Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
AA302 Building Sections
Project: Developer: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: By: Sheet Title: CARMEL CITY CENTER Carmel, Indiana Building A Phase 1 COPYRIGHT & OWNERSHIP OF DOCUMENTS Architecture / Project Management: Project Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue Date PEDCOR DESIGN GROUP LLC 0502.00 AA302 Building Sections Bid Set 04.21.06 THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP,LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP,LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP,LLC. © COPYRIGHT 2006, 2007, 2008 JAMES R. STUTZMAN, AIA, CARMEL, INDIANA 13 12 11 14 15 16 CONSTRUCTION SET A.100; A.200 06/29/07 BID SET A.400 ISSUE, 08/17/07 A.100.ASI.012, A.200.ASI.001, 09/13/07 A.100.ASI.013, 12/14/07 BID SET A.400 RE-ISSUE, 09/19/08 BID SET A.210 ISSUE, 05/01/08 BID SET A.410 ISSUE, XX/XX/08 BID SET A.300 C.1 ISSUE, 06/27/08 SCALE: NTS PLAN NORTH 28 22 16 H M AREA A AREA C AREA B R KEY PLAN BLDG A Thursday, September 25, 2008; alldata:MS:DESIGN:PROJECTS:CARMEL CITY CENTER:CCC Drawings:CCC Construction Doc:Building A:A.100:Bid Set A.100.pln 13 5 AA307 - FIRE PROTECTION ON ALL STEEL STRUCTURE STAIR SYSTEM, N.I.C. P P.1 P.5 Q Q.2 Q.5 R R.1 R.2 R.3 R.5 R.6 S 1 AA304 5 - AA307 - 3 AA301 1 - AA305 - 6 AA502 6 AA502 CONC. BEAM, REF. STRUCTURAL CONC. WALL, REF. STRUCTURAL CONC. SLAB, REF. STRUCTURAL UNDER SLAB DRAINAGE, REF. MEP SERIES DRAWINGS CONC. FOOTING SYSTEM, REF. STRUCTURAL CMU BOND BEAM PRECAST CMU STRUCTURAL SYSTEM & TOPPING, N.I.C. PAVER SUBSTRATE SYSTEM, N.I.C. PAVER SYSTEM, N.I.C. WATERPROOFING FOUNDATION DRAINAGE SYSTEM, REF. CIVIL C.I.P. SLAB & BEAM, REF. STRUCTURAL N.I.C CMU, WITH PLASTER FINISH WATERSTOP, TYP. BID SET A.100 SA5 STAIR CONC. SLAB & GRANULAR FILL, REF. STRUCTURAL POURRED CONC. STAIR, REF. STRUCTURAL LIMESTONE CAP, BRICK VENEER, N.I.C. FIRE PROTECTION ON ALL STEEL STRUCTURE WATERPROOFING FOUNDATION DRAINAGE SYSTEM, REF. CIVIL STAIR SYSTEM, N.I.C. CMU, WITH PLASTER FINISH FIRE SEALANT @ ALL RATED ASSEMBLIES, TYP. FUTURE SLAB BY TENANT SCALE: 1/64" = 1'-0" SECTION KEY R R.1 S 1 AA304 3 - AA304 - 1 AA305 - 3 AA301 5 - AA307 - 6 AA502 6 AA502 6 AA502 P P.1 P.5 Q Q.2 Q.5 R R.1 R.2 R.3 R.5 R.6 S 13 AA501 CONC. SLAB & GRANULAR FILL, REF. STRUCTURAL CONC. WALL, REF. STRUCTURAL CONC. SLAB, REF. STRUCTURAL CONC. FOOTING SYSTEM, REF. STRUCTURAL FOUNDATION DRAINAGE SYSTEM, REF. PLUMBING DWGS. CONC. BEAM BEYOND, REF. STRUCTURAL MASONRY & LIMESTONE VENEER, TREADS & RISERS, N.I.C. LIMESTONE CAP, BRICK VENEER, N.I.C. RAILINGS, N.I.C. FIRE PROTECTION ON ALL STEEL STRUCTURE COORDINATE LADDER LOCATION W/ ELEVATOR MANUFACTURER PAVER SUBSTRATE SYSTEM, N.I.C. FOUNDATION DRAINAGE SYSTEM, REF. PLUMBING DWGS. PRECAST STRUCTURAL SYSTEM & TOPPING, N.I.C. C.I.P. SLAB & BEAM, REF. STRUCTURAL UNDER SLAB DRAINAGE, REF. MEP SERIES DRAWINGS RIGID INSULATION; PERIMETER FOUNDATION WALL MISC. METALS, GRATING & RAILINGS, N.I.C. SHT. MTL. ENCLOSURE AROUND DUCT, REF. MECH. DWGS. WATERPROOFING WATERPROOFING BID N.I.C. SET A-1 FUTURE SLAB BY TENANT HIGHEST POINT OF SLOPED PIT FLOOR WATERSTOP, TYP. COORDINATE SUMP PIT LOCATION W/ ELEVATOR MANUFACTURER, PROVIDE STEEL GRATE COVER & FRAME DUCT TO FAN EQUIPMENT, REF. MECH. DWGS. C.I.P. STAIR, REF. STRUCTURAL PAVER SYSTEM, N.I.C. WATERPROOFING, SEE SPEC. FOR ALTERNATE @ VERTICAL WALLS (INCLUDING EXTERIOR RETAINING WALLS) ROLLING FIRE SHUTTER DOOR MECHANICAL LOUVERS CMU FIRE SEALANT @ ALL RATED ASSEMBLIES, TYP. WATERPROOFING, SEE SPEC. FOR ALTERNATE @ VERTICAL WALLS (INCLUDING EXTERIOR RETAINING WALLS) WATERPROOFING, SEE SPEC. FOR ALTERNATE @ VERTICAL WALLS (INCLUDING EXTERIOR RETAINING WALLS) FOUNDATION DRAINAGE SYSTEM, REF. PLUMBING DWGS. 1ELEVATOR SHAFTS EA9 PA13 EA8 1MECHANICAL SHAFT MA3 FUTURE TENANT X-XX FAN ROOM MA3 SCALE: 1/64" = 1'-0" SECTION KEY Q.5 R R.1 5 AA307 - H H.5 J J.05 J.1 J.2 J.3 J.4 J.5 K K.5 L L.1 L.5 L.9 M M.5 M.9 N N.1 N.5 P P.1 P.5 Q Q.2 Q.5 R R.1 R.2 R.3 R.5 R.6 S 2 AA304 3 AA301 1 - AA305 3 - AA306 1 - AA307 2 - AA306 1 - AA306 - 6 AA502 14 AA501 WATERSTOP, TYP. CONC. FOOTING SYSTEM, REF. STRUCTURAL FIRE PROTECTION ON ALL STEEL STRUCTURE CMU PRECAST STRUCTURAL SYSTEM & TOPPING, N.I.C. BID SETS A.100 A.300 A.400 BACKFILL FOUNDATION DRAINAGE SYSTEM, REF. CIVIL WATERPROOFING BID SETS A.300 A.400 PAVER SUBSTRATE SYSTEM, N.I.C. C.I.P. STAIR, REF. STRUCTURAL CMU FIRE SEALANT @ ALL RATED ASSEMBLIES, TYP. CMU C.I.P. SLAB & BEAM FUTURE TENANT X-XX UNDER SLAB DRAINAGE, REF. MEP SERIES DRAWINGS FIRE PROTECTION ON ALL STEEL STRUCTURE CONC. FOOTING SYSTEM, REF. STRUCTURAL WATERSTOP, TYP. CONC. WALL, REF. STRUCTURAL CONC. SLAB, REF. STRUCTURAL BRICK VENEER, N.I.C. CONC. WALL, REF. STRUCTURAL CONC. SLAB, REF. STRUCTURAL STAIR TREADS & RISERS, N.I.C. BRICK VENEER, N.I.C. PAVER SYSTEM, N.I.C. UNDER SLAB DRAINAGE, REF. MEP SERIES DRAWINGS RIGID INSULATION; PERIMETER FOUNDATION WALL WATERPROOFING, SEE SPEC. FOR ALTERNATE @ VERTICAL WALLS (INCLUDING EXTERIOR RETAINING WALLS) SEE 9/AA502 FOUNDATION DRAINAGE SYSTEM, REF. PLUMBING DWGS. CONC. SLAB & GRANULAR FILL, REF. STRUCTURAL FUTURE SLAB BY TENANT SCALE: 1/64" = 1'-0" SECTION KEY 5 AA307 - 3 AA301 - FIRE PROTECTION ON ALL STEEL STRUCTURE 2 AA304 BID SETS A.100 A.300 A.400 BID SETS A.300 A.400 FIRE PROTECTION ON ALL STEEL STRUCTURE BRICK VENEER, N.I.C. S 6'-101/4" -13'-4" BTM of Alcove -7'-4" Top Arch SEE AA206 R 3'-3" EL. = 2'-0" (850.00') EL. = 0'-0" (848.00') EL. = -0'-10" (847.17') EL. = -13'-0" (835.00') EL. = -17'-9" (830.25') EL. = -17'-6" (830.50') EL. = SEE STRUCTURAL T/PLAZA SLAB T/ FIN. FIRST FLOOR B/ PLAZA SLAB T/FOOTING T/HIGH PT. OF SLAB T/FOUNDATION WALL T/LOWER RETAIL F.F. EL. = 2'-0" (850.00') EL. = 0'-0" (848.00') EL. = -0'-10" (847.17') EL. = -13'-0" (835.00') EL. = -17'-9" (830.25') EL. = -17'-6" (830.50') EL. = SEE STRUCTURAL T/PLAZA SLAB T/ FIN. FIRST FLOOR B/ PLAZA SLAB T/FOOTING T/HIGH PT. OF SLAB T/FOUNDATION WALL T/LOWER RETAIL F.F. EL. = 2'-0" (850.00') EL. = 0'-0" (848.00') EL. = -0'-10" (847.17') EL. = -13'-0" (835.00') EL. = -17'-9" (830.25') EL. = -17'-6" (830.50') EL. = SEE STRUCTURAL T/PLAZA SLAB T/ FIN. FIRST FLOOR B/ PLAZA SLAB T/FOOTING T/HIGH PT. OF SLAB T/FOUNDATION WALL T/LOWER RETAIL F.F. EL. = 2'-0" (850.00') EL. = 0'-0" (848.00') EL. = -0'-10" (847.17') EL. = -13'-0" (835.00') EL. = -17'-9" (830.25') EL. = -17'-6" (830.50') EL. = SEE STRUCTURAL T/PLAZA SLAB T/ FIN. FIRST FLOOR B/ PLAZA SLAB T/FOOTING T/HIGH PT. OF SLAB T/FOUNDATION WALL T/LOWER RETAIL F.F. SCALE: 1/4" = 1'-0" 4 E/W Cafe' Fireplace AA302 0 2' 4' 8' Q Q.2 Q.5 R 1 AA305 - 5 AA307 - 13 AA501 COORDINATE LADDER LOCATION W/ ELEVATOR MANUFACTURER MISC. METALS, GRATING & RAILINGS, N.I.C. SHT. MTL. ENCLOSURE AROUND DUCT, REF. MECH. DWGS. WATERPROOFING COORDINATE SUMP PIT LOCATION W/ ELEVATOR MANUFACTURER, PROVIDE STEEL GRATE COVER & FRAME DUCT TO FAN EQUIPMENT, REF. MECH. DWGS. ROLLING FIRE SHUTTER DOOR MECHANICAL LOUVERS CMU FIRE SEALANT @ ALL RATED ASSEMBLIES, TYP. 1ELEVATOR SHAFTS EA9 PA13 EA8 1MECHANICAL SHAFT MA3 FAN ROOM MA3 A.100,A.210, A.400 04.21.06 RJP, JDR, JAW JAW 09.19.08 14 AA501 WATERSTOP, TYPICAL CONC. FOOTING SYSTEM, REF. STRUCTURAL FOUNDATION DRAINAGE SYSTEM, REF. PLUMBING DWGS. LIMESTONE CAP, N.I.C. CONC. SLAB & GRANULAR FILL, REF. STRUCTURAL FOUNDATION DRAINAGE SYSTEM, REF. PLUMBING DWGS. C.I.P. STAIR, REF. STRUCTURAL WATERPROOFING, SEE SPEC. FOR ALTERNATE @ VERTICAL WALLS (INCLUDING EXTERIOR RETAINING WALLS) SEE 9/AA502 BRICK VENEER, N.I.C. SEE STRUCTURAL DRAWINGS FOR FOUNDATION WALL DETAILS RAILINGS, N.I.C. WATERPROOFING, SEE SPEC. FOR ALTERNATE @ VERTICAL WALLS (INCLUDING EXTERIOR RETAINING WALLS) SEE 9/AA502 FUTURE TENANT X-XX RIGID INSULATION; PERIMETER FOUNDATION WALL UNDER SLAB DRAINAGE, REF. MEP SERIES DRAWINGS FUTURE SLAB BY TENANT EL. = -13'-4" T/WALL GALV. STEEL ANGLE BID SETS A.100 A.300 A.400 WATERPROOFING, SEE SPEC. FOR ALTERNATE @ VERTICAL WALLS (INCLUDING EXTERIOR RETAINING WALLS) SEE 9/AA502 CONCRETE BLOCK, N.I.C. MASONRY & LIMESTONE VENEER, TREADS & RISERS, N.I.C. FOUNDATION DRAINAGE SYSTEM, REF. PLUMBING DWGS. 2" DIA. WEEP HOLES 4'-0" O.C. W/ STAINLESS STEEL MESH @ EACH END. EL. = -12'-2" T/LEDGE & T/WALL PAVER SYSTEM, N.I.C. STAIR SLAB TO HAVE A DOUBLE DEPTH TREAD UNDER BALUSTRADE THE WIDTH OF THE FOUNDATION WALL IT CAPS (SEE STAIR PLAN 2/AA402) EL. = -8'-6" T/C.I.P. WALL PAVER SYSTEM, N.I.C. PAVER SUBSTRATE SYSTEM, N.I.C. SCALE: 1/4" = 1'-0" 2 E/W BUILDING SECTION 20-21A AA302 0 2' 4' 8' 14 AA501 WATERSTOP, TYP. CONC. FOOTING SYSTEM, REF. STRUCTURAL BID SETS A.100 A.300 A.400 PAVER SUBSTRATE SYSTEM, N.I.C. C.I.P. STAIR, REF. STRUCTURAL BRICK VENEER, N.I.C. CONC. WALL, REF. STRUCTURAL CONC. SLAB, REF. STRUCTURAL STAIR TREADS & RISERS, N.I.C. PAVER SYSTEM, N.I.C. UNDER SLAB DRAINAGE, REF. MEP SERIES DRAWINGS RIGID INSULATION; PERIMETER FOUNDATION WALL WATERPROOFING, SEE SPEC. FOR ALTERNATE @ VERTICAL WALLS (INCLUDING EXTERIOR RETAINING WALLS) SEE 9/AA502 FOUNDATION DRAINAGE SYSTEM, REF. PLUMBING DWGS. CONC. SLAB & GRANULAR FILL, REF. STRUCTURAL FUTURE SLAB BY TENANT SCALE: 1/4" = 1'-0" 1 E/W BUILDING SECTION 24-25A AA302 0 2' 4' 8' 2 AA304 1 AA304 BID SETS A.300 A.400 FIRE PROTECTION ON ALL STEEL STRUCTURE CONC. SLAB, REF. STRUCTURAL CONC. WALL, REF. STRUCTURAL BID SETS A.100 A.300 A.400 CONC. BEAM BEYOND, REF. STRUCTURAL STAIR SLAB TO HAVE A DOUBLE DEPTH TREAD UNDER BALUSTRADE THE WIDTH OF THE FOUNDATION WALL IT CAPS (SEE STAIR PLAN 2/AA402) 5 AA307 - 3 AA301 - 1 AA305 - 5 AA307 - 2 AA304 1 AA304 14 AA501 WATERSTOP, TYPICAL CONC. FOOTING SYSTEM, REF. STRUCTURAL FOUNDATION DRAINAGE SYSTEM, REF. PLUMBING DWGS. BID SETS A.300 A.400 LIMESTONE CAP, N.I.C. CONC. SLAB & GRANULAR FILL, REF. STRUCTURAL FOUNDATION DRAINAGE SYSTEM, REF. PLUMBING DWGS. C.I.P. STAIR, REF. STRUCTURAL WATERPROOFING, SEE SPEC. FOR ALTERNATE @ VERTICAL WALLS (INCLUDING EXTERIOR RETAINING WALLS) SEE 9/AA502 BRICK VENEER, N.I.C. SEE STRUCTURAL DRAWINGS FOR FOUNDATION WALL DETAILS RAILINGS, N.I.C. WATERPROOFING, SEE SPEC. FOR ALTERNATE @ VERTICAL WALLS (INCLUDING EXTERIOR RETAINING WALLS) SEE 9/AA502 FIRE PROTECTION ON ALL STEEL STRUCTURE CONC. SLAB, REF. STRUCTURAL CONC. WALL, REF. STRUCTURAL FUTURE TENANT X-XX RIGID INSULATION; PERIMETER FOUNDATION WALL UNDER SLAB DRAINAGE, REF. MEP SERIES DRAWINGS FUTURE SLAB BY TENANT EL. = -13'-4" T/WALL GALV. STEEL ANGLE BID SETS A.100 A.300 A.400 WATERPROOFING, SEE SPEC. FOR ALTERNATE @ VERTICAL WALLS (INCLUDING EXTERIOR RETAINING WALLS) SEE 9/AA502 CONCRETE BLOCK, N.I.C. MASONRY & LIMESTONE VENEER, TREADS & RISERS, N.I.C. FOUNDATION DRAINAGE SYSTEM, REF. PLUMBING DWGS. 2" DIA. WEEP HOLES 4'-0" O.C. W/ STAINLESS STEEL MESH @ EACH END. EL. = -12'-2" T/LEDGE & T/WALL CONC. BEAM BEYOND, REF. STRUCTURAL STAIR SLAB TO HAVE A DOUBLE DEPTH TREAD UNDER BALUSTRADE THE WIDTH OF THE FOUNDATION WALL IT CAPS (SEE STAIR PLAN 2/AA402) PAVER SYSTEM, N.I.C. STAIR SLAB TO HAVE A DOUBLE DEPTH TREAD UNDER BALUSTRADE THE WIDTH OF THE FOUNDATION WALL IT CAPS (SEE STAIR PLAN 2/AA402) EL. = -8'-6" T/C.I.P. WALL PAVER SYSTEM, N.I.C. PAVER SUBSTRATE SYSTEM, N.I.C. R.5 R.6 S CMU, WITH PLASTER FINISH SA5 STAIR CMU, WITH PLASTER FINISH FIRE SEALANT @ ALL RATED ASSEMBLIES, TYP. FUTURE SLAB BY TENANT SCALE: 1/4" = 1'-0" 3 E/W BUILDING SECTION 20-21B AA302 0 2' 4' 8' BRICK VENEER, N.I.C. BACKFILL CMU FIRE SEALANT @ ALL RATED ASSEMBLIES, TYP. FUTURE TENANT X-XX