Loading...
HomeMy WebLinkAboutAA341 WALL SECTIONS EAST AREA B 24-26Project: Developer: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: By: Sheet Title: CARMEL CITY CENTER Carmel, Indiana Building A Phase 1 COPYRIGHT & OWNERSHIP OF DOCUMENTS Architecture / Project Management: Project Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue Date PEDCOR DESIGN GROUP LLC 0502.00 AA341 WALL SECTIONS EAST AREA B 24-26 Bid Set !"#!$#%& THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP,LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP,LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP,LLC. © COPYRIGHT 2006, 2007, 2008 JAMES R. STUTZMAN, AIA, CARMEL, INDIANA 37 CCC.A.ASI.11, 9/18/09 !"#$%&’()! !"#$%$&’() !" !! #$ % & ’()’*’ ’()’*+ ’()’*, ( !"#$%&’( )&*+$’ 37 38 37 17 AA701 #DrgID #LayID +97'-3" FOURTH FLOOR FIFTH FLOOR SIXTH FLOOR SEVENTH FLOOR ROOF 6" CFS STUDS MTL COPING WEATHER BARRIER OVER 5/8" EXT. SHEATHING EIFS CORNICE AND BRACKETS EIFS VENEER MTL CAP EIFS CORNICE ALUM. WINDOW EIFS VENEER WATERPROOF COATING VAPOR BARRIER VAPOR BARRIER INSULATED HEADER BEAM-REFER TO S-SERIES DRAWINGS WATERPROOF COATING EIFS VENEER 1 1/2" TOPPING SLAB (NIC) INSULATED HEADER BEAM-REFER TO S-SERIES DRAWINGS STEEL COLUMN BEYOND ADJACENT FACADE BEYOND MTL COPING EIFS VENEER EIFS DETAIL PROFILE WEATHER BARRIER OVER 5/8" EXT. SHEATHING BATT INSULATION 6" CFS STUDS MTL CAP EIFS CORNICE EIFS BRACKET SLIDING ALUM. DOOR MTL COPING ADJACENT FACADE BEYOND EIFS CORNICE EIFS BRACKET MTL CONDUCTOR HEAD MTL DOWNSPOUT EIFS VENEER MTL CAP EIFS BRACKET SLIDING ALUM. DOOR PAINTED MTL RAILING EIFS PROFILE BAND MTL EXHAUST HOOD REFER TO FIFTH FLOOR FOR TYPICAL NOTES EIFS EXPANSION JOINT EIFS TRIM EIFS EXPANSION JOINT Q #DrgID #LayID +20'-0" SECOND FLOOR REFER TO FIFTH FLOOR FOR TYPICAL NOTES MEMBRANE ROOFING OVER 3" RIGID INSUL. 4 AA701 3 AA703 14'-6 7/8" 1'-5 1/8" 16'-0" MTL COPING DORMER BEYOND-REFER TO SECTION 3/AA341 1 1/2" MTL ROOF DECK-REFER TO S-SERIES DRAWINGS WEATHER BARRIER OVER 5/8" EXT. SHEATHING 2 1/4" AIR SPACE ROOF TRUSSES-SEE SHEET AA514 STONE HEAD TRIM & SURROUND BRICK VENEER ALUM. WINDOW STONE BAND MTL EXHAUST VENT REFER TO SIXTH FLOOR FOR TYPICAL NOTES REFER TO SIXTH FLOOR FOR TYPICAL NOTES EXTEND MTL ROOFING UP ONTO PARAPET MTL RAKE FLASHING SLOPED MTL PARAPET SNOW/ICE GUARDS STANDING SEAM MTL ROOFING BATT INSUL. UP TO TOP OF ROOF DECK INSUL. VAPOR BARRIER 6" CFS STUDS INSULATED HEADER BEAM- REF. S-SERIES DRAWINGS. BATT INSULATION VAPOR BARRIER SIM. MTL. GUTTER (DOWNSPOUT BEYOND) RIGID BOARD FIRE PROTECTION MTL. CAP CFS BOX HEADER W/ SHEATHING, EIFS FASCIA & SOFFIT STONE SILL REF. TO 4/AA704 FOR FIRE RATED ROOF ASSEMBLY REF. TO 9/AA704 FOR ROOF ASSEMBLY VENT SPACED 5'-0", BOTTOM OF VENT 1'-0" ABOVE ROOF MEMBRANE. 4" CONTINUOUS SOFFIT VENT UNDER TRIANGLE TRUSSES ONLY Q 2 AA704 MEMBRANE ROOFING OVER 3" RIGID INSUL. REFER TO SIXTH FLOOR FOR TYPICAL NOTES +20.00' 2 Second Floor 10 AA703 Q +83'-6" 11'-3 7/8" 16'-0" 8'-0" 3/4" SHEATHING ALUMINUM WINDOW. SEE SCHEDULE 6" CFS STUDS @ 16" O.C. BETWEEN ROOF TRUSSES INSULATED HEADER BEAM REFERENCE S- SERIES DRAWINGS ROOF TRUSSES BEYOND. SEE SHEET AA514. 6" CFS STUDS @ 16" O.C. BETWEEN ROOF TRUSSES INSULATED HEADER BEAM REFERENCE S- SERIES DRAWINGS ROOF TRUSSES BEYOND. SEE SHEET AA514. TAPERED ROOF INSULATION REFER TO S-SERIES DWGS. FOR BEARING & CONNECTION CONDITIONS OF CFS TRUSSES 6" CFS STUDS @ 16" O.C. BETWEEN ROOF TRUSSES ARCHED CFS ROOF TRUSSES. SEE SHEET AA514. ARCHED TOP CFS STUD WALL BETWEEN ROOF TRUSSES 5/8" ROOF SHEATHING OVER 1 1/2" MTL DECK REFER TO S-SERIES DWGS. FOR METAL ROOF DECK SEE DETAIL 4/AA704 FOR FIRE RATED ROOF ASSEMBLY 3" RIGID INSULATION INSULATED SILL BEAM REFERENCE S-SERIES DRAWINGS ALIGN W/ BTM. OF ARCHED ROOF TRUSSES ALIGN W/ TOP OF ROOF TRUSSES METAL ROOF DECK BEYOND ROOFING MEMBRANE ____" EIFS VENEER WEATHER BARRIER BATT INSULATION BATT INSULATION VAPOR BARRIER STANDING SEAM MTL ROOFING BRICK VENEER SEE DETAIL 4/AA704 FOR FIRE RATED ROOF ASSEMBLY - Q +83'-6" 1'-2 5/8" 11 7/8" 2'-0 3/4" 15'-7 1/2" 4 1/2" 16'-0" INDICATES ROOF TRUSSES FOR REFERENCE. SEE SHEET AA514. REFER TO S-SERIES DWGS. FOR METAL ROOF DECK (SHOWN FOR REFERNCE) SLOPING TOP CFS STUD TRACK OF SLOPING PARAPET WALL 3/4" F.R. PLYWOOD ROOF SHEATHING VERTICAL CFS STUDS OF SLOPING CFS STUD PARAPET WALL COORD. W/ SHEET AA514 MTL COPING MTL PARAPET COPING BATT INSULATION VAPOR BARRIER MEMBRANE ROOFING OVER 3" RIGID INSUL. SIM. SEVENTH FLOOR #DrgID AA703 12'-0" 13'-9" 13'-9" 13'-9" 7 Seventh Floor 24'-0" 12'-0" 13'-9" 13'-9" 13'-9" FOURTH FLOOR FIFTH FLOOR SIXTH FLOOR SEVENTH FLOOR ROOF 24'-0" +44.00' 4 Fourth Floor +56.00' 5 Fifth Floor +69.75' 6 Sixth Floor +83.50' 7 Seventh Floor +97.25' 8 Roof Q 2 1/2" 2 1/2" 4"-6" 3 1/2" 42" 1" EIFS VENEER MTL COPING EIFS BRACKET BEYOND MTL CONDUCTOR HEAD MTL DOWNSPOUT CFS STUD WALL EIFS VENEER EIFS VENEER SHEATHING PORCH CONC. SLAB SIKA, DECOTHANE BALCONS LIQ. COATING SYSTEM PREFINISHED BREAK METAL FLASHING FLANGE ALL FOUR SIDES 0.300" POWER- ACTUATED FLUSH PINS @ 12" O.C. BEAD SEALANT, CONT. SIKA 15ML POLYURETHANE MILL FINISH (BARE) GALVALUME FLASHING SIKA, DECOTHANE BALCONS LIQ. COATING SYSTEM APPLIED TO THE EDGE OF FLASHING SCUPPER, PREFINISHED METAL TURN UP SIKA DECOTHANE BALCONS & MILL FINISH (BARE) GALVALUME FLASHING BEAD SEALANT, CONT. SIKA 15ML POLYURETHANE GAURDRAIL VERTICAL BEYOND SCALE: 3/8" = 1'-0" 1 WALL SECTION E.25-26 AA341 0 2' 4' 6' SCALE: 3/8" = 1'-0" 2 WALL SECTION E.24-25 AA341 0 2' 4' 6' SCALE: 3/8" = 1'-0" 3 SECTION DETAIL 7TH FLOOR AA341 0 2' 4' 6' SCALE: 3/8" = 1'-0" 4 SECTION DETAIL 7TH FLOOR E.24-25 AA341 0 2' 4' 6' SCALE: 1" = 1'-0" 4 SCUPPER DETAIL AA341 0 6'' 1' 2' 12.29.08 BAB BAB, JAW A.300, A.305B, A.310B 09/18/09