Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
AA105A Fifth Floor - Area A
30 31 32 33 34 BID SET A.500, CCC.A.ASI.2, 5/15/09 PLUMBING FIXTURE DIMENSION UPDATE A.ASI.003, 05/29/09 STOREFRONT AND WALL BASE UPDATES 6/29/09 A.ASI.004, 06/10/09 SHEET METAL FLASHING & METAL ROOF COLOR UPDATE, 08/17/09 Project: Developer: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: By: Sheet Title: CARMEL CITY CENTER Carmel, Indiana Building A Phase 1 COPYRIGHT & OWNERSHIP OF DOCUMENTS Architecture / Project Management: Project Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue Date PEDCOR DESIGN GROUP LLC 0502.00 AA105A Fifth Floor - Area A Bid Set !"#$%#!& THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP,LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2006, 2007, 2008, 2009, JAMES R. STUTZMAN, AIA, CARMEL, INDIANA !"#$%&’()! !"#$%$&’() !" !! #$ % & ’()’*’ ’()’*+ ’()’*, ( !"#$%&’( )&*+$’ Wednesday, August 19, 2009; alldata:MS:DESIGN:PROJECTS:CARMEL CITY CENTER:CCC Drawings:CCC Construction Doc:Building A:A.General:BLDG A LAYOUT DRAWINGS:BLDG A Floor Plans.pln All Bid Sets 8 AA703 DIRECTION OF STRUCTURAL SLOPED ROOF DECK (EITHER STEEL OR COMPOSITE). # SINGLE ROOF DRAIN , SEE SHEET AA702. F # DIRECTION OF SLOPED STRUCTURAL DECK (PARTIALLY) UNDER TAPERED ROOF INSULATION. DOUBLE ROOF DRAIN, SEE SHEET AA702. T DIRECTION OF TAPERED ROOF INSULATION. S ROOF DRAIN KEY (#) : A = DOMED DRAIN B = FLAT AREA DRAIN C = FLAT DRAIN UNDER PAVER SYSTEM TAPERED ROOF INSULATION. TYPICAL SLOPE IS 1/4" PER FOOT. TAPERED ROOF INSULATION OVER TAPERED FIELD OF ROOF INSULATION. TYPICAL SLOPE IS 1/4" PER FOOT. FLAT ROOF INSULATION FILLER. WALKING PADS SCOPE OF ROOF BID SET A.220. PEDESTAL PAVERS OVER ROOF SYSTEM. 34 34 H H.5 J J.05 J.1 J.2 J.3 J.4 J.5 K K.5 L L.1 L.5 L.9 M A8 S6Ci S6Ci SA1-R S6Ci MA1-R L02 SA2-5 S6Ci S6Di EA2M S6Di L04 S6Di S6Ci S6Ci S6Ci S6Ci S6Di S6Di S6Ci S4Hi S4Hi S4Hi A-509 S3.5Bi MA-A1 S6Bi A-501 S3.5Bi S6Di S6Di S3.5B S6Di S3.5Bi A-5D A-5K MA-A2 S6Bi S6Di S6Ci S6Ci SA1-R S6Ci MA1-R L02 SA2-5 S6Ci S6Di EA2M S6Di L04 S6Di S6Ci S6Ci S6Ci S6Ci S6Di S6Di S6Ci S4Hi S4Hi S4Hi A-511 AREA A AREA B 1 2 3 9 AA702 9 AA702 9 AA702 1 AA703 2 AA704 1 AA703 1 AA703 2 AA704 1 AA703 9 AA702 9 AA702 9 AA702 9 AA702 9 AA702 9 AA702 9 AA702 2 AA704 1 AA703 2 AA704 1 AA703 1 AA703 8 AA702 SIM. 1 2 3 4 AA161 3 AA162 1 AA166 3 AA167 4 AA162 5 AA161 2 AA166 4 AA167 6 4 AA420 AA415 5 AA420 1 AA431 3 AA431 4 AA431 5 AA168 2'-8" 4'-8" 2'-8" 11'-2" 4 1/2" 2'-11" 10" 2'-11" 10" 2'-11" 4 1/2" 1'-9" 1'-1" 3 1/2" 3'-0" 3 1/2" 2'-0" 3 1/2" 3 5/8" 4'-6 1/4" 3 5/8" 31'-10 3/16" 6" 30'-8 3/8" 6" 6" 22'-8" 6" 6'-4 1/2" 6" 2'-8" 4'-8" 2'-8" 11'-2" 4 1/2" 2'-11" 10" 2'-11" 10" 2'-11" 4 1/2" 1'-9" 1'-1" 3 1/2" 3'-0" 3 1/2" 2'-0" 3 1/2" 6" 14'-7 1/2" 6" 5'-6 1/2" 6" 6" 14'-7 1/2" 6" 5'-6 1/2" 6" 7'-7 3/4" 2 AA420 1 AA416 2 AA416 1 AA410 10 AA420 2 AA410 3 AA410 11 18 18 19 SUPPLY EXHAUST 19 1 1 1 1 SUPPLY EXHAUST A A A A A A SIM. 6500 CFM 3150 LBS 15D ERV SIM. ! T S S S T T S S Roof Second floor Roof Second floor Hood Shaft EA2 M Machine Room Roof 6500 CFM 3150 LBS 15D ERV ! LOFT 1 LO9 LOFT 1 LO1 Stair SA1 MECH. RM MA-A1 MECH. RM MA-A2 Mechanical Shaft MA1 Mech. Rm MA1-R two bedroom +2 baths 511 STAIR SA2 L01 6500 CFM 3150 LBS 15D ERV W28 W28 6 AA416 11 14 17 S T S S S S S S S T T T T T T T T 28.2 28.1 28 27.6 27.5 27 26.9 26.5 26.4 26.3 26 25.7 25.4 25.3 25 24.1 24 23.6 23.1 23 28 27.6 27 26 25 24 23 23.6 26.4 26.5 24.1 23.1 28.2 28.1 25.7 25.4 26.9 26.3 27.5 25.3 UNIT 11 UNIT L09 UNIT L01 RESIDENTAL FLOOR PLAN NOTES 1 Dimension is to inside face of shaft. 2 Envac disposal door 3 Envac waste removal chute 4 Reference Bid Set A.200, AA400 sheet series for location of elevator door openings. 5 Dens-Glass Gold Sheathing 6 Dimension is from face of stud to column centerline. 7 Align corner of stud to south face of exterior stud. 8 Reserved 9 Align face of furring to face of stud wall. 10 Refer to Bid Set A.500 Sheet IAxxx for wall types at pilasters. 11 Expansion joint. 12 Align inside face of gypsum board is to the floor opening at Stair, Envac and Grill Exhaust shafts at three sides. Dimensions are to inside face of stud at shaft. Verify that these dimensions match up to floor opening. Advise Architect of conflicts. 13 Provide exterior sheathing at the expansion joint side of wall in lieu of interior gypsum board. Align face of exterior sheathing edge of slab. 14 Stainless steel checker plate threshold at door sill (6" above expansion joint). 15 Membrane roofing. Membrane roofing also present at Green Roof where designated. Reference details and specifications for membrane and plant material requirements. 16 See facade drawing for roofing type and material. 17 Condensing units, see Detail /AA704 for back support detail. 18 Reference plumbing contract for locations of plumbing stacks. 19 Refer to detail 9/AA704 for typical roof composition. 20 Refer to detail 4/AA704 for typical fire rated roof composition. 21 Refer to detail 10/AA704 for typical fire rated standing seam roof compostion. GENERAL NOTES 1. Review sheet AA504 for column details pertaining to fire protection, CMU and AAC wall construction at columns. Review sheets AA521-AA525 for additional wall interfacing and plumbing coordination. 2. Refer to shaft drawings for walls of elevator, stair and mechanical shafts. 3. Reference 1/4" scale floor plans for specific exterior wall dimensions. 4. Reference AA.400 series drawings for specific shaft wall dimensions not shown on overall floor plans. 5. Reference I-series sheets for the layout of residential unit partitions. 6. Stud wall dimensions are typically to face of stud, unless otherwise noted. 7. For the 3rd, 4th, and 5th floor plans, reference the 2nd floor unit plan for dimensions. Roof Plan Legend SCALE: 1/8" = 1'-0" 1 Fifth Floor Unit Plan AA105A 0 4' 8' 16' 3.29.07 JPM BAB 08/17/09