Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
AA322 WALL SECTION AREA C 17-18
Project: Developer: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: By: Sheet Title: CARMEL CITY CENTER Carmel, Indiana Building A Phase 1 COPYRIGHT & OWNERSHIP OF DOCUMENTS Architecture / Project Management: Project Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue Date PEDCOR DESIGN GROUP LLC 0502.00 AA322 WALL SECTION AREA C 17-18 Bid Set !"#!$#%& THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP,LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2006, 2007, 2008, 2009, JAMES R. STUTZMAN, AIA, CARMEL, INDIANA 30 31 32 33 BID SET A.500, CCC.A.ASI.2, 5/15/09 PLUMBING FIXTURE DIMENSION UPDATE A.ASI.003, 05/29/09 STOREFRONT AND WALL BASE UPDATES 6/29/09 A.ASI.004, 06/10/09 !"#$%&’()! !"#$%$&’() !" !! #$ % & ’()’*’ ’()’*+ ’()’*, ( !"#$%&’( )&*+$’ Monday, July 13, 2009; ALLDATA:MS:DESIGN:PROJECTS:CARMEL CITY CENTER:CCC Drawings:CCC Construction Doc:Building A:A.General:BLDG A SHELL FILES:EAST MODULES:Bldg A-EAST LL 17-18.pln 32 32 R.6 2 AA535 8 AA534 3 AA206 +2'-0" +20'-0" REF. TO S-SERIES DWGS 15'-0" 18'-0" REF. TO S-SERIES DWGS TOP OF FOOTER 8" METAL STUD WALL W / 5/8" EXTERIOR SHEATHING GRANITE VENEER BASE STL. BEAM, REFER TO S- SERIES DWGS 2 1/4" AIR SPACE FULL HEIGHT OF WALL 8" CFS STUD WALL W / 5/8" EXTERIOR SHEATHING 2 1/4" AIR SPACE FULL HEIGHT OF WALL EPS FOAM N.I.C., REF. TO STRUCTURAL EXISTING CONC STRUC & SLAB AS SHOWN (FIELD VERIFY) EXISTING CONC STRUC & SLAB AS SHOWN (FIELD VERIFY) C.I.P. CONCRETE BEAM, REFER TO STRUCTURAL BUILT-UP EIFS PROFILE 8" CFS STUD WALL 3 COURSES 8" CMU, REFER TO STRUCTURAL BATT INSULATION SPRAY APPLIED FIRE RESISTIVE MATERIAL (N.I.C) SECOND FLOOR FIRST FLOOR LOWER RETAIL FLOOR REF S-SERIES DWGS 0.125" ALUMN. BRAKEMETAL CLAD CANOPY CANOPY ANCHOR BEYOND DETAIL REFERENCE APPLICABLE FROM TOP OF WALL VENEER TO TOP OF COPING DRYWALL (N.I.C.) DRYWALL (N.I.C.) VAPOR BARRIER WEATHER BARRIER VAPOR BARRIER WEATHER BARRIER STL. TUBE, REFER TO S- SERIES DWGS FUTURE SLAB N.I.C., REF. TO S-SERIES DWGS THRU-WALL FLASHING ROOFING MEMBRANE PREFINISHED METAL COPING INSULATION STOP BATT INSULATION, MIN REQUIRED BATT INSULATION, MIN REQUIRED TYPICAL COMPOSITE ROOF DECK PAVERS, HOLD 1/2" DOWN FROM TOP OF CONC CURB, REF. CIVIL DWGS 4" CONC SLAB, N.I.C. RIGID INSULATION, N.I.C. TOP OF SLAB CONC CURB, REF S- SERIES DWGS ARRISCRAFT, SHADOW STONE, JASPER, ASHLAR COURSING PATTERN ARRISCRAFT, SHADOW STONE, JASPER, ASHLAR COURSING PATTERN LIQUID APPLIED WATER PROOFING, N.I.C. R.6 9 AA534 1 AA535 3 AA206 REF. TO S-SERIES DWGS 15'-0" 18'-0" REF. TO S-SERIES DWGS TOP OF FOOTER +20'-0" +15'-2 1/2" TOP OF STEEL -13'-0" +2'-0" C.I.P. CONCRETE BEAM, REFER TO STRUCTURAL BUILT-UP EIFS PROFILE STL. BEAM, REFER TO STRUCTURAL STONE HEADER CURTAIN WALL WINDOW SYSTEM STOREFRONT WINDOW SYSTEM STONE HEADER CANOPY ANCHOR BEYOND 3 COURSES 8" CMU, REFER TO STRUCTURAL 8" METAL STUD WALL W / 5/8" EXTERIOR SHEATHING EXISTING CONC STRUC & SLAB AS SHOWN (FIELD VERIFY) EXISTING CONC STRUC & SLAB AS SHOWN (FIELD VERIFY) EFIS BRACKET BEYOND TOP OF SLAB BATT INSULATION SPRAY APPLIED FIRE RESISTIVE MATERIAL (N.I.C) SECOND FLOOR FIRST FLOOR LOWER RETAIL FLOOR STEEL BEAM & CHANNEL , REF TO STRUCTURAL REF TO S-SERIES DWGS 0.125" ALUMN. BRAKEMETAL CLAD CANOPY DRYWALL (N.I.C.) VAPOR BARRIER WEATHER BARRIER ROOFING MEMBRANE PREFINISHED METAL COPING INSULATION STOP BATT INSULATION, MIN REQUIRED TYPICAL COMPOSITE ROOF DECK COPPER-FABRIC THRU WALL FLASHING COUNTER FLASH W/ WEATHER BARRIER / DRAINAGE SYSTEM CONTINUOUS 2 1/4" AIR SPACE FUTURE SLAB N.I.C., REFER TO S-SERIES DWGS EPS FOAM N.I.C., REF. TO STRUCTURAL PAVERS, HOLD 1/2" DOWN FROM TOP OF CONC CURB, REF. CIVIL DWGS 4" CONC SLAB, N.I.C. RIGID INSULATION, N.I.C. CONC CURB W/ "LET-IN" FOR PAVERS AT ENTRY, REF S-SERIES DWGS STEEL ANGLE & S.S. ROD, REF TO STRUCTURAL STEEL TUBE & PLATE & ROD ASSEMBLY, REF TO S-SERIES DRAWINGS REF S-SERIES DWGS TOP OF STEEL TUBE HEADER LIQUID APPLIED WATER PROOFING, N.I.C. ARRISCRAFT, SHADOW STONE, JASPER, ASHLAR COURSING PATTERN COPPER-FABRIC THRU WALL FLASHING COUNTER FLASH W/ WEATHER BARRIER / DRAINAGE SYSTEM CONTINUOUS SELF-ADHERING RUBBERIZED ASPHALT FLASHING R.6 1 AA534 4 AA534 +20'-0" 18'-0" TOP OF FOOTER REF. TO S-SERIES DWGS +2'-0" -13'-0" 15'-0" REF. TO S-SERIES DWGS 8" METAL STUD WALL W / 5/8" EXTERIOR SHEATHING STONE BASE BRICK VENEER STL. BEAM, REFER TO S- SERIES DWGS 2 1/4" AIR SPACE FULL HEIGHT OF WALL 8" METAL STUD WALL W / 5/8" EXTERIOR SHEATHING 2 1/4" AIR SPACE FULL HEIGHT OF WALL EPS FOAM N.I.C., REF. TO STRUCTURAL EXISTING CONC STRUC & SLAB AS SHOWN (FIELD VERIFY) EXISTING CONC STRUC & SLAB AS SHOWN (FIELD VERIFY) C.I.P. CONCRETE BEAM, REFER TO STRUCTURAL BUILT-UP EIFS PROFILE 3 COURSES 8" CMU, REFER TO STRUCTURAL BATT INSULATION, MIN REQUIRED SPRAY APPLIED FIRE RESISTIVE MATERIAL (N.I.C) BRICK VENEER SECOND FLOOR FIRST FLOOR LOWER RETAIL FLOOR REF TO S-SERIES DWGS STL. COLUMN BEYOND DRYWALL (N.I.C.) WEATHER BARRIER VAPOR BARRIER FUTURE SLAB N.I.C., REFER TO S-SERIES DWGS COPPER FABRIC FLASHING & WEEP DRAINAGE SYSTEM PREFINISHED METAL COPING INSULATION STOP BATT INSULATION, MIN REQUIRED BATT INSULATION, MIN REQUIRED TYPICAL COMPOSITE ROOF DECK ROOFING MEMBRANE TOP OF SLAB PAVERS, HOLD 1/2" DOWN FROM TOP OF CONC CURB, REF. CIVIL DWGS 4" CONC SLAB, N.I.C. RIGID INSULATION, N.I.C. CONC CURB, REF S- SERIES DWGS 8" METAL STUD WALL W / 5/8" EXTERIOR SHEATHING CFS BRACING REQUIRED, AT SLAB LEVEL, BETWEEN STUD WALLS, @ 16" O.C. CFS BRACING REQUIRED, AT SLAB LEVEL, BETWEEN STUD WALLS, @ 16" O.C. NOTE: THIS DETAIL FOR INFORMATION ONLY, SEE ADJACENT FACADE DWGS, FUTURE BID SET LIQUID APPLIED WATER PROOFING, N.I.C. SCALE: 3/8" = 1'-0" 1 EAST WALL SECTION-1 AA322 0 2' 4' 6' SCALE: 3/8" = 1'-0" 2 EAST WALL SECTION-2 AA322 0 2' 4' 6' SCALE: 3/8" = 1'-0" 3 EAST WALL SECTION-3 AA322 0 2' 4' 6' 06/27/08 A300C.1 06.29.09