Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
AA702 TYPICAL ARCHITECTURAL DETAILS
Project: Developer: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: By: Sheet Title: CARMEL CITY CENTER Carmel, Indiana Building A Phase 1 COPYRIGHT & OWNERSHIP OF DOCUMENTS Architecture / Project Management: Project Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue Date PEDCOR DESIGN GROUP LLC 0502.00 AA702 TYPICAL ARCHITECTURAL DETAILS Bid Set 04.21.06 THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP,LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP,LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP,LLC. © COPYRIGHT 2006, 2007, 2008 JAMES R. STUTZMAN, AIA, CARMEL, INDIANA 25 26 27 28 BID SET A.410 ISSUE, 12/29/08 BID SET A.210.ASI.01, 01/20/09 (AFFECTING A.300, A.310, A.400) WINDOW SCHEDULE UPDATE, 2/02/09 BID SET A.300, 02/07/09 MASONRY AND EIFS UPDATE BID SET A.300, 02/27/09 MASONRY AND EIFS UPDATE 2 A.300.ASI.004, 03/08/09 SCALE: NTS PLAN NORTH 28 22 16 H M AREA A AREA C AREA B R KEY PLAN BLDG A Wednesday, April 8, 2009; ALLDATA:MS:DESIGN:PROJECTS:CARMEL CITY CENTER:CCC Drawings:CCC Construction Doc:CCC Common Drawings:•General Details:GENERAL DETAILS.pln 28 SOPRAFIX MEMBRANE (PRIME LEAD) A B MEMBRANE PLY FIELD CAP SOPRAFIX MEMBRANE 15" (38cm) B 19.7" (50cm) A 24" (61cm) (DRAIN SUMP) 39.37" (1m) 34" (86cm) 30" (76cm) 15" 35" 30" (75cm) SQUARE MINIMUM 2 1/2 LB. TO 4 LB. (1.2kg TO 1.8kg) LEAD OR 16 OZ. (0.5kg) COPPER FLASHING SET IN BED OF SOPREMA MASTIC, PRIME TOP SURFACE BEFORE INSTALLING REINFORCING PLY. 4 SOPRAFIX FASTENERS ON EACH 30" (76cm) SIDE OF LEAD FLASHING. THIS REPRESENTS 39.37" (1m) x 39.37" (1m) STRIP-IN PLY OF SOPRAFIX MEMBRANE HEAT WELDED. 30" (75cm) SQUARE MINIMUM 2 1/2 LB. TO 4 LB. (1.2kg TO 1.8kg) LEAD OR 16 OZ. (0.5kg) COPPER FLASHING SET IN BED OF SOPREMA MASTIC, PRIME TOP SURFACE BEFORE INSTALLING REINFORCING PLY. (89cm) (38cm) REINFORCING PLY USE IN CONJUNCTION WITH SOPREMA GENERAL REQUIREMENTS AND APPROVED DETAILS WHILE CONSTRUCTING OTHER ROOF COMPONENTS TO EXCEED CURRENT EDITION REQUIREMENTS OF FM APPROVALS, SMACNA, NRCA, ANSI/SPRI ES-1 AND FLORIDA BUILDING CODE-RAS NO. 111 WITH THE MOST STRINGENT REQUIREMENTS OR RECOMMENDATIONS PREVAILING. 2. SOPREMA ADHESIVES, CEMENTS, MASTICS, PRIMERS AND SEALANTS ARE REQUIRED WHERE INDICATED. NOTES: 1. FIRE TREATED WOOD NAILER FASTENED AS REQUIRED CONTINUOUS TAPERED WOOD SHIM PRIME FLANGE BEFORE STRIPPING SET FLANGE IN SOPREMA MASTIC DETAIL TO BE USE IN CONJUNCTION WITH SOPREMA GENERAL REQUIREMENTS, APPLICATION METHODS AND APPROVED DETAILS. BASE PLY SOPREMA ADHESIVES, CEMENTS, MASTICS, PRIMERS AND SEALANTS ARE REQUIRED WHERE INDICATED. FASTENERS APPROX. 3" O.C. (76MM) STAGGERED AND FLUSH METAL EDGE FIRST MEMBRANE FLASHING PLY EXTEND DOWN OUTSIDE FACE OF SOLID MASONERY WALL TO BOTTOM OF WOOD NAILER. SEAL SIDE LAPS. WHEN A PROJECT SPECIFICATION REQUIRES SOPREMA TO WARRANT SHOP FORMED METAL(S), ROOFING CONTRACTOR MUST SUBMIT METAL SPECIFICATION AND ALL PROPOSED METAL DETAILS TO THE SOPREMA CORPORATE TECHNICAL DEPARTMENT FOR REVIEW/APPROVAL PRIOR TO BIDDING AND/OR INSTALLATION. CAP PLY 4. ON HEAT WELDED FLASHINGS EMBED GRANULES IN FLASHING AREA. CAP FLASHING MUST BE INSTALLED UNDER THE METAL EDGE WHEN HOT MOPPED OR ADHERED WITH FLASHING ADHESIVE. METAL FLANGE STRIPPED IN WITH EITHER ALSAN FLASHING SYSTEM OR HEAT WELDED POLYESTER CAP MEMBRANE STRIP-IN PLY. 3" MIN. THERMAL INSULATION, APPLIED TO DECK AS SPECIFIED OR REQUIRED SEALANT CAP MEMBRANE FLASHING PLY-HEAT WELDED PRIME MASONRY SUBSTRATE, ON HEAT WELDED FLASHING WITH WOOD SUBSTRATE, FASTEN SOPREMA APPROVED BASE SHEET 8" (203mm) O.C. IN GRID PATTERN AND AT SIDE LAPS. (NOT SHOWN) POLYESTER REINFORCING MEMBRANE PLY 6" 4" MIN. 4" TYP. (102mm) MAXIMUM 24" (610mm) MINIMUM 8" (203mm) (102mm) (152mm) 3. 2. NOTES: 1. 3" (76mm) 1/2" U.N.O. ON ROOF PLANS COORDINATE DECK OPENING SIZE W/ PLUMBING CONTRACTOR 4'-0" MEMBRANE ROOFING BEAM BEYOND REF. S-SERIES DRAWINGS FOR ALL STRUCTURAL STEEL REF. P-SERIES DRAWINGS FOR ALL PIPE SIZES MEMBRANE ROOFING OVERFLOW ROOF DRAIN W/ LOW SILHOUETTE DOME REF. P-SERIES DRAWINGS MAIN ROOF DRAIN W/ LOW SILHOUETTE DOME REF. P-SERIES DRAWINGS MEMBRANE ROOFING THERMAL INSULATION DOUBLE TOP SET DECK PLATE REF. P-SERIES DRAWINGS # #/## FRAMING FOR ROOF OPENING, REF. S-SERIES DRAWINGS THERMAL INSULATION 4" 2 3/4" x 1/2" ALUM. SPACER CONTINUOUS EXPANSION JOINT COVER FLOOR FINISH COMPOSITE SLAB REF. S-SERIES DRAWINGS POUR STOP REF. S-SERIES DRAWINGS SOUND ISOLATION SLAB GROUT CAVITY FULL NOTE: THE FIRE RATING FOR THIS AND SIMILAR CONDITIONS IS DETERMINDE BY THE PREFORMANCE CAPABILITIES OF THE SURROUNDING CONSTRUCTION RATHER THAN THE METAFLEX FIRE BARRIER FF2H08AA METACAULK 9901 2'-0" FIRE RETARDANT PLYWOOD 1/2" 4" 8" MIN. MASONRY VENEER ANGLE CONNECTIONS, REF. S-SERIES DRAWINGS EXTERIOR FIRE- RETARDANT TREATED 2x WOOD BLOCKING [ AS REQUIRED] COMPOSITE SLAB REF. S-SERIES DRAWINGS VEGITATED PROTECTED MEMBRANE ROOFING 5/8" EXTERIOR FIRE- RETARDANT PLYWOOD 2'-0" HIGH MORTAR NET LIQUID APPLIED WEATHER BARRIER, OVERLAP OVER THRU-WALL FLASHING OR MEET MANUFACTURER'S REQUIREMENT IF MORE THAN 8". CONTINUOUS YORK FLASH- VENT SET ABOVE COPPER FLASHING AND EXTENDED MIN. 1" BEYOND FACE OF VENEER - LAP OVER COUNTERFLASHING ABOVE EXPANSION JOINT ASSEMBLY ONE HOUR FIRE RATED ASSEMBLY BELLOWS TYPE ROOF EXPANSION JOINT WITH METAL FLANGE 4" 8" MIN. 1/2" 18" T0 24" BELLOWS TYPE ROOF EXPANSION JOINT WITH METAL FLANGE EXTERIOR FIRE- RETARDANT TREATED 2x WOOD BLOCKING [AS REQUIRED] VEGITATED PROTECTED MEMBRANE ROOFING ANGLE CONNECTIONS, REF. S-SERIES DRAWINGS COMPOSITE SLAB REF. S-SERIES DRAWINGS NOTE: THE FIRE RATING FOR THIS AND SIMILAR CONDITIONS IS DETERMINED BY THE PREFORMANCE CAPABILITIES OF THE SURROUNDING CONSTRUCTION RATHER THAN THE FIRE BARRIER ONE HOUR FIRE RATED ASSEMBLY STAGGER BOLT ANCHOR ALIGHNMENT ACROSS OPPOSITE ANGLES 12 NO VEGETATION ZONE AA701 2'-0" FIRE RETARDANT PLYWOOD 8" MIN. 3/8" 5" 4" NOTE: THE FIRE RATING FOR THIS AND SIMILAR CONDITIONS IS DETERMINED BY THE PREFORMANCE CAPABILITIES OF THE SURROUNDING CONSTRUCTION RATHER THAN THE FIRE BARRIER EXTERIOR FIRE- RETARDANT TREATED 2x WOOD BLOCKING [AS REQUIRED] STEEL STUD REFRENCE ROOFING DETAILS FOR MEMBRANE APPLICATION ONE HOUR FIRE RATED ASSEMBLY RIGID INSULATION METAL ROOF DECK REF. S-SERIES DRAWINGS 5/8" EXTERIOR FIRE- RETARDANT PLYWOOD 2'-0" HIGH LIQUID APPLIED WEATHER BARRIER EIFS OR MEET MANUFACTURER'S REQUIREMENT IF MORE THAN 8". ANGLE CONNECTIONS, REF. S-SERIES DRAWINGS BELLOWS TYPE ROOF EXPANSION JOINT WITH METAL FLANGE EXTERIOR FIRE- RETARDANT AND PRESSURE TREATED WOOD BLOCKING [AS REQUIRED] @ SECOND FLOOR @ FIFTH FLOOR CORE DRILL COMPOSITE ROOF DECK FOR DRAIN CORE DRILL COMPOSITE ROOF DECK FOR DRAIN 1'-0 1/2" UNO ON ROOF PLANS 2'-0" MEMBRANE ROOFING BEAM BEYOND REF. S-SERIES DRAWINGS FOR ALL STRUCTURAL STEEL REF. P-SERIES DRAWINGS FOR ALL PIPE SIZES MEMBRANE ROOFING OVERFLOW ROOF DRAIN W/ LOW SILHOUETTE DOME REF. P-SERIES DRAWINGS MAIN ROOF DRAIN W/ LOW SILHOUETTE DOME REF. P-SERIES DRAWINGS MEMBRANE ROOFING THERMAL INSULATION THERMAL INSULATION # #/## COMPOSITE SLAB REF. S-SERIES DRAWINGS COMPOSITE SLAB REF. S-SERIES DRAWINGS CLOUMN LINE R 4" 8" METAL ROOF DECK REF. S- SERIES DRAWINGS STEEL STUD STRUCTURAL STEEL REF. S-SERIES DRAWINGS RIGID INSULATION AS REQUIRED TERMINATION BAR W/ FASTENERS AND SEALANT @ 8" O.C. MEMBRANE ROOFING METAL SIDING FURRING CHANEL 5/8" SHEATHING 5/8" EXTERIOR FIRE- RETARDANT PLYWOOD 2'-0" HIGH LIQUID APPLIED WEATHER BARRIER OR MEET MANUFACTURER'S REQUIREMENT IF MORE THAN 8". EXTERIOR FIRE- RETARDANT AND PRESSURE TREATED WOOD BLOCKING [AS REQUIRED] SCALE: 1' = 1'-0" 2 SOPRAFIX DRAIN AA702 0 1/2'' 1'' 2'' SCALE: 1' = 1'-0" 4 WALL BASE FLASH W/METAL EDGE AA702 0 1/2'' 1'' 2'' SCALE: 3" = 1'-0" 3 DOUBLE ROOF DRAIN-STEEL DECK AA702 0 3'' 6'' 9'' SCALE: 3" = 1'-0" 5 EXPANSION JOINT DETAIL AA702 0 3'' 6'' 9'' SCALE: 3" = 1'-0" 6 EXPANSION JOINT DETAIL AA702 0 3'' 6'' 9'' SCALE: 3" = 1'-0" 7 EXPANSION JOINT DETAIL AA702 0 3'' 6'' 9'' SCALE: 3" = 1'-0" 8 EXPANSION JOINT DETAIL AA702 0 3'' 6'' 9'' SCALE: 3" = 1'-0" 1 DOUBLE ROOF DRAIN-COMP. DECK AA702 0 3'' 6'' 9'' SCALE: 3" = 1'-0" 9 METAL ROOF DECK / WALL AA702 0 3'' 6'' 9'' 06/27/08 A.220, A300C.1, A.305C JPM, LS JAW 2/27/09