Loading...
HomeMy WebLinkAboutAAF105A Fifth Floor - Area A24 BID SET A.220 LOUVER HT. ADJUSTMENT 11/24/08 DRAIN LOCATIONS BID SET A.310 A ISSUE, 12/12/08 BID SET A.210 FINAL ISSUE, 12/12/08 Project: Developer: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: By: Sheet Title: CARMEL CITY CENTER Carmel, Indiana Building A Phase 1 COPYRIGHT & OWNERSHIP OF DOCUMENTS Architecture / Project Management: Project Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue Date PEDCOR DESIGN GROUP LLC 0502.00 AAF105A Fifth Floor - Area A THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP,LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP,LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP,LLC. © COPYRIGHT 2006, 2007, 2008 JAMES R. STUTZMAN, AIA, CARMEL, INDIANA 04.21.06 Bid Set SCALE: NTS PLAN NORTH 28 22 16 H M AREA A AREA C AREA B R KEY PLAN BLDG A Friday, December 12, 2008; ALLDATA:MS:DESIGN:PROJECTS:CARMEL CITY CENTER:CCC Drawings:CCC Construction Doc:Building A:A.210:Bid Set A.210.pln H H.5 J J.05 J.1 J.2 J.3 J.4 J.5 K K.5 L L.1 L.5 L.9 M AREA A AREA B 1 2 3 MA1 Mechanical Shaft M-A Mechanical Room Hood Fan Space Hood Shaft EA2 M Machine Room MA-1R Mechanical Room C M-A Mechanical Room STAIR Stair SA2 SA1 28.2 28.1 28 27.6 27.5 27 26.9 26.5 26.4 26.3 26 25.7 25.4 25.3 25 24.1 24 23.6 23.1 23 28 27.6 27 26 25 24 23 23.6 26.4 26.5 24.1 23.1 28.2 28.1 25.7 25.4 26.9 26.3 27.5 25.3 FIRE PROTECTION FLOOR PLAN NOTES 1 Beam is sandwiched between walls above and/or below. Apply intumescent paint in lieu of SFRM. 2 Apply intumescent paint in lieu of SFRM at framing in this area. Include columns of this space. 3 No fire rating required, per IBC 2000, pargraph 1509.2 exception 1. 4 Shading indicates SFRM required above space indicated on this plan level. 5 Column to be treated w/SFRM GENERAL NOTES 1. Review sheet AA504 for column details pertaining to fire protection, CMU and AAC wall construction at columns. Review sheets AA521-AA525 for additional wall interfacing with column and coordination with plumbing. 2. All columns at First Floor shall be rated 2 Hours and be protected by SFRM unless noted or detailed otherwise. 3. All columns above First Floor shall be rated 1Hour unless noted otherwise. SFRM shall be used unless otherwise noted or detailed. 4. Shading on plans indicates the regions to receive the corresponding rating. Columns below framing represented on a given floor shall be the same rating indicated by the shading. See the legend for various rating types. 5. Apply intumescent paint in lieu of SFRM at floor framing under machine room floor slab inside elevator hoistway. 2 2 1 HOUR SPRAY-APPLIED FIRE RESISTIVE MATERIAL (SFRM) SEE DETAIL 8/AA504. BALCONY SPRAY-APPLIED FIRE RESISTIVE MATERIAL (SFRM) AREA SEE DETAIL 4/AA504. 1 & 2 HOUR SHADING INDICATED REQUIRED RATING. 2 HOUR SPRAY-APPLIED FIRE RESISTIVE MATERIAL (SFRM) SEE DETAIL 8 & 12/AA504. 1 HOUR SPRAY-APPLIED FIRE RESISTIVE MATERIAL (SFRM) ROOF SEE DETAIL 16/AA504. REGIONAL PLAN NOTE SCALE: 1/8" = 1'-0" 1 Fifth Floor Unit Plan AAF105A 0 4' 8' 16' FIRE PROTECTION LEGEND JAW A.210 08.21.08 LES, DJS 12.12.08