HomeMy WebLinkAboutA6-3 - Details.pdf
F A6.1 5 3' -0" 3' -0" TAPERED RIGID INSULATION -SEE ROOF PLAN TPO ROOFING MEMBRANE, EXTEND UP BEHIND FLASHING FULLY ADHERED MEMBRANE FLASHING (2) PIECE METAL COUNTER & THRU-WALL FLASHING
1/2" RECOVERY BOARD FULLY ADHERED TPO ROOFING MEMBRANE, EXTEND UP BEHIND COUNTERFLASHING 3/4" EXTERIOR GRADE PLYWOOD 20 GA. 6" METAL STUDS @16" O.C. CLOSED CELL SPRAY FOAM INSULATION
AROUND STUDS LIGHT-WEIGHT AGGREGATE AND HIGH AIR CONTENT CMU TAPERED RIGID INSULATION -SEE ROOF PLAN RECOVERY BOARD X 9 SHIM AS REQUIRED CONTINUOUS BACKER ROD AND SEALANT, TYP. BOTH
SIDES SELF ADHERING MEMBRANE -LAP OVER TYVEK COMMERCIAL WRAP AND 3/4" EXTERIOR GRADE PLYWOOD. RUN BEHIND GYP. BD. ON INTERIOR REFER TO P-TYPE FOR WALL CONSTRUCTION ALUMINUM TRIM CONTINUOUS
BACKER ROD AND SEALANT, TYP. BOTH SIDES 3/4" EXTERIOR GRADE PLYWOOD 3/4" EXTERIOR GRADE PLYWOOD. ANCHOR THROUGH INSULATION TO INNER PLYWOOD 2" RIGID INSULATION MEMBRANE FLASHING TO EXTEND
ACROSS TOP OF PARAPET 6 THICK BATT INSULATION w/PSK-25 FACE -FULLY TAPE ALL EDGES AND SEAMS 6" METAL STUD FRAMING @8" O.C. 3/4" EXTERIOR GRADE PLYWOOD 6 THICK BATT INSULATION w/PSK-25
FACE -FULLY TAPE ALL EDGES AND SEAMS 6" METAL STUD FRAMING @8" O.C. 5/8" GYPSUM BOARD 3/4" EXTERIOR GRADE PLYWOOD 3 TAPERED RIGID INSULATION -SEE ROOF PLAN TPO ROOFING MEMBRANE, EXTEND
UP BEHIND FLASHING FULLY ADHERED MEMBRANE FLASHING (2) PIECE METAL COUNTER & THRU-WALL FLASHING RECOVERY BOARD FULLY ADHERED TPO ROOFING MEMBRANE, EXTEND UP BEHIND FLASHING 3/4" EXTERIOR
GRADE PLYWOOD 20 GA. 6" METAL STUDS @16" O.C. CLOSED CELL SPRAY FOAM INSULATION AROUND STUDS LIGHT-WEIGHT AGGREGATE AND HIGH AIR CONTENT CMU TAPERED RIGID INSULATION -SEE ROOF PLAN RECOVERY
BOARD 3' -0" 3' -0" A6.1 5 TUBE -SEE STRUCTURAL DRAWINGS 4" 10" SHIM AS REQUIRED CONTINUOUS BACKER ROD AND SEALANT, TYP. BOTH SIDES SELF ADHERING MEMBRANE -LAP OVER TYVEK COMMERCIAL
WRAP AND 3/4" EXTERIOR GRADE PLYWOOD. RUN BEHIND GYP. BD. ON INTERIOR ALUMINUM TRIM, EXTEND UP UNDER FLASHING @WINDOW SILL ABOVE CONTINUOUS BACKER ROD AND SEALANT, TYP. BOTH SIDES ALUMINUM
TRIM 5/8" GYPSUM BOARD 2x TREATED BLOCKING 6 THICK BATT INSULATION w/PSK-25 FACE -FULLY TAPE ALL EDGES AND SEAMS 6" METAL STUD FRAMING @8" O.C. TO CREATE CURVED WALL 3/4" EXTERIOR GRADE
PLYWOOD 3/4" EXTERIOR GRADE PLYWOOD. ANCHOR THROUGH INSULATION TO INNER PLYWOOD 2" RIGID INSULATION RECOVERY BOARD TAPERED INSULATION MEMBRANE FLASHING TO EXTEND ACROSS TOP OF WALL (2)
PIECE METAL COUNTER FLASHING, EXTEND UNDER WINDOW SILL AND TERMINATE BEYOND SILL SEALANT LINE CONTINUOUS BACKER ROD AND SEALANT, TYP. BOTH FACES OF FRAME THE FACE OF THIS WALL IS TO
BE CURVED, NOT SEGMENTED. PLYWOOD MAY BE BUILT UP TO 3/4" USING LAYERS OF THINNER SHEETS AS REQUIRED. CUT/TRIM RIGID INSULATION AS REQUIRED TO MAINTAIN 2" THICKNESS AND CURVED FACE 3
5/8" METAL STUD FRAMING @16" O.C. 3/4" PLYWOOD JAMES R. KRATZ AT ARCHI TECTREGISTERED 19500182 STATE OF I I ND A AN No. COMMISSION NUMBER DATE SHEET NUMBER SHEET TITLE The concepts,
ideas, designs, plans, and details as shown on this document are the sole property of MSKTD & Associates, Inc., and were created, developed and presented for use on this specific project.
None of the concepts, ideas, designs, plans, and details shall be used by any person, firm, or corporation for any purpose whatsoever, without the expressed written consent of MSKTD
& Associates, Inc. The Owner shall be permitted to retain copies for information and reference in connection with this project. 1715 MAGNAVOX WAY FORT WAYNE, IN 46804 voice 260.432.9337
fax 260.436.2402 930 NORTH MERIDIAN INDIANAPOLIS, IN 46204 voice 317.917.1190 fax 317.822.6236 http://www.msktd.com ARCHITECTURE ENGINEERING INTERIOR DESIGN CERTIFICATION MSKTD 5629
BUILD 65076 CONSTRUCTION SET 3-21-11 3/18/2011 11:48:56 AM 100 W 96th St Indianapolis, Indiana 46290 A6.32-11-11 Indianapolis North DetailsLake City Bank 3/4" = 1'-0" 1 Detail 1 1/2"
= 1'-0" 3 Detail 3/4" = 1'-0" 2 Detail 1 1/2" = 1'-0" 4 Detail 1 1/2" = 1'-0" 5 Detail Revisions: Date: By: