Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
IA154A UNIT 604 ENLARGED PLAN
29 CCC.A.ASI.1, 5.20.09 RFI UPDATES, PUBLIC WAYS, ROOF UPDATES 30 BID SET A.500, CCC.A.ASI.2, 5/15/09 PLUMBING FIXTURE DIMENSION UPDATE Project: Project Number: Revisions: Issue Date Drawn By Checked By Developer: Architecture / Project Managment: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: By: Sheet Title: CARMEL CITY CENTER Carmel, Indiana Building A Phase 1 COPYRIGHT & OWNERSHIP OF DOCUMENTS SCALE: NTS PLAN NORTH 28 22 16 H M R KEY PLAN BLDG A PEDCOR DESIGN GROUP 0502.00 IA154A UNIT 604 ENLARGED PLAN BID SET A500 AR MC REVIEW SET: 12/04/07 BID SET: 01/22/09 THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP,LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP,LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP,LLC. © COPYRIGHT 2006, 2007, 2008 JAMES R. STUTZMAN, AIA, CARMEL, INDIANA 01/22/2009 29 9 1 S3.5Fi S3.5G 2 S3.5Bi S3.5G S3.5Bi 1 S3.5Bi 7 S3.5Bi 7 S3.5G S3.5Fi S6Fi 8 S3.5Fi 1 9 S3.5Fi S3.5Bi 8 S3.5Bi S3.5Fi 1 9 1 S3.5Fi S3.5G S3.5G S3.5E 1 1 S3.5Fi 2 1 S3.5Bi S3.5Bi S3.5F S3.5G S3.5G 1 S3.5G S3.5Bi S3.5E S3.5E 7 S3.5Bi S3.5E S2.5A S2.5A S2.5A S2.5A S2.5A S2.5A S2.5A S2.5A S2.5Ki S2.5Ki S2.5Mi S2.5Mi S2.5Ki S2.5Ki S2.5Ki S2.5A S2.5E S3.5Bi S3.5Bi 1 S3.5G S2.5E 8 S3.5G F F 2'-2 5/8" 3'-1 3/4" 2'-1 1/4" 6'-8 1/4" 5'-7 3/8" 15'-3/4" 13'-1 3/16" 3 5/8" 4'-1 5/16" 5'-11 3/8" 7'-8 7/8" 6'-4 3/8" 10'-10 3/8" 7'-9 7/8" 8'-7 9/16" 4'-1 1/4" 11'-11 5/16" 10'-11" 3 5/8" 7'-6 3/8" 6'-1 7/8" 3 5/8" 5'-11 1/16" 4'-1 1/4" 12'-8 1/8" 5'-6 11/16" 3 5/8" 6'-1" 2'-2 5/8" 3 5/8" 9'-5 1/16" 6'-3 7/8" 6'-3 3/4" 2'-11 5/8" 3 5/8" 6'-5 1/2" 2'-1 1/4" 12'-1 1/4" 4'-7 1/2" 8'-10 11/16" 7'-6 3/8" 8'-8 1/4" 3'-4 7/8" 4'-4 7/8" 8'-1 3/8" 1'-4" 9'-9 7/8" 3 5/8" 4'-1 1/4" 8'-2 7/8" 11'-6 1/16" 5'-1/8" 4'-5" 9'-10 7/8" 2'-4 11/16" 6 5/8" 13'-3 3/4" 13'-7" 2'-2 1/2" 11'-11 3/4" 2'-10 3/8" 7'-7 1/8" 2'-1 5/8" 4'-5 7/16" 2'-3/4" 2'-5/8" 3' 2'-4 3/8" 5' 4'-6 7/8" 5'-1 7/8" 5' 5 3/4" R 5'-1 1/4" R 4' FP2 FP12 FP4 FP2 FP5 FP4 FP12 FP5 FP6 FP1 FP11 FP5 FP4 FP12 FP11 FP5 FP6 FP25 FP22 FP2 FP6 FP4 FP5 FP5 FP2 FP1 FP1 CL 4 BEDROOM 7 LAUNDRY 9 PANTRY 15 KITCHEN 16 MASTER BATHROOM 5 DINING ROOM 17 MASTER BEDROOM 6 CL 8 MECH 3 HALL 2 SITTING AREA 14 POWDER ROOM 19 CL 22 CL 2 LAUNDRY 4 MECH 5 HALLWAY 6 PANTRY 7 BATHROOM 10 ENTRY 1 CL 25 MECH 24 LAUNDRY 21 HALLWAY 23 LINEN 11 ENTRY 1 LIVING ROOM 22 HALL 12 PENTHOUSE 04 ENTRY 21 MASTER BATHROOM 18 IT/ELEC MECH GENERAL CONSTRUCTION NOTES: 1. 2. SEE IA800 FOR WALL CONSTRUCTION AND WALL TYPES. ALL WALL CONSTRUCTION TO BE S3.5B, UNLESS NOTED OTHERWISE. ALL WALL CONSTRUCTION AT COLUMNS AND CORRIDOR PILASTERS TO BE S3.5A UNLESS NOTED OTHERWISE. 3. 5. PROVIDE CONCEALED FIRE RATED WOOD BLOCKING SUPPORTS AS REQUIRED FOR ALL SURFACE MOUNTED ITEMS. 6. RADIUS ALL OUTSIDE CORNERS OF COUNTER TOPS. SIZE OF RADIUS TO BE VERIFIED WITH ARCHITECT. 4. IN KITCHENS, PROVIDE CLEARANCE AS REQUIRED BY FAIR HOUSING ACT, SPECIFICALLY 40" MIN. CLEARANCE BETWEEN ALL COUNTERS, BASE CABINETS, APPLIANCES AND WALLS, MEASURED FROM ANY COUNTERTOP OR FACE OF APPLIANCE. NEW DOOR AND FRAME SYMBOLS CORRESPOND TO DOOR/FRAME/HDWR TYPES AS LISTED ON THE DOOR/FRAME/HDWR LEGEND. SEE IA701 FOR DETAILS. 7. 8. 9. ALL NEW FIRE EXTINGUISHER CABINETS TO BE FINISHED TO MATCH ADJACENT WALL FINISH AND INSTALLED ACCORDING TO CODE. LIFESAFETY CONTRACTOR TO VERIFY PLACEMENT AND COUNT OF FIRE EXTINGUISHERS THROUGHOUT THE SPACE. IF ADDITIONAL FIRE EXTINGUISHER LOCATIONS ARE NEEDED, A PLAN MUST BE SUBMITTED TO THE DESIGNER FOR REVIEW OF AESTHETIC PURPOSES ONLY. APPLY SEALANT AT ALL PLUMBING FIXTURES, AT JUNCTURE WITH WALL, AND AT ALL COUNTERTOPS AND BACKSPLASH JUNCTURES. 10. 11. 12. G.C. TO PROVIDE BLINDS AT ALL PERIMETER WINDOWS. ALL NEW DOORS TO BE INSTALLED WITH HINGE 4" MINIMUM AWAY FROM WALL. 15. FLOOR SHALL BE CLEANED, SMOOTH AND LEVEL FOR INSTALLATION OF TOP LAYER OF SOUND ISOLATION SYSTEM AND NEW FLOOR FINISHES AS SCHEDULED. SEE 3/IA426 FOR DETAILS. 13. 14. ALL WALLS INDENTIFIED ON THE ARCHITECTURAL SHELL PACKAGE (I.E. CORE WALLS, AND DEMISING WALLS) SHALL BE PATCHED, REPAIRED, AND SANDED SMOOTH IN PREPARATION FOR NEW FINISHES. 16. GREENBOARD TO BE USED WITHIN ALL BATHROOMS. 17. ALL WALLS SHALL BE CHALKED OFF FOR ARCHITECT'S REVIEW OF NEW WALL CONSTRUCTION. IN BATHROOMS, PROVIDE CLEARANCE AS REQUIRED BY FAIR HOUSING ACT, SPECIFICALLY AT TOILETS THERE MUST BE AT LEAST 33" MIN. FROM THE SIDE WALL TO ANY SINK OR WING WALL. WING WALL MUST NOT PROJECT INTO ROOM MORE THAN 24". COORDINATE CLEARANCE AND ACCESS FOR MECHANICAL UNITS WITH MECHANICAL PLANS. CONTACT ARCHITECT TO COORDINATE ISSUES. CEMENT BOARD TO BE USED IN ALL SECTIONS AND PORTIONS OF WALLS AND CEILINGS W/ TILE FINISH. SEE FINISH PLANS AND REFERENCE CEILING PLANS TO COORDINATE FINISH LOCATION. DIMENSIONS ARE FROM FACE OF STUD TO FACE OF STUD UNLESS NOTED OR SHOWN OTHERWISE. TUBS AND SHOWERS AT WALLS W/(2) LAYERS OF DRYWALL ARE MEASURED TO THE 1ST LAYER OF DRYWALL. ANY DIMENSION NOT SHOWN OR DEEMED QUESTIONABLE ARE TO BE VERIFIED BY ARCHITECT. DO NOT SCALE DRAWINGS. 18. PROVIDE BLOCKING IN ALL BATH ROOMS AS REQUIRED FOR FUTURE GRAB BARS. SEE DETAIL 9/IA426 FOR LOCATIONS. 19. WALL TAG "SXXX + XX AFF" IDENTIFIES HEIGHT OF NEW LOW WALL CONSTRUCTION ABOVE FINISHED FLOOR. PROVIDE METAL KNEE BRACES AT UNSUPPORTED ENDS OF WALL. 20. ALL BID SET A.400 BUILDING SHELL WALLS ON I SERIES SHEETS ARE DENOTED WITH SOLID FILL. 21. ALL INTERIOR WALLS TO EXTEND 4" PAST FINISHED CEILING UNLESS OTHERWISE NOTED. 22. ALL WINDOWS ARE TO HAVE A MINIMUM 4" OF CLEARANCE FROM ADJACENT WALL. 23. SEE ENLARGED UNIT PLANS FOR DIMENSIONS, WALL TYPES, AND CONSTRUCTION DETAILS. 24. SEE IA400 SERIES INTERIOR ELEVATIONS AND DETAIL SHEETS FOR TYPICAL KITCHEN PLANS. TYPICAL KITCHEN PLANS DENOTE CABINET UNIT SIZES AND ARRANGEMENTS. ADD FILLER STRIPS AS NEEDED TO FIT ACTUAL WALL TO WALL DIMENSIONS. 25. ALL DRYWALL WRAPPED OPENINGS ARE TO BE 3'-0" X 7'-0", CENTERED ON HALL WITH 3" MINIMUM EACH SIDE. ALIGN FINISHED FACES. CONSTRUCTION PLAN NOTES: FP1 FP2 FP3 FP4 NEW RECESSED FIRE EXTINGUISHER CABINET TO BE INSTALLED IN WALL AT THIS LOCATION WITH TOP OF CABINET AT 54" AFF. PAINT TO MATCH ADJACENT WALL SURFACE. FIRE EXTINGUISHER CABINET TO MATCH BUILDING STANDARD, UNLESS NOTED OTHERWISE. FP5 FP6 PROVIDE WALL TYPE S3.5A. REFER TO BID SET A.400, SHEETS AA521-AA525 FOR DRAIN DETAILS AT COLUMN. FP7 FP8 FP9 FP10 REFER TO ARCHITECTURAL PLANS. FP11 PROVIDE WALL TYPE S3.5A AND LOCATE NEW WALL FRAMING SO THAT STUDS ARE TIGHT TO THE STRUCTURAL COLUMNS. PROVIDE ROD AND SHELF. REFERENCE DETAIL 4/IA425. (5) 16" d.p. 3/4" MELAMINE SHELVES ON WALL CLEATS. PROVIDE ADDITIONAL BLOCKING AS REQUIRED. REFERENCE DETAIL 11/IA425. (1) 16"dp. 3/4" MELAMINE SHELF ON WALL CLEATS ABOVE LAUNDRY SINK. PROVIDE ADDITIONAL BLOCKING AS REQUIRED. REFERENCE ELEVATION 8/IA425. PROVIDE 18"dp X 1" GRANITE COUNTERTOP. INCLUDE WOOD BRACKETS AT X'-X" FROM EACH END. SEE DETAIL 4/IA426. REFER TO ENLARGED DETAILS FOR ELEVATOR LOBBY, IA430. PROVIDE (1) BOX SHELF AS SHOWN IN CLOSET WITH SINGLE ROD (REPRESENTED WITH SINGLE DASHED LINE) AND SHELF ON ONE SIDE AND DOUBLE ROD (REPRESENTED WITH DOUBLE DASHED LINE) AND SHELF ON THE OTHER, UNLESS SHOWN OTHERWISE. SEE ELEVATION 10/A425. REFER TO CONSTRUCTION PLAN FOR VARIATIONS. FP12 TYPICAL KITCHEN LAYOUT #2, AS SHOWN IN 2/IA416. RETURN 18" COUNTER TO WALL. FP13 PROVIDE (1) DOUBLE DOOR CABINET ABOVE LAUNDRY SINK. PROVIDE ADDITIONAL BLOCKING AS REQUIRED. SEE ELEVATION 12/IA425. FP14 TYPICAL BATHROOM LAYOUT #2, AS SHOWN IN 2/IA418, WITH 5' SHOWER IN PLACE OF TUB. CENTER 30" DOOR ON SHOWER OPENING. FP15 FP16 TYPICAL BATHROOM LAYOUT #17, AS SHOWN IN 2/IA423, WITH 5' SHOWER IN PLACE OF TUB. CENTER 30" DOOR ON SHOWER OPENING. TYPICAL BATHROOM LAYOUT #11, AS SHOWN IN 2/IA421, WITH VANITY LINEN TALL VL242184R ADDED AT CORNER. PROVIDE END PANEL FOR EXPOSED SIDE OF LINEN CABINET. FP17 TYPICAL BATHROOM LAYOUT #12, AS SHOWN IN 3/IA419, WITH 5' SHOWER IN PLACE OF TUB. CENTER 30" DOOR ON SHOWER OPENING. TYPICAL KITCHEN LAYOUT #5, AS SHOWN IN 1/IA417. EXTEND COUNTER FROM WALL TO WALL. FP18 FP19 TYPICAL KITCHEN LAYOUT #3, AS SHOWN IN 3/IA416. EXTEND COUNTER FROM WALL TO WALL. FP20 TYPICAL KITCHEN LAYOUT #4, AS SHOWN IN 4/IA416. EXTEND COUNTER FROM WALL TO WALL. FP21 TYPICAL BATHROOM LAYOUT #11, AS SHOWN IN 2/IA421, REFER TO ELEVATION FOR VANITY AND MIRROR SIZE. ALL DRYWALL WRAPPED OPENINGS ARE TO BE 3'-0" X 7'-0", CENTERED ON HALL WITH 3" MINIMUM EACH SIDE. NEW PORTABLE FIRE EXTINGUISHERS TO BE PROVIDED IN EACH UNIT. PLACE FIRE EXTINGUISHER IN CABINET UNDER SINK. FP22 FP23 TYPICAL BATHROOM LAYOUT #21, AS SHOWN IN 3/IA424, WITH VANITY LINEN TALL VL182184 ADDED AT CORNER. PROVIDE END PANEL FOR EXPOSED SIDE OF LINEN CABINET. FP24 TYPICAL BATHROOM LAYOUT #8, AS SHOWN IN 2/IA420, REFER TO ELEVATION FOR VANITY SIZE. FP25 VENTLESS GAS FIREPLACE. SCALE: 1/4" = 1'-0" 1 UNIT 604 CONSTRUCTION PLAN IA154A UNIT #604 N N.5 26 25 M.5 24 23.1 NOTE: FOR REFERENCE ONLY. REFER TO CUSTOM DRAWINGS FOR INTERIOR UNIT CONSTRUCTION PLANS.