Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
AA566 DETAILS AREA A H-J
44 42 CCC.A.ASI.23, 05/20/10 CCC.A.ASI.18, 03/29/10 REVISED MAILBOX CONFIGURATION Project: Developer: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: By: Sheet Title: CARMEL CITY CENTER Carmel, Indiana Building A Phase 1 COPYRIGHT & OWNERSHIP OF DOCUMENTS Architecture / Project Management: Project Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue Date PEDCOR DESIGN GROUP LLC 0502.00 AA566 DETAILS AREA A H-J Bid Set !"#$%#!& THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP,LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2006, 2007, 2008, 2009, JAMES R. STUTZMAN, AIA, CARMEL, INDIANA !"#$%&'()! !"#$%$&'() !" !! #$ % & '()'*' '()'*+ '()'*, ( !"#$%&'( )&*+$' Monday, May 24, 2010; alldata:MS:DESIGN:PROJECTS:CARMEL CITY CENTER:CCC Drawings:CCC Construction Doc:Building A:A.General:BLDG A SHELL FILES:NORTH MODULES:BLDG. A NORTH H-J.pln J 24.1 4 3/8" 3 1/4" 7" 1'-7 1/4" 2" 1/4" 7 5/8" #DrgID #LayID E.O.S. E.O.S. WEATHER BARRIER EIFS VENEER VAPOR BARRIER 6" CFS STUDS @ 16" O.C. BATT INSULATION 5/8" EXTERIOR SHEATHING 2x6 CFS STUD ATTACHED TO COLUMN SEE SHEET AA504 / AA505 FOR FIREPROOFING AND CFS FRAMING 2x8 CFS STUD 2x8 CFS STUD ATTACHED TO COLUMN 6" CFS STUDS @ 16" O.C. 1'-11 3/4" 3 3/8" 11 7/8" 7/8" 4" 2" 1 5/8" 6 1/2" 5 1/2" 1" 5/8" 1 3/8" 4" 1" 3/4" 3 1/8" 4 1/2" R 4" R 1 1/2" R 7/8" CORNICE WITH BUILT-IN GUTTER 5/8" EXTERIOR SHEATHING CFS BRACING AS REQUIRED 3/4" BACKER ROD AND CAULKING FIRE RETARDANT BLOCKING REF. TO 4/AA704 FOR FIRE RATED ROOF ASSEMBLY 4" CONTINUOUS SOFFIT VENTING BETWEEN BRACKETS CUT-OUT IN SOFFIT SHEATHING 2" 3/4" 1 1/2" 1/2" 3/4" 4" 1" 4 3/8" 1" 2 1/2" 1 1/4" 2 1/4" 2" 4 3/8" 5 3/8" 7/8" 2 1/2" 3/4" 2" 2 1/2"MIN R 1 1/2" R 2 3/8" EXPANSION JOINT 3/4" FIRE RETARDANT PLYWOOD PREFINISHED BRAKE METAL CAP 1 1/8" 6 1/2" 3'-0 1/8" 1 1/2" 2 1/2" 1" 2" 2 1/8" 4 1/2" 6 5/8" 1'-0 5/8" 1 1/2" 3" 3/4" 2" 1 1/2" 2" 3 3/8" 3'-6" 4"-6" SIKA DECOTHANE BALCONS LIQUID COATING SYSTEM 3/4" FIRE RETARDANT PLYWOOD PREFINISHED BRAKE METAL CAP RAILING POST FLASHING TO BE APPROVED BY P.D.G. & SIGNATURE CONSTRUCTION MILL FINISH (BARE) GLAVALUME FLASHING CONTINUOUS CONCEALED BUTYL MASTIC BED UNDER FLASHING SIKA, DECOTHANE BALCONS LIQ. COATING SYSTEM RETURNING UP RAILING POST BEYOND BEAD SEALANT. CONT. SIKA 15ML POLYURETHANE SIKA, DECOTHANE BALCONS LIQ. COATING SYSTEM APPLIED TO THE EDGE OF FLASHING 1 1/8" 6 1/2" 1'-7 3/4" 1 1/2" 2 1/2" 1" 2" 2 1/8" 4 1/2" 6 5/8" 1'-0 5/8" 1 1/2" 3" 3/4" 2" 1 1/2" 2" 3 3/8" 4" 2 1/2"MIN R 3 1/2" R 1 1/2" 3/4" FIRE RETARDANT PLYWOOD PREFINISHED BRAKE METAL CAP 6'-10 3/4" 2 3/8" 7" 5'-4" 7" 2 3/8" 4'-9" 3'-8" 1'-1" 7/8" 2" 3 7/8" 7 5/8" 2" 10 5/8" 4 7/8" 8 3/8" 1'-9" 3/4" 7/8" 1 3/4" 9 3/8" 3 1/4" 2 5/8" 2 3/8" 3'-4 1/8" 7" 6" 7" 6" 3" R 2 1/2" R 1'-1 3/4" R 7 1/2" R 2 7/8" R 1 1/8" R 7/8" A A ENLARGED EIFS DETAIL SCALE: 1/4" = 1'-0" B B B-B MINIMAL ASTHETIC REVEAL MINIMAL ASTHETIC REVEAL 4 7/8" 1" 5/8" 1 3/8" 4" 2 1/4" 1 1/2" 1'-2 3/8" 7/8" 4" 3/4" 3 1/8" 1'-8 5/8" 2 1/2"MIN PREFINISHED BRAKE METAL CAP 3/4" FIRE RETARDANT PLYWOOD METAL WALL PANEL CURVED TOP TRACK 3" 1 1/2" 1 1/2" 5" 4 1/4" 3/4" H 25 2'-5 7/8" 1'-6 1/8" 2'-0" 2'-0" 1'-11 3/8" 11 5/8" 1'-5 1/2" 1'-5 1/2" E.O.S., REF S-SERIES DWGS WEATHER BARRIER 8" CFS STUD WALL W/ 5/8" EXTERIOR SHEATHING REF SHEET AA504 / AA505 FOR TYPICAL FIREPROOFING DETAILS STEEL COLUMN, REF S-SERIES DWGS BRICK VENEER STONE BASE BELOW GUARD RAILING 2'-10 1/4" STEEL BEAM, REF. TO S-SERIES DRAWINGS 8" PVC PIPE 8" CFS STUD WALL 3" X 4" METAL DOWNSPOUT CORE DRILL THROUGH BALCONY SLAB FOR CONNECTION BRICK VENEER AWNING BEYOND HOLD TOP OF BRICK AT PIPE LOCATION BRICK VENEER BEYOND EIFS VENEER PVC PIPE SEAL 3'-1 1/2" STEEL BEAM, REF. TO S-SERIES DRAWINGS 8" PVC PIPE 8" CFS STUD WALL AWNING BEYOND BRICK VENEER EIFS CORNICE 3/4" FIRE RESISTIVE PLYWOOD 3" X 4" METAL DOWNSPOUT BACKER ROD AND SEALANT EIFS VENEER RUBBER FLASHING PREFINISHED METAL FLASHING 12" min. POWER VENT METAL FLASHING DECKING FIRE RETARDANT 2X WOOD CURBING 4 12 PENETRATION SIZED REQUIRED BY POWER VENT MANUFACTURE MISSING TRUSSES. MIN. REQD BY MANUFACTURER MIN. REQD BY MANUFACTURER MID SPAN SUPPORT SCALE: 1 1/2"= 1'-0" 1 PLAN DETAIL AA566 0 6'' 12'' 18'' SCALE: 1" = 1'-0" 4 DETAIL AA566 0 6'' 1' 2' SCALE: 1" = 1'-0" 6 DETAIL AA566 0 6'' 1' 2' SCALE: 1" = 1'-0" 2 DETAIL AA566 0 6'' 1' 2' SCALE: 1" = 1'-0" 7 DETAIL AA566 0 6'' 1' 2' SCALE: 1" = 1'-0" 3 DETAIL AA566 0 6'' 1' 2' SCALE: 1" = 1'-0" 5 DETAIL AA566 0 6'' 1' 2' SCALE: 3" = 1'-0" 8 EIFS DETAIL AA566 0 3'' 6'' 9'' SCALE: 1" = 1'-0" 9 PLAN DETAIL AA566 0 6'' 1' 2' SCALE: 1/2" = 1'-0" 10 DRAINAGE DETAIL AA566 0 1' 2' 4' SCALE: 1/2" = 1'-0" 11 DRAINAGE DETAIL AA566 0 1' 2' 4' SCALE: 1/2" = 1'-0" 12 POWER VENT DETAIL AA566 0 1' 2' 4' 12.12.08 JPM A.300A 05/20/10