Loading...
HomeMy WebLinkAboutAA704 TYPICAL ARCHITECTURAL DETAILSProject: Developer: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: By: Sheet Title: CARMEL CITY CENTER Carmel, Indiana Building A Phase 1 COPYRIGHT & OWNERSHIP OF DOCUMENTS Architecture / Project Management: Project Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue Date PEDCOR DESIGN GROUP LLC 0502.00 AA704 TYPICAL ARCHITECTURAL DETAILS Bid Set !"#$%#!& THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP,LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2006, 2007, 2008, 2009, JAMES R. STUTZMAN, AIA, CARMEL, INDIANA 37 38 CCC.A.ASI.11, 9/18/09 CCC.A.ASI.12, 9/29/09 !"#$%&’()! !"#$%$&’() !" !! #$ % & ’()’*’ ’()’*+ ’()’*, ( !"#$%&’( )&*+$’ Tuesday, September 29, 2009; ALLDATA:MS:DESIGN:PROJECTS:CARMEL CITY CENTER:CCC Drawings:CCC Construction Doc:CCC Common Drawings:•General Details:GENERAL DETAILS.pln 21 38 38 (1/2") MIN. (1/2") MIN. 2X STEEL STUD 5/8" EXT. SHEATHING SEALANT W/ CLOSED CELL BACKER ROD WEATHER BARRIER 2 1/4" AIR SPACE MASONRY VENEER FLASHING TAPE CONTINIOUS AROUND PIPE CFS BLOCKING TO SUPPORT PIPE 2'-0" 8" MIN, 3" RIGID INSULATION METAL ROOF DECK REF. S-SERIES DRAWINGS !"# STEEL STUD TERMINATION BAR W/ FASTENERS AND SEALANT @ 8" O.C. MEMBRANE ROOFING CLADDING 5/8" EXTERIOR FIRE- RETARDANT PLYWOOD 24" HIGH LIQUID APPLIED WEATHER BARRIER 5/8" EXTERIOR SHEATHING OR MEET MANUFACTURER'S REQUIREMENT IF MORE THAN 8". EXTERIOR FIRE- RETARDANT AND PRESSURE TREATED WOOD BLOCKING [AS REQUIRED] X 8" 2 1/2" 6" 1-1/2" E.I.F.S., SEE ELEVATION FOR REQUIRED BANDS. EXTERIOR FIRE- RETARDANT AND PRESSURE TREATED 2x8 BLOCKING 3" RIGID INSULATION PRE-FINISHED ALUMINUM FASCIA MODIFIED BIT. FLASHING MODIFIED BIT. ROOFING STEEL BEAMS, REFERNCE S-SERIES DRAWINGS 5/8" EXTERIOR SHEATHING LIQUID APPLIED WEATHER BARRIER 25 MSG GALV. FURRING CHANNELS 5/8" GYPSUM BOARD FIRE CAULKING SEE SHEET AA504 / AA505 FOR FIREPROOFING DETAILS SEE PARTICULAR FACADE DRAWING FOR FASCIA, SOFFIT AND GUTTER REQUIREMENTS. U.L. DESIGNS REQUIRED TO BE FOLLOWED: U.L. BXUV.P525 OR U.L. BXUV.P540 1 1/2" STRUCTURAL STEEL DECK 1/2" DENSDECK PREFINISHED METAL ROOFING AND 1/2" FIRE RETARDANT PLY WOOD SHEATHING AS REQUIRED BY METAL SHINGLE MANUFACTURE. SHEATHING NOT USED AT STANDING SEAM ROOF TYPE. BATT INSULATION STEEL TRUSS TRUSS ATTACHMENT CLIP ICE AND WATER SHIELD (EXTEND DOWN FACIA 4") 30 LB. FELT UNDERLAYMENT CLIP 20" O.C. MAX (@ STANDING SEAM ROOF) FIELD FOLD END OF PANEL DRIP EDGE SEALANT GUTTER STRAP PREFINISHED METAL GUTTER FIRE RETARDANT WOOD BLOCKING FASCIA WRAP 2" POLYISOCYANURATE BOARD BENT PLATE (IF NOT PROVIDED, FIRE RETARDANT BLOCKING REQUIRED) BEARING PLATE (@ STANDING SEAM ROOF) EIFS OR BRICK VENEER 5/8" EXTERIOR SHEATHING 4" CONTINUOUS SOFFIT VENTING 8" MIN. ARCHITECTURAL COPPER COUNTER FLASHING MASONRY VENEER USE CONRETE BLOCK AT ALL HIDDEN MASONRY CONDITIONS ROOFING MEMBRANE TO TURN UP VENEER FACE AND STOP BEFORE MORTAR JOINT ROOFING MEMBRANE COMPOSITE SLAB REF. S- SERIES DRAWINGS CONTINUOUS YORK FLASH-VENT SET ABOVE COPPER FLASHING AND EXTENDED MIN. 1" BEYOND FACE OF VENEER - TRIM BACK TO FACE OF VENEER ONLY AFTER ARCHITECTS INSPECTION TERMINATION BAR W/ FASTENERS AND SEALANT @ 8" O.C. 3" OF RIGID INSULATION LIQUID APPLIED WEATHER BARRIER, LAP OVER THRU-WALL FLASHING OR MEET MANUFACTURER'S REQUIREMENT IF MORE THAN 8". PAVERS ON PEDESTALS 1/2" DENS DECK OVER INSULATION 5" - 6" 3" - 4" CFS STUD WALL EIFS VENEER (2 1/2") MIN, 5/8" GYPSUM BOARD SHEATHING PORCH CONC. SLAB SIKA, DECOTHANE BALCONS LIQ. COATING SYSTEM PREFINISHED BREAK METAL FLASHING 0.300" POWER- ACTUATED FLUSH PINS @ 12" O.C. BEAD SEALANT, CONT. SIKA 15ML POLYURETHANE MILL FINISH (BARE) GALVALUME FLASHING CONTINUOUS CONCEALED BUTYL MASTIC BED UNDER FLASHING SIKA, DECOTHANE BALCONS LIQ. COATING SYSTEM APPLIED TO THE EDGE OF FLASHING 6"MIN 3" - 4" 5" - 6" CFS STUD WALL 5/8" GYPSUM BOARD PORCH CONC. SLAB SIKA, DECOTHANE BALCONS LIQ. COATING SYSTEM STONE SILL BRICK VENEER SHEATHING PREFINISHED BREAK METAL FLASHING CONTINUOUS CONCEALED BUTYL MASTIC BED UNDER FLASHING BACKER ROD & SEALANT 0.300" POWER- ACTUATED FLUSH PINS @ 12" O.C. BEAD SEALANT, CONT. SIKA 15ML POLYURETHANE SIKA, DECOTHANE BALCONS LIQ. COATING SYSTEM APPLIED TO EDGE OF FLASHING CONTINUOUS CONCEALED BUTYL MASTIC BED UNDER FLASHING MILL FINISH (BARE) GALVALUME FLASHING SELF-ADHERING RUBBERIZED ASPHALT FLASHING COPPER-FABRIC THRU WALL FLASHING, PREFINISHED BRAKE METAL EIFS PROFILE BELOW BACKER ROD AND SEALANT STONE PROFILE 3/4" EXTERIOR FIRE- RETARDANT PLYWOOD BRICK VENEER 1 1/2" STRUCTURAL STEEL DECK PREFINISHED METAL ROOFING BATT INSULATION 25 MSG GALV. FURRING CHANNELS 5/8" GYPSUM BOARD SEE SHEET AA504 / AA505 FOR FIREPROOFING DETAILS STEEL TRUSS TRUSS ATTACHMENT CLIP ICE AND WATER SHIELD (EXTEND DOWN FACIA 4") SEE PARTICULAR FACADE DRAWING FOR FASCIA, SOFFIT AND GUTTER REQUIREMENTS. SEE PARTICULAR ARCHITECTURAL WALL SECTION AND STRUCTURAL DRAWINGS FOR ACTUAL CONFIGURATION 30 LB. FELT UNDERLAYMENT STANDING SEAM ROOF PANEL CLIP 20" O.C. MAX FIELD FOLD END OF PANEL DRIP EDGE SEALANT GUTTER STRAP PREFINISHED METAL GUTTER FIRE RETARDANT WOOD BLOCKING FASCIA WRAP 8 5/8" 1 1/2" STRUCTURAL STEEL DECK PREFINISHED METAL ROOFING STEEL BEAM, REF. TO S-SERIES DWGS. 1/2" FIRE RETARDANT PLYWOOD PREFINISHED METAL GUTTER SEE SHEET AA504/AA505 FOR FIREPROOFING DETAILS EIFS VENEER BRICK VENEER DIRECT APPLIED FINISH SYSTEM SOFFIT 3" POLYISOCYANURATE BOARD STEEL KICKER, REF. TO S-SERIES DRAWINGS PANEL CLIP, 20" O.C. MAX 30 LB. FELT UNDERLAYMENT BEARING PLATE FIRE RETARDENT WOOD BLOCKING ICE AND WATER SHEILD (EXTEND DOWN FACIA 4") DRIP EDGE FIELD FOLD END OF PANEL SEALANT GUTTER STRAP BENT PLATE 1/2" DENS DECK FIREPROOFING SCALE: 3" = 1'-0" 1 TYPICAL DETAIL AA704 0 3'' 6'' 9'' SCALE: 3" = 1'-0" 2 TYPICAL DETAIL AA704 0 3'' 6'' 9'' SCALE: 1" = 1'-0" 3 TYPICAL DETAIL AA704 0 6'' 1' 2' SCALE: 1 1/2"= 1'-0" 4 ROOF DETAIL AA704 0 6'' 12'' 18'' SCALE: 1 1/2"= 1'-0" 5 PAVERS / PARAPET WALL AA704 0 6'' 12'' 18'' SCALE: 3" = 1'-0" 6 TYPICAL DETAIL AA704 0 3'' 6'' 9'' SCALE: 3" = 1'-0" 7 TYPICAL DETAIL AA704 0 3'' 6'' 9'' SCALE: 1 1/2"= 1'-0" 8 CORNICE FLASHING DETAIL AA704 0 6'' 12'' 18'' SCALE: 1 1/2"= 1'-0" 9 ROOF DETAIL AA704 0 6'' 12'' 18'' SCALE: 1 1/2"= 1'-0" 10 ROOF DETAIL AA704 0 6'' 12'' 18'' 06/27/08 JPM, LS JAW A.220, A300C.1, A.305C 09.29.09