Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
AA504 FIRE PROOFING DETAILS
Project: Developer: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: By: Sheet Title: CARMEL CITY CENTER Carmel, Indiana Building A Phase 1 COPYRIGHT & OWNERSHIP OF DOCUMENTS Architecture / Project Management: Project Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue Date PEDCOR DESIGN GROUP LLC 0502.00 AA504 FIRE PROOFING DETAILS Bid Set 04.21.06 THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP,LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP,LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP,LLC. © COPYRIGHT 2006, 2007, 2008 JAMES R. STUTZMAN, AIA, CARMEL, INDIANA 25 26 27 28 BID SET A.410 ISSUE, 12/29/08 BID SET A.210.ASI.01, 01/20/09 (AFFECTING A.300, A.310, A.400) WINDOW SCHEDULE UPDATE, 2/02/09 BID SET A.300, 02/07/09 MASONRY AND EIFS UPDATE BID SET A.300, 02/27/09 MASONRY AND EIFS UPDATE 2 A.300.ASI.004, 03/08/09 E R 28 22 16 H 11 SCALE: NTS PLAN NORTH KEY PLAN 2" 31/2" SPRAYED-APPLIED FIRE PROOFING FIRE-STOPPING (CAULK) AAC OR CMU WALL. TOP OF BELOW BEAM 1/2" MIN. 1 AND 2 HOUR RATED FRAMING AND FLOOR ASSEMBLY UL DESIGNS WITH VULCRAFT DECK 2VLI AND THE FOLLOWING SPRAY-APPLIED FIRE RESISTIVE MATERIALS: ISOLATEK CAFCO BLAZE SHIELD II: D902 - FOR DECK ASSEMBLY, N823 – FOR BEAMS ONLY STEEL ANGLES, REF S- SERIES DRAWINGS UNRESTRAINED DESIGN NORMAL WEIGHT CONCRETE AT 1 HOUR ASSEMBLIES AND LIGHTWEIGHT CONCRETE AT 2 HOUR ASSEMBLIES. 6x6 - w2.1 x w2.1 WWF 11/2" greater than 2-1/2" SPRAYED-APPLIED FIRE PROOFING 1 AND 2 HOUR RATED FRAMING AND FLOOR ASSEMBLIES AT INTERIOR BALCONIES WITH SLOPED CONCRETE UL DESIGNS WITH VULCRAFT DECK 2VLI AND THE FOLLOWING SPRAY-APPLIED FIRE RESISTIVE MATERIALS: ISOLATEK CAFCO BLAZE SHIELD II: D858 – FOR 2 HOUR DECK ASSEMBLY, D832 - FOR 1 AND 2 HOUR ASSEMBLY, N823 – FOR BEAMS ONLY 6x6 - w2.1 x w2.1 WWF UNRESTRAINED DESIGN <2" >2" SPRAYED-APPLIED FIRE PROOFING CMU & AAC AT RATED WALL 1 AND 2 HOUR RATED COLUMN ASSEMBLY WHERE RATED CMU &AAC WALL ENGAGES COLUMN AT FLANGE MASONRY ANCHOR, REFERENCE S-SERIES DRAWINGS WIRE LATHE PER U.L. REQUIREMENTS UL DESIGNS USING THE FOLLOWING SPRAY-APPLIED FIRE RESISTIVE MATERIALS: ISOLATEK CAFCO BLAZE SHIELD II - X829 <2" >2" SPRAYED-APPLIED FIRE PROOFING CMU & AAC AT RATED WALL 1 AND 2 HOUR RATED COLUMN ASSEMBLY WHERE RATED CMU & AAC WALL ENGAGES COLUMN AT WEB MASONRY ANCHOR, REFERENCE S-SERIES DRAWINGS WIRE LATHE PER U.L. REQUIREMENTS UL DESIGNS USING THE FOLLOWING SPRAY-APPLIED FIRE RESISTIVE MATERIALS: ISOLATEK CAFCO BLAZE SHIELD II - X829 INTUMESCENT PAINT AT AAC WALL: INTUMESCENT PAINT ON EXPOSED SURFACES OF BEAM ONLY. AT CFS WALL: INTUMESCENT PAINT ON ALL SURFACES OF BEAM . 1 AND 2 HOUR RATED ASSEMBLY WHERE AAC WALL ENGAGES BEAM UL DESIGNS USING THE FOLLOWING SPRAY-APPLIED FIRE RESISTIVE MATERIALS: CAFCO N614 SPRAYED-APPLIED FIRE PROOFING AAC WALL 1 AND 2 HOUR RATED ASSEMBLY WHERE AAC WALL ENGAGES BEAM UL DESIGNS USING THE FOLLOWING SPRAY-APPLIED FIRE RESISTIVE MATERIALS: CAFCO N823 <2" >2" SPRAYED-APPLIED FIRE PROOFING CMU AT RATED WALL 1 AND 2 HOUR RATED COLUMN ASSEMBLY WHERE CMU AT RATED WALL/PILASTER ENGAGES COLUMN AT FLANGE MASONRY ANCHOR, REFERENCE S-SERIES DRAWINGS 4" BULL NOSED CMU AT RATED WALL WIRE LATHE PER U.L. REQUIREMENTS UL DESIGNS USING THE FOLLOWING SPRAY-APPLIED FIRE RESISTIVE MATERIALS: ISOLATEK CAFCO BLAZE SHIELD II - X829 2" SPRAYED-APPLIED FIRE PROOFING NON RATED CMU & AAC WALL 1 AND 2 HOUR RATED COLUMN ASSEMBLY WHERE NON-RATED CMU & AAC WALL BY PASSES COLUMN APPROVED CAULK NOTE: SFRM IS REQUIRED TO BE INSTALLED PRIOR TO MASONRY WALL WORK WHEN WALL IS NON- RATED. SEE LIFE SAFETY DRAWINGS. TYP. UL DESIGNS USING THE FOLLOWING SPRAY-APPLIED FIRE RESISTIVE MATERIALS: ISOLATEK CAFCO BLAZE SHIELD II - X829 VAPOR RETARDER 5/8" GYPSUM BOARD N.I.C. VAPOR RETARDER METAL STUDS @ 16" O.C. E.O.S. REF TO S- SERIES DWGS E.O.S. REF TO S- SERIES DWGS 5/8" EXTERIOR SHEATHING NOTCH STUD TRACK WHERE REQUIRED FOR COLUMN FLANGES SPRAY APPLIED FIRE RESISTIVE MATERIAL, REF TO A210 SERIES DWGS REDUCTION OF CFS STUD FRAMING SIZE PERMITTED ONLY AT COLUMNS WHERE TYPICAL SPACING OF STUDS CANNOT BE ACHIEVED TO ALLOW FOR PROPER APPLICATION OF FIREPROOFING, REDUCED STUDS MUST BE ATTACHED TO COLS. CFS STUD FRAMING THAT MAKES CONTACT WITH COLUMNS, TO BE ATTACHED AND SPRAYED W/ FIRE-RESISTIVE MATERIAL AT SAME TIME AS COLUMN 1 AND 2 HOUR RATED FRAMING ASSEMBLY WHERE EXTERIOR WALL BY PASSES COLUMN @ CORNER CFS STUD CONFIGURATION 2 SPRAY APPLIED FIRE RESISTIVE MATERIAL 5/8" GYPSUM BOARD N.I.C. VAPOR RETARDER E.O.S. REF TO S- SERIES DWGS E.O.S. REF TO S- SERIES DWGS 5/8" EXTERIOR SHEATHING WEATHER BARRIER METAL STUDS @ 16" O.C. CFS STUD FRAMING THAT MAKES CONTACT WITH COLUMNS, TO BE ATTACHED AND SPRAYED W/ FIRE-RESISTIVE MATERIAL AT SAME TIME AS COLUMN 1 AND 2 HOUR RATED FRAMING ASSEMBLY WHERE EXTERIOR WALL BY PASSES COLUMN @ CORNER CFS STUD CONFIGURATION 1 REDUCTION OF CFS STUD FRAMING SIZE PERMITTED ONLY AT COLUMNS WHERE TYPICAL SPACING OF STUDS CANNOT BE ACHIEVED TO ALLOW FOR PROPER APPLICATION OF FIREPROOFING, REDUCED STUDS MUST BE ATTACHED TO COLS. SPRAYED-APPLIED FIRE PROOFING NON RATED CMU & AAC WALL 1 AND 2 HOUR RATED COLUMN ASSEMBLY WHERE NON-RATED CMU & AAC WALL BY PASSES COLUMN NOTE: SFRM IS REQUIRED TO BE INSTALLED PRIOR TO MASONRY WALL WORK WHEN WALL IS NON- RATED. SEE LIFE SAFETY DRAWINGS. UL DESIGNS USING THE FOLLOWING SPRAY-APPLIED FIRE RESISTIVE MATERIALS: ISOLATEK CAFCO BLAZE SHIELD II - X829 25/8" 1" GYPSUM BOARD PER UL DIRECTORY 1 AND 2 HOUR RATED DRYWALL ASSEMBLY AT COLUMNS STEEL STUDS PER UL DIRECTORY UL DESIGN NO. X518 INTERIOR PARTITION ATTACHED TO THE OUTSIDE OF RATED COLUMN ASSEMBLY NOTHING IS ALLOWED TO PENETRATE OR INTERFERE WITH RATED COLUMN ASSEMBLY AND/OR INSIDE THIS LINE. APPROX. APPROX. ADDITIONAL STUDS AS REQUIRED FOR FASTENING OF MASONRY ANCHORS, MASON AND STUD FRAMER TO COORDINATE STUD LOCATIONS 3" 3" 1'-4" 2" MIN. 5/8" VARIES WHERE FACE OF STUD TO COLUMN CENTER LINE IS LESS THAN 1'-0 1/4", THEN USE UL DESIGNS X518 AND X536. EXTERIOR METAL STUD WALL 1 AND 2 HOUR RATED FRAMING ASSEMBLY WHERE EXTERIOR WALL BY PASSES COLUMN UL DESIGNS USING THE FOLLOWING SPRAY-APPLIED FIRE RESISTIVE MATERIALS: ISOLATEK CAFCO BLAZE SHIELD II - X829 MAX. MAX. ADDITIONAL METAL STUD FOR INTERIOR SHEATHING FRAMING TRACK FOR RATED WALL ASSEMBLY, DECREASE STUD SIZE AND BYPASS SFRM PROTECTED COLUMN WITH THE RATED WALL ASSEMBLY. EXCEPTION: WHEN THE FLOOR PLANS REFERENCE DETAILS USING UL X536 OR X518, DO NOT BY-PASS COLUMN, BUT TERMINATE WALL AT BOTH SIDES OF COLUMN WRAP SHOWN IN THOSE DESIGNS. UL DESIGNS X536 OR X518 CAN BE USED AS A SUBSTITUTION FOR SFRM IF BY-PASSING THE COLUMN ASSEMBLY IS NOT POSSIBLE WITH A RATED WALL ASSEMBLY. 5/8" 1" 11/2" 5/8" COLUMN WRAP W/ SNAP ON CLIPS CODE REQUIREMENTS FOR GYPSUM BOARD INSTALLATION "CLIP" THE CLAW TO STRUCTURAL MEMBERS 1 (TOP, BOTTOM, AND EVERY 4 FEET) SCREW CORNER BEAD TO CLIP 2 SCREW GYPSUM BOARD TO CORNER BEAD 3 INSTALL FINISH CORNER BEAD 4 REQUIRED BY CODE MULTIPLE LAYERS IF "THE CLAW" 1 GYPSUM BOARD SCREWS 2 & 3 (TYPICAL) CORNER BEAD 2 GYPSUM BOARD 3 CORNER BEAD 4 STRUCTURAL MEMBER GYPSUM BOARD PER UL DIRECTORY. 1 LAYER FOR 1 HOUR AND 2 LAYERS FOR 2 HOURS. 1 AND 2 HOUR RATED DRYWALL ASSEMBLY AT COLUMNS UL DESIGN NO. X536 INTERIOR PARTITION ATTACHED TO THE OUTSIDE OF RATED COLUMN ASSEMBLY NOTHING IS ALLOWED TO PENETRATE OR INTERFERE WITH RATED COLUMN ASSEMBLY AND/OR INSIDE THIS LINE. HIGH "THE CLAW" GALVANIZED 2" DEEP BY 2 3/8" WIDE BY 2" STEEL CLIPS SPACED 4 FT. O.C. AND 1 1/4" FROM TOP AND BOTTOM OF COLUMN. APPROX. APPROX. ADDITIONAL STUDS AS REQUIRED FOR FASTENING OF MASONRY ANCHORS, MASON AND STUD FRAMER TO COORDINATE STUD LOCATIONS >2" >2" SPRAYED-APPLIED FIRE PROOFING CMU & AAC AT NON- RATED WALL 1 AND 2 HOUR RATED COLUMN ASSEMBLY WHERE NON- RATED CMU & AAC WALL ENGAGES COLUMN AT WEB MASONRY ANCHOR, REFERENCE S-SERIES DRAWINGS UL DESIGNS USING THE FOLLOWING SPRAY-APPLIED FIRE RESISTIVE MATERIALS: ISOLATEK CAFCO BLAZE SHIELD II - X829 2" SPRAYED-APPLIED FIRE PROOFING NON RATED CMU & AAC WALL 1 AND 2 HOUR RATED COLUMN ASSEMBLY WHERE NON-RATED CMU & AAC WALL BY PASSES COLUMN UL DESIGNS USING THE FOLLOWING SPRAY-APPLIED FIRE RESISTIVE MATERIALS: ISOLATEK CAFCO X314 APPROVED CAULK RIGID BOARD 2" SPRAYED-APPLIED FIRE PROOFING 1 HOUR RATED FRAMING AND ROOF ASSEMBLY (NO CONCRETE DECK ABOVE) UL DESIGNS WITH 1-1/2" DECK AND THE FOLLOWING SPRAY-APPLIED FIRE RESISTIVE MATERIALS: IISOLATEK CAF CO BLAZE SHIELD II: P819 UNRESTRAINED DESIGN FOAM ROOF INSULATION WITH ROOF MEMBRANE ABOVE. 2" 31/2" SPRAYED-APPLIED FIRE PROOFING FIRE-STOPPING (CAULK) AAC OR CMU WALL. HOLD TOP OF WALL BELOW BEAM 1/2" MIN. 2 HOUR RATED FRAMING AND FLOOR ASSEMBLY STEEL ANGLES, REF S- SERIES DRAWINGS UNRESTRAINED DESIGN NORMAL WEIGHT CONCRETE 6x6 - w2.1 x w2.1 WWF UL DESIGNS WITH VULCRAFT DECK 2VLI AND THE FOLLOWING SPRAY-APPLIED FIRE RESISTIVE MATERIALS: ISOLATEK CAFCO BLAZE SHIELD II: D858 – FOR DECK ASSEMBLY, N823 – FOR BEAMS ONLY 8" 2" 2" 8" TYP. ADJACENT WALL ASSEMBLIES. SPRAYED APPLIED FIRE PROOFING. FULL HEIGHT STUD WALL. TYP. 03.03.08 JAW JAW 28 28 NOT TO SCALE 8 Detail AA504 NOT TO SCALE 4 Detail AA504 NOT TO SCALE 6 Detail AA504 NOT TO SCALE 2 Detail AA504 NOT TO SCALE 7 Detail AA504 NOT TO SCALE 3 Detail AA504 NOT TO SCALE 10 Detail NOT TO SCALE AA504 18 Detail AA504 NOT TO SCALE 11 Detail NOT TO SCALE AA504 15 Detail AA504 NOT TO SCALE 14 Detail AA504 NOT TO SCALE 9 Detail NOT TO SCALE AA504 17 Detail AA504 NOT TO SCALE 13 Detail AA504 NOT TO SCALE 1 Detail NOT TO SCALE AA504 5 Detail AA504 NOT TO SCALE 16 Detail AA504 NOT TO SCALE 12 Detail AA504 NOT TO SCALE 19 Detail AA504 A.210,A300C.1,A.400 10.24.08