Loading...
HomeMy WebLinkAboutAA327 WALL SECTIONS AREA C LL EAST 19-20Project: Developer: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: By: Sheet Title: CARMEL CITY CENTER Carmel, Indiana Building A Phase 1 COPYRIGHT & OWNERSHIP OF DOCUMENTS Architecture / Project Management: Project Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue Date PEDCOR DESIGN GROUP LLC 0502.00 AA327 WALL SECTIONS AREA C LL EAST 19-20 Bid Set !"#$%#!& THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP,LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2006, 2007, 2008, 2009, JAMES R. STUTZMAN, AIA, CARMEL, INDIANA 30 31 32 33 BID SET A.500, CCC.A.ASI.2, 5/15/09 PLUMBING FIXTURE DIMENSION UPDATE A.ASI.003, 05/29/09 STOREFRONT AND WALL BASE UPDATES 6/29/09 A.ASI.004, 06/10/09 !"#$%&’()! !"#$%$&’() !" !! #$ % & ’()’*’ ’()’*+ ’()’*, ( !"#$%&’( )&*+$’ Monday, July 13, 2009; ALLDATA:MS:DESIGN:PROJECTS:CARMEL CITY CENTER:CCC Drawings:CCC Construction Doc:Building A:A.General:BLDG A SHELL FILES:EAST MODULES:Bldg A-EAST LL 19-20.pln 32 R.6 +20'-0" +21'-4" 15'-0" VARIES 1'-4" -13'-0" ±0'-0" +2'-0" T.O. STEEL 2'-10" 2'-11/2" GREEN ROOF SLAB BUILT-UP ALUMINUM CORNICE C.I.P. CONCRETE BEAM, REFER TO STRUCTURAL STL. BEAM, REFER TO STRUCTURAL PREFINISHED METAL COPING BUILT-UP ALUMINUM PROFILE CURTAIN WALL WINDOW SYSTEM 3 COURSES 8" CMU, REFER TO STRUCTURAL 8" METAL STUD WALL W / EXTERIOR SHEATHING EXISTING CONC STRUC & SLAB AS SHOWN (FIELD VERIFY) EXISTING CONC STRUC & SLAB AS SHOWN (FIELD VERIFY) BATT INSULATION SPRAY APPLIED FIRE RESISTIVE MATERIAL (N.I.C) EXISTING CONC STRUC & SLAB AS SHOWN (FIELD VERIFY) 0.125" BREAK METAL ALUMINUM PANEL INSULATION STOP BUILT-UP ALUMINUM HEADER BUILT-UP ALUMINUM PROFILE 0.125" BREAK METAL ALUMINUM PANEL BUILT-UP ALUMINUM SILL 0.125" BREAK METAL ALUMINUM PANEL BUILT-UP ALUMINUM CLAD CORNICE SYSTEM STOREFRONT WINDOW SYSTEM INSULATED HEADER BEAM, REF S-SERIES DWGS SECOND FLOOR T.O. SLAB LOWER RETAIL FLOOR T.O.W. HEIGHT VARIES VARIES DRYWALL N.I.C. T.O. SLAB EPS FOAM N.I.C. PAINTED MTL RAILING INSULATED CFS HEADER AT STOREFRONT WINDOW HEADER, TO BE FIELD BUILT TO ALLOW ATTACHMENT OF TOP TRACK TO C.I.P. CONC. BEAM, REF S-SERIES DWGS 8" CFS INSULATED BULKHEAD VERTICAL MULLION EXTENDS TO FLOOR SIM. REF 4/AA554 FOR PROFILE DETAILS 9 AA554 7 AA554 2 AA555 R.6 8 AA554 4 AA554 06 AA606 +15'-2" -13'-0" ±0'-0" +2'-0" TOP OF STEEL 15'-0" VARIES 5'-0" +25'-0" +20'-0" 2'-10" BUILT-UP ALUMINUM CORNICE PREFINISHED METAL COPING 0.125" BREAK METAL ALUMINUM PANEL CURTAIN WALL WINDOW SYSTEM 6" METAL STUD WALL W / EXTERIOR SHEATHING BATT INSULATION BUILT-UP ALUMINUM PROFILE 0.125" BREAK METAL ALUMINUM PANEL BUILT-UP ALUMINUM PROFILE INSULATION STOP TYPICAL COMPOSITE ROOF DECK STL. BEAM, REFER TO STRUCTURAL 3 COURSES 8" CMU, REFER TO STRUCTURAL SPRAY APPLIED FIRE RESISTIVE MATERIAL (N.I.C) ROOFING MEMBRANE VAPOR BARRIER DRYWALL (N.I.C.) TUBE STEEL HEADER, REF. TO S-SERIES DWGS STOREFRONT WINDOW SYSTEM BUILT UP, ALUMINUM CLAD CORNICE SYSTEM C.I.P. CONCRETE BEAM, REFER TO STRUCTURAL EXISTING CONC. STRUC. & SLAB AS SHOWN (FIELD VERIFY) EXISTING CONC STRUC & SLAB AS SHOWN (FIELD VERIFY) EIFS VENEER SECOND FLOOR TOP OF SLAB LOWER RETAIL FLOOR T.O.W. BOT OF STEEL HEIGHT VARIES TOP OF SLAB FUTURE SLAB N.I.C., REFER TO S-SERIES DWGS EPS FOAM N.I.C. DRYWALL N.I.C. INSULATED CFS HEADER AT STOREFRONT WINDOW HEADER, TO BE FIELD BUILT TO ALLOW ATTACHMENT OF TOP TRACK TO C.I.P. CONC. BEAM, REF S-SERIES DWGS 8" CFS INSULATED BULKHEAD R.6 3 AA554 2 AA554 1 AA554 +21'-4" +20'-0" +2'-0" ±0'-0" -13'-0" 13'-0" 2'-0" VARIES VARIES 1'-4" 1'-0" HEIGHT VARIES EXISTING CONC STRUC & SLAB AS SHOWN (FIELD VERIFY) 2-1/4" AIR SPACE BUILT UP ALUMINUM CORNICE PREFINISHED METAL COPING 8" CFS STUD WALL W/ 5/8" DENS GLASS SHEATHING T.O.W. SECOND FLOOR STL. BEAM, REFER TO STRUCTURAL SPRAY APPLIED FIRE RESISTIVE MATERIAL (N.I.C) 5/8" DENS GLASS ROOFING MEMBRANE INSULATION STOP TYPICAL COMPOSITE ROOF DECK T.O. SLAB T.O. SLAB PARKING LEVEL BATT INSULATION FUTURE SLAB N.I.C. REF. TO S-SERIES DRAWINGS EPS FOAM N.I.C. LIQUID APPLIED WATER PROOFING, N.I.C. C.I.P. CONCRETE BEAM, REF. TO STRUCTURAL EXISTING CONC STRUC & SLAB AS SHOWN (FIELD VERIFY) 7/8" AIRSPACE 2-1/4" AIR SPACE 3 COURSES CMU, REF. TO STRUCTURAL WEATHER BARRIER 3/4" EIFS VENEER T.O. STEEL RIGID INSUL. WEATHER BARRIER R.6 6 -13'-0" AA554 ±0'-0" +2'-0" HEIGHT VARIES +20'-0" +21'-4" 13'-0" 2'-0" VARIES 1'-4" 2'-10" DRYWALL (N.I.C.) VAPOR BARRIER TYPICAL COMPOSITE ROOF DECK ROOFING MEMBRANE 8" METAL STUD WALL W / 5/8" EXTERIOR SHEATHING BRICK VENEER STL. BEAM, REF. TO S- SERIES DWGS 2 1/4" AIR SPACE FULL HEIGHT OF WALL 8" METAL STUD WALL W / 5/8" EXTERIOR SHEATHING 2 1/4" AIR SPACE FULL HEIGHT OF WALL EXISTING CONC STRUC & SLAB AS SHOWN (FIELD VERIFY), REF. TO S- SERIES DWGS 3 COURSES 8" CMU, REF. TO S-SERIES DWGS BATT INSULATION SPRAY APPLIED FIRE RESISTIVE MATERIAL (N.I.C) BRICK VENEER PREFINISHED METAL COPING INSULATION STOP BATT INSULATION EPS FOAM N.I.C. FUTURE SLAB N.I.C., REFER TO S-SERIES DWGS ALUMINUM CLAD BAY BEYOND ALUMINUM CLAD BAY BEYOND 3/4" EIFS VENEER ALUMINUM CLAD CORNICE BEYOND SELF LEVELING GROUT (SEE STRUC) EXISTING CONC STRUC & SLAB AS SHOWN (FIELD VERIFY) BUILT UP ALUMINUM CORNICE SECOND FLOOR T.O.SLAB LOWER RETAIL FLOOR T.O.W. DRYWALL N.I.C. T.O.STEEL T.O.SLAB VARIES SIM. PAINTED MTL RAILING BEYOND 8" CFS INSULATED BULKHEAD SCALE: 3/8" = 1'-0" 3 WALL SECTION 3 AA327 0 2' 4' 6' SCALE: 3/8" = 1'-0" 2 WALL SECTION 2 AA327 0 2' 4' 6' SCALE: 3/8" = 1'-0" 1 WALL SECTION 1 AA327 0 2' 4' 6' SCALE: 3/8" = 1'-0" 4 WALL SECTION 4 AA327 0 2' 4' 6' A300C.2 12/17/08 CDB LGA, JAW See sheets AA125 for plan information, AA211 for elevation information 06.29.09