Loading...
HomeMy WebLinkAboutC402 - Electrical Site Plan.pdf VAN MULT I-USE PATH PR OPOSED BUILDING PRIVATE DRIVE PIV SC S03 S01 S01 S01 S01 S01 S01 S02 S01 S03 S03 S03 S03 S03 S03 S03 S03 S03 S03 S03 3/4" C., 2 -#6 AWG + GRD. L-15,17 3/4" C., 2 -#6 AWG + GRD.3/4" C., 2 -#8 AWG + GRD. 3/4" C., 2 -#8 AWG + GRD. 3/4" C., 2 -#10 AWG + GRD. 3/4" C., 2 -#10 AWG + GRD. L-16,18 L-16,18 3/4" C., 2 -#10 AWG + GRD. N/L N/L N/L L-13 3/4" C., 2 -#8 AWG + GRD. 3/4" C., 2 -#10 AWG + GRD 3/4" C., 2 -#12 AWG + GRD 3/4" C., 2 -#12 AWG + GRD. 3/4" C., 2 -#12 AWG + GRD. STUB OUT 2 -4" CONDUITS (1 -SPARE), FROM SERVER ROOM TO 10' OUT FROM BUILDING. S04 S04 S04 S04 S04 EM-18 VIA INVERTER 3/4" C., 2 -#12 AWG + GRD. POLE BASE ANCHOR BOLTS #6 REINFORCING ROD 1" BELOW TOP Section 'A-A' NO SCALE POLE#10 GROUNDING WIRE TO POLE GROUT BETWEEN TOP OF POLE BASE AND POLE BOTTOM PLATE AFTER POLE IS SET AND PLUMBED 5/8" CANT., ALL AROUND 0'-6" 7'-6" 7'-0" 2'-0" Pole Base Detail 'A' NO SCALE FINISHED GRADE #10AWG SOLID BARE TINNED COPPER GND. CONNECT TO (1) 5/8" X 8' GROUND ROD WITH CADWELD CONNECTION CONNECTION HAND RUBBED FINISH ABOVE GRADE ANCHOR BOLTS 18" DIAMETER BASE #6 REINFORCING ROD 1" RIGID GALVANIZED CONDUIT GENERAL SITE PLAN NOTES: 1. All dimensions are to the face of the curb, edge of the pavement, radius point, or pavement markings, as shown. 2. Saw cut all existing pavement to be removed for new construction, including but not limited to islands, curbs, walks, drives, and utilities. 3. Where new curbs, walks, and paving meet existing, they shall be aligned both vertically and horizontally. 4. Contractor to verify all existing conditions before beginning construction and report any variation to the design engineer before proceeding with construction. 5. Contact design engineer if additional dimensions or coordinates are needed for site layout. ELECTRICAL SITE PLAN NOTES: 1. Electrical contractor shall pay required fees and other costs not borne by the local power company to provide complete new electrical service. 2. Electrical contractor shall pay all fees and other costs not borne by the local telephone company to provide complete new telephone service. 3. Electrical contractor shall be responsible for relocating or removing any or all existing services, poles, etc. (electric, telephone, cable tv) as may be required to accommodate any new construction, unless otherwise noted, and shall include all fees for such work in their bid. 4. Electrical contractor shall backfill the excavation for all conduit runs under sidewalks and paved areas with bank run gravel or sand. 5. All work shown on this sheet is new and by the electrical contractor, unless otherwise noted. 6. Pole bases are to be located 3'-0" behind curbs, as measured to the center of the pole base, from parking areas unless otherwise noted. 7. Locate all underground utilities prior to digging. Hand dig as required. COMMISSION NUMBER DATE SHEET NUMBER SHEET TITLE The concepts, ideas, designs, plans, and details as shown on this document are the sole property of MSKTD & Associates, Inc., and were created, developed and presented for use on this specific project. None of the concepts, ideas, designs, plans, and details shall be used by any person, firm, or corporation for any purpose whatsoever, without the expressed written consent of MSKTD & Associates, Inc. The Owner shall be permitted to retain copies for information and reference in connection with this project. 1715 MAGNAVOX WAY FORT WAYNE, IN 46804 voice 260.432.9337 fax 260.436.2402 930 NORTH MERIDIAN INDIANAPOLIS, IN 46204 voice 317.917.1190 fax 317.822.6236 http://www.msktd.com ARCHITECTURE ENGINEERING INTERIOR DESIGN CERTIFICATION MSKTD 5629 BUILD 65076 CONSTRUCTION SET 3-21-11 3/18/2011 3:16:51 PM 100 W 96th St Indianapolis, Indiana 46290 C402 2-11-11 Indianapolis North Electrical Site Plan Lake City Bank 1" = 20'-0" Electrical Site Plan PROVIDE PAD FOR UTILITY PROVIDED 225 KVA TRANSFORMER. REFER TO DETAIL ON SHEET C602 SITE LUMINAIRE SCHEDULE Type Fixture Detail Lamp Detail Ballast Detail Mount Description Basis of Design Alternate 1 Alternate 2 Alternate 3 Count Min. Eff. % Description Qty Wattage Qty Start Type BF Max THD % Min. Start Temp. °F Input Wattage S01 Pole 19" square extruded aluminum area, arm mounted luminaire; clear tempered flat glass lens. Direct pole mount. Type IV distribution; segmented optics; horizontal lamp. Square Steel pole, 30' H, 4", 11ga. 0 PSMH; Clear; Horizontal; 15,000HR; 36,800 Lumens Initial; 4300°K; 62CRI. 1 400 1 Super CWA 1 0 -20 460 VA Gardco Form 10 Invue Vision VXM Series Lithonia Aeris AS2 Series McGraw-Edison GSM Series 7 S02 Pole 19" square extruded aluminum area, arm mounted luminaire; clear tempered flat glass lens. Direct pole mount. Type III distribution; segmented optics; horizontal lamp. Square Steel pole, 30' H, 4", 11ga. 0 PSMH; Clear; Horizontal; 15,000HR; 36,800 Lumens Initial; 4300°K; 62CRI. 1 400 1 Super CWA 1 0 -20 460 VA Gardco Form 10 Invue Vision VXM Series Lithonia Aeris AS2 Series McGraw-Edison GSM Series 1 S03 Base Diecast aluminum, bevel top louver bollard 42" high 30 1-MHC100/U/3K 1 100 1 Super CWA 1 10 -20 129 VA Gardco BRM824 McGraw-Edison BRL Series 12 S04 Ground Ingrade, direct burial LED fixture with narrow beam optics 80 Included 1 8 0 N/A 1 10 -20 8 VA Lumascape LS793LED Ilumipod TRI-3 Optic 25 Bronzelite GM5012 LED 5 REFER TO LIGHTING CONTROL SCHEDULE ON SHEET E5.2 REFER TO LIGHTING CONTROL SCHEDULE ON SHEET E5.2 REFER TO LIGHTING CONTROL SCHEDULE ON SHEET E5.2 Revisions: Date: By: