Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
AA365 WALL SECTIONS AREA A H-J
Project: Developer: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: By: Sheet Title: CARMEL CITY CENTER Carmel, Indiana Building A Phase 1 COPYRIGHT & OWNERSHIP OF DOCUMENTS Architecture / Project Management: Project Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue Date PEDCOR DESIGN GROUP LLC 0502.00 AA365 WALL SECTIONS AREA A H-J Bid Set 04.21.06 THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP,LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2006, 2007, 2008, 2009, JAMES R. STUTZMAN, AIA, CARMEL, INDIANA 30 31 32 33 34 35 36 BID SET A.500, CCC.A.ASI.2, 5/15/09 PLUMBING FIXTURE DIMENSION UPDATE A.ASI.003, 05/29/09 STOREFRONT AND WALL BASE UPDATES 6/29/09 A.ASI.004, 06/10/09 SHEET METAL FLASHING & METAL ROOF COLOR UPDATE, 08/17/09 BID SET A.500, CCC.A.ASI.9, 8/25/09 LOFT LEVEL PLAN UPDATE OWNER REVISION UPDATE, 08/31/09 SCALE: NTS PLAN NORTH 28 22 16 H M AREA A AREA C AREA B R KEY PLAN BLDG A 36 H 9'-5 1/2" 24'-0" 13'-9" TYPICAL HEAD OF WALL ASSEMBLY W/ DEEP LEG TRACK OR STUD ATTACHEMNT CLIP SEE S- SERIES DRAWINGS SEE SHEET AA504 / AA505 FOR FIREPROOFING AND CFS FRAMING CFS FRAMING TO SUPPORT FLAT ROOF ABOVE, BEARING = 10'-9 1/2" ABOVE STRUCTURAL SLAB TO BOTTOM OF CFS HEADER ALUMINUM DOOR 6" CFS STUDS @ 16" O.C. SEE DETAIL 4/AA704 FOR FIRE RATED ROOF ASSEMBLY METAL SHINGLE ROOFING 1 1/2" METAL DECK REF. S- SERIES DRAWINGS ORNAMENTAL EIFS RELIEF BEYOND CFS TRUSS REFRENCE S-SERIES DRAWINGS 1 1/2" METAL DECK REF. S- SERIES DRAWINGS SLOPE ROOF INSULATION AS NEEDED TO DRAIN HORIZONTAL EXPANSION JOINT METAL WALL PANEL 6" CFS BLOCKING AS REQUIRED +56'-0" 5 Fifth Floor +69'-9" 6 Sixth Floor 5 AA566 2 AA566 18'-0" 12'-0" 1'-4" 1'-0" 1'-6 1/4" +16'-0" +14'-0" METAL RAILING SEE 4/AA705 AND S-SERIES DWGS FOR ATTACHMENT REQUIREMENTS WEATHER BARRIER EIFS VENEER VAPOR BARRIER FABRIC AWNING, BY TENANT 8" CFS STUD WALL W/ EXTERIOR SHEATHING STL. BEAM, REF. TO S- SERIES DWGS SPRAY APPLIED FIRE RESISTIVE MATERIAL (N.I.C) CONCRETE SLAB EPS FOAM PAVING EIFS VENEER WEATHER BARRIER DEEP LEG TRACK DIRECT APPLIED FINISH SYSTEM, OVER 5/8" EXTERIOR SHEATHING EXISTING C.I.P. CONC STRUCTURE, REF. TO S- SERIES DWGS BRICK VENEER COLUMN ENCLOSURE BEYOND STONE BASE BEYOND EIFS VENEER 4" SOLID OR GROUTED SOLID CMU BELOW GRADE 8" CMU, GROUTED SOLID, REF S-SERIES DWGS ALUMN. STOREFRONT CFS BRACING AS REQUIRED PAVING, N.I.C. GALVANIZED STEEL ANGLE BRICK VENEER ALONG RAMP GRANITE BORDER/ RAMPWALL CAP GUARD RAILING CEILING HEIGHT SOFFIT HEIGHT CFS SOFFIT FRAMING, HANG FROM FLOOR ABOVE CFS CLIPS, TYPICAL CFS KICKERS @ EA STUD 8" CFS STUD WALL, HANG FROM FLOOR ABOVE BOT OF HEADER STEEL PLATE, FOR FUTURE AWNING SUPPORT ATTACHMENT, REF S-SERIES DWGS GRANITE BASE, REF 15/ AA545 FOR PROFILE +2'-0" 1 First Floor +20'-0" 2 Second Floor +32'-0" 3 Third Floor HORIZONTAL EXPANSION JOINT EIFS FLOOR BAND SEE DETAIL 8/AA566 TYPICAL INSULATED CFS HEADER, REF. S-SERIES DRAWINGS H 6 AA566 24'-0" 13'-9" TYPICAL HEAD OF WALL ASSEMBLY W/ DEEP LEG TRACK OR STUD ATTACHEMNT CLIP SEE S- SERIES DRAWINGS SEE SHEET AA504 / AA505 FOR FIREPROOFING AND CFS FRAMING INSULATED CFS HEADER BEAM REF. S-SERIES DRAWINGS (TYPIAL) 6" CFS STUDS @ 16" O.C. CFS TRUSS REFRENCE S-SERIES DRAWINGS TYPICAL HEAD OF WALL ASSEMBLY W/ DEEP LEG TRACK OR STUD ATTACHEMNT CLIP SEE S- SERIES DRAWINGS SEE DETAIL 4/AA704 FOR FIRE RATED ROOF ASSEMBLY METAL SHINGLE ROOFING 1 1/2" METAL DECK REF. S- SERIES DRAWINGS EIFS BRACKET EIFS VENEER EIFS CORNICE PREFINISHED METAL TRIM CFS FRAMINIG AS REQUIRED PREFINISHED METAL DOWNSPOUT BEYOND PREFINISHED METAL GUTTER ORNAMENTAL EIFS RELIEF BEYOND COMPOSITE DECK REF. S-SERIES DRAWINGS PREFINISHED METAL CAP OVER 3/4" FIRE TREATED PLYWOOD, REF. 19/AA701 HORIZONTAL EXPANSION JOINT +56'-0" 5 Fifth Floor +69'-9" 6 Sixth Floor 7 AA566 7'-3" 7'-3" 1'-4" 7" 18'-0" 12'-0" 1'-8" 1'-0" 1'-6 1/4" +16'-0" METAL RAILING SEE 4/AA705 AND S-SERIES DWGS FOR ATTACHMENT REQUIREMENTS TO BOTTOM OF CFS HEADER TO BOTTOM OF CFS HEADER SEE SHEET AA504 / AA505 FOR FIREPROOFING AND CFS FRAMING METAL RAILING WEATHER BARRIER EIFS VENEER VAPOR BARRIER FABRIC AWNING, BY TENANT 8" CFS STUD WALL W/ EXTERIOR SHEATHING STL. BEAM, REF. TO S- SERIES DWGS SPRAY APPLIED FIRE RESISTIVE MATERIAL (N.I.C) CONCRETE SLAB EPS FOAM PAVING EIFS VENEER WEATHER BARRIER DEEP LEG TRACK DIRECT APPLIED FINISH SYSTEM, OVER 5/8" EXTERIOR SHEATHING EXISTING C.I.P. CONC STRUCTURE, REF. TO S- SERIES DWGS BRICK VENEER COLUMN ENCLOSURE BEYOND STONE BASE BEYOND EIFS VENEER 4" SOLID OR GROUTED SOLID CMU BELOW GRADE 8" CMU, GROUTED SOLID, REF S-SERIES DWGS CFS SOFFIT FRAMING CFS BRACING AS REQUIRED HORIZONTAL EXPANSION JOINT GUARD RAILING PAVING, N.I.C. GALVANIZED STEEL ANGLE BRICK VENEER ALONG RAMP GRANITE BORDER/ RAMPWALL CAP CEILING HEIGHT SOFFIT HEIGHT CFS SOFFIT FRAMING, HANG FROM FLOOR ABOVE CFS CLIPS, TYPICAL CFS KICKERS @ EA STUD CFS SOFFIT FRAMING STEEL PLATE, FOR FUTURE AWNING SUPPORT ATTACHMENT, REF S-SERIES DWGS +2'-0" 1 First Floor +20'-0" 2 Second Floor +32'-0" 3 Third Floor +14'-0" EIFS FLOOR BAND SEE DETAIL 8/AA566 TYPICAL J 2 AA704 13'-9" 10'-6" TYPICAL HEAD OF WALL ASSEMBLY W/ DEEP LEG TRACK OR STUD ATTACHEMNT CLIP SEE S- SERIES DRAWINGS SEE SHEET AA504 / AA505 FOR FIREPROOFING AND CFS FRAMING PREFINISHED METAL FASCIA EIFS VENEER VAPOR BARRIER 5/8" EXTERIOR SHEATHING 6" CFS STUDS @ 16" O.C. COMPOSITE DECK REF. S-SERIES DRAWINGS WEATHER BARRIER BATT INSULATION BATT INSULATION MEMBRANE ROOFING CFS TRUSS REFRENCE S-SERIES DRAWINGS SEE DETAIL 4/AA704 FOR FIRE RATED ROOF ASSEMBLY METAL SHINGLE ROOFING 1 1/2" METAL DECK REF. S- SERIES DRAWINGS TRUSS BEARING SIM. CFS SOFFIT FRAMING AS REQUIRED PREFINISHED METAL SOFFIT HORIZONTAL EXPANSION JOINT +56'-0" 5 Fifth Floor +69'-9" 6 Sixth Floor +16'-0" +14'-0" 1" 3 1/2" FABRIC AWNING, BY TENANT 8" CFS STUD WALL W/ EXTERIOR SHEATHING STL. BEAM, REF. TO S- SERIES DWGS SPRAY APPLIED FIRE RESISTIVE MATERIAL (N.I.C) CONCRETE SLAB EPS FOAM PAVING EIFS VENEER WEATHER BARRIER EXISTING C.I.P. CONC STRUCTURE, REF. TO S- SERIES DWGS BRICK VENEER GRANITE SILL EIFS VENEER 4" SOLID OR GROUTED SOLID CMU BELOW GRADE 8" CMU, GROUTED SOLID, REF S-SERIES DWGS ALUMN. STOREFRONT PAVING, N.I.C. GALVANIZED STEEL ANGLE, REF S-SERIES DWGS CEILING HEIGHT YORK THRU-WALL FLASHING ABOVE GRADE YORK THRU-WALL FLASHING 4" SOLID CMU GRANITE PANEL STEEL TUBE FOR STUB OUT TO STEEL PLATE, FOR FUTURE AWNING CONNECTION, REF S- SERIES DWGS GRANITE BASE, REF 15/ AA545 FOR PROFILE 6" SOLID OR GROUTED SOLID CMU BELOW GRADE 8" CMU, GROUTED SOLID, REF S-SERIES DWGS H 4" 4" VARIES, SEE ELEVATION 1" 1 1/4" 1 1/2" 4'-8 3/4" INSULATED CFS HEADER, REF. S-SERIES DRAWINGS CFS KICKERS @ EA STUD BOT OF HEADER SCALE: 3/8" = 1'-0" 1 WALL SECTION AA365 0 2' 4' 6' SCALE: 3/8" = 1'-0" 2 WALL SECTION AA365 0 2' 4' 6' SCALE: 3/8" = 1'-0" 3 WALL SECTION AA365 0 2' 4' 6' SCALE: 3/8" = 1'-0" 4 WALL SECTION AA365 0 2' 4' 6' 12.12.08 JPM, JDR BAB, JAW A305A, A.310A 08.31.09