100,A.210, A.400 JDR, LS JAW 09.19.08