Loading...
HomeMy WebLinkAboutAA703 TYPICAL ARCHITECTURAL DETAILSProject: Developer: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: By: Sheet Title: CARMEL CITY CENTER Carmel, Indiana Building A Phase 1 COPYRIGHT & OWNERSHIP OF DOCUMENTS Architecture / Project Management: Project Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue Date PEDCOR DESIGN GROUP LLC 0502.00 AA703 TYPICAL ARCHITECTURAL DETAILS Bid Set 04.21.06 THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP,LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP,LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP,LLC. © COPYRIGHT 2006, 2007, 2008 JAMES R. STUTZMAN, AIA, CARMEL, INDIANA 25 26 27 BID SET A.410 ISSUE, 12/29/08 BID SET A.210.ASI.01, 01/20/09 (AFFECTING A.300, A.310, A.400) WINDOW SCHEDULE UPDATE, 2/02/09 BID SET A.300, 02/07/09 MASONRY AND EIFS UPDATE BID SET A.300, 02/27/09 MASONRY AND EIFS UPDATE 2 SCALE: NTS PLAN NORTH 28 22 16 H M AREA A AREA C AREA B R KEY PLAN BLDG A Thursday, February 26, 2009; alldata:MS:DESIGN:PROJECTS:CARMEL CITY CENTER:CCC Drawings:CCC Construction Doc:CCC Common Drawings:•General Details:GENERAL DETAILS.pln 27 27 27 27 27 27 27 27 27 27 27 27 27 5' (1.5m) WITH 2" (51mm) SPACE BETWEEN PIECES. SOPRAWALK PROTECTION LAYER - MAXIMUM LENGTHS THERMAL INSULATION, COVERBOARD AND ROOFING PLIES APPLIED TO DECK AS SPECIFIED OR REQUIRED NOTES: DETAIL TO BE USE IN CONJUNCTION WITH SOPREMA GENERAL REQUIREMENTS, APPLICATION METHODS AND APPROVED DETAILS. SOPREMA WARRANTS ADHESION TO EXISTING SOPREMA FIELD CAP MEMBRANE PLY WHEN SOPRAWALK IS FULLY HEAT WELDED OR ADHERED WITH 2-PART MEMBRANE ADHESIVE (REMOVE PLASTIC FILM IF PRESENT) EMBED GRANULES MIN. 6" (152mm) AROUND EXISTING CAP SHEET EDGES AND PRIME INNER AREAS BEFORE HEAT WELDING SOPRAWALK. SOPREMA ADHESIVES, CEMENTS, MASTICS, PRIMERS AND SEALANTS ARE REQUIRED WHERE INDICATED. SOPREMA DOES NOT WARRANT ADHESION TO EXISTING SOPREMA FIELD CAP MEMBRANE PLY WHEN OTHER ADHESIVE METHODS ARE USED. 1. 2. 3. 4. 5 1/2" 3" COMPOSITE ROOF DECK 2" 7 1/2" 6" 6 1/2" 6'-5 1/2" 1'-0" 2'-9" 2'-9" 7 1/2" COMPOSITE DECK REF. S-SERIES DRAWINGS 1/4" 12" MEMBRANE ROOFING 3" THERMAL INSULATION REF. S-SERIES DRAWINGS FOR ALL STRUCTURAL STEEL STEEL TUBE COLUMN REF. S- SERIES DRAWINGS STEEL CHANNEL REF. S-SERIES DRAWINGS O.0 ENGINEERED EIFS PANELING (FEATHERLITE) TNEMEC PAINT COATED STEEL PAVERS 1/2" DENS DECK RECOVERY BOARD ROOF FLASHING 2'-0" FIRE RETARDANT PLYWOOD 8" MINIMUM ARCHITECTURAL COPPER COUNTER FLASHING MASONRY VENEER USE CONRETE BLOCK AT ALL HIDDEN MASONRY CONDITIONS ROOFING MEMBRANE TO TURN UP VENEER FACE AND STOP BEFORE MORTAR JOINT VEGETATED PROTECTED MEMBRANE ROOFING ROOFING MEMBRANE COMPOSITE SLAB REF. S- SERIES DRAWINGS DRAINAGE MATT REF. S-SERIES DRAWINGS FOR ALL STRUCTURAL STEEL PRESSURE TREATED WOOD BLOCKING TERMINATION BAR W/ FASTENERS AND SEALANT @ 8" O.C. 60 PSI INSULATION - DOW 'PLAZAMATE' MIN. 3" 5/8" EXTERIOR FIRE- RETARDANT PLYWOOD LIQUID APPLIED WEATHER BARRIER, LAP OVER THRU-WALL FLASHING, REFERENCE 3/AA703. OR MEET MANUFACTURER'S REQUIREMENT IF MORE THAN 8". CONTINUOUS YORK FLASH-VENT SET ABOVE COPPER FLASHING AND EXTENDED MIN. 1" BEYOND FACE OF VENEER - TRIM BACK TO FACE OF VENEER ONLY AFTER ARCHITECTS INSPECTION EXTERIOR FIRE- RETARDANT AND PRESSURE TREATED WOOD BLOCKING AS REQ. 12 AA701 8" MIN. 2'-0" FIRE RETARDANT PLYWOOD ROOFING MEMBRANE TO TURN UP WALL AND COUNTER FLASHED EXTERIOR FIRE- RETARDANT AND PRESSURE TREATED WOOD BLOCKING AS REQ. ROOFING MEMBRAINE COMPOSITE SLAB REF. S- SERIES DRAWINGS WRAP EIFS MESH 2" MIN. AT BACKSIDE OF EPS DRAINAGE MATT REF. S-SERIES DRAWINGS FOR ALL STRUCTURAL STEEL TERMINATION BAR W/ FASTENERS @ 8" O.C. 60 PSI INSULATION - DOW 'PLAZAMATE' MIN. 3" COUNTER FLASHING EIFS COMPATABLE SEALANT W/BACKER ROD INSULATION BOARD EIFS FINISH WEATHER BARRIER 5/8" EXTERIOR FIRE- RETARDANT PLYWOOD 2'-0" HIGH OR MEET MANUFACTURER'S REQUIREMENT IF MORE THAN 8". VEGETATED PROTECTED MEMBRANE ROOFING 15/16" SOUND ISOLATION SLAB RIGID INSULATION AS REQUIRED 1/2" DENS DECK TO BE USED ONLY IN AREAS THAT HAVE PAVERS ON ROOF COMPOSITE DECK REF. S-SERIES DRAWINGS METAL ROOF DECK REF. S-SERIES DRAWINGS PLAZA PAVER TERMINATION BAR W/ FASTENERS AND SEALANT @ 8" O.C. STEEL STUD STRUCTURAL STEEL REF. S- SERIES DRAWINGS 1/2" EXPANSION JOINT MEMBRANE ROOFING 5/8" FIRE- RETARDANT PLYWOOD LIQUID APPLIED WEATHER BARRIER PRESSURE TREATED BLOCKING OR MEET MANUFACTURER'S REQUIREMENT IF MORE THAN 8". EXTERIOR FIRE- RETARDANT AND PRESSURE TREATED WOOD BLOCKING AS REQ. 8" MIN METAL ROOF DECK REF. S-SERIES DRAWINGS 5/8" EXTERIOR FIRE- RETARDANT PLYWOOD 2'-0" HIGH STEEL STUD STRUCTURAL STEEL REF. S- SERIES DRAWINGS RIGID INSULATION AS REQUIRED TERMINATION BAR W/ FASTENERS AND SEALANT @ 8" O.C. COMPOSITE DECK REF. S-SERIES DRAWINGS MEMBRANE ROOFING LIQUID APPLIED WEATHER BARRIER CLADDING OR MEET MANUFACTURER'S REQUIREMENT IF MORE THAN 8". EXTERIOR FIRE- RETARDANT AND PRESSURE TREATED WOOD BLOCKING AS REQ. 8" MIN. MASONRY VENEER STEEL ANGLE REF. S-SERIES DRAWINGS SEALANT & BACKER ROD UNDER FLASHING PROVIDE PROTECTION MATERIAL AT BOLT LOCATIONS EXTERIOR SHEATHING TO HAVE 5/8" GAP UNDERSIDE OF ANGLE, SEALANT AT GAP REQUIRED. MORTAR JOINT SIZE 3/8" (+,-) TYPICAL EXTERIOR SHEATHING EXTERIOR SHEATHING YORK FLASH-VENT THRU WALL FLASHING 1/4" COMPRESSIBLE MATERIAL LIQUID APPLIED WATER/AIR MEMBRANE JOINT TREATMENT (MESH) LIQUID APPLIED WATER/AIR MEMBRANE TERMINATION BAR OR ADHESIVE, APPROVED BY BOTH FLASHING MANUFACTURER AND LIQUID APPLIED MOISTURE/ AIR MEMBRANE MANUFACTURE 2'-0" FIRE RETARDANT PLYWOOD 8" MIN. ARCHITECTURAL COPPER COUNTER FLASHING MASONRY VENEER USE CONRETE BLOCK AT ALL HIDDEN MASONRY CONDITIONS ROOFING MEMBRANE TO TURN UP VENEER FACE AND STOP BEFORE MORTAR JOINT ROOFING MEMBRANE COMPOSITE SLAB REF. S- SERIES DRAWINGS CONTINUOUS YORK FLASH-VENT SET ABOVE COPPER FLASHING AND EXTENDED MIN. 1" BEYOND FACE OF VENEER - TRIM BACK TO FACE OF VENEER ONLY AFTER ARCHITECTS INSPECTION REF. S-SERIES DRAWINGS FOR ALL STRUCTURAL STEEL PRESSURE TREATED WOOD BLOCKING TERMINATION BAR W/ FASTENERS AND SEALANT @ 8" O.C. 3" OF RIGID INSULATION 5/8" EXTERIOR FIRE- RETARDANT PLYWOOD LIQUID APPLIED WEATHER BARRIER, LAP OVER THRU-WALL FLASHING, REFERENCE 3/AA703. OR MEET MANUFACTURER'S REQUIREMENT IF MORE THAN 8". EXTERIOR FIRE- RETARDANT AND PRESSURE TREATED WOOD BLOCKING AS REQ. 12 AA701 8" MIN. 2'-0" FIRE TREATED PLYWOOD ROOFING MEMBRAINE COMPOSITE SLAB REF. S- SERIES DRAWINGS REF. S-SERIES DRAWINGS FOR ALL STRUCTURAL STEEL 3" OF RIGID INSULATION 5/8' EXT. SHEATHING ROOFING MEMBRANE TO TURN UP WALL AND COUNTER FLASHED WRAP EIFS MESH 2" MIN. AT BACKSIDE OF EPS TERMINATION BAR W/ FASTENERS @ 8" O.C. COUNTER FLASHING EIFS COMPATABLE SEALANT W/BACKER ROD INSULATION BOARD EIFS FINISH WEATHER BARRIER EXTERIOR FIRE- RETARDANT AND PRESSURE TREATED WOOD BLOCKING AS REQ. 3" STEEL DECK REF. S- SERIES DRAWINGS 12" 3" MIN. THERMAL INSULATION 1/4" MEMBRANE ROOFING 3" 4" (+,-) 1/4" 12" COMPOSITE DECK REF. S-SERIES DRAWINGS 3" MIN. THERMAL INSULATION REF. S-SERIES DRAWINGS FOR ALL STRUCTURAL STEEL MEMBRANE ROOFING SCALE: 1' = 1'-0" 8 SOPRAWALK PROTECTION MEMBRANE AA703 0 1/2'' 1'' 2'' SCALE: 3" = 1'-0" 5 SCREEN WALL TO ROOF AA703 0 3'' 6'' 9'' SCALE: 1 1/2"= 1'-0" 10 GREEN ROOF TO BRICK WALL AA703 0 6'' 12'' 18'' SCALE: 1 1/2"= 1'-0" 9 GREEN ROOF TO PARAPET WALL AA703 0 6'' 12'' 18'' SCALE: 3" = 1'-0" 2 COMPOSITE ROOF DECK TO WALL AA703 0 3'' 6'' 9'' SCALE: 3" = 1'-0" 1 METAL ROOF DECK / WALL AA703 0 3'' 6'' 9'' SCALE: 3" = 1'-0" 3 BRICK ANGLE FLASHING AA703 0 3'' 6'' 9'' SCALE: 1 1/2"= 1'-0" 6 COMPOSITE ROOF TO MASONRY AA703 0 6'' 12'' 18'' SCALE: 1 1/2"= 1'-0" 7 COMPOSITE ROOF TO PARAPET AA703 0 6'' 12'' 18'' SCALE: 3" = 1'-0" 4 OFFSET ROOF VALLEY DETAIL AA703 0 3'' 6'' 9'' 06/27/08 JPM, LS JAW A.220, A300C.1, A.305C 02/27/09