Loading...
HomeMy WebLinkAboutAA411 Elevator Plans & SectionsProject: Developer: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: By: Sheet Title: CARMEL CITY CENTER Carmel, Indiana Building A Phase 1 COPYRIGHT & OWNERSHIP OF DOCUMENTS Architecture / Project Management: Project Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue Date PEDCOR DESIGN GROUP LLC 0502.00 AA411 Elevator Plans & Sections 03.29.07 THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP,LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP,LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP,LLC. © COPYRIGHT 2006, 2007, 2008 JAMES R. STUTZMAN, AIA, CARMEL, INDIANA BID SET A.410 ISSUE, 12/29/08 SCALE: NTS PLAN NORTH 28 22 16 H M AREA A AREA C AREA B R KEY PLAN BLDG A Monday, December 29, 2008; alldata:MS:DESIGN:PROJECTS:CARMEL CITY CENTER:CCC Drawings:CCC Construction Doc:Building A:A.200:A.200 Main sheets.pln 14 Q P.5 12 9 AA414 1 AA501 9 AA501 11 AA414 12'-0" 12'-0" 12'-0" 12'-0" 15'-6" 13'-9" 8'-103/8" 5'-0" MIN. 18'-10" SLOPED PIT FLOOR REF. STRUCTURAL EA5 ELEVATOR WATERPROOFING COORDINATE SUMP PIT LOCATION W/ ELEVATOR MANUFACTURER, PROVIDE STEEL GRATE COVER & FRAME WATERPROOFING TYP. AAC LADDERS BY ELEVATOR MANUFACTURER LINTEL, REF. S- SERIES DRAWINGS, TYPICAL HOISTWAY BEAM, REFERENCE S- SERIES DRAWINGS ELEVATOR EQUIPMENT, COORDINATE CABLE HOLE & BEAM LOCATION WITH MANUFACTURER HOISTWAY VENTING 8" CMU 8'-3" MIN LINTEL, REF. S- SERIES DRAWINGS WALL AND ROOF DETAILS: IN FUTURE A.300 SERIES BID SETS. METAL STAIR AND RAILING SYSTEM BEYOND. NOTE: REFERENCE S-SERIES DRAWINGS FOR BOND BEAM REQUIREMENTS IN CMU WALLS. NOTE: SHAFT LINER WALLS FROM 2ND FLOOR TO UNDER SIDE OF ROOF; 6" CH STUD SYSTEMS. SCALE: 1/4" = 1'-0" 3 ELEVATOR EA5 N/S SHAFT SECTION AA411 0 2' 4' 8' 12 12 AA505 5'-0" min. 18'-10" 18'-11/2" 12'-0" 12'-0" 12'-0" 13'-9" 13'-9" 15'-2" 8'-815/16" ELEVATOR ELEVATOR EA5 EA4 WATERPROOFING HIGHEST POINT OF SLOPED PIT FLOOR LADDERS BY ELEVATOR MANUFACTURER EL. = EL. = EL. = EL. = EL. = EL. = HOISTWAY BEAM, REFERENCE S- SERIES DRAWINGS ELEVATOR EQUIPMENT, COORDINATE CABLE HOLE & BEAM & BEAMLOCATION WITH MANUFACTURER EL. = EL. = EL. = EL. = 8" CMU NOTE: REFERENCE S-SERIES DRAWINGS FOR BOND BEAM REQUIREMENTS IN CMU WALLS. NOTE: SHAFT LINER WALLS FROM 2ND FLOOR TO UNDER SIDE OF ROOF; 6" CH STUD SYSTEMS. TYP. -3'-1" Plaza Sandwich +2'-0" First Floor +20'-0" Second Floor +32'-0" Third Floor +44'-0" Forth Floor +56'-0" Fifth Floor & Roof +69'-9" Sixth Floor +83'-6" Seventh Floor +97'-3" Eighth Floor Roof +109'-3" Ninth Floor Roof SCALE: 1/4" = 1'-0" 1 ELEVATOR EA4/5 E/W SHAFT SECTION AA411 0 2' 4' 8' 24 P.5 Q 2 AA411 4 AA411 3 - AA411 - 41/2" 5'-3" 2'-71/2" 6" 1'-101/2" 4'-9" 1'-101/2" 1'-4" 17'-3" 75/8" 93/8" 1'-4" 17'-3" 1'-5" ELEVATOR EA5 VERIFY W/ ELEVATOR MANF. M.O. WIDTH, HEIGHT, & LOCATION ELEVATOR EA4 STEEL BEAMS, REF. S- SERIES DRAWINGS 8" CMU EL.: -16'-10" EL. = EL. = EL. = EL. = EL. = EL. = EL. = EL. = EL. = EL. = -3'-1" Plaza Sandwich +2'-0" First Floor +20'-0" Second Floor +32'-0" Third Floor +44'-0" Forth Floor +56'-0" Fifth Floor & Roof +69'-9" Sixth Floor +83'-6" Seventh Floor +97'-3" Eighth Floor Roof +109'-3" Ninth Floor Roof EL.: -16'-10" EL. = EL. = EL. = EL. = EL. = EL. = EL. = EL. = EL. = EL. = -3'-1" Plaza Sandwich +2'-0" First Floor +20'-0" Second Floor +32'-0" Third Floor +44'-0" Forth Floor +56'-0" Fifth Floor & Roof +69'-9" Sixth Floor +83'-6" Seventh Floor +97'-3" Eighth Floor Roof +109'-3" Ninth Floor Roof 23.6 24 23.6 24 12 9 AA414 1 AA501 11 AA414 9 AA501 12 AA505 8'-103/8" 5'-0" min. 18'-10" WATERPROOFING WATERPROOFING COORDINATE SUMP PIT LOCATION W/ ELEVATOR MANUFACTURER, PROVIDE STEEL GRATE COVER & FRAME ELEVATOR SHAFT EA4 TYP. AAC LADDERS BY ELEVATOR MANUFACTURER LINTEL, REF. S- SERIES DRAWINGS, TYPICAL HOISTWAY BEAM, REFERENCE S- SERIES DRAWINGS ELEVATOR EQUIPMENT, COORDINATE CABLE HOLE & BEAM & BEAMLOCATION WITH MANUFACTURER HOISTWAY VENTILATION DUCT, REFERENCE MECHANICAL DRAWINGS LINTEL, REF. S- SERIES DRAWINGS 8'-3" MIN 8" CMU WALL AND ROOF DETAILS: IN FUTURE A.300 SERIES BID SETS. NOTE: REFERENCE S-SERIES DRAWINGS FOR BOND BEAM REQUIREMENTS IN CMU WALLS. NOTE: SHAFT LINER WALLS FROM 2ND FLOOR TO UNDER SIDE OF ROOF; 6" CH STUD SYSTEMS. TYP. SCALE: 1/4" = 1'-0" 2 ELEVATOR EA4 N/S SHAFT SECTION AA411 0 2' 4' 8' ELEV. EA4/5 PARKING LEVEL PLAN STRUCTURAL NOTE: Not all strucutral coordination is complete from first floor to the roof. There wiil be rail attachemtn not more than 12' o.c., concrete slb for the roof machine rooms, and hoists beams at all shafts. NOTE: THE 5TH, 6TH AND 7TH FLOORS WILL ALL BE 13'-9" FLOOR TO FLOOR. THIS AFFECTS ONLY ELEVATORS EA4 AND EA5. 4.27.07 jdr, jaw jaw Bid Set A.200,A.210,A.400 12-29-08