Loading...
HomeMy WebLinkAboutE3-1 - First Floor Lighting Plan.pdf SO SO SO SO SO SO SO SO SO SO SO SO SO SO SO SOSO SO SO SO SO N/L N/L N/L N/L N/L D D D D D OS SO SO SO SO SO SO SO SO SO OSSO SO OS OSOS OS OSOS OS D OS SO A D F H 23 I J K L 578 10 11 X B E G 461 Y 9 CONFERENCE 112 WAITING 110 PUBLIC MEETING ROOM 106 OFFICE 115 OFFICE 116 OFFICE 117 OPEN OFFICE 120 HALLWAY 102 LOBBY 101 MEN 105 HALLWAY 103 WOMEN 104 TABLE/CHAIR STORAGE 109 SERVER 129 ELECT 108 WORKROOM 128 MEN 131 WOMEN 132 CONFERENCE RM 140 HALLWAY 121 OFFICE 122 128 SF OFFICE 123 129 SF OFFICE 124 129 SF OFFICE 125 129 SF VISITING OFFICE 126 129 SF VISITING OFFICE 127 BREAKROOM 133 HALLWAY 130 HALLWAY 114 COATROOM 111 TELLER WORKROOM 136 SAFE DEPOSIT 138 TELLER AREA 137 BANKING LOBBY 139 OFFICE 141 OFFICE 142 OFFICE 143 OFFICE 144 OFFICE 118 OFFICE 119 L-1 L-2 F06 F06 F06 F06 F06 F06 F06 F06 K01 K01 K01 K01 K01 K01 F08 F08 K03 K03 K03 K03 K03 K03 K03 K03 F08 K03 K03 F08 K03 K03 K03 F08E F08 F08 F07 F08 F08 F07E F08 F08 EX F08 F08E F08 F08 F08 F05 F05 F05 F05 F05 F05 F05 F05 F05 F05 F05 F05 F05 F05 F05 F05 F08 F08 F08 F05 F05 F05 F05 F05 F05 F05 F05 F05 F05E F05 F05 F05 F05 F05 F05 F05 F05 F05 F05 F05 F05 F05 F05 F05 F05 F05 F05 F05 F05 F05 F05 F05 F05 F05 F05 F05E F05 F05 F05 F05 F05 F05 F05 F05 F05 F05 F05 F05 F05 F05 F05 F05 F05 F05 F05 F05 F05 F05 F05 F05 F05 F05 F05 F05 F05 F05 F05 F05 F05 F05 F05 F05 F05 F05 F05 F05 F06 F06 F06 F06 K01 K01 K01 F06 K01 F06 F02 F02 F02 F02 F05 F05 F05 EX EX EX F05 F05 F05 F05 F05 F05 F05 JB JBJB 1 2 F06 F06 F06 F06K03 K03 K03 K03 F05E K03 K03 K03 K03 F05 F05 F05 F05 K03 K02 K02 K02 K02 K02 K02 K02 K02 K01 K01 K02 K02 c b a d a a a a a aa a b bb b cc c c cccc d db b c c K02 K02 aa bb aa a bb ac c c b a K03 K03 F05 F05 F05 F05 F05 F05 K03 K03 K04 K04 K04 K04 K04 K04 K04 K03 K03 K01 K01 K01 K01 K01 K01 K01 K01 K01 K01 K01 K01 K03E K03 K03 K03 K03 K03E F05 3 b a aa bbb b b b a b b b b b bb MDP EML P1 P2 Fire Panel M.T.S. L-3 K03 L-4 F05 F09 F09 F09 F09 F05E F05E 4 4 4 4 N/L N/L N/L EM-17 L-8 L-8 L-9 5 5 5 5 5 5 5 5 b a abb aa bb a 6 6 6 L-6 L-7 5 5 Lighting Control K05 TIE TO EM-13 CIRCUIT 7 EM-18 EM-18 EM-18 VIA RELAY 5 VIA RELAY 6 L-10 L-5 K06 8 K03 K03 5 JB JB JB L-11 L-13 L-14 9 9 9 F10 F10 F11 10 L-5 1111 11 11 11 11 11 11 COMMISSION NUMBER DATE SHEET NUMBER SHEET TITLE The concepts, ideas, designs, plans, and details as shown on this document are the sole property of MSKTD & Associates, Inc., and were created, developed and presented for use on this specific project. None of the concepts, ideas, designs, plans, and details shall be used by any person, firm, or corporation for any purpose whatsoever, without the expressed written consent of MSKTD & Associates, Inc. The Owner shall be permitted to retain copies for information and reference in connection with this project. 1715 MAGNAVOX WAY FORT WAYNE, IN 46804 voice 260.432.9337 fax 260.436.2402 930 NORTH MERIDIAN INDIANAPOLIS, IN 46204 voice 317.917.1190 fax 317.822.6236 http://www.msktd.com ARCHITECTURE ENGINEERING INTERIOR DESIGN CERTIFICATION MSKTD 5629 BUILD 65076 CONSTRUCTION SET 3-21-11 3/18/2011 3:17:00 PM 100 W 96th St Indianapolis, Indiana 46290 E3.12-11-11 Indianapolis North First Floor Lighting Plan Lake City Bank 1/8" = 1'-0" First Floor Lighting Plan LIGHTING PLAN NOTES 1 Provide JB with power and switch leg for Driveup signage provided by others. Power from circuit Em-18. Coordinate exact placement with signage supplier. 2 Provide switch box(es) for control of Driveup signage. Coordinate exact requirement with signage supplier. 3 Provide ceiling mounted occupancy sensor. Tie to lighting control panel such that lighting is controlled by occupancy sensor during off hours. 4 Circuit emergency fixtures in restrooms to be controlled by occupancy sensor but in the event of loss of power, fixture is energized by the battery pack. 5 Connect exit signs and nightlights to circuit EM-13. 6 Wire conference rooms and public meeting rooms such that ceiling occupancy sensor is in series with wall mounted lighting controls and undercabinet light. Power to lighting to be automatically interrupted when rooms are unoccupied. 7 Provide inverter Bodine # ELI-100-SD or approved equal to power Facade/Egress lighting at front entrance. 8 Provide self-contained lighting panel with integral time clock, control relays, and modem capable of accepting inputs from photocells and switches and with full programing capability. LC & D GR14016 or approved equal. Provide master override switches for all relays and exterior mounted photocell on north side of building. 9 Provide power feed to sign lighting. Coordinate exact location and requirements with sign supplier and architect. 10 Interlock undercabinet light such that power is switched off to fixture via occupancy sensor in ceiling. 11 All ballasts in F05 fixtures in all Private Offices and Rooms 128,133, and 136 are to be two ballast style. The wall mounted occupancy sensors are to be two level switch style in these areas as well. (Typical) Revisions: Date: By: