Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
AA509 Wall Sections
4/5/10 3:45 PM; ASI 23 Project: Developer: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: By: Sheet Title: CARMEL CITY CENTER Carmel, Indiana Building A Phase 1 COPYRIGHT & OWNERSHIP OF DOCUMENTS Architecture / Project Management: Project Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue Date PEDCOR DESIGN GROUP LLC 0502.00 AA509 Wall Sections Bid Set 04.21.06 THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP,LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2006, 2007, 2008, 2009, JAMES R. STUTZMAN, AIA, CARMEL, INDIANA 44 42 CCC.A.ASI.23, 04/01/10 CCC.A.ASI.18, 03/29/10 REVISED MAILBOX CONFIGURATION E R 28 22 16 H 11 SCALE: NTS PLAN NORTH KEY PLAN VARIES THREE COURSES OF C.M.U. STRUCTURAL DECK OVER PARKING LEVEL FLUSH FACE OF STUD TO C.M.U. REFERENCE S-SERIES DRAWINGS FOR C.M.U. AND SLAB REQUIREMENTS RETAIL SIDE PUBLIC PASSAGE LIQUID APPLIED WATERPROOF MEMBRANE RIGID INSULATION EXTERIOR SHEATHING PAVERS, N.I.C. 1/2" SEPARATION W/ SEALANT RETAIL / PUBLIC PASSAGE WALLS WATERPROOF MEMBRANE, N.I.C. 2'-0" 2 AA509 REFERENCE S-SERIES DRAWINGS FOR JOINT THREE COURSES OF C.M.U. REQUIREMENTS STRUCTURAL DECK OVER PARKING LEVEL SHEATHING 1/2" SEPARATION W/ SEALANT BETWEEN SHEATHING AND TOP OF BLOCK. ELEVATION 2'-0" 1'-2" 1" TWO COURSES OF C.M.U. STRUCTURAL DECK OVER PARKING LEVEL FLUSH FACE OF STUD W/ SLAB REFERENCE S-SERIES DRAWINGS FOR C.M.U. RETAIL SIDE SERVICE CORRIDOR WATERPROOF MEMBRANE RIGID INSULATION SEE SPECIFICATIONS FOR SHEATHING @ SERVICE CORRIDOR 1/2" SEPARATION W/ SEALANT RETAIL / SERVICE CORRIDOR WALLS 2x10 TREATED OAK CONTINUOUS BUMP RAIL, ON RUBBER SPACERS CL 2X12 WOOD BLOCKING 8x8 RUBBER SPACER 4" CONC. SLAB TURNED DOWN OVER C.M.U., 6x6-W2.1 x W2.1 WWF WITH SAME CONTROL JOINT SPACING AS SPECIFIED FOR THE SLAB ON GRADE IN THE RETAIL SPACES. 3" 3" 16 GAUGE GALV. SHT. MTL. COLUMN PROTECTOR. TOP @ 8'-0" A.F.F. ALL EDGES SHALL BE FOLDED @ TOP, BOTTOM AND SIDES. WOOD BLOCKING @ STUD PARTITIONS SPRAY APPLIED FIRE PROTECTION STEEL COLUMN ANCHORAGE : REF. S-SERIES DRAWINGS FOR FASTENING METHODS TO C.M.U. OR STUD WALL. PLAN 8'-0" 1 1/2" x 1 1/2" x 1/4" ANGLE ALONG 3 SIDES WELDED @ CORNERS SHT. MTL. MACHINE BOLT THREADED INTO ANGLES ( NO NUTS). FASTEN BOTTOM ANGLES TO FLOOR SECTION 6" 6" 1'-9 3/4" ONE COURSE OF C.M.U. (SOLID) AROUND COLUMN BASE AND PLUMBING PENETRATIONS . STRUCTURAL DECK OVER PARKING LEVEL WATERPROOF MEMBRANE RIGID INSULATION CONCRETE SLAB SPRAY-APPLIED FIRE RESISTIVE MATERIAL INFILL WITH PEA GRAVEL AT VOIDS BETWEEN RIGID INSULATION AND SFRM REFERENCE PLUMBING BID SETS RATED PIPE PENTRATION ASSEMBLY STRUCTURAL DECK OVER PARKING LEVEL WATERPROOF MEMBRANE RIGID INSULATION CONCRETE SLAB SPRAY-APPLIED FIRE RESISTIVE MATERIAL INFILL WITH PEA GRAVEL AT VOIDS BETWEEN RIGID INSULATION AND SFRM 1/2" J-Mould NON- RATED WALL = BACKER ROD & SEALANT RATED WALL = FIRE SEALANT ASSEMBLY, SEE DETAILS. NOTE: AT DEMISING WALLS, THE CONSTRUCTION MANAGER WILL PROVIDE SCOPE FOR WHICH DRYWALL FACES ARE TO BE INSTALLED. PLAN 2'-0" 3' LONG #5 REBAR @ 24" OC TWO COURSES OF C.M.U., GROUT FILLED. REFERENCE S-SERIES DRAWINGS FOR C.M.U. STRUCTURAL DECK OVER PARKING LEVEL FLUSH FACE OF STUD W/ SLAB RETAIL SIDE WATERPROOF MEMBRANE RIGID INSULATION 1/2" SEPARATION W/ SEALANT DEMISING WALLS RETAIL SIDE 4" CONC. SLAB TURNED DOWN OVER C.M.U., 6x6-W2.1 x W2.1 WWF WITH SAME CONTROL JOINT SPACING AS SPECIFIED FOR THE SLAB ON GRADE IN THE RETAIL SPACES. 2'-0" ONE COURSE OF C.M.U. (SOLID), SEE PLAN FOR LOCATION. STRUCTURAL DECK OVER PARKING LEVEL RETAIL WATERPROOF MEMBRANE RIGID INSULATION CONCRETE SLAB PEA GRAVEL PLUMBING SCALE: 1" = 1'-0" 2 TYPICAL WALL SECTION AA509 0 6'' 1' 2' SCALE: 1" = 1'-0" 1 TYPICAL WALL SECTION AA509 0 6'' 1' 2' SCALE: 3" = 1'-0" 5 COLUMN PROTECTION AA509 0 3'' 6'' 9'' SCALE: 1" = 1'-0" 6 TYPICAL PLAZA WATERPROOFING @ COLUMN AND PIPE AA509 0 6'' 1' 2' SCALE: 1" = 1'-0" 9 TYPICAL PLAZA WATERPROOFING @ COLUMN AA509 0 6'' 1' 2' SCALE: 1 1/2"= 1'-0" 4 CONTROL JOINT @DRYWALL AND C.M.U. PARTITIONS AA509 0 6'' 12'' 18'' SCALE: 1" = 1'-0" 7 DEMISING WALL SECTION AT FLOOR AA509 0 6'' 1' 2' SCALE: 1" = 1'-0" 8 PLUMBING at CONTINUOUS SLAB AA509 0 6'' 1' 2' A.210,A.400 03.03.08 RJP JAW 04.01.10 44 44 44 44