Loading...
HomeMy WebLinkAboutE2-1 - First Floor Power Plan.pdf +44 J T/P M JJ W J +44 W+44 +44 +44 +44 J J J J J J J J J J J J J J J J J J J J J J J JJ J J J J J J J J J J J J T/P J J J J T/P JJ JJJ J J J T/P J J SS J J J J J J A D F H 23 I J K L 578 10 11 B E G 461 Y 9 CONFERENCE 112 OFFICE 115 OFFICE 116 OFFICE 117 OFFICE 118 OFFICE 119 WAITING 110 HALLWAY 114 OPEN OFFICE 120 PUBLIC MEETING ROOM 106 HALLWAY 102 LOBBY 101 VESTIBULE 100 WOMEN 132 MEN 131 MEN 105 HALLWAY 103 WOMEN 104 CONFERENCE RM 140 TABLE/CHAIR STORAGE 109 SERVER 129 ELECT 108 WORKROOM 128 OFFICE 122 OFFICE 123 OFFICE 124 OFFICE 125 VISITING OFFICE 126 VISITING OFFICE 127 BREAKROOM 133 HALLWAY 121 HALLWAY 130 TELLER WORKROOM 136 SAFE DEPOSIT 138 TELLER AREA 137 BANKING LOBBY 139 OFFICE 141 OFFICE 142 OFFICE 143 OFFICE 144 +44" MDP L M.T.S. EMP1 P2 P1-5 P1-2 P1-4 P1-6 P1-7 P1-9 P1-8 P1-10 +48" +44" +44"GFCI P1-15 P1-16 P1-17 P1-18 P1-23 +2" 1 2 P1-24 +44" P1-20 GFCI +44" GFCI P1-14 P1-1 3 +44" GFCI P2-9 P2-12 33 P2-11 1 1 1 1 1 1 1 1 1 1 P1-11 P1-12 1 1 1 1 1 1 1 1 1 1 P1-13 1 1 P1-22 1 1 1 11 1 1 1 P2-13P2-14 EM-1 IG 4 3/4" C. 5 EM-2+44" +44" Printer EM-3 2 2 2 2 P2-19 WP GFCI +44" +44" EM-5 EM-7 WC WC +44" +44" +44" +44" +44" P2-16 P2-17 +44" +44" +44" EM-8 1 1 1 1 1 1 1 1 EM-9 6 6 7 7 EM-11 EM-101" C. 1" C. 8 8 9 9 P2-20 +44" +44" +44" GFCI 1 3 2 2 3131 1 3 1 3 10 11 12 13 14 15 1414 16 +48" 16 +54" +54" 12 12 12 1214 12 15 14 17 +84" +84" +84" 18 18 18 18 +84" P2-18 19 Fire Panel EM-12 P1-3 FB-1 112A 112B FB-1 106B FB-1 106A FB-1 P2-8 120G P2-1 120A P2-2 120F P2-3 120B P2-4 120E P2-5 120C P2-6 120D P2-7 FB-2 FB-2 FB-2 FB-2 FB-2 FB-2 FB-2 2 1 2 1 2 1 2 1 2 1 2 1 2 1 P2-10 P2-35,37 P2-32,34 P2-39,41 P2-40,42 P1-25,27 b a a a aaa a b a a a a b c c c d d 20 20 20 20 20 20 c FCU-1 EM-15 EM-6 P1-40,42 P1-35,37 HUM-4 HUM-8 P2-15 REFER TO HUMIDIFIER ELEVATION BELOW P2-21 21 21 21 21 RECIRC. PUMP 2 2 22 23 24 24 EM-16 24 23 25 Lighting Control 3/4"C., 2 -#8 MDP-25,27 UH-1 WH-1MDP-26,28 3/4" C., 2 -#10 17 26 26 27 28 28 29 29 29 29 30 30 32 +54" 17 P1-19 17 33 GFCI WP P2-23 P1-28 FIRE ALARM BELL CONFIRM EXACT LOCATION WITH OWNER MOUNT IN CHASE BETWEEN BASEBOARD HEATERS MOUNT IN CHASE BETWEEN BASEBOARD HEATERS +30" 11 +30" 34 34 34 34 34 34 11 1 11 1 1 +96" +96" +96" 35 35 36 11 +96" +96" GFCI WP P1-29 1 1 P2-24 P1-30 +54" 11 +44" +44" +44" P1-31 CT CABINET EM-4 2 106D FB-1 37 38 First Floor Slab 100' -0" F G S2.1 Foundation Plan Level 4 112' -8" First Floor Slab 100' -0" HUM-5 HUM-1 HUM-6 HUM-2 HUM-3 HUM-7 L-25,27 L-26,28 L-29,31 L-30,32 L-33,35 L-34,36 COMMISSION NUMBER DATE SHEET NUMBER SHEET TITLE The concepts, ideas, designs, plans, and details as shown on this document are the sole property of MSKTD & Associates, Inc., and were created, developed and presented for use on this specific project. None of the concepts, ideas, designs, plans, and details shall be used by any person, firm, or corporation for any purpose whatsoever, without the expressed written consent of MSKTD & Associates, Inc. The Owner shall be permitted to retain copies for information and reference in connection with this project. 1715 MAGNAVOX WAY FORT WAYNE, IN 46804 voice 260.432.9337 fax 260.436.2402 930 NORTH MERIDIAN INDIANAPOLIS, IN 46204 voice 317.917.1190 fax 317.822.6236 http://www.msktd.com ARCHITECTURE ENGINEERING INTERIOR DESIGN CERTIFICATION MSKTD 5629 BUILD 65076 CONSTRUCTION SET 3-21-11 3/18/2011 3:22:19 PM 100 W 96th St Indianapolis, Indiana 46290 E2.12-11-11 Indianapolis North First Floor Power Plan Lake City Bank 1/8" = 1'-0" First Floor Power Plan POWER PLAN NOTES 1 Provide power to disposal. Coordinate with supplier. 2 Provide power for dishwasher. Coordinate exact electrical requirements and connection location with supplier. 3 See architectural plans for locations of floor mounted power/data receptacles. 4 Coordinate exact location of dedicated receptacle for ATM with bank equipment supplier. Provide 3/4" conduit from ATM up to above the ceiling for data cabling. Coordinate with bank equipment supplier. 5 Provide power for night deposit light. Provide 3/4" conduit from Night deposit vault up to above the ceiling for data cabling. Coordinate with bank equipment supplier. 6 Provide 5400 series wiremold or approved equal. Provide the appropriate device brackets for power, data, phone and junction box for holdup button where indicated. Coordinate exact elevation and location with owner, bank equipment and casework supplier 7 Provide device bracket with blank cover for "Holdup" button wiring. Provide 3/4" conduit from wiremold to above the ceiling for holdup wiring by others. 8 Provide JB at driveup teller island and JB centered under driveup teller window with 1" conduit between them. Provide 1" conduit from JB under teller window up to above the ceiling for cabling. Coordinate exact location on island with equipment supplier. (Typical of 2). 9 Provide 20 circuit for common wiring between island and teller station as shown. Coordinate exact locations with equipment supplier. (Typical of 2). 10 Provide conduit stub up to above ceiling for door contact alarm wiring. Coordinate exact requirements with door supplier and owner. (JB may not be required) 11 Provide conduit from Knox Box on exterior up into ceiling space for cabling by others. 12 Provide JB and conduit stubup for "Holdup" button. Coordinate exact location with furniture. Installation of actual button and wiring by others. 13 Provide JB at roof hatch for alarm contact. Alarm wiring by others. 14 Provide JB with conduit stub up at 48" to top for Key Pad and 40" for Proximity Reader. Coordinate with Security Contractor. 15 Provide conduit stub up for door alarm contact and magnetic lock. Coordinate exact requirements with door supplier. (JB may not be required) 16 Provide JB with conduit stub up for alarm keypad. Coordinate exact requirements with alarm supplier. 17 Provide conduit stub up for door alarm contact. Coordinate exact requirements with door supplier. (JB may not be required) 18 Provide single gang box with 3/4" conduit stub up to above ceiling for security sensor (by others). 19 Provide 120 volt feed to security panel provided and installed by others. Coordinate exact location with supplier. 20 Provide Qmark (or approved equal) decorative pedestal convection heaters, type DPH05A, 208 volt, with 2p thermostat (1 per circuit) as follows: a -36" 750W, b -28" 500W, c -8' 1000W and d -6' 750W. 21 Provide JB for power to touch free plumbing fixtures. Coordinate exact location and connections with M.C. 22 Provide 4000 series wiremold from floor up to 60" with blank cover. Provide device brackets at 40" for Proximity Reader (by others) and at 48" to top for Key Pad (by others). Provide 1" conduit from wiremold underground into building beyond Lobby 101 and then up to above ceiling for cabling by others. Coordinate with Security Contractor. 23 Provide 4000 series wiremold from floor up to 60" with blank cover. Provide device bracket for power assisted door actuator. Provide interconnection wiring between power assisted door and controls. Coordinate exact requirements with architect and door supplier. 24 Provide 3/4" conduit from door mullion to assisted door operator. Provide Provide interconnection wiring between power assisted door and controls. Coordinate exact requirements with architect and door supplier. 25 Provide interconnection wiring between pedestal mounted power assisted door actuator and proximity reader (equipment and pedestal by others). Provide 1" conduit from pedestal underground into building beyond Lobby 101 and then up to above ceiling for cabling by others. Provide conduit and interconnection wiring to door. Coordinate with Security Contractor and door supplier. 26 Provide JB and 3/4" conduit stub up for security siren. (Siren and wiring by others) 27 Provide JB and 3/4" conduit stub up for security wiring to cash vault or security deposit vault. Coordinate exact placement with vault suppier and security vendor. 28 Camera provided and installed by others. May be ceiling mounted dome or wall mount. Wall mount will require JB and 3/4" conduit stubbed above ceiling. Shown here for reference only. (Typical of several) 29 Exterior mounted camera provided and installed by others. Provide JB and 3/4" conduit stubbed into building above layin ceiling. Coordinate exact placement and JB box mounting with owner and architect. (Typical) 30 Mullion mounted security camera. Coordinate conduit routing into building from underground up into above ceiling of bank lobby. 31 Mount duct smoke detectors in return duct inside building, between last inlet and rooftop unit. Mount detector above ceiling in accessible area (hallway) where possible. (Typical for all 8 units) 32 Dome camera mounted in canopy, provided and installed by others. Provide JB and 3/4" conduit stubbed into building above layin ceiling. Coordinate exact placement and JB box mounting with owner and architect. (Typical) 33 Provide 3/4" Plywood on south and west walls from 24" A.F.F. to 72" A.F.F. Paint to match wall finish. Provide 9" wide ladder style cable tray as shown on cable tray detail on Sheet E5.1 34 Provide receptacles beneath sinks for powered soap dispensers. Coordinate exact placement with architect. 35 Provide provisions for a wireless access point, 6" above the ceiling in this area. 36 Provide power for ceiling mounted projector. Provide 2 -3/4" conduits from communications floor box up to projector for A/V cabling. 37 Provide power for ceiling mounted projector screen. Provide a 2 gang box with 2 -3/4" conduits up to screen location for A/V controls. Coordinate exact location with A/V supplier. 38 Provide duplex receptacle, 2 -data jacks and one single gang box with 3/4" conduit up to above the ceiling; all mounted at standard height in the back of the base cabinet. Coordinate with A/V suppler. Humidifier Elevation Revisions: Date: By: