HomeMy WebLinkAboutAAG001 General ArchitecturalProject: Developer: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: By: Sheet Title: CARMEL CITY CENTER Carmel, Indiana Building A Phase 1 COPYRIGHT & OWNERSHIP OF DOCUMENTS Architecture / Project Management: Project Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue Date PEDCOR DESIGN GROUP LLC 0502.00 AAG001 General Architectural 04.21.06 THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP,LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP,LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP,LLC. © COPYRIGHT 2006, 2007, 2008 JAMES R. STUTZMAN, AIA, CARMEL, INDIANA 25 26 BID SET A.410 ISSUE, 12/29/08 BID SET A.210.ASI.01, 01/20/09 (AFFECTING A.300, A.310, A.400) WINDOW SCHEDULE UPDATE, 2/02/09 BID SET A.300, 02/07/09 MASONRY AND EIFS UPDATE E R 28 22 16 H 11 SCALE: NTS PLAN NORTH KEY PLAN 26 26 26 26 26 26 26 26 26 26 26 26 26 26 26 A6C A6D A6E A8 A8A A8B A8C M4 M6 C12 C16 C6 C8 A8D C10 M8 M8A P12 P8 M8B S1.5A S2.5A S2.5H S2.5E Thickness Wall Legend Plan View Section View Brief Description 6" AAC Thick block; 7/8" metal furring + 5/8" gypsum board one side; litewall finish. 6" AAC Thick block; 7/8"" metal furring + 5/8" gypsum board one side. 6" AAC Thick block; 7/8"" metal furring + 5/8" gypsum board both sides. 8" AAC Thick block; See floor plan for any added veneer or furring. 8" AAC Thick block; Interior litewall finish one side. 8" AAC Thick block; Interior litewall finish both sides. 8" AAC Thick block; 7/8"" metal furring + 5/8" gypsum board one side; litewall finish. 8" AAC Thick block; 7/8"" metal furring + 5/8" gypsum board one side. 6" CONC Wall;See floor plan for any added veneer or furring. 8" CONC Wall;See floor plan for any added veneer or furring. 10" CONC Wall;See floor plan for any added veneer or furring. 12" CONC Wall;See floor plan for any added veneer or furring. 16" CONC Wall;See floor plan for any added veneer or furring. 4" Concrete Masonry Wall;See floor plan for any added veneer or furring. 6" Concrete Masonry Wall;See floor plan for any added veneer or furring. 8" Concrete Masonry Wall;See floor plan for any added veneer or furring. 8" Concrete Masonry Wall; 7/8"" metal furring + 5/8" gypsum board one side. 8" Concrete Masonry Wall; 7/8"" metal furring + 5/8" gypsum board on both sides. 12" Precast Concrete Wall;See floor plan for any added veneer or furring. 8" Precast Concrete Wall;See floor plan for any added veneer or furring. 7 3/4" 7 1/2" 8 5/8" 8" 8 1/4" 8 1/2" 9 3/4" 9 1/2" 6" 8" 10" 1' 1'-4" 3 5/8" 5 5/8" 7 5/8" 9 1/8" 10 1/4" 12" 8" 1-5/8" Metal stud wall, min. 16" o.c.; 5/8" gypsum board on one side. 2 1/4" 2-1/2" Metal stud wall, min. 16" o.c.; 5/8" gypsum board on one side; 1" space on one side. 4 1/8" 2-1/2" CH studs, min. 24" o.c.; (2) layers of 1/2" gypsum board on one side; 1" liner panel on one side. Designation with " i " requires 1" sound batt insulation added in cavity. 3 1/2" 2-1/2" Metal stud wall, min. 16" o.c.; 5/8" Moisture and Mold Resistant board on one side; 1" space on one side. 4 1/8" VBRK S8Di VBRK2 VMS S8A i METAL 8" Metal stud wall, min. 16" o.c.; 5/8" gypsum board on both sides, with batt insulation (see specifications for requirements). Brick veneer with a 1-1/2" air space. Brick veneer with a 2-1/4" air space. 9 1/4" 5 1/8" 5 7/8" Manufactured stone veneer with a 2-1/4" air space. 5 7/8" Metal Wall Panel 1 1/4" 8" Metal stud wall, min. 16" o.c.; 5/8" exterior sheathing, with batt insulation (see specifications for requirements). 8 5/8" Thickness Wall Legend Plan View Section View Brief Description S3.5Bi WALL TYPE NOTATION 1. Wall tags with additional dimensional text indicate wall height, such as: Any wall tags without such additional noting are to be assumed to go to underside of structural deck above or as indicated in associated wall sections. 2. Some walls may have more than one wall type tag, signifying that: a. either the wall has a core wall type with additional wall materials required or, b. the wall is a given wall type at the floor (to a certain height), then changes to another wall type above. 3. Any wall type designation showing a letter " i " indicates that insulation is required. See either Schedule and/or specification for wall insulation type required. 4. Any wall sheathing indicated on a wall type shall be exterior sheathing when the wall is used for an exterior wall. This includes porches, mechanical rooms, elevator shafts and machine rooms and parking level spaces. +42" AFF CJ MBRK 2EJ WALL JOINT LEGEND AND NOTES Control Joint: Reference S-Series drawings for structural requirements in masonry joints. When the wall is a fire rated wall (reference Life Safety Sheets), provide the required fire sealant assembly at the joint per the specifications and assemblies shown in the Architectural details. When there are questions about the location of the joint due to masonry conflicts, coordination with other wall types or choosing appropiate fire assembly sealants, notify the Architect. See details regarding both masonry walls and stud framed walls. Masonry Break: Symbol indicates the location for an intentional beginning and start of the running bond. When there is an elevation of the wall provided, refer to the masonry joint lines as an indication of the intent. Reference S-Series drawings for structural requirements (reinforcement) in masonry connections. Not all masonry breaks are shown on the plan. Notify the Architect when there is a question or conflict. 2" Expansion joint Thickness Wall Legend Plan View Section View Brief Description S3.5A S3.5Bi S6Bi S6Di S6B S6C S6Ci S3.5B S3.5E S3.5F S3.5Fi S3.5G S3.5Gi S6E S6F S6Fi S6G S6Gi S4H S6H S2.5Ji S2.5Ki S2.5Li S2.5Mi S6A 6" Metal stud wall, min. 16" o.c.; 5/8" gypsum board, 2 layers on both sides. 6" Metal stud wall, min. 16" o.c.; 5/8" gypsum board, 2 layers on both sides, with batt insulation (see specification for requirements) 3-5/8" Metal stud wall, min. 16" o.c.; 5/8" gypsum board on both sides. 3-5/8" Metal stud wall, min. 16" o.c.; 5/8" Moisture and Mold Resistant board, on one side. 3-5/8" Metal stud wall, min. 16" o.c.; 5/8" Moisture and Mold Resistant board, on one side, 5/8" gypsum, on one side. 3-5/8" Metal stud wall, min. 16" o.c.; 5/8" Moisture and Mold Resistant board, on one side, 5/8" gypsum, on one side, with batt insulation (see specifications for requirements). 3-5/8" Metal stud wall, min. 16" o.c.; 5/8" Moisture and Mold Resistant board on both sides. 3-5/8" Metal stud wall, min. 16" o.c.; 5/8" Moisture and Mold Resistant board on both sides, with batt insulation (see specifications for requirements). 6" Metal stud wall, min. 16" o.c.; 5/8" Moisture and Mold Resistant board, on one side. 6" Metal stud wall, min. 16" o.c.; 5/8" Moisture and Mold Resistant board, on one side, 5/8" gypsum, on one side. 6" Metal stud wall, min. 16" o.c.; 5/8" Moisture and Mold Resistant board, on one side, 5/8" gypsum, on one side, with batt insulation (see specifications for requirements). 6" Metal stud wall, min. 16" o.c.; 5/8" Moisture and Mold Resistant board on both sides. 6" Metal stud wall, min. 16" o.c.; 5/8" Moisture and Mold Resistant board on both sides, with batt insulation (see specifications for requirements). 3-5/8" Metal stud wall, min. 16" o.c.; 5/8" gypsum board on one side. 3-5/8" Metal stud wall, min. 16" o.c.; 5/8" gypsum board on both sides, with batt insulation (see specifications for requirements). 6" Metal stud wall, min. 16" o.c.; 5/8" gypsum board on both sides. 6" Metal stud wall, min. 16" o.c.; 5/8" gypsum board on both sides, with batt insulation (see specifications for requirements). 6" Metal stud wall, min. 16" o.c.; 5/8" gypsum board on one side; 5/8" exterior sheathing, with batt insulation (see specifications for requirements). 4 1/4" 4 7/8" 4 7/8" 4 1/4" 4 7/8" 4 7/8" 4 7/8" 4 7/8" 7 1/4" 7 1/4" 8 1/2" 8 1/2" 7 1/4" 6 5/8" 7 1/4" 7 1/4" 7 1/4" 7 1/4" 4" CH studs, min. 24" o.c.; (2) layers of 1/2" gypsum board on one side; 1" liner panel on one side. Designation with " i " requires 3" mineral fiber insulation added in cavity. 5" 6 5/8" 6" Metal stud wall, min. 16" o.c.; 5/8" gypsum board on one side. 7" 6" CH studs, min. 24" o.c.; (2) layers of 1/2" gypsum board on one side; 1" liner panel on one side. Designation with " i " requires 3" mineral fiber insulation added in cavity. 2-1/2" Metal stud wall, min. 16" o.c.;(2) layers of 5/8" gypsum board on one side w/ batt insulation. 3 3/4" 2-1/2" Metal stud wall, min. 16" o.c.;(2) layers of 5/8" gypsum board on one side w/ additional 1-1/2" batt insulation (see specifications for requirements). 5 1/4" 2-1/2" Metal stud wall, min. 16" o.c.; 5/8" gypsum board; 5/8" Moisture and Mold Resistant board on one side w/ batt insulation. 3 3/4" 2-1/2" Metal stud wall, min. 16" o.c.; 5/8" gypsum board; 5/8" Moisture and Mold Resistant board on one side w/ additional 1-1/2" batt insulation (see specifications for requirements). 5 1/4" Thickness Wall Legend Plan View Section View Brief Description 1 04.21.06 JAW Bid Set: ALL Bldg A Bid Sets 1 02.07.09 Green REVISION: • IN THE WALL TYPE SCHEDULE: THE TERM "GREEN" BOARD IS CHANGED TO "MOISTURE AND MOLD RESISTANT" BOARD.