Loading...
HomeMy WebLinkAboutAA106C Sixth Floor - Area CProject: Developer: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: By: Sheet Title: CARMEL CITY CENTER Carmel, Indiana Building A Phase 1 COPYRIGHT & OWNERSHIP OF DOCUMENTS Architecture / Project Management: Project Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue Date PEDCOR DESIGN GROUP LLC 0502.00 AA106C Sixth Floor - Area C Bid Set 04.21.06 THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP,LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP,LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP,LLC. © COPYRIGHT 2006, 2007, 2008 JAMES R. STUTZMAN, AIA, CARMEL, INDIANA 25 26 27 28 29 BID SET A.410 ISSUE, 12/29/08 BID SET A.210.ASI.01, 01/20/09 (AFFECTING A.300, A.310, A.400) WINDOW SCHEDULE UPDATE, 2/02/09 BID SET A.300, 02/07/09 MASONRY AND EIFS UPDATE BID SET A.300, 02/27/09 MASONRY AND EIFS UPDATE 2 A.300.ASI.004, 03/08/09 CCC.A.ASI.1, 5.20.09 RFI UPDATES, PUBLIC WAYS, ROOF UPDATES SCALE: NTS PLAN NORTH 28 22 16 H M AREA A AREA C AREA B R KEY PLAN BLDG A Friday, May 22, 2009; ALLDATA:MS:DESIGN:PROJECTS:CARMEL CITY CENTER:CCC Drawings:CCC Construction Doc:Building A:A.General:BLDG A LAYOUT DRAWINGS:BLDG A Floor Plans.pln All Bid Sets 8 AA703 DIRECTION OF STRUCTURAL SLOPED ROOF DECK (EITHER STEEL OR COMPOSITE). # SINGLE ROOF DRAIN , SEE SHEET AA702. F # DIRECTION OF SLOPED STRUCTURAL DECK (PARTIALLY) UNDER TAPERED ROOF INSULATION. DOUBLE ROOF DRAIN, SEE SHEET AA702. T DIRECTION OF TAPERED ROOF INSULATION. S ROOF DRAIN KEY (#) : A = DOMED DRAIN B = FLAT AREA DRAIN C = FLAT DRAIN UNDER PAVER SYSTEM TAPERED ROOF INSULATION. TYPICAL SLOPE IS 1/4" PER FOOT. TAPERED ROOF INSULATION OVER TAPERED FIELD OF ROOF INSULATION. TYPICAL SLOPE IS 1/4" PER FOOT. FLAT ROOF INSULATION FILLER. WALKING PADS SCOPE OF ROOF BID SET A.220. PEDESTAL PAVERS OVER ROOF SYSTEM. 29 29 22 21 20 21.4 21.9 19.9 21.5 P P.1 P.5 Q Q.2 Q.5 R R.1 R.2 R.3 R.5 R.6 S SA5-6 S6Ci S6Ci S6Ci A8A A8A A8 A8 A8D S3.5Bi A-605B A-605A S3.5Bi S3.5A S3.5Bi A-601B S3.5Bi S6Di S6Di S3.5A DR09 W11 W12 W11 DR12 DR11 W28 W28 D27 D27 D27 S6Di VEFIS W47 S6C AREA B AREA C AREA B AREA C 3 AA434 1 AA434 7 AA120 2 AA151 6 AA422 4 AA418 1 AA135 4 AA432 1 AA260 1'-10"MIN. 3 5/8" 3 5/8" 3 5/8" 3 5/8" 7'-43/8" 3 5/8" 6 1/4" 12'-3 1/8" 16'-5 9/16" 1'-8 1/4" 3 3/4" 4'-1 13/16" 2'-8" 2 AA422 1 1 10 16 C Sloping Roof Roof Above Fifth floor Roof Second floor Roof Second floor TYP. TYP. 1'-9" AFF SIM. CORRIDOR 600A PENTHOUSE 605 Stair SA5 PENTHOUSE 601 Mech Shaft MA3 Porch 601A Porch 605a Porch 605B FP5 PENTHOUSE 05 GENERAL NOTES 1. Review sheet AA504 for column details pertaining to fire protection, CMU and AAC wall construction at columns. Review sheets AA521-AA525 for additional wall interfacing and plumbing coordination. 2. Refer to shaft drawings for walls of elevator, stair and mechanical shafts. 3. Reference 1/4" scale floor plans for specific exterior wall dimensions. 4. Reference AA.400 series drawings for specific shaft wall dimensions not shown on overall floor plans. 5. Reference I-series sheets for the layout of residential unit partitions. 6. Stud wall dimensions are typically to face of stud, unless otherwise noted. 7. For the 3rd, 4th, and 5th floor plans, reference the 2nd floor unit plan for dimensions. RESIDENTAL FLOOR PLAN NOTES 1 Dimension is to inside face of shaft. 2 Envac disposal door 3 Envac waste removal chute 4 Reference Bid Set A.200, AA400 sheet series for location of elevator door openings. 5 Dens-Glass Gold Sheathing 6 Dimension is from face of stud to column centerline. 7 Align corner of stud to south face of exterior stud. 8 Reserved 9 Align face of furring to face of stud wall. 10 Refer to Bid Set A.500 Sheet IAxxx for wall types at pilasters. 11 Expansion joint. 12 Align inside face of gypsum board is to the floor opening at Stair, Envac and Grill Exhaust shafts at three sides. Dimensions are to inside face of stud at shaft. Verify that these dimensions match up to floor opening. Advise Architect of conflicts. 13 Provide exterior sheathing at the expansion joint side of wall in lieu of interior gypsum board. Align face of exterior sheathing edge of slab. 14 Stainless steel checker plate threshold at door sill (6" above expansion joint). 15 Membrane roofing. Membrane roofing also present at Green Roof where designated. Reference details and specifications for membrane and plant material requirements. 16 See facade drawing for roofing type and material. 17 Condensing units, see Detail /AA704 for back support detail. 18 Reference plumbing contract for locations of plumbing stacks. 19 Refer to detail 9/AA704 for typical roof composition. 20 Refer to detail 4/AA704 for typical fire rated roof composition. 21 Refer to detail 10/AA704 for typical fire rated standing seam roof compostion. SCALE: 1/8" = 1'-0" 1 Sixth Floor Unit Plan AA106C 0 4' 8' 16' 3.29.07 DJS JAW 02.07.09 Roof Plan Legend