Loading...
HomeMy WebLinkAboutAA104 Fourth Floor OverallBID SET A.410 ISSUE, 12/29/08 Project: Developer: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: By: Sheet Title: CARMEL CITY CENTER Carmel, Indiana Building A Phase 1 COPYRIGHT & OWNERSHIP OF DOCUMENTS Architecture / Project Management: Project Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue Date PEDCOR DESIGN GROUP LLC 0502.00 AA104 Fourth Floor Overall Bid Set 04.21.06 THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP,LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP,LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP,LLC. © COPYRIGHT 2006, 2007, 2008 JAMES R. STUTZMAN, AIA, CARMEL, INDIANA SCALE: NTS PLAN NORTH 28 22 16 H M AREA A AREA C AREA B R KEY PLAN BLDG A Tuesday, January 6, 2009; ALLDATA:MS:DESIGN:PROJECTS:CARMEL CITY CENTER:CCC Drawings:CCC Construction Doc:Building A:A.General:BLDG A LAYOUT DRAWINGS:BLDG A Floor Plans.pln All Bid Sets 8 AA703 DIRECTION OF STRUCTURAL SLOPED ROOF DECK (EITHER STEEL OR COMPOSITE). # SINGLE ROOF DRAIN , SEE SHEET AA702. F # DIRECTION OF SLOPED STRUCTURAL DECK (PARTIALLY) UNDER TAPERED ROOF INSULATION. DOUBLE ROOF DRAIN, SEE SHEET AA702. T DIRECTION OF TAPERED ROOF INSULATION. S ROOF DRAIN KEY (#) : A = DOMED DRAIN B = FLAT AREA DRAIN C = FLAT DRAIN UNDER PAVER SYSTEM TAPERED ROOF INSULATION. TYPICAL SLOPE IS 1/4" PER FOOT. TAPERED ROOF INSULATION OVER TAPERED FIELD OF ROOF INSULATION. TYPICAL SLOPE IS 1/4" PER FOOT. FLAT ROOF INSULATION FILLER. WALKING PADS SCOPE OF ROOF BID SET A.220. W41 W41 W23 W23 S6Di H H.5 J J.5 K K.5 L L.1 L.5 L.9 M M.5 M.9 N N.1 N.5 P P.1 P.5 Q Q.5 R R.1 R.5 S 28 27.6 27 26 25 24 23 22 R.3 23.6 15.5 21 20 19 18 17 16 15 26.4 26.5 21.4 18.1 R.6 16.1 J.4 24.1 J.1 R.2 23.1 21.9 19.9 17.1 16.9 28.2 28.1 21.5 J.05 25.7 25.4 J.2J.3 26.9 26.3 27.5 25.3 H H.5 J J.5 K K.5 L L.1 L.5 L.9 M M.5 M.9 N N.1 N.5 P P.1 P.5 Q Q.2 Q.5 R R.1 R.5 S 28 27.6 27 26 25 24 23 22 R.3 23.6 15.5 21 20 19 18 17 16 15 26.4 26.5 21.4 18.1 R.6 16.1 J.4 24.1 J.1 R.2 23.1 21.9 19.9 17.1 16.9 28.2 28.1 21.5 J.05 25.7 25.4 J.2J.3 26.9 26.3 27.5 25.3 Q.2 R.6 AREA B AREA C AREA A AREA B AREA B AREA C AREA A AREA B H H.5 J J.5 K K.5 L L.1 L.5 L.9 M M.5 M.9 N N.1 N.5 P P.1 P.5 Q Q.5 R R.1 R.5 S 28 27.6 27 26 25 24 23 22 R.3 23.6 15.5 21 20 19 18 17 16 15 26.4 26.5 21.4 18.1 R.6 16.1 J.4 24.1 J.1 R.2 23.1 21.9 19.9 17.1 16.9 28.2 28.1 21.5 J.05 25.7 25.4 J.2J.3 26.9 26.3 27.5 25.3 Q.2 3'-4" 3'-10" 9'-6" 9'-6" 3'-10" 3'-4" Roof Second floor Roof Second floor Roof Second floor Roof Second floor Roof Second floor Roof Second floor CORRIDOR D TA5A-4 CORRIDOR F TA4A-4 CORRIDOR E Stair SA5 Elev EA8 Stair SA6 ELEVATOR LOBBY K Exhaust Shaft XA2 Exhaust Shaft Mech Shaft XA3 MA4 Mech Shaft MA3 two bedroom +2 baths 419 one bedroom +1 bath 426 two bedroom + 2 baths 414 one bedroom +1 bath 429 two bedroom +2 baths 427 two bedroom +2 baths 413 two bedroom +2 baths 411 two bedroom +2 bath 428 one bedroom + 1 bath 424 two bedroom+2 bath 412 two bedroom +2 bath 430 two bedroom +2 baths 417 three bedroom +2 baths 416 two bedroom +2 baths 418 two bedroom +2 bath 431 two bedroom +2 baths 421 two bedroom +2 baths 420 Mtr Rm 4A-1 Mtr Rm 4A-2 ELEV EA4 ELEV EA5 MECH SHAFT MA2 ELEVATOR LOBBY XXX CORRIDOR G Stair SA3 two bedroom +2 baths 422 two bedroom +2 baths 423 STAIR SA2 three bedroom +2-1/2 baths 415 CORRIDOR J Elev EA9 Mtr Rm 4A-3 Exh. XA1 CORRIDOR A STAIR SA1 one bedroom+1 bath 410 two bedroom +2 baths 401 two bedroom +2 baths 402 two bedroom +2 baths 403 two bedroom +2 baths 404 two bedroom +2 baths 406 two bedroom +2 baths 408 three bedroom +2-1/2 bath 407 two bedroom +2 baths 409 MECH SHAFT MA1 ELEV EA3 ELEV EA2 TA2-4 one bedroom + 1 bath 425 one bedroom+1-1/2 bath 405 IT H SCALE: 1/16" = 1'-0" 1 Fourth Floor Plan AA104 0 8' 16' 32' 28.228.1 28 27.6 27.5 27 26.9 26.26.5 26.4 3 26 25.7 25.4 25.3 25 24.1 24 23.6 23.1 23 22 21.9 21.5 21.4 21 20 19.9 19 18.1 18 17.1 17 16.9 16.1 16 15.5 15 AREA B AREA C AREA A AREA B two bedroom +2 baths 421 H H.5 J J.5 K K.5 L L.1 L.5 L.9 M M.5 M.9 N N.1 N.5 P P.1 P.5 Q Q.5 R R.1 R.5 S 28 27.6 27 26 25 24 23 22 R.3 23.6 15.5 21 20 19 18 17 16 15 26.4 26.5 21.4 18.1 R.6 16.1 J.4 24.1 J.1 R.2 23.1 21.9 19.9 17.1 16.9 28.2 28.1 21.5 J.05 25.7 25.4 J.2J.3 26.9 26.3 27.5 25.3 Q.2 Roof Plan Legend 6.08.07 12.29.08 DJS JAW