Loading...
HomeMy WebLinkAboutIA800 GENERAL BUILDING SCHEDULE29 CCC.A.ASI.1, 5.20.09 RFI UPDATES, PUBLIC WAYS, ROOF UPDATES 30 BID SET A.500, CCC.A.ASI.2, 5/15/09 PLUMBING FIXTURE DIMENSION UPDATE Project Number: Revisions: Issue Date Drawn By Checked By Architecture / Project Managment: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: Sheet Title: Project: Developer: By: CARMEL CITY CENTER Carmel, Indiana Building A Phase 1 COPYRIGHT & OWNERSHIP OF DOCUMENTS SCALE: NTS PLAN NORTH 28 22 16 H M AREA A AREA C AREA B R KEY PLAN BLDG A PEDCOR DESIGN GROUP 0502.00 IA800 GENERAL BUILDING SCHEDULE Friday, May 22, 2009; alldata:MS:DESIGN:PROJECTS:CARMEL CITY CENTER:CCC Drawings:CCC Construction Doc:Building A:A.General:BLDG A INTERIORS:CDs:IBASE.pln BID SET A500 AR MC THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP,LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP,LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP,LLC. © COPYRIGHT 2006, 2007, 2008 JAMES R. STUTZMAN, AIA, CARMEL, INDIANA 01/22/2009 REVIEW SET: 12/04/07 BID SET: 01/22/09 SOAP DISPENSER TOILET TISSUE DISP. NO. ITEM GRAB BAR - 48" MIRROR W/ TEMPERED GLASS T1 T3 GRAB BAR - 36" T2 T4 T5 T6 REST ROOM ACCESSORY SCHEDULE BOBRICK BOBRICK BOBRICK BOBRICK BOBRICK CATALOG NUMBER B-6806 X 36 B-6806 X 48 MOUNTING HEIGHT MOUNT AT 39" A.F.F. TO BOTTOM. MOUNT AT 28" A.F.F. TO TOP. MOUNT AT 34" A.F.F. MOUNT AT 34" A.F.F. T6A MANUFACTURER (OR APPROVED EQUAL) MOUNT IN COUNTER. T6B PAPER TOWEL DISPENSER WASTE BIN B-43944 MOUNT AT 60-1/4" A.F.F. TO TOP. T8A BOBRICK B-4288 B-826.18 BOBRICK B-4362 SANITARY NAPKIN DISPOSAL 6" DIAMETER HOLE IN COUNTER. WASTE BIN/TOWEL DISPENSER T7 T8 MOUNT AT 52" A.F.F. TO TOP. BOBRICK BOBRICK MOUNT AT 31" A.F.F. TO TOP. SANITARY NAPKIN DISPENSER B-435009 B-4354 MOUNT AT 30" A.F.F. TO TOP. BOBRICK SANITARY NAPKIN DISPOSAL (WALL MOUNT) B-270 MOUNT AT 44" A.F.F. TO TOP. OVERHEAD BRACED PV8ACSL BI- LEVEL MODULAR STAINLESS STEEL T9 TOILET PARTITIONS BOBRICK T10 DRINKING FOUNTAIN OASIS T11 B-2908 36"W X 60"H MOUNT AT 12" A.F.F. TO BOTTOM. T12 FULL-LENGTH MIRROR BOBRICK DIAPER CHANGING STATION KOALA KARE KB100-SSWM 1082 DURALINE SERIES BOBRICK B-529 B-2260 B-2908 (42" X XXX) SEE ELEV. M/W: MOUNT AT 58-1/2" A.F.F. TO TOP. AS RECOMMENDED BY MANUFACTURER. T5A SOAP DISPENSER BOBRICK MOUNT AT 48" A.F.F. TO TOP. B-2111 AS RECOMMENDED BY PARTITION MANUFACTURER. T9A HANDLES-TOILET PARTITIONS MOCKETT DP124A-MATTE CHROME S3.5A S3.5Bi S6Bi S6Di S6B S6C S6Ci S3.5B S3.5E S3.5F S3.5Fi S3.5G S3.5Gi S6E S6F S6Fi S6G S1.5A S2.5A S2.5H S4H S2.5E S2.5Ji S2.5Ki S2.5Li S2.5Mi S6A 6" Metal stud wall, min. 16" o.c.; 5/8" gypsum board, 2 layers on both sides. 6" Metal stud wall, min. 16" o.c.; 5/8" gypsum board, 2 layers on both sides, with batt insulation (see specification for requirements) 3-5/8" Metal stud wall, min. 16" o.c.; 5/8" gypsum board on both sides. 3-5/8" Metal stud wall, min. 16" o.c.; 5/8" Moisture and Mold Resistant board, on one side. 3-5/8" Metal stud wall, min. 16" o.c.; 5/8" Moisture and Mold Resistant board, on one side, 5/8" gypsum, on one side. 3-5/8" Metal stud wall, min. 16" o.c.; 5/8" Moisture and Mold Resistant board, on one side, 5/8" gypsum, on one side, with batt insulation (see specifications for requirements). 3-5/8" Metal stud wall, min. 16" o.c.; 5/8" Moisture and Mold Resistant board on both sides. 3-5/8" Metal stud wall, min. 16" o.c.; 5/8" Moisture and Mold Resistant board on both sides, with batt insulation (see specifications for requirements). 6" Metal stud wall, min. 16" o.c.; 5/8" Moisture and Mold Resistant board, on one side. 6" Metal stud wall, min. 16" o.c.; 5/8" Moisture and Mold Resistant board, on one side, 5/8" gypsum, on one side. 6" Metal stud wall, min. 16" o.c.; 5/8" Moisture and Mold Resistant board, on one side, 5/8" gypsum, on one side, with batt insulation (see specifications for requirements). 6" Metal stud wall, min. 16" o.c.; 5/8" Moisture and Mold Resistant board on both sides. 3-5/8" Metal stud wall, min. 16" o.c.; 5/8" gypsum board on one side. 3-5/8" Metal stud wall, min. 16" o.c.; 5/8" gypsum board on both sides, with batt insulation (see specifications for requirements). 6" Metal stud wall, min. 16" o.c.; 5/8" gypsum board on both sides. 6" Metal stud wall, min. 16" o.c.; 5/8" gypsum board on both sides, with batt insulation (see specifications for requirements). 6" Metal stud wall, min. 16" o.c.; 5/8" gypsum board on one side; 5/8" exterior sheathing, with batt insulation (see specifications for requirements). 4 1/4" 4 7/8" 4 7/8" 4 1/4" 4 7/8" 4 7/8" 4 7/8" 4 7/8" 7 1/4" 7 1/4" 8 1/2" 8 1/2" 7 1/4" 6 5/8" 7 1/4" 7 1/4" 7 1/4" 1-5/8" Metal stud wall, min. 16" o.c.; 5/8" gypsum board on one side. 2 1/4" 2-1/2" Metal stud wall, min. 16" o.c.; 5/8" gypsum board on one side; 1" space on one side. 4 1/8" 2-1/2" CH studs, min. 24" o.c.; (2) layers of 1/2" gypsum board on one side; 1" liner panel on one side. Designation with " i " requires 1" sound batt insulation added in cavity. 3 1/2" 4" CH studs, min. 24" o.c.; (2) layers of 1/2" gypsum board on one side; 1" liner panel on one side. Designation with " i " requires 3" mineral fiber insulation added in cavity. 5" 6 5/8" 6" Metal stud wall, min. 16" o.c.; 5/8" gypsum board on one side. 2-1/2" Metal stud wall, min. 16" o.c.;(2) layers of 5/8" gypsum board on one side w/ batt insulation. 2-1/2" Metal stud wall, min. 16" o.c.; 5/8" Moisture and Mold Resistant board on one side; 1" space on one side. 4 1/8" 3 3/4" 2-1/2" Metal stud wall, min. 16" o.c.;(2) layers of 5/8" gypsum board on one side w/ additional 1-1/2" batt insulation (see specifications for requirements). 5 1/4" 2-1/2" Metal stud wall, min. 16" o.c.; 5/8" gypsum board; 5/8" Moisture and Mold Resistant board on one side w/ batt insulation. 3 3/4" 2-1/2" Metal stud wall, min. 16" o.c.; 5/8" gypsum board; 5/8" Moisture and Mold Resistant board on one side w/ additional 1-1/2" batt insulation (see specifications for requirements). 5 1/4" Thickness Wall Legend Plan View Section View Brief Description = Walls to extend to deck above.