HomeMy WebLinkAboutA6-2 - Details.pdf First Floor Slab 100' -0" 114' -4 1/2" TOP OF STEEL TAPERED INSULATION TPO ROOFING MEMBRANE ROOF HATCH -SEE SPECIFICATIONS 109' -0" BOTTOM OF BULKHEAD RECOVERY BOARD LAY-IN CEILING ALUMINUM ACCESS LADDER -SEE SPECIFICATIONS CONTINUOUS BACKER ROD AND SEALANT, SHIM AS BY WINDOW SYSTEM MFG's PRINTED RECOMMENDATIONS BENT PLATE, SEE STRUCTURAL CONT. 2x BLOCKING, CUT TO FIT. COUNTER SINK ANCHOR SPANDREL PANEL RECOVERY BOARD TPO ROOFING MEMBRANE, EXTEND DOWN BEHIND GRAVEL STOP FASCIA TAPPERED INSULATION 1" 4 1/2" FULLY ADHERED ROOF MEMBRANE FLASHING, INSTALL AS PER MFG.'S PRINTED RECOMMENDATIONS KYNAR COATED ALUMINUM GRAVEL STOP w/DRIP EDGE, MATCH FASCIA CONT. CLEAT w/CONT. BUTYL SEALANT TAPE 110' -2" DECK BEARING ATTACH LAY-IN CEILING PERIMETER TRIM TO WINDOW MULLION CONTINUOUS BACKER ROD AND SEALANT, BOTH FACES OF FRAME BENT PLATE, SEE STRUCTURAL 5/8" GYPSUM BOARD -PAINT 5/8" GYPSUM BD. -PAINTED, OVER 3/4" PLYWOOD SPANDREL PANEL 110' -2" DECK BEARING CONT. 2x BLOCKING, CUT TO FIT. COUNTER SINK ANCHOR CONT. L-TRIM 3 5/8" METAL STUDS @16" O.C. METAL DECK 2 5 1/2" 4 1/2" KYNAR COATED .063 FORMED 4 1/2" ALUM. SNAP-ON TRIM, MATCH FASCIA w/CONCEALED 20 GA. GALVANIZED STEEL RETAINER TREATED 1x BLOCKING, ANCHOR TO DECK RECOVERY BOARD TPO ROOFING MEMBRANE 3" STRUCTURAL STEEL DECK 8" FULLY ADHERED ROOF MEMBRANE FLASHING, INSTALL AS PER MFG.'S PRINTED RECOMMENDATIONS CONTINUOUS CLEAT, ANCHOR TO DECK STEEL BEAM, PAINT. SEE STRUCTURAL DRAWINGS 1" 5" 1" 1 1/2" TREATED BLOCKING RECOVERY BOARD TPO ROOFING MEMBRANE 3" STRUCTURAL STEEL DECK FULLY ADHERED ROOF MEMBRANE FLASHING, INSTALL AS PER MFG.'S PRINTED RECOMMENDATIONS STEEL BEAM, PAINT. SEE STRUCTURAL DRAWINGS .040 MIN ALUMINUM GUTTER 3/4" EXTERIOR GRADE PLYWOOD 3/4" EXTERIOR GRADE PLYWOOD. ANCHOR THROUGH INSULATION TO INNER PLYWOOD 2" RIGID INSULATION RECOVERY BOARD TAPERED INSULATION 5/8" GYPSUM BOARD STEEL PLATE, SEE STRUCTURAL 2x TREATED BLOCKING CONTROL JOINT MEMBRANE FLASHING TO EXTEND ACROSS TOP OF PARAPET (2) PIECE METAL COUNTER & THRU-WALL FLASHING CONTINUOUS BACKER ROD AND SEALANT, TYP. BOTH SIDES 6 THICK BATT INSULATION w/PSK-25 FACE -FULLY TAPE ALL EDGES AND SEAMS 6" METAL STUD FRAMING @8" O.C. 3 5/8" METAL STUD FRAMING @8" O.C. THE FACE OF THIS WALL IS TO BE CURVED, NOT SEGMENTED. PLYWOOD MAY BE BUILT UP TO 3/4" USING LAYERS OF THINNER SHEETS AS REQUIRED. CUT/TRIM RIGID INSULATION AS REQUIRED TO MAINTAIN 2" THICKNESS AND CURVED FACE I Y 1' -8" 1 3/8" 1 3/8" 5/8" DENS GLAS 3 5/8" METAL STUD FRAMING @16" O.C. 3' -4" TYVEC COMMERCIAL WRAP K 2" 6" 8" 7" TPO ROOFING MEMBRANE 3/4" EXTERIOR GRADE PLYWOOD FULLY ADHERED MEMBRANE FLASHING TO EXTEND ACROSS TOP OF PARAPET RECOVERY BOARD BENT STEEL SUPPORT 3 5/8" METAL STUD FRAMING TREATED 2x BLOCKING CONT. CLEAT CONTINUOUS SEALANT 2-PIECE COUNTERFLASHING BEYOND FORMED ALUMINUM, MATCH FASCIA J-CLIP, MATCH FASCIA PERFORATED ALUMINUM SOFFIT, MATCH FASCIA KYNAR COATED ALUMINUM COPING, COLOR BY ARCHITECT. PROVIDE CONCEALED COVER PLATE. SEAL w/BUTYL SEALANT TAPE GALVANIZED ANCHOR PLATE ASSEMBLY w/CONTINUOUS FACE CLEATS, ANCHOR TO PLYWOOD 109' -10" BOTTOM OF DENS GLAS E.I.F.S. SYSTEM APPLIED TO 2" RIGID INSULATION E.I.F.S. SYSTEM APPLIED TO 5/8" DENS GLAS CONTROL JOINT 5/8" DENS GLAS 4'-10" TOP OF TUBE HSS 3x3x1/4 WELDED TO BASE PLATE 12"x12"x1/4" BASE PLATE EMBEDDED FLUSH IN CONCRETE SLAB (4) 1/2"x3" STUDS -ONE @EACH CORNER, WELDED TO PLATE EMBED PLATE ONLY -INSTALL TUBE WHEN FRAMING WALLS NOTE: THIS DETAIL OCCURS AT THE END OF LOW WALLS AND AT GATE JAMBS IN LOW WALLS. SHIM AS REQUIRED 5/8" GYPSUM BOARD 6" METAL STUD FRAMING @16" O.C. 2" RIGID INSULATION 5/8" DENS GLAS CONTINUOUS BACKER ROD AND SEALANT, TYP. BOTH SIDES TYVEK COMMERCIAL WRAP MODULAR FACE BRICK 6 THICK BATT INSULATION w/PSK-25 FACE -FULLY TAPE ALL EDGES AND SEAMS SELF ADHERING MEMBRANE -LAP OVER TYVEK COMMERCIAL WRAP AND BEHIND GYP. BD. ON INTERIOR REFER TO P-TYPE FOR WALL CONSTRUCTION THRU-WALL FLASHING END DAM @SILL SHIM AS REQUIRED CONTINUOUS BACKER ROD AND SEALANT, TYP. BOTH SIDES SELF ADHERING MEMBRANE -LAP OVER TYVEK COMMERCIAL WRAP AND 3/4" EXTERIOR GRADE PLYWOOD. RUN BEHIND GYP. BD. ON INTERIOR REFER TO P-TYPE FOR WALL CONSTRUCTION ALUMINUM TRIM CONTINUOUS BACKER ROD AND SEALANT, TYP. BOTH SIDES 2 7/8" ALIGN w/FACE OF WALL ABOVE. SEE 3/A6.3 5 1/2" 3/4" OAK BASEBOARD w/OGEE -STAINED 1" 5 1/4" 1/4" 1x6 OAK CASING w/OGEE -STAINED 1"x1 1/4" OAK BACKBAND -STAINED 5/4" OAK FRAME w/1x2 DOOR STOP -STAINED REFER TO P-TYPE FOR WALL CONSTRUCTION TYPICAL AT HEAD AND JAMB OF THIS OPENING First Floor Slab 100' -0" CONTINUOUS BACKER ROD AND SEALANT, TYP. BOTH SIDES. SHIM AS REQUIRED. HIGH PERFORMANCE VAPOR BARRIER FLOORING, REFER TO FINISH SCHEDULE TREATED 2x2 FRAMING EXTERIOR GRADE 3/4" PLYWOOD WHITE ALUMINUM, BREAK METAL COVER FIN-TUBE CONTINUOUS SEALANT AT HALLWAY 102, WAITING 110, BREAKROOM 133 AND BANKING LOBBY 139. PROVIDE ONE CONTINUOUS ALUMINUM COVER FROM END WALL TO END WALL. AT LOBBY 101, SEGMENT THE COVER TO MATCH WINDOW SYSTEM. SEE A11.1 FOR EXTENTS OF CHASE ALUMINUM WINDOW SYSTEM ELETRICAL CHASE SUPPLIED FROM UNDER SLAB 2 1/4" 6" JAMES R. KRATZ AT ARCHI TECTREGISTERED 19500182 STATE OF I I ND A AN No. COMMISSION NUMBER DATE SHEET NUMBER SHEET TITLE The concepts, ideas, designs, plans, and details as shown on this document are the sole property of MSKTD & Associates, Inc., and were created, developed and presented for use on this specific project. None of the concepts, ideas, designs, plans, and details shall be used by any person, firm, or corporation for any purpose whatsoever, without the expressed written consent of MSKTD & Associates, Inc. The Owner shall be permitted to retain copies for information and reference in connection with this project. 1715 MAGNAVOX WAY FORT WAYNE, IN 46804 voice 260.432.9337 fax 260.436.2402 930 NORTH MERIDIAN INDIANAPOLIS, IN 46204 voice 317.917.1190 fax 317.822.6236 http://www.msktd.com ARCHITECTURE ENGINEERING INTERIOR DESIGN CERTIFICATION MSKTD 5629 BUILD 65076 CONSTRUCTION SET 3-21-11 3/18/2011 11:48:53 AM 100 W 96th St Indianapolis, Indiana 46290 A6.22-11-11 Indianapolis North DetailsLake City Bank 3/4" = 1'-0" 1 Roof Ladder & Hatch 1 1/2" = 1'-0" 2 Detail 1 1/2" = 1'-0" 3 Detail 1 1/2" = 1'-0" 4 Detail 1 1/2" = 1'-0" 5 Detail 1 1/2" = 1'-0" 9 Detail 1 1/2" = 1'-0" 10 Detail 1 1/2" = 1'-0" 6 Detail 1 1/2" = 1'-0" 11 Detail 1 1/2" = 1'-0" 7 Detail 1 1/2" = 1'-0" 8 Detail 3" = 1'-0" 12 Detail 3" = 1'-0" 13 Detail 1 1/2" = 1'-0" 14 Detail Revisions: Date: By: